V2 GSM Installation Manual 5.21 INPUT RESTORE VOLTAGE [530] This function sets the restore voltage for each individual input (the V2 GSM onboard inputs only, function not available the RIX inputs). Press the [ or ] keys to scroll to ‘INPUT RESTORE VOLTAGE’ or enter ‘530’. Press B or T to choose the input number or enter the function shortcut number (see below). Press t Press B or T to choose the restore voltage. The choices range from 0V and then increases in 0.5V to 15V. Press t 5.22 LOCAL INPUT DIAGNOSTICS [550] This displays the status of the 6 inputs onboard the V2 GSM. Press the [ or ] keys to scroll to ‘LOCAL INP. DIAGNOSTICS’ or enter ‘550’. Press B or T to choose the input number or enter the function shortcut number (see below). Press t The display shows the voltage of the current status of the input. Press t Shortcut Function Numbers: 551: Diagnostic for input#1 552: Diagnostic for input#2 553: Diagnostic for input#3 554: Diagnostic for input#4 555: Diagnostic for input#5 556: Diagnostic for input#6 Pyronix Ltd Page: 21