4.2.7.
System 7
2 Collector arrays (east / west roof) - 1 Storage tank - 1 Pump - 1 Valve
Terminal layout
N R1 N R2 N n.c n.c. R3
1
L n.c. n.c. X
Wire bridge
2
3
4
5
6
GND GND GND GND GND GND
T3
L
PE PE PE PE n.c. L
T2
N
T1
The loading strategy for storage tank (T3) is set to use
temperature differential control at the factory and can be
adjusted using the Parameter menu (chapter 4.4), or set
to use target temperature control.
Display screen 2.7
R2
Loading strategy
Display
R1
The solar circuit pump (R1) is switched on as soon as the
switch-on temperature difference between one of the
two collector arrays (T1, T2) and the storage tank (T3) is
exceeded. The switching valve (R2) is always set so that
flow occurs through the warmer of the two collector
arrays (T1, T2). The pump (R1) switches off as soon as
the switch-off temperature difference between the two
collector arrays (T1, T2) and the storage tank (T3) falls
below the threshold or the maximum storage temperature is reached.
230 V ~
115 V ~
Description
Note: When no voltage is on the system, the switching
valve (R2) must be set to collector array 1 (T1).
Storage
tank
1
ay
rr
1


ra
y
ar

or
ct

ra
lle

o
ct


lle
Co

2
Co
T1


T1 T2
R2

T3
R1
T1 = Temperature sensor for collector array 1
T2 = Temperature sensor for collector array 2
T3 = Lower temperature sensor for storage tank 1
R1 = Solar circuit pump 1
R2 = 3-way switching valve 1