Download Brief operating instructions.
Transcript
KaVo PRIMUS 1058 S/TM/C/G Brief operating instructions. KaVo Primus® 1058 S/TM/C/G. These brief operating instructions cover only the essential control functions. They do not replace the standard operating instructions which form part of the delivery. It is essential to consult the standard operating instructions in order to avoid faults and damage. Patient´s chair Control Save automatic position. Set desired chair position using keys or using multifunctional foot control when instruments are replaced in the holder. Press key LP/AP briefly. LEDs flash for about 4 seconds. Press required key for about 4 seconds until a signal is heard. 2 + Keep foot switch and AP key depressed and also press desired key on the dentist's or assistant's element until a signal is heard. + Assignment of the AP keys on the multifunctional foot control. KaVo Primus® 1058 S/TM/C/G. Dental chair Control Call up automatic position. Assistant’s element and Comfort assistant’s element: Press LP/AP key briefly. LEDs flash for about four seconds. During this time, press desired key AP briefly. Standard assistant’s element : Press joystick briefly. LEDs flash for about four seconds. During this time, move joystick in the appropriate direction. or with instrument removed, call up automatic position. For safety, when the spittoon is swivelled in, the chair movement is limited. 3 KaVo Primus® 1058 S/TM/C/G. Choose dentist’s level 1/2. Control/Display When instruments are set down 2 Switching on the multifunction foot control: + Keep the foot switch depressed and additionally operate the stirrup switch. or 1 Switching 2 on the Memospeed control: E123 Keep level preselection key depressed until a signal is heard. 0 Dentist’s level 1 LP AP 1 2 M SP 0 Dentist’s level 2 LP AP 1 2 M SP 4 KaVo Primus® 1058 S/TM/C/G. Instruments Control/Display Set cooling state. Remove instrument. or Cooling state: Spray Storage (without installed Memospeed): Press LP/AP key with instrument picked up until a signal is heard. 2 Storage (with installed Memospeed): Press level preselection key with instrument picked up until a signal is heard. E123 5 KaVo Primus® 1058 S/TM/C/G. Instruments Control/Display Set cold light on/off and cold light intensity. Remove instruments. Press cold light preselection key briefly. Cold light: On Intensity: (without installed Memospeed) Keep cold light preselection key depressed. min. 1 2 1x 3 4 5 6 7 8 max. 9 10 10x Storage: Press LP/AP key with instrument picked up until a signal is heard. 6 KaVo Primus® 1058 S/TM/C/G. 0 LP 0 AP LP AP SP Setting the cold light intensity. Control/Display Level E, 1, 2, 3 (with installed Memospeed) 2 Remove instruments. Press level preselection key until a signal is heard. E123 2 E123 Press level preselection key 2 x briefly. SP 00The cold light intensity can be set lux: in 10 steps using the plus key or the minus key. LP LP AP AP 22 SP SP 0 lux: LP AP Storage: 2 Press level preselection key until a signal is heard. E123 SP 7 KaVo Primus® 1058 S/TM/C/G. Speed setting turbine. Control/Display (with installed Memospeed) Level 1, 2, 3 Remove 2 instrument. E123 Press level preselection key until a signal is heard. It is possible to switch between maximum and manual mode using 0 the minus key. 0 the plus key and turbine: maximum Maximum mode: LP The turbine isLP always operated at maximum speed at every position AP 1of the foot switch. 2 2AP Manual mode: A speed between 160,000 min-1 (left stop) min-1 (right stop) can be SP and 300,000 SP selected by means of the foot switch on the multifunction foot control. turbine: manuell Storage: 2 Press level preselection key until a signal is heard. E123 Setting the Motor reverse. Remove motor from the support. Press motor reverse key or press motor reverse key on the multifunction foot control. LED lights up: Motor reverse has been preselected. or Saving: Press LP/AP key with instrument picked up until a signal is heard. 8 0 KaVo Primus® 1058 S/TM/C/G. LP Speed setting motor/ 0 2 Intensity setting PIEZOlux/ COMFORTdrive 200 XD AP SP Control/Display E123 LP 0 (with installed Memospeed) Level 1, 2, 3 1 AP LP Remove motor/PIEZOlux 2 Motor minimum: key AP Press level preselection 2 until a signal is heard. 0 SP minimum: 2 0 SP Set the intensity using the plus key and minus key. 1 LP E123 AP LP AP motor 2 0 Minimum mode: K motor: 400 min-1 0 KL motor: 2000 min-1 SP 1 SP 2 maximum: maximum: PIEZOlux/COMFORTdrive 200 XD AP 2 minimum: 2 PIEZOlux/COMFORTdrive 200 XD 2 LP Maximum mode: LP K motor and KL motor: 40000 min-1 AP minimum ≤ maximum 0 SP minimum: Minimum: 1/Maximum: 10 0 The step size is 0.25. SP 1 LP E123 AP COMFORTdrive 200 XD LP Min 1: 30.000 min-1 -1 AP Max 10: 200.000 min 2 maximum: 2 Storage: minimum ≤ maximum SP maximum: 2 Press level preselection key SP until a signal is heard. E123 9 KaVo Primus® 1058 S/TM/C/G. ON/OFF functions of heating and cold light on the multifunction handpiece Control/Display Setting on dentist’s element mf-syringe Remove multifunction handpiece from the holder. Holder switch is operated. Press spray preselection key or press spray preselection key on the multifunction foot control. or LED lights up: heating and cold light for multifunction handpiece on dentist’s element are preselected. Storage Press LP/AP key with instrument picked up until a signal is heard. Cold light intensity is constant. 10 KaVo Primus® 1058 S/TM/C/G. ON/OFF functions of heating and cold light on the multifunction handpiece Control/Display Setting on Comfort assistant’s element mf-assist Remove multifunction handpiece from the holder. Press air or water key on the multifunction handpiece briefly. or Press spray preselection key or press spray preselection key on the multifunction foot control. LED lights up: heating for multifunction handpiece on assistant’s element is preselected. Press cold light preselection key. LED lights up: cold light for multifunction handpiece on assistant’s element is preselected. Storage Press LP/AP key with instrument picked up until a signal is heard. Cold light intensity is constant. 11 KaVo Primus® 1058 S/TM/C/G. Setting the time. Press clock key until0a signal is heard. 0 LP AP SP set hours Set hours by means of the plus key and the minus key. LP AP 1 2 2 Press clock key again briefly. SP set minutes Set minutes. Press clock key again briefly. set seconds zero 0 Set seconds to zero. LP 0 AP LP AP SP Saving: 2 key until a signal is heard. Press clock Timer timer 2 Timer start Press timer key. The set time starts to run. SP 0 After the time has elapsed, 0a signal is heard 0 Setting the timer: LP LP LP is heard. AP Press timer 2 key until a signal AP AP 1 2 2 Set desired time using the plus key and the minus key. Max. 8 minutes, 30 seconds SP Saving: SP is heard. SP Press timer key until a signal 12 set timer KaVo Primus® 1058 S/TM/C/G. Handling function keys- Control/Display Setting a function. Press key F1 or F2 until a signal is heard. 0 LP 0 program F1 Select the function using the plus and LP minus keys AP 1 AP 2 SP SP 00 bell-relais (1s) 2 Save the function. Press key F1 or F2 until a signal is heard. Calling up the function. The saved function is triggered if the F1 or F2 key is pressed briefly. 14 functions are preprogrammed. 13 KaVo Primus® 1058 S/TM/C/G. Hydroclean-function. Control/Display Calling up function. Press LP/AP key (Preparation). LEDs flash for about four seconds. Press the key bowl rinse. The Hydroclean-function is started. Press again for switching off the function. This function activates the suction machine and causes the suction lines (from filter housing to separation system) to be flushed with clean water fully automatically for approx. 150 seconds. Bowl rinsing is switched on and off several times. 14 KaVo Primus® 1058 S/TM/C/G. Refilling Oxygenal. Control/Display When a tone is heard at one second intervals (10 tones), the storage tank is empty. 0 Remove mouthwash glass filler and cover. Fill with one bottle of Oxygenal (max. 1 litre). When a tone is heard at one second intervals (10 tones), the storage tank is full. Stop refilling immediately. Do not fill the central hole (mouthwash glass drain). 15 10 sec 20 sec... KaVo Primus® 1058 S/TM/C/G. Instrument rinsing programme Control element/display (only in conjunction with the intensive disinfection kit) Press the LP/AP button (AP-LEDs flash for 4 seconds). While they are flashing, press the Spray button. Place the sterilisation attachment on the ceramic bowl or insert it in the glass bowl. COMFORTbase Place the instruments in the sterilisation set on the spittoon. Press the foot pedal to display the time for rinsing the instruments and triple or multifunction handpiece. The standard value for rinsing program is 02:00:00 minute per instrument. Adjust the time with the "Chair up" and "Chair down" keys from 0:00 to 8:30 minutes. Start the instrument rinsing program: Press the Spray key when turning on the device again, e.g. on the following day. 0 End of the instrument rinsing program: The spray air LED flashes yellow, the spray water LED flashes green, power LED flashes green, and service LED flashes yellow. Set down the instruments. LP 1 AP SP End the rinsing program: The rinsing program can be immediately terminated by pressing the Spray key again or turning the device off and on. 16 2 KaVo Primus® 1058 S/TM/C/G. Intensiv sterilisation (optional) Control element/display Start intensive sterilisation without an automatic request: M Press the button when the instruments are mounted until you hear a beep and the LED flashes (once every second). Request for intensive disinfection (LED flashes at two second intervals) M Place the instruments in the sterilisation set on the spittoon. M I COMFORTbase I Start the function. Press the key. Intensive sterilization runs automatically. M 0 LP End of intensive sterilisation. 1 AP SP After rinsing the instruments with a high oxygenal concentration, the start of the dwell time is signalled with a 4 second beep. The dwell time is 30 min. During this time, the device can be turned off. After intensive sterilisation is over, the Device ON LED and the service LED flash. After placing the instruments in their holders, the device is ready to operate 17 2 KaVo Primus® 1058 S/TM/C/G. Skip exposure phase Control element/display Function. 0 Intensive sterilisation occurs in step 7-4.5 (before the dwell time): Turn the device off and on. The intensive sterilisation switches to step 3.6. The automatic rinsing process starts. Set down the instruments after the rinsing process. 1 2 SP 0 Intensive sterilisation is in step 4 (dwell time): Simultaneously press and hold the intensive sterilisation key and hydrocolloid key. 1 2 SP Simultaneously press the foot button until you hear a signal. The intensive sterilisation switches to step 3.6. Set down the instruments after the rinsing process. + M This function is necessary when intensive sterilisation has I already started, and the treatment unit has to be used (for example: in emergencies, in hospitals, etc.). After intensive sterilisation, the oxygenal concentration is higher. The automatic rinsing process (duration: about 6 min.) may therefore not be terminated. After the rinsing process, the concentration is normal. 18 I KaVo Primus® 1058 S/TM/C/G. Warnings Display Safety cut-outs. A safety cut-out is active if one of the LEDs of the automatic position keys flashes. Assignment: Backrest SP Seat Underside chair parallelogram Vacu-Stopp Stirrup on multifunction foot control LP/AP Assistant’s element AP1 Patient’s part swivelled over the patient’s chair AP2 Microswitch (Dentist`s element C) AP0 The safety cut-outs immediately stop the respective chair movements. 19 KaVo Primus® 1058 S/TM/C/G. Further warnings. Display Oxygenal tank empty. A signal tone is heard at ten second intervals. Oxygenal tank full. Ten signal tones at one second intervals. Amalgam separator. 0 A signal is heard. The Service LED flashes. This only indicates a fault in the amalgam separator. Detailed information is given on the display of the amalgam separator and in the associated operating instructions. LP 1 AP 2 SP Bowl suction valve overfilled. 0 Service LED flashes for 10 seconds. Emergency off switch for bowl suction valve is operated. Water for bowl rinse and mouthwash glass filler is switched off. LP 1 AP SP 20 2 KaVo Primus® 1058 S/TM/C/G. Functions on multifunction footcontrol Function with instruments removed. Function with instruments placed in holder or instrument removed and stirrup switch* pressed once. Stirrup carrying handle with switch for safety cut-out preselection counterclockwise Cross-switch for operating the patient’s chair Patient’s chair - automatic postion Patient’s chair - automatic postion Air blast Spray preselection Foot switch for activating and for speed/ intensity regulation of the instruments * Chair functions are switched off again by operating the foot switch. 21 KaVo Primus® 1058 S/TM/C/G. 22 KaVo Primus® 1058 S/TM/C/G. Memospeed Display Level switching/ Saving Minus Plus Timer Time Function 2 Function 1 Dentist’s unit X-ray viewer Seat up/Automatic position 0 Last position / Automatic position preselection / Saving Dentist’s level 2/ Service LED Mouthwash glass filler Bowl flush 0 LP 1 AP 2 M SP Dentist’s level 1/ Unit On indicator Backrest down Treatment position 1 Backrest up Treatment position 2 Seat down Rinse position Spray preselection Instrumenten light 23 R/L motor rotation direction 1.001.6813 En 20090311-05 en KaVo Dental GmbH · D 88400 Biberach/Riß · Telefon +49 7351 56-0 · Fax +49 7351 56-1488 · www.kavo.com 24