Download Solution Ultima 844/862/880 Installation Manual

Transcript
Solution Ultima 844/862/880
212
Installation Manual
Normally Open, One Shot Low With Alarm
6
This one shot polarity is normally open circuit and will switch to zero volts when the event occurs.
The output will switch back to open circuit once the one shot time has expired, when the event has
returned to normal or when the system has been disarmed.
This polarity is ideally suited for the operation of strobe lights as they can be programmed (Up to 99
hours) to reset and prevent them from burning out or becoming annoying to others from prolonged
operation.
Normally Open, Latching Low
7
This polarity is normally open circuit and will switch to zero volts when the event occurs. The output
will switch back to open circuit once the 7 button on the remote codepad is held down until two
beeps are heard. Time parameters are not applicable to this polarity.
Normally Low, Going Open
8
This polarity is normally zero volts and will switch to open circuit when the event occurs. The output
will switch back to zero volts when the event has restored. Time parameters are not applicable to this
polarity.
Normally Low, Pulsing Open
9
This polarity is normally zero volts and will switch to pulsing open circuit when the event occurs.
The output will switch back to zero volts when the event has restored. Time parameters vary the
"Off" time of the pulse.
Normally Low, One Shot Open
10
This one shot polarity is normally zero volts and will switch to open circuit when the event occurs.
The output will switch back to zero volts when the time parameter has expired. This one shot time
setting will always run its full duration and cannot be manually reset.
Normally Low, One Shot Open With Retrigger
11
This one shot polarity is normally zero volts and will switch to open circuit when the event occurs.
Every time the event occurs, it will restart the one shot timer. The output will switch back to zero
volts once the one shot time has expired.
Normally Low, One Shot Open With Reset
12
This one shot polarity is normally zero volts and will switch to open circuit when the event occurs.
The output will switch back to zero volts when the one shot time has expired or when the event has
returned to normal. This means the one shot timer can be shortened regardless of the time setting.
Normally Low, One Shot Open With Alarm
13
This one shot polarity is normally zero volts and will switch to open circuit when the event occurs.
The output will switch back to zero volts when the one shot time has expired, when the event has
returned to normal or when the system has been disarmed. This means that the one shot timer can be
shortened regardless of the time setting.
Normally Low, Latching Open
14
ISSUE120.DOC
This polarity is normally zero volts and will switch to open circuit when the event occurs. The output
will switch back to zero volts once the 7 button on the remote codepad has been held down until two
beeps are heard. Time parameters are not applicable to this polarity.
Electronics Design and Manufacturing Pty Limited