Download Operating Instructions
Transcript
TYROLIT Hydrostress AG 4.8 Switching off the wall saw Switching off the wall saw Proceed as follows: XX Press the start switch (1) on the remote controller to the 0 position. XX Turn off the cooling water, switch (2) water 0/1. XX Switch off the wall saw WSE811 using the main switch (3). XX Switch off the WSE811 wall saw using the main switch on the wall saw head. Caution Frost can damage the wall saw WSE811! XX Blow out any water if there is a risk of frost (see chapter 4.9, Blowing out the water). Only stop the wall saw WSE811 using the EMERGENCY STOP function in an emergency. 4.9 Blowing out the water 99 The main switch is set to OFF XX Disconnect the mains plug. XX Disconnect all water lines. XX Connect the purge pump to the water nipple. XX Blow out water until all of the cooling water has been removed (see chapter 5.2). XX Remove the pump. Page 26 Wall saw WSE811