Download Exsulite Specification & Installation Manual
Transcript
2.2.4 Over Roof Set Out – Exsulite Angled Starter Piece (SP1) The Exsulite Angled Starter Piece (SP1) is to be installed horizontally above roof section and fixed to each stud 50mm & 150mm from top edge NOTE: Ensure fixings do not penetrate into metal flashing and ensure that the flat or pitched roof has had the correct flashing installed by others which is fit for purpose and is sloping away from the wall cladding When installing the Exsulite Angled Starter Piece (SP1) channel above a deck, flat or pitched roof, ensure a gap of is left between the bottom of the Exsulite Angled Starter Piece (SP1) and the finished level. 1 1. Install Exsulite Cavity Spacers with galvanised clouts on all studs to top edge of roof flashing. 2 B A 2. Determine height of Exsulite Angled Cavity Starter Piece (SP1). A) Minimum 25mm gap for tiled roofs and 5-20mm for metal roofs. B) Building wrap must terminate 20mm above 3mm gap between panel and roof flashing. Approximately 3mm gap between back of panel and metal roof flashing. NOTE: Refer to Exsulite Construction Drawings EXS804A, EXS805A, EXS805B, for clarity. Exsulite Specification & Installation Manual Version 2 · 01 July 2015 27