Relay Remote Controls Electrical wiring must be in accordance with local regulations and codes. To connect remote control equipment to the heat pump, perform the following steps: Disconnect all power to the heat pump and control system. 1 Access the wiring compartment. 2 Run the wires from the pool/spa remote control system into the upper electrical compartment. 3 Connect the wiring from the pool/spa remote control system to the heat pump remote control terminals Note: Do not apply voltage to the Spa/Pool /Com terminals. A dry contact is required ! 4 Replace the electrical service panel. 5 Replace the top panel. 6 Restore power to the heat pump and the pool/spa remote control system. 7 Press the Menu Select button repeatedly to scroll to the Remote Control screen. Toggle the selection by pressing one of the arrows until the screen displays “Relay”. 8 Set the temperature of the pool/spa on your external thermostat controller. The temp settings on the Ultratemp-E are not accessible when the “relay” remote Control function is selected on the heat pump Connecting the Heat Pump to IntelliPool automation systems via the RS-485 Connector ® The heat pump can be controlled by an IntelliPool system via the RS-485 communication cable. In this configuration, IntelliPool overrides preset Temperature Set points on the heat pump and will start or stop the heat pump. ® The transfer of this data takes several seconds and causes a delay from when the command is given from the IntelliPool® control center until the heat pump physically responds. This happens automatically but may take 1-2 minutes to complete. Note: Heat pump control board set points will be disabled and shown as N/A. Temperature Setup is done within the IntelliPool system (setpoint menu). The heater can be activated in the Command Menu on internet or the settings/temp menu on the control center. Disconnect all power to the heat pump and control system. 1. Access the wiring compartment. 2 ® 2. Run a 2x0.5mm cable from the IntelliPool data bus into the heat pump wiring compartment. It is possible to use excess IntelliFlo communication cable. 3. Connect the IntelliPool bus data + and – to the DT+ and DT- terminal inside the UltraTemp-E wiring compartment. The inputs are part of an RS485 interface. Note: Do not apply voltage to the RS485 terminals 4. Replace the electrical service panel. 5. Replace the top panel. 6. Restore power to the heat pump and the pool/spa remote control system. 7. Press the Menu Select button repeatedly to scroll to the Remote Control screen. Toggle the selection by pressing one of the arrows until the screen displays “RS485”. Set the temperature of the poo/spa on your IntelliPool system. The temp settings on the Ultratemp-E are not accessible when the “relay” remote Control function is selected. Switch on the heat pump. 10 UltraTemp®-E ENGLISH Note: Heat pump control board set points will be disabled and shown as N/A. Temperature Setup is done using an external thermostat controlled system.