Kapitel 16 – Firmware - Überarbeitungsverlauf Added Preset Configuration Parameter "W&M Controlled" that adds W&M write protection via screen and remote register access (inc. Modbus) to certain parameters. Changed level of "Blnd Chk Alarm %", "Blnd Chk Alarm Vol", "Blnd Chk Alarm Time" to CONDITIONAL. Added Additive Configuration Parameter "W&M Controlled" that adds W&M write protection via screen and remote access to certain parameters. Changed level of "Additive Vol/Inject", "Vol/Inject Cal Factor", "Additive Mtr KFactr", "Additive Mtr Factor", "Max Pstn Missed Inj", "Under Add Alrm # Inj", "Over Add Alrm # Inj", "Check Add Tol Time", "Over Inj Vol" level to CONDITIONAL. Removed Additive Configuration Parameters "W&M Vol per Inject", "W&M Vol factor", "W&M Pulses per vol", "W&M Pulse Factor" since no longer needed. Added Component Configuration Parameter "W&M Recipe Percentage" to enforce delivery. Corrected Meter Proving Screen Meter Factor data entry data column alignment. Updated Equipment Configuration Database version to 3.29.01. Added printer multidrop capability to Ticket Printing. Added printer multidrop capability to Alibi Log Printing. Added ability to multi-drop several MultiLoads on to a single printer using RS232 on COM2. Connections must be as follows: ML#1 ML#n Serial Printer RX<-------------RX<--------------------TX CTS<------------CTS<-------------------DTR TX------------->TX-------------------->RX GND-------------GND--------------------GND DSR-DTR DSR-DTR RTS-CTS-DSR RTS-DCD<------->RTS-DCD DCD Added more discrete control of the Transmitter Enable to support having multiple MultiLoads connected to a single printer. Dropped monitoring of DSR or DCD for printer status. CTS indicates printer status. Added Meter Configuration Parameters "Adaptive Valve Control", "Analog Valve Control", "4-20mA Increase Step", "4-20mA Decrease Step" to support analog valve control. Allow ports 2 & 3 to be used as general IO when Analog Valve control is enabled. Increased latest known FCM version to 037. On FCM_TESTER and ISO_TESTER build, allow entry into factory menu. Updated FCM2 values during EPROM and not Updated FCM2 Updated FCM2 Analog Calibration to ignore COM timeouts when setting calibration test. Was causing test to sometimes restart when FCM was writing to communicating. Analog RTD/mA Calibration to perform 3 tests then stop. Analog RTD/mA Check to perform 1 test then stop. Added Legacy ACR test to Factory Menu. Expanded Configuration Prompts Register, r100-104, to return a max of 90 bytes and a default of 30 bytes (instead of 20 bytes) to support UTF-8 worst case. Increased size of Alarm Names storage to handle UTF-8 characters. Expanded Alarm Configuration Registers, R/U710-714, to return 30, instead of 10 bytes to support UTF-8 worst case. Expanded Modbus Alarm Configuration Registers, 2500-2599, to return 15, instead of 10 bytes to support UTF-8. Updated Alarm Setup Screen to properly display UTF-8 strings. Updated RCU Setup Database version to 3.29.01. Firmware Version 3/4.31.13 433
Related documents
20130631 - Toptech Systems
Smith Meter AccuLoad III with ALX Firmware
FMU 860 - PP engineering
SG4206 - Feinhals
Betriebsanleitung RHEONIK Massedurchflussmesser RHE 14 RHM
NOTE - Toptech Systems
20121031 MLII_SMP_Installation Guide
VoIP Bridge Server Version 2
User`s Manual - Oracle Documentation
Section 3 - Installation & Maintenance