Download Handleiding Betriebsanleitung Operating instructions
Transcript
Dismount the belt protector (r). Unscrew the fastening bolts on the motor sledge. Remove the V-belt. Place the motor at the right distance from the pump. Make sure that the pulley of the motor runs in the same line parallel with the flywheel on the pump (see drawing). Tighten the fastening bolts and replace the Vbelt. Worn V-belts should be replaced by new ones with the same size. After +/- 10 operating hours tighten the head bolts of the V-belt driven piston compressors according to following table: Tightening Compressor Pump Bolt Tightening moment min. moment max. (Nm) (Nm) HL/HK 310- 2800/3800 M8 22,45 27,43 100 HL/HK 425- 2800/3800 M8 22,45 27,43 100 HK 425-200 2800/3800 M8 22,45 27,43 HK 600-200 3800 M8 22,45 27,43 HK 700-300 5900/B M10 45,28 55,34 HK 1000-500 6000 M10 45,25 55,34 HK 1000-500 7000 M12 77,10 94,23 (version >01-12-2010) Note: Regular maintenance of your compressor will increase durability and reliability. ATTENTION ! Checking the oil level and refreshing the oil does not apply to the oil free models HLO 110/6, HLO 200/25, HLO 215/25, HLO 300/50 and HLO 300/100. 28