14.12
Position controller enable
RW
Ú
0 or 1
Bit
Ö
0
When this parameter is set at 1, the MD29 indicates if the Clock Task
over-runs.
14.13
I/O link synchronisation source
RW
Ú
0 or 1
Bit
Ö
0
When this parameter is set at 1, the MD29 indicates if the Encoder Task
over-runs.
14.14
Encoder time base select
RW
Ú
0 or 1
Bit
Ö
0
This parameter sets the timebase for the ENCODER Task.
0 = 5ms
1 = 2.5ms
14.15
Reserved
RW
Ú
14.16
0 or 1
Ö
0
Flash store request
RW
Ú
Bit
0 or 1
Bit
Ö
0
Set to 1 to save the PLC parameter registers (.PX% and -QX%) into the
non volatile memory of the MD29. The parameter value automatically
returns to 0.
See the MD29 User Guide for more details.
14.17
RS232 drive - drive comms enable
RW
Ú
0 or 1
Ö
Bit
0
When set to 1, and the DPL Toolkit communications are disabled, drive
to drive RS232 communications are enabled.
See MD29 User Guide for more details.
Mentor ll User Guide
Issue Number: 14
83