Download MSA PLUS 400
Transcript
Operating instructions MSA Plus 400 4.8 4 Configuration Traceability Z44 This feature allows the user of the fusion set to enter additional information regarding the components being used ( ISO 12176-4 norm). The data may be entered either by means of a barcode or by the MSA Plus 400 keypad, whereas an authorized person defines, using a configuration barcode, which additional information must be entered. The configuration barcode is generated by the program MSA WIN-WELD. The additional information will be stored, together with all other relevant data, following the fusion process (see chapter 3.5) . Display when Fitting active: TRACEABILITY DATA: FITTING? S MNU T MNU W LFT MSA Plus 400 GB 14:20 03-06-2007 X EDT ENT Display when element 1 or element 2 active: TRACEABILITY DATA: ELEMENT 1? S MNU T MNU W LFT MSA Plus 400 GB 14:20 03-06-2007 32mm X EDT ENT LENGTH: ELEMENT 1? 000.00 m S MNU T MNU MSA Plus 400 W LFT X EDT ENT GB 14:20 03-06-2007 32mm 32mm/100mm Skipping an input: Using the ENTER-key , barcode or keyboard data input can be skipped. Subsequently, the next display indication will be shown (The skipping feature may be disabled via the configuration menu). Manual entry: Using the RIGHT-key, the edit mode is selected; you may now manually enter data (The manual entry feature may be disabled via the configuration menu). Manual input of barcode data : FITTING? 3736030321999140 5705030314 S UP T DWN W LFT MSA Plus 400 GB 14:20 03-06-2007 X RGT ENT (10.07) MSA Plus 400_e.doc 21