Transcript
Enduramaxx Outgang Road The Fen Baston Lincolnshire PE6 9PT Tel: 0800 840 4030 Email: [email protected] ENDURAMAXX TROUBLESHOOTING PUMPS GUIDE PROBLEM CAUSE SOLUTION Bad electrical connection Check battery connections Short in wires Pump will not turn on Locked drive Faulty pressure switch Incorrect voltage Fuse Blown Out of product Inlet/ Outlet rube restriction Incorrect voltage Clogged intake valves Clogged intake tube Check condition of wires Replace diaphragm assembly Replace pressure switch assembly Check voltage (±10%) Check and/or replace fuse Refill supply container Tighten fittings/ Replace cracked fittings Remove restriction Check voltage (±10%) Remove obstruction Remove obstruction Worn wobble plate Replace diaphragm assembly Inlet air leak Pump will not prime Worn diaphragm Worn pressure switch Inlet/ Outlet tube restriction Low pressure/ flow Incorrect voltage Clogged intake valves Clogged intake tube Inlet air leak Loose fasteners Pump leaks Pump seals degraded Leak in diaphragm Leak in the system Pump cycles while not Faulty pressure switch spraying Incorrect voltage Air trapped in system Flexible mounting surface Loose pump head Rough operation Compressed base feet Rigid plumbing Replace diaphragm assembly Replace pressure switch assembly Remove restriction Check voltage (±10%) Remove obstruction Remove obstruction Tighten fittings/ Replace cracked fittings Tighten fasteners Replace pump head assembly Replace diaphragm assembly Tighten leaking hose clamps/ fittings Replace pressure switch assembly Check voltage (±10%) Purge the air from the system Mount pump on rigid surface Tighten fasteners Decompress base feet Plumb pump with flexible plumbing