Download Operating Instructions - SEW

Transcript
Electrical Installation
Electrical connections
5.9.3
5
X8: AC 400 V output and CAN bus (DSC hybrid)
The following table shows information about this connection:
Function
AC 400 V output, CAN bus (SBus)
Connection type
M23 H-Tec, SEW P insert 15-pole, female, coding ring red-violet
Wiring diagram
4
8
7
SHLD
2
1
5
6
9
10
3
A
D
PE
B
C
2749367179
Assignment
No.
Name
Function
A
L1
Actuator supply phase L1
B
L2
Actuator supply phase L2
C
L3
Actuator supply phase L3
D
n.c.
Not connected
PE
PE
PE connection
1
n.c.
Not connected
2
n.c.
Not connected
3
n.c.
Not connected
4
n.c.
Not connected
5
n.c.
Not connected
6
n.c.
Not connected
7
CAN_L
CAN data line (low)
8
CAN_GND
Reference potential CAN bus
9
CAN_H
CAN data line (high)
10
n.c.
Not connected
SHLD
CAN_SHLD
Shield/equipotential bonding CAN bus
Operating Instructions – MOVIFIT® FDC
69