Figure 19: Example of Keyswitch Numbering 5.2.5 Generates a Utility Key Event on Open and Close SECTIONS [149] TO [156]: SECOND DIGIT = 4 When option [4] is enabled, a Utility Key Event will be generated whenever the keyswitch input is opened or closed. As a result, the Utility Key Events increase from 32 to 64 events when option [4] is enabled; one event for each state (open and closed). See Table 12 on page 35. This option can be used to activate or deactivate one or more of DGP-848’s PGM outputs. When a keyswitch is defined with the Generate a Utility Key Event on Open and Close option, the Keyswitch Partition Assignment and Keyswitch Options are disabled. To program a Keyswitch to generate a Utility Key Event: 1) 2) Program the Activation Event of a PGM output with the Utility Key Event corresponding to the desired keyswitch (see PGM Programming Table in the Programming Guide). Enable option [4] in the section corresponding to the desired keyswitch. 5.3 Keyswitch Partition Assignment 5.2 Keyswitch Definitions Select one of the keyswitch definitions (also see Figure 18 on page 17): SECTIONS [149] TO [156]: SECOND DIGIT = 1 TO 4 The control panel provides the option of partitioning the security system into two, three, or four completely independent systems. Therefore, each keyswitch must be assigned to one partition as described in Figure 18 on page 17. For more information on Partitioning, refer to section 12.5 on page 36. 5.2.1 Keyswitch Disabled 5.4 Keyswitch Options SECTIONS [149] TO [156]: FIRST DIGIT = 0 Disables keyswitch input. Each keyswitch zone can be programmed with one or more of the options (also see Figure 18 on page 17): 5.2.2 Momentary Keyswitch 5.4.1 Stay/Instant Disarm (Keyswitch) SECTIONS [149] TO [156]: FIRST DIGIT = 1 To arm a partition using the Momentary Keyswitch, turn on the keyswitch for approximately three seconds then turn it off. Repeating this sequence will disarm the system. The selected Keyswitch Option (see section 5.4) determines the type of arming. 5.2.3 Maintained Keyswitch SECTIONS [149] TO [156]: OPTION [4] When option [4] is enabled, the keyswitch can only disarm assigned Stay or Instant armed partitions. The Arm Only Option (see section 5.4.2) must be disabled for this feature to function. When option [4] is disabled, the keyswitch can disarm partitions armed using any arming method. SECTIONS [149] TO [156]: FIRST DIGIT = 2 To arm a partition using the Maintained Keyswitch, turn the switch from the ON to the OFF position. To disarm a partition set the keyswitch in the ON position. In the case of an Arm Only option, the control panel will not perform any action when the switch is in the ON position. The selected Keyswitch Option (see section 5.4) determines the type of arming. 5.4.2 Arm/Disarm (Keyswitch) 5.2.4 Generates a Utility Key Event on Open 5.4.3 Stay Arming (Keyswitch) SECTIONS [149] TO [156]: SECOND DIGIT = 3 When option [3] is enabled, a Utility Key Event will be generated whenever the keyswitch input is opened (see Table 12 on page 35). This option can be used to activate or deactivate one or more of Digiplex’s PGM outputs. When a keyswitch is defined with the Generate a Utility Key Event on Open option, the Keyswitch Partition Assignment and Keyswitch Options are disabled. To program a Keyswitch to generate a Utility Key Event: 1) 2) Program the Activation Event of a PGM output with the Utility Key Event corresponding to the desired keyswitch (see PGM Programming Table in the Programming Guide). Enable option [3] in the section corresponding to the desired keyswitch. 18 Reference & Installation Manual SECTIONS [149] TO [156]: Option [5] ON = Arm Only Option [5] OFF = Arm & Disarm Only one of the arming options (Stay, Force, Instant and Regular) can be selected. SECTIONS [149] TO [156]: OPTION [6] Activating the keyswitch will bypass any zones defined as Stay Zones (see section 4.4.3 on page 14) in the selected partition. All other zones will remain activated. For more information on Stay arming, refer to section 16.1.2 on page 45. 5.4.4 Force Arming (Keyswitch) SECTIONS [149] TO [156]: OPTION [7] Activating the keyswitch will arm the selected partition bypassing any open zones defined as Force Zones (see section 4.4.4 on page 14) at the time of arming. For more information on Force arming, refer to section 16.1.6 on page 45.