Download Internal II User's Manual.cdr

Transcript
IMPORTANT
Installation requires an experienced mechanic with specific knowledge in the installation of
the VIESA Ecological Cooler. Installation, disassembly, repairs and maintenance
must be performed by an Authorized Installer. Authorized Installer must use proper
protective equipment when installing the system.
Improper installation or use of unauthorized parts can cause malfunctions, loss of battery life
or other consequences which may result in serious injury.
Manufacturer or Distributor will not be responsible for injuries or damages resulting from
misuse of equipment, use contrary to operating instructions or installation by any person
other than an Authorized Installer.
Information contained in this manual is subject to change. Manufacturer reserves the right,
without notice, to make changes in equipment design or components as progress in
engineering, manufacturing or technology may warrant.
World-wide Patents
VIGIA is a trademark of Col-Ven S.A.
INTRODUCTION
VIESA delivers cool air to the truck's cabin without running the truck's
engine.
Cooling is generated by vaporized cool water delivered by a self-contained
electrical motor. During operation it only consumes water and it makes no
use of internal combustion engines, nor does it use chemical coolants or
emit gases into the atmosphere.
VIESA is totally ecological and provides the driver with a healthier rest
and a more comfortable driving condition, increasing driver satisfaction.
PAGE 1 OF 11
CONTROL PANEL AND REMOTE CONTROL
Important: Before turning on the system make sure that one of the cab's
windows is open 2 or 3 cm and that all other openings or vents are
closed preventing outside hot air from entering the cab.
SYSTEM ON - OFF
WATER PUMP ON -OFF
REMOTE CONTROL
RECEIVER
Power
SYSTEM
DISCONNECTION
AUTO
(PRESS
FOR TWO SECONDS)
MENU FUNCTION SET-UP:
TURBO FAN SPEED
üTIME
üALARM CLOCK
üSELF POWER ON
üSELF POWER OFF
üAUTOMATIC MODE
CONTROLS
Menu
Dry
EVAPORATOR DRYING
FUNCTION
IN MENU SET-UP MODE
PRESS TO SCROLL
FUNCTIONS
By default time is in 24H format
and temperature is shown in °C.
PAGE 2 OF 11
TURBO FAN AT
HIGHEST SPEED UNTIL
EVAPORATOR IS DRY
The remote control performs all the functions
detailed above.
WARNING:
- Keep batteries away from children. Wrong use may cause fire, explosion or burns.
Batteries are not rechargeable. Do not expose batteries to heat in excess of 100ºC.
Use only AAA batteries.
- Dispose batteries in accordance with local regulations.
DISPLAY INFORMATION
AUTOMATIC DRYING
ACTIVATED
AUTOMATIC MODE
ACTIVATED
TURBO FAN
ON
TIME
TURBO FAN SPEED
LEVEL
WATER PUMP OR
TURBO FAN
DISCONNECTION
WATER PUMP CYCLE
ACTIVATED
SELF POWER ON OR
OFF ACTIVATED
BATTERY LEVEL
WATER TANK
EMPTY
ALARM CLOCK
ACTIVATED
PAGE 3 OF 11
SHORT CIRCUIT IN THE WATER
PUMP OR TURBO FAN EVAPORATOR CHANGE
INDICATOR
IMPORTANT: CALL YOUR LOCAL
TECHNICAL SERVICE
OPERATION
PERMANENT DISPLAY INFORMATION
- Clock.
- Battery level: at low battery voltage, a
blinking indicator will appear and the turbo fan
speed will start slowing down
When
is permanently displayed, change the
evaporator. Call your local technical service.
TURBO FAN
By pressing
the turbo fan
and the water pump
will be activated.
By pressing
again, the turbo fan
and the water pump
will be disconnected.
There are 8 turbo fan speeds , which can be
selected by pressing
or
.
Note: keeping the up or down button pressed will vary turbo fan speeds in sub-levels
(a total of 24). These sub-levels will not be displayed and will not emit any sound.
PAGE 4 OF 11
If the turbo fan is disconnected
is displayed
and the system will make a sound. This indicator
will disappear after the problem is solved and
the system turned on by pressing
.
If turbo fan battery consumption is abnormal,
will be displayed and the system will
and
make a sound.
These indicators will disappear after the problem is
solved and the system is turned on by pressing
.
If there is damage to internal electrical components
will blink and the system will turn off.
These indicators will disappear after the problem is
solved and the system is turned on by pressing
.
WATER PUMP
By pressing
Pressing
the water pump will turn off.
again will turn the water pump cycle on.
PAGE 5 OF 11
If there is not enough water in the tank, the pump will
not work,
will be displayed and the system will
make a sound.
will turn off when pouring water in the tank.
will be
If the water pump is disconnected,
displayed and the system will make a sound.
This indicator will disappear after the problem is
fixed and the pump cycle is turned on by pressing
.
If water pump battery consumption is abnormal,
will be displayed and the system will
and
make a sound.
This indicator will disappear after the problem is
.
fixed and the pump cycle is turned on by pressing
SYSTEM SET UP
Use
-
Menu
to set up the following:
Clock time
Alarm
Self power on
Self power off
Automatic mode
PAGE 6 OF 11
CLOCK TIME
Press
is displayed and then press
until
Menu
.
The hour blinks, press
Press
Use
or
to set the hour.
to select the minutes.
or
to set the minutes.
To confirm set time wait 5 seconds or press
ALARM
Press
until
Menu
is displayed and then press
The hour blinks, press
Press
Use
or
to set the hour.
to select the minutes.
or
to set the minutes.
PAGE 7 OF 11
.
Press
and
Press
to activate or press
blinks
to cancel.
Note: To confirm alarm wait 5 seconds or press
To turn off the alarm press any key from the control panel or
remote control, except for
Power
.
SELF POWER ON
It allows to turn on the system automatically at an established time.
and
Use Menu until
appear and then press
Program the clock (see "Clock Time").
Use
to select
.
.
Then
blinks, press
to cancel.
to activate it or press
Note: To confirm self power on wait 5 seconds or press
.
SELF POWER OFF
It allows to turn off the system automatically at an established time.
is displayed and then press
Use Menu until
Program the clock (see "Clock Time").
Ussing
,
is selected.
Then
blinks, press
to cancel.
to activate it or press
Note: To confirm self power off wait 5 seconds or press
Self Power Off can be set even when the equipment is turned off.
PAGE 8 OF 11
.
AUTOMATIC MODE
It adjusts automatically the speed of the turbo fan according to the
exterior temperature.
Use
Menu
until
appears and then press
Then
blinks, press
to deactivate it.
.
to activate it or press
Note: To confirm automatic mode wait 5 seconds or press
In Automatic Mode turbo fan and water pump will not be turned off even
if exterior temperature decreases excessively. Turbo fan will continue working
at minimum speed.
AUTOMATIC DRYING
This function dries automatically the evaporator.
Activate Automatic Drying when the system will not be used for more than 48 hs
to avoid bad smells when restarting the system.
Press Dry and drying will start with a countdown until
process is completed.
To cancel drying press Dry
By default, the drying process lasts 35 minutes.
Drying time can be re-configured by Authorized Installer.
PAGE 9 OF 11
SYSTEM DISCONNECTION
, the equipment will disconnect
When pressing for 2 seconds the button
completely (including the display). To re-connect press
.
Power
Power
MAXIMUM TIME OF SERVICE
, it will work for a maximum
Every time the equipment is turned on with
period of time previously established and then it will turn off automatically.
By default, this period lasts 9 hours.
Maximum Time of Service can be re-configured by Authorized Installer.
GENERAL RECOMMENDATIONS
When
is displayed, call your local technical service.
During short stops leave the equipment on so as to keep the cabin fresh.
The system will delay in cooling until the evaporator is totally wet.
Do not use fuses higher than 10 Amp.
The system will self disconnect automatically under low voltage to
prevent battery damage.
Use only clean water.
The system consumes between 1 to 5 liters of water per hour
depending on exterior temperature.
When performing system maintenance or when the evaporator has been
removed, the system MUST BE DISCONNECTED.
System must not be turned on with evaporator removed.
PAGE 10 OF 11
Keep the tank clean: At every 200 hours of use:
- Drain all the water from the tank by removing the drain plug.
- Rinse with clean water.
- Pour one bottle of VIESA scented cleansing fluid and top up tank with
clean water. If using Calfa Bas, change package every 6 months.
WITH VIESA FLUID
WITH GRANULATED CALFA BAS
Do not use chemical products to clean the control panel.
At every two months of use or according to working conditions:
- Submerge the evaporator in water with bleaching (1).
- Clean the grids of the air entrances (2).
- Clean the filter of the collector tray (3).
PAGE 11 OF 11
LIMITED WARRANTY
This limited warranty is provided to the original buyer only and covers the VIESA ECOLOGICAL CAB COOLER (the
"Product") manufactured by Col-Ven S.A. (the "Manufacturer") and distributed by RCR Systems Limited (the
"Distributor").
The warranty period is two years from date of original purchase by the buyer. During this period, if the product is
found to be defective in mechanical or electrical materials or workmanship during normal use, it will be repaired or
replaced at no charge to the buyer. The buyer will be required to show date and proof of purchase and to return the
Product pre-paid to an Authorized Dealer.
THIS LIMITED WARRANTY DOES NOT COVER, AND MANUFACTURER OR DISTRIBUTOR WILL NOT BE
RESPONSIBLE FOR, THE FOLLOWING:
-Normal wear of parts;
-Failures or defects due to negligent use, misuse, neglect, abuse, use on improper voltage or current, use contrary
to operating instructions, accidents, alterations, disassembly, installation, repair or alteration by any person other
than an Authorized Dealer, fire, floods or acts of God.
-Products or accessory equipment not manufactured by the Manufacturer.
-Performance of Product when used in combination with other products or equipment not manufactured by the
Manufacturer.
-Payments for labour or service to unauthorized representatives or service agents.
Manufacturer or Distributor will not be responsible for loss of time, inconvenience, loss of use of the Product, injury
to buyer or other persons or damage to vehicle or property caused by the Product or by its failure to work or for any
other incidental, punitive or consequential damages.
The Manufacturer reserves the right to make the final decision on any warranty claim that may be questionable.
This warranty is not transferable.
EXCEPT AS PROVIDED HEREIN, THIS WARRANTY EXPRESSLY EXCLUDES:
(i) all warranties and conditions, whether express, implied or statutory, including but not limited to warranties and
conditions of merchantability for a particular purpose; and
(ii) any agreements, representations, affirmations, warranties or conditions, whether oral or written, made by any
agent, employee or representative of seller.
This warranty sets forth the entire responsibility of Manufacturer and Distributor with respect to the Product. The
buyer's exclusive remedy is repair or replacement as stated herein. In no event shall Manufacturer or Distributor's
liability exceed the cost of correcting defects as provided herein and any such liabilities will terminate upon
expiration of the two year warranty period.
USER'S MANUAL VIESA INTERNAL II
REVISION 002
P.O.Box 1352 – 1500 Avenue Road
Toronto, Ontario M5M 0A1
CANADA
Ruta 11 Km.814 - Guadalupe Norte
Prov. de Santa Fe (S3574XAB)
ARGENTINA
ORDER ON-LINE
www.viesa.ca / 1-888 438-8444