Download INSTALLATION MANUAL
Transcript
Error display OPERATION TIMER ECONOMY lamp lamp lamp (green) (orange) (green) ●(2) ●(2) ●(3) ●(3) ●(4) ●(4) ●(5) ●(5) ●(4) ●(7) ●(2) ●(5) ●(1) ●(2) ●(1) ●(3) ◊ Indoor unit PCB model information error ◊ ◊ ◊ ◊ ◊ ◊ ● ● (8) ◊ ●(5) ●(15) ◊ ●(6) ●(2) ◊ ●(6) ●(3) ◊ ●(6) ●(4) ◊ ● ● (5) ◊ ●(6) ●(10) ◊ ●(7) ●(1) ◊ ●(7) ●(2) ◊ ●(7) ●(3) ◊ ●(7) ●(4) ◊ ●(7) ●(5) ◊ ●(7) ●(6) ◊ ●(7) ●(7) ◊ ● ● (2) ◊ ●(8) ●(3) ◊ ●(8) ●(4) ◊ (8) Description ◊ ◊ ●(7) (6) Error display • Connection unit number error (indoor slave unit) [Simultaneous Multi] • Connection unit number error (indoor unit or branch unit) [Flexible Multi] Master unit, slave unit set-up error [Simultaneous Multi] ●(5) (5) Wired remote controller Error code ●(8) ●(6) ◊ ●(9) ●(4) ◊ Manual auto switch error Room temp. sensor error Indoor unit Heat Ex. Middle temp. sensor error Indoor unit fan motor error OPERATION TIMER ECONOMY lamp lamp lamp (green) (orange) (green) ●(9) ●(5) ◊ ●(9) ●(7) ◊ ●(9) ●(9) ◊ ●(10) ●(1) ◊ ●(10) ●(3) ◊ ●(10) ●(4) ◊ ●(10) ●(5) ◊ ●(13) ●(2) ◊ Display mode Drain pump error Wired remote controller Error code Description Compressor rotor position detection error Outdoor unit fan motor error 4-way valve error Discharge temp. error Compressor temp. error High pressure error Low pressure error Branch boxes error [Flexible Multi] ● : 0.5s ON / 0.5s OFF ◊ : 0.1s ON / 0.1s OFF ( ) : Number of flashing Damper error [Troubleshooting with the indoor unit display] Intake grille error Indoor unit error Outdoor unit main PCB model information error or communication error Inverter error Active filter error, PFC circuit error Trip terminal L error Display PCB microcomputers communication error Discharge temp. sensor error OPERATION indicator lamp (green) TIMER indicator lamp (orange) ECONOMY indicator lamp (green) [Troubleshooting with the wired remote controller display (Option)] If an error occurs, the following display will be shown. (“Er” will appear in the set room temperature display.) Compressor temp. sensor error Outdoor unit Heat Ex. liquid temp. sensor error Error code Outdoor temp. sensor error Suction Gas temp. sensor error • 2-way valve temp. sensor error • 3-way valve temp. sensor error Heat sink temp. sensor error • Sub-cool Heat Ex. gas inlet temp. sensor error • Sub-cool Heat Ex. gas outlet temp. sensor error Liquid pipe temp. sensor error Current sensor error • Discharge pressure sensor error • Suction pressure sensor error • High pressure switch error Trip detection En-12 9319357003-03_IM.indb 12 3/27/2013 2:09:20 PM