- 59 FAILURE OF ALTERNATING CURRENT (AC) SUPPLY FROM THE MOTOR ALTERNATOR OR BATTERY CHARGER INOPERATIVE light occur light brake The alarm circuit will be energised causing the blue to shine and alarm bell to sound should the failure on the motor side of the alternator, then the red fault will also shine with the accelerating and/or regenerative handle in the 'off' position. The following items are to be checked:- 1. Line voltage is more than 1100 volts. Note: If the line voltage is less than 1100 volts then the no volt relay will function. 2. Accelerating and regenerative brake handles are in the 'off' position. 3. Press the fault reset button if the red indicator light is shining. 4. Motor alternator (AC) supply circuit breaker is not tripped. 5. Battery charger circuit breaker is not tripped. 6. Supply indicator circuit breaker is not tripped. When the defect cannot be rectified to silence the alarm and extinguish the blue light, isolate the motor alternator by turning off the supply isolate switch. Under these conditions, the motor alternator is a failure, the traction motor blowers and starting resistor blower fans will not operate. Notching is only possible in positions 1 to 3 of the accelerating handle and the locomotive can only be operated up to full series. The ammeter readings should be controlled during notching in resistance to a maximum of 400 amps which will restrict operation to light locomotive running only. The notching of starting resistances out of circuit must be completed within sixty (60) seconds to prevent overheating of the resistances without the blower fans. Should this period be exceeded, then power to the traction motors is interrupted and cannot be re-applied for a period of three (3) minutes.