Download InStAllAtIOn mAnUAl PARt 2/2
Transcript
Installation manual Part 2/2 SAFERA Power Control Units PCU5-P and PCU4-U v4.1.2 v4.1.2 Eng Eng PCU5-P PCU5-P / PCU4-U / PCU4-U 1 SAFERA Oy Installation Manual SAFERA Power Control Units PCU5-P and PCU4-U Compatibility of Power Control Unit Ⓒ Uncompatible installation may cause false alarms. Power Control Unit for cooktops without oven. SAFERA PCU5-P ✔ ✔ - - Power Control Unit for cookers with oven. SAFERA PCU4-U ✔ ✔ ✔ ✔ ⚐⚐ Install the power control unit Ⓒ so that it is not exposed to moisture. Check that all cables can move freely. ѥѥ Make sure that there is no power supply to the cooker and the oven by removing their fuses. Also ensure that the cooker is switched off. ѥѥ OUT-wires are always energized when the power control unit is connected to the electrical network. If a wire is loose, it must be properly covered. PCU5-P IN OUT PE PE L/N N L L 230V MAX. 25A MICRO DISCONNECTION installation manual 2 INSTALLATION: PCU5-P Power Control Unit for cooktops without oven 1 6 2 3* 4 PE PE L1 L2 5 L1 & L2 7 Connect cooktop with 3-pin plug * Optional water sensor connection 59-79mm 8 73 mm 60 mm 68-80 mm v4.1.2 Eng PCU5-P / PCU4-U 3 Don’t reconnect the power to the cooker yet, see installation manual Part 1/2 for next steps. SAFERA Oy INSTALLATION: PCU4-U Power Control Unit for cookers with oven IN 3 x 4 mm2 OUT 5 x 4 mm2 IN OUT PE PE L/N N L 230V max. 25A Remove the U-bridges between the cooker’s L-inputs: see connection diagram on the right. 2 Couple the protective earth first (PE). max. 16A L max. 16A L 3 Couple the other wires. max. 16A L 4 Don’t reconnect the power to the cooker yet, see installation manual Part 1/2 for next steps. MICRO DISCONNECTION installation manual 1 Total max. 25 A 4