Download Synchronous Servomotors CMP / Operating Instructions / 2006-04
Transcript
Electrical Installation Thermal motor protection 5 5.6 Thermal motor protection Due to the low thermal time constants of the winding, thermal motor protection is only possible when, in addition to a temperature sensor, a current monitoring device (I2t, effective current monitoring) or a motor model for thermal protection, as installed in SEW servo inverters, is activated. KTY temperature sensor Incorrect connection may cause damage to the temperature sensor and the motor winding. Avoid currents > 4 mA in the circuit of the KTY since high self-heating of the temperature sensor can damage its insulation and the motor winding. It is essential to observe the correct connection of the KTY to ensure correct evaluation of the temperature sensor. The characteristic curve in the following figure shows the resistance curve with a measuring current of 2 mA and correct pole connection. R [Ω] 2000 1800 1600 1400 1200 1000 800 600 400 200 0 -40 -20 0 20 40 60 80 100 120 140 160 180 200 ϑ [°C] 50927AXX Figure 8: Resistance of the KTY sensor depending on the motor temperature For detailed information on connecting the KTY, refer to the contact assignments of the resolver/encoder cable. Observe the correct polarity. 28 Operating Instructions – CMP Synchronous Servomotors