Optidrive ODE-2 User Guide Revision 3.20 Terminal Mode P-12=0, P-15=3 Terminal Mode P-12=0, P-15=4 +24 Volt Run (Enable) Run (Enable) Run Forward Local / Remote (Hand / Auto) Remote (Auto) Reference External Trip Stop Run Reverse + 10 Volts + 10 Volts + 10 Volts Reference Local (Hand) Reference Reference 0 Volts 0 Volts 0 Volts Analog speed input with 1 preset speed and motor thermistor trip Local or remote analog speeds (2 analog inputs) Push button fwd/rev/stop with fast stop using 2nd deceleration ramp Keypad Mode (P-12 = 1 or 2) P-15 Digital input 1 (T2) 0, 5, Open: Stop (disable) 8..12 Closed: Run (enable) Open: Stop (disable) 1 Closed: Run (enable) Open: Stop (disable) 2 Closed: Run (enable) Digital input 2 (T3) Closed : remote UP pushbutton Digital input 3 (T4) Closed : remote DOWN push-button Analog input (T6) Open : Forward +24V : Reverse No effect No effect No effect Closed : remote UP pushbutton Closed : remote DOWN push-button Open : Keypad speed ref +24V : Preset speed 1 3 1) Open: Stop (disable) Closed: Run (enable) Closed : remote UP pushbutton External trip input : Open: Trip, Closed: Run Closed : remote DOWN push-button 4 Open: Stop (disable) Closed: Run (enable) Closed : remote UP pushbutton Open : Keypad speed ref Closed : Analog input 1 Analog input 1 6 1) Open: Stop (disable) Closed: Run (enable) Open : Forward run Closed : Reverse run External trip input : Open: Trip, Closed: Run Open : Keypad speed ref +24V : Preset speed 1 7 Open: Forward Stop Closed: Forward Run Open: Reverse Stop Closed: Reverse Run External trip input : Open: Trip, Closed: Run Open : Keypad speed ref +24V : Preset speed 1 Comments Speed reference = PI Controller Output Connect external motor thermistor PTC type or similar to digital input 3 Connect external motor thermistor PTC type or similar to digital input 3 Closing digital inputs 1 and 2 together carries out a fast stop (P-24) Example Wiring Keypad Mode P-12=1 or 2, P-15=0 +24 Volt Run (Enable) Increase Speed Reduce Speed + 10 Volts Forward / Reverse 0 Volts Remote push button speed control with fwd/rev NOTE By default if the enable signal is present the drive will not Enable until the START button is pressed. To automatically enable the drive when the enable signal is present set P-31 = 2 or 3. This then disables the use of the START & STOP buttons www.invertekdrives.com 23 Analog and Digital Input Configurations +24 Volt 7 +24 Volt Analog / Preset 1 7.2. Terminal Mode P-12=0, P-15=11