Download User manual - European Commission

Transcript
EU Ecolabel
Hard Coverings User Manual
CRITERION 3: FINISHING OPERATIONS (FOR NATURAL PRODUCTS
ONLY)
3 Emission to air and water (enclosed documentation required)
Particulate emission to air
If PM10 > 150 µg/Nm3 the applicant cannot go on
Styrene emission to air
If > 210 mg/Nm3 the applicant cannot go on
Water recycling ratio
If Recycling ratio=
Waste Water Recycled
⋅ 100
Total Water Leaving the Process
≥90% the
applicant can’t go on.
Suspended solid emission to
water
If > 40 mg/l the applicant cannot go on
Cd emission to wat
If > 0,015 mg/l the applicant cannot go on
Cr(VI) emission to water
If > 0,15 mg/l the applicant cannot go on
Fe emission to water
If > 1,5 mg/l the applicant cannot go on
Pb emission to water
If > 0,15 mg/l the applicant cannot go on
43