KaVo PRIMUS 1058 S/TM/C/G
Brief operating
instructions.
KaVo Primus® 1058 S/TM/C/G.
These brief operating instructions cover only the essential control functions.
They do not replace the standard operating instructions which form part of
the delivery. It is essential to consult the standard operating instructions in
order to avoid faults and damage.
Patient´s chair
Control
Save automatic position.
Set desired chair position using keys
or
using multifunctional foot
control when instruments are
replaced in the holder.
Press key LP/AP briefly.
LEDs flash for about 4 seconds.
Press required key for about 4
seconds until a signal is heard.
2
+
Keep foot switch and AP key
depressed and also press desired
key on the dentist's or assistant's
element until a signal is heard.
+
Assignment of the AP keys on
the multifunctional foot control.
KaVo Primus® 1058 S/TM/C/G.
Dental chair
Control
Call up automatic position.
Assistant’s element and
Comfort assistant’s element:
Press LP/AP key briefly.
LEDs flash for about four seconds.
During this time, press desired
key AP briefly.
Standard assistant’s element :
Press joystick briefly.
LEDs flash for about four seconds.
During this time, move joystick
in the appropriate direction.
or
with instrument removed,
call up automatic position.
For safety, when the spittoon is swivelled in, the
chair movement is limited.
3
KaVo Primus® 1058 S/TM/C/G.
Choose dentist’s level 1/2.
Control/Display
When instruments are set down
2
Switching on the multifunction foot control:
+
Keep the foot switch depressed and
additionally operate the stirrup switch.
or
1
Switching
2 on the Memospeed control:
E123
Keep level preselection key depressed
until a signal is heard.
0
Dentist’s level 1
LP
AP
1
2
M
SP
0
Dentist’s level 2
LP
AP
1
2
M
SP
4
KaVo Primus® 1058 S/TM/C/G.
Instruments
Control/Display
Set cooling state.
Remove instrument.
or
Cooling state: Spray
Storage (without installed Memospeed):
Press LP/AP key with instrument
picked up until a signal is heard.
2 Storage (with installed Memospeed):
Press level preselection key
with instrument picked up
until a signal is heard.
E123
5
KaVo Primus® 1058 S/TM/C/G.
Instruments
Control/Display
Set cold light on/off
and cold light intensity.
Remove instruments.
Press cold light preselection key briefly.
Cold light: On
Intensity:
(without installed Memospeed)
Keep cold light preselection key
depressed.
min.
1 2
1x
3
4
5
6
7
8
max.
9 10
10x
Storage:
Press LP/AP key with instrument
picked up until a signal is heard.
6
KaVo Primus® 1058 S/TM/C/G.
0
LP
0
AP
LP
AP
SP
Setting the cold light
intensity.
Control/Display
Level E, 1, 2, 3
(with installed Memospeed)
2
Remove instruments.
Press level preselection key
until a signal is heard.
E123
2
E123
Press level preselection key 2 x briefly.
SP
00The cold light intensity can be set
lux:
in 10 steps using the plus key or the
minus key.
LP
LP
AP
AP
22
SP
SP
0
lux:
LP
AP
Storage:
2
Press level preselection key
until a signal is heard.
E123
SP
7
KaVo Primus® 1058 S/TM/C/G.
Speed setting turbine.
Control/Display
(with installed Memospeed) Level 1, 2, 3
Remove
2 instrument.
E123
Press level preselection key
until a signal is heard.
It is possible to switch between
maximum and manual mode using
0 the minus key.
0 the plus key and
turbine: maximum
Maximum mode:
LP The turbine isLP
always operated
at
maximum
speed
at every position
AP
1of the foot switch.
2
2AP
Manual mode:
A speed between 160,000 min-1 (left stop)
min-1 (right stop) can be
SP and 300,000 SP
selected by means of the foot switch on
the multifunction foot control.
turbine: manuell
Storage:
2
Press level preselection key
until a signal is heard.
E123
Setting the Motor reverse.
Remove motor from the support.
Press motor reverse key
or
press motor reverse key on the
multifunction foot control.
LED lights up: Motor reverse has been
preselected.
or
Saving:
Press LP/AP key with instrument picked up
until a signal is heard.
8
0
KaVo Primus® 1058 S/TM/C/G.
LP
Speed setting motor/
0
2
Intensity
setting PIEZOlux/
COMFORTdrive 200 XD
AP
SP
Control/Display
E123
LP
0 (with installed Memospeed)
Level 1, 2, 3
1
AP
LP Remove motor/PIEZOlux
2
Motor
minimum:
key
AP Press level preselection
2
until a signal is heard.
0
SP
minimum:
2
0
SP Set the intensity using the
plus key and minus key.
1
LP
E123
AP
LP
AP motor
2
0
Minimum mode:
K motor:
400 min-1
0 KL motor:
2000 min-1
SP
1
SP
2
maximum:
maximum:
PIEZOlux/COMFORTdrive 200 XD
AP
2
minimum:
2
PIEZOlux/COMFORTdrive 200 XD
2
LP
Maximum mode:
LP K motor and KL motor: 40000 min-1
AP
minimum ≤ maximum
0
SP
minimum:
Minimum: 1/Maximum: 10
0 The step size is 0.25.
SP
1
LP
E123
AP
COMFORTdrive 200 XD
LP Min 1:
30.000 min-1
-1
AP Max 10: 200.000 min
2
maximum:
2
Storage:
minimum ≤ maximum
SP
maximum:
2
Press level preselection key
SP until a signal is heard.
E123
9
KaVo Primus® 1058 S/TM/C/G.
ON/OFF functions of heating
and cold light on the multifunction handpiece
Control/Display
Setting on dentist’s element
mf-syringe
Remove multifunction handpiece
from the holder.
Holder switch is operated.
Press spray preselection key
or
press spray preselection key on the
multifunction foot control.
or
LED lights up: heating and cold light
for multifunction handpiece on dentist’s
element are preselected.
Storage
Press LP/AP key with instrument
picked up until a signal is heard.
Cold light intensity is constant.
10
KaVo Primus® 1058 S/TM/C/G.
ON/OFF functions of heating
and cold light on the multifunction handpiece
Control/Display
Setting on Comfort assistant’s element
mf-assist
Remove multifunction handpiece
from the holder.
Press air or water key on the
multifunction handpiece briefly.
or
Press spray preselection key
or
press spray preselection key on the
multifunction foot control.
LED lights up: heating for multifunction handpiece on assistant’s
element is preselected.
Press cold light preselection key.
LED lights up: cold light for multifunction handpiece on assistant’s
element is preselected.
Storage
Press LP/AP key with instrument
picked up until a signal is heard.
Cold light intensity is constant.
11
KaVo Primus® 1058 S/TM/C/G.
Setting the time.
Press clock key until0a signal is heard.
0
LP
AP
SP
set hours
Set hours by means of the plus key
and the minus key. LP
AP
1 2
2
Press clock key again briefly.
SP
set minutes
Set minutes.
Press clock key again briefly.
set seconds zero
0
Set seconds to zero.
LP
0
AP
LP
AP
SP
Saving:
2 key until a signal is heard.
Press clock
Timer
timer
2
Timer start
Press timer key. The set time starts to run.
SP 0 After the time has elapsed, 0a signal is heard
0
Setting the timer:
LP
LP
LP
is heard.
AP Press timer
2 key until a signal
AP
AP
1 2
2
Set desired time using the plus key and
the minus key. Max. 8 minutes, 30 seconds
SP Saving:
SP is heard.
SP Press timer key until a signal
12
set timer
KaVo Primus® 1058 S/TM/C/G.
Handling function keys-
Control/Display
Setting a function.
Press key F1 or F2 until a signal is heard.
0
LP
0
program F1
Select the function using the plus
and LP
minus keys
AP
1
AP
2
SP
SP
00
bell-relais (1s)
2
Save the function.
Press key F1 or F2 until a signal is heard.
Calling up the function.
The saved function is triggered if
the F1 or F2 key is pressed briefly.
14 functions are preprogrammed.
13
KaVo Primus® 1058 S/TM/C/G.
Hydroclean-function.
Control/Display
Calling up function.
Press LP/AP key (Preparation).
LEDs flash for about four seconds.
Press the key bowl rinse.
The Hydroclean-function is started.
Press again for switching off
the function.
This function activates the suction machine and
causes the suction lines (from filter housing to
separation system) to be flushed with clean water fully
automatically for approx. 150 seconds. Bowl rinsing is
switched on and off several times.
14
KaVo Primus® 1058 S/TM/C/G.
Refilling Oxygenal.
Control/Display
When a tone is heard at one second intervals
(10 tones), the storage tank is empty.
0
Remove mouthwash glass filler and cover.
Fill with one bottle of Oxygenal (max. 1 litre).
When a tone is heard at one second intervals
(10 tones), the storage tank is full.
Stop refilling immediately.
Do not fill the central hole
(mouthwash glass drain).
15
10 sec
20 sec...
KaVo Primus® 1058 S/TM/C/G.
Instrument rinsing programme
Control element/display
(only in conjunction with the intensive disinfection kit)
Press the LP/AP button (AP-LEDs flash
for 4 seconds). While they are flashing,
press the Spray button.
Place the sterilisation attachment on the
ceramic bowl or insert it in the glass bowl.
COMFORTbase
Place the instruments in the sterilisation
set on the spittoon.
Press the foot pedal to display the time for
rinsing the instruments and triple or
multifunction handpiece.
The standard value for rinsing program
is 02:00:00 minute per instrument.
Adjust the time with the "Chair up" and
"Chair down" keys from 0:00 to 8:30 minutes.
Start the instrument rinsing program:
Press the Spray key when turning on the
device again, e.g. on the following day.
0
End of the instrument rinsing program:
The spray air LED flashes yellow,
the spray water LED flashes green,
power LED flashes green, and service
LED flashes yellow. Set down the instruments.
LP
1
AP
SP
End the rinsing program: The rinsing program
can be immediately terminated by pressing
the Spray key again or turning the device off and on.
16
2
KaVo Primus® 1058 S/TM/C/G.
Intensiv sterilisation (optional) Control element/display
Start intensive sterilisation without an
automatic request:
M
Press the button when the instruments
are mounted until you hear a beep and
the LED flashes (once every second).
Request for intensive
disinfection
(LED flashes at two
second intervals)
M
Place the instruments in the sterilisation
set on the spittoon.
M
I
COMFORTbase
I
Start the function.
Press the key. Intensive sterilization
runs automatically.
M
0
LP
End of intensive sterilisation.
1
AP
SP
After rinsing the instruments with a high oxygenal
concentration, the start of the dwell time is signalled
with a 4 second beep.
The dwell time is 30 min.
During this time, the device can be turned off. After intensive
sterilisation is over, the Device ON LED and the service LED flash.
After placing the instruments in their holders, the device is ready
to operate
17
2
KaVo Primus® 1058 S/TM/C/G.
Skip exposure phase
Control element/display
Function.
0
Intensive sterilisation occurs in
step 7-4.5 (before the dwell time):
Turn the device off and on. The intensive
sterilisation switches to step 3.6.
The automatic rinsing process starts.
Set down the instruments after
the rinsing process.
1
2
SP
0
Intensive sterilisation is in step 4
(dwell time): Simultaneously press and
hold the intensive sterilisation key and
hydrocolloid key.
1
2
SP
Simultaneously press the foot button
until you hear a signal. The intensive
sterilisation switches to step 3.6.
Set down the instruments after
the rinsing process.
+
M
This function is necessary when intensive
sterilisation has
I
already started, and the treatment unit has to be used
(for example: in emergencies, in hospitals, etc.).
After intensive sterilisation, the oxygenal concentration is
higher. The automatic rinsing process (duration: about 6
min.) may therefore not be terminated. After the rinsing process,
the concentration is normal.
18
I
KaVo Primus® 1058 S/TM/C/G.
Warnings
Display
Safety cut-outs.
A safety cut-out is active if one of the LEDs
of the automatic position keys flashes.
Assignment:
Backrest
SP
Seat
Underside chair parallelogram
Vacu-Stopp
Stirrup on multifunction
foot control
LP/AP
Assistant’s element
AP1
Patient’s part swivelled over
the patient’s chair
AP2
Microswitch (Dentist`s element C) AP0
The safety cut-outs immediately stop the respective
chair movements.
19
KaVo Primus® 1058 S/TM/C/G.
Further warnings.
Display
Oxygenal tank empty.
A signal tone is heard at ten second intervals.
Oxygenal tank full.
Ten signal tones at one second intervals.
Amalgam separator.
0
A signal is heard.
The Service LED flashes.
This only indicates a fault in the amalgam
separator. Detailed information is given on
the display of the amalgam separator and
in the associated operating instructions.
LP
1
AP
2
SP
Bowl suction valve overfilled.
0
Service LED flashes for 10 seconds.
Emergency off switch for bowl suction valve
is operated. Water for bowl rinse and mouthwash glass filler is switched off.
LP
1
AP
SP
20
2
KaVo Primus® 1058 S/TM/C/G.
Functions on multifunction footcontrol
Function with instruments removed.
Function with instruments placed in holder or instrument removed and
stirrup switch* pressed once.
Stirrup carrying handle
with switch for safety cut-out
preselection
counterclockwise
Cross-switch for
operating the
patient’s chair
Patient’s chair
- automatic
postion
Patient’s chair
- automatic postion
Air blast
Spray
preselection
Foot switch for activating and for speed/
intensity regulation of the instruments
* Chair functions are switched off again by operating the
foot switch.
21
KaVo Primus® 1058 S/TM/C/G.
22
KaVo Primus® 1058 S/TM/C/G.
Memospeed
Display
Level switching/
Saving
Minus
Plus
Timer
Time
Function 2
Function 1
Dentist’s unit
X-ray viewer
Seat up/Automatic
position 0
Last position /
Automatic position
preselection / Saving
Dentist’s level 2/
Service LED
Mouthwash
glass filler
Bowl flush
0
LP
1
AP
2
M
SP
Dentist’s level 1/
Unit On
indicator
Backrest down
Treatment position 1
Backrest up
Treatment position 2
Seat down
Rinse position
Spray preselection
Instrumenten light
23
R/L motor rotation
direction
1.001.6813 En 20090311-05 en