Important Notice
Thisȱguideȱisȱdeliveredȱsubjectȱtoȱtheȱfollowingȱconditionsȱandȱrestrictions:ȱ
ThisȱguideȱcontainsȱproprietaryȱinformationȱbelongingȱtoȱRISCOȱGroup.ȱSuchȱ
informationȱisȱsuppliedȱsolelyȱforȱtheȱpurposeȱofȱassistingȱexplicitlyȱandȱproperlyȱ
authorizedȱusersȱofȱtheȱsystem.ȱ
Noȱpartȱofȱitsȱcontentsȱmayȱbeȱusedȱforȱanyȱotherȱpurpose,ȱdisclosedȱtoȱanyȱpersonȱ
orȱfirm,ȱorȱreproducedȱbyȱanyȱmeans,ȱelectronicȱorȱmechanical,ȱwithoutȱtheȱexpressȱ
priorȱwrittenȱpermissionȱofȱRISCOȱGroup.ȱ
Theȱinformationȱcontainedȱhereinȱisȱforȱtheȱpurposeȱofȱillustrationȱandȱreferenceȱ
only.ȱ
Informationȱinȱthisȱdocumentȱisȱsubjectȱtoȱchangeȱwithoutȱnotice.ȱ
Corporateȱandȱindividualȱnamesȱandȱdataȱusedȱinȱexamplesȱhereinȱbelongȱtoȱtheirȱ
respectiveȱowners.ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Allȱrightsȱreserved.ȱȱ
”ȱ2010ȱRISCOȱGroupȱ
ȱ
Marchȱ2010ȱ
Page 2
AgilityȱUserȱManualȱ
ȱ
Table of Contents
Chapterȱ1ȱȬȱIntroduction.............................................................................................................................5ȱ
1.1ȱMainȱFeatures .....................................................................................................................................5ȱ
1.2ȱAgilityȱArchitecture...........................................................................................................................6ȱ
1.3ȱUserȱOperatingȱTools ........................................................................................................................7ȱ
1.4ȱStatusȱIndications...............................................................................................................................8ȱ
LEDȱIndicators................................................................................................................................8ȱ
StatusȱButtonȱ/ȱServiceȱCallȱ(Listenȱ&ȱTalk)...............................................................................9ȱ
VoiceȱMessaging.............................................................................................................................9ȱ
SMSȱMessaging...............................................................................................................................9ȱ
EmailȱMessaging ............................................................................................................................9ȱ
SoundȱIndications ........................................................................................................................10ȱ
Chapterȱ2ȱȬȱLocalȱSystemȱOperation......................................................................................................11ȱ
2.1ȱArmingȱyourȱsystem .......................................................................................................................11ȱ
Awayȱ(Full)ȱarming..................................................................................................................11ȱ
Stayȱ(Home)ȱarming.................................................................................................................12ȱ
Partitionȱarming .......................................................................................................................12ȱ
ForceȱArming ............................................................................................................................13ȱ
ArmingȱwithȱtroublesȱinȱtheȱSystem .....................................................................................13ȱ
2.2ȱDisarmingȱyourȱsystem...................................................................................................................14ȱ
Systemȱdisarming.....................................................................................................................14ȱ
Partitionȱdisarming ..................................................................................................................15ȱ
Duressȱdisarming .....................................................................................................................15ȱ
DisarmingȱafterȱanȱAlarm .......................................................................................................15ȱ
Resettingȱafterȱanȱalarm ..........................................................................................................16ȱ
AntiȱCodeȱReset ...................................................................................................................16ȱ
InstallerȱReset .......................................................................................................................16ȱ
2.3ȱSendingȱaȱPanicȱAlarm....................................................................................................................17ȱ
Chapterȱ3ȱȬȱRemoteȱSystemȱOperation..................................................................................................18ȱ
3.1ȱRemoteȱPhoneȱOperation ...............................................................................................................18ȱ
RemotelyȱAccessingȱtheȱSystem ................................................................................................18ȱ
VoiceȱOperationsȱMenu ..............................................................................................................18ȱ
ReceivingȱCallsȱfromȱtheȱSystem ...............................................................................................19ȱ
AcknowledgeȱMenu ....................................................................................................................20ȱ
BiȬdirectionalȱCommunication...................................................................................................20ȱ
3.2ȱSMSȱOperation .................................................................................................................................21ȱ
SMSȱRemoteȱControl ...................................................................................................................21ȱ
SMSȱConfirmationȱMessage .......................................................................................................22ȱ
Chapterȱ4ȱȬȱUserȱFunctionsȱandȱSettings ..............................................................................................23ȱ
4.1ȱUserȱCodes ........................................................................................................................................23ȱ
4.2ȱProximityȱTags .................................................................................................................................25ȱ
4.3ȱDefiningȱFollowȱMeȱDestinations .................................................................................................26ȱ
4.4ȱScheduler...........................................................................................................................................27ȱ
4.5ȱMacroȱkeys ........................................................................................................................................28ȱ
4.6ȱCompleteȱMenuȱofȱUserȱFunctions ...............................................................................................30ȱ
Page 3
ȱ
AgilityȱUserȱManualȱ
Chapterȱ5ȱȬȱSystemȱSpecifications .........................................................................................................33ȱ
Chapterȱ6ȱȬȱENȱ50131ȱCompliance..........................................................................................................34ȱ
AppendixȱAȱȬȱKeypadȱUserȱOperations................................................................................................35ȱ
CommonȱOperations .............................................................................................................................35ȱ
AdvancedȱOperations ...........................................................................................................................35ȱ
LEDsȱIndication......................................................................................................................................37ȱ
AppendixȱBȱȬȱRemoteȱControlȱUserȱOperations .................................................................................38ȱ
CommonȱOperations .............................................................................................................................38ȱ
AdvancedȱOperations ...........................................................................................................................38ȱ
StatusȱLED/BuzzerȱIndications............................................................................................................39ȱ
ChangingȱRemoteȱControlȱPINȱCode .................................................................................................39ȱ
AppendixȱCȱȬȱEventȱLogȱMessages ........................................................................................................40ȱ
Page 4
AgilityȱUserȱManualȱ
ȱ
Chapter 1 - Introduction
CongratulationsȱonȱyourȱpurchaseȱofȱAgilityȱȬȱRISCOȱGroupȇsȱFlexibleȱWirelessȱSecurityȱ
System.ȱTheȱAgilityȱhasȱbeenȱspecificallyȱdesignedȱtoȱmeetȱaȱwideȱrangeȱofȱsecurity,ȱsafetyȱ
andȱhomeȱautomationȱneedsȱforȱmanyȱresidentialȱandȱcommercialȱapplications.ȱ
Agilityȱisȱdesignedȱtoȱrecognizeȱabnormalȱconditionsȱandȱinformȱtheȱsystemȱofȱtheȱstatusȱ
ofȱanyȱprotectedȱdoor,ȱwindow,ȱhallway,ȱroom,ȱorȱarea.ȱStatusȱinformationȱisȱpresentedȱ
visuallyȱorȱverbally.ȱItȱsupportsȱtheȱcapabilitiesȱofȱcommunicatingȱwithȱaȱCentralȱ
MonitoringȱStationȱorȱtoȱyourȱmobileȱphoneȱusingȱfriendlyȱandȱeasyȱtoȱunderstandȱverbalȱ
messagesȱasȱwellȱasȱSMSȱorȱEȬmailȱmessages.ȱ
Thisȱmanualȱdescribesȱhowȱtoȱoperateȱyourȱsystem.ȱItȱwillȱguideȱyouȱthroughȱ
programmingȱinstructionsȱforȱmainȱsystemȱfeaturesȱasȱwellȱasȱbasicȱarmingȱandȱdisarmingȱ
commandsȱforȱtheȱsystem.ȱ
1.1 Main Features
Upȱtoȱ32ȱwirelessȱzonesȱ(1ȱwayȱorȱ2ȱwayȱ
wirelessȱdetectors)ȱ+ȱ4ȱoptionalȱwiredȱ
zonesȱ(onlyȱwithȱI/Oȱexpander)ȱ
32ȱUserȱcodesȱ+ȱGrandȱMasterȱcodeȱȱ
4ȱfixedȱauthorityȱlevelsȱforȱuserȱȱȱ
Proximityȱtagȱforȱeachȱuserȱȱ
3ȱpartitionsȱ
3ȱwirelessȱkeypadsȱ(1ȱwayȱorȱ2ȱway)ȱȱ
3ȱwirelessȱsirensȱ(internalȱorȱexternal)ȱȱ
8ȱRemoteȱcontrolsȱ(1ȱwayȱorȱ2ȱway)ȱȱ
250ȱEventsȱLogȱȱ
16ȱFollowȱMeȱdestinationsȱȱȱ
4ȱoutputsȱ(I/Oȱexpander)ȱ
XȬ10ȱsupportȱȱ
Page 5
ȱ
ȱ
AgilityȱUserȱManualȱ
1.2 Agility Architecture
YourȱAgilityȱcontrolsȱandȱmonitorsȱaȱvarietyȱofȱsensors,ȱdetectors,ȱandȱcontactsȱplacedȱ
throughoutȱtheȱpremises,ȱwhichȱprovideȱexternal,ȱperimeterȱandȱinternalȱburglaryȱ
protection.ȱTheȱsystemȱisȱsupervised,ȱmeaningȱthatȱtheȱpanelȱchecksȱtheȱstatusȱofȱeachȱ
sensorȱtoȱdetectȱproblems.ȱIfȱtheȱpanelȱdetectsȱtroubleȱitȱwillȱnotifyȱyouȱwithȱbeepsȱandȱ
indicatorȱlightsȱonȱtheȱpanelȱitself.ȱȱ
Theȱfollowingȱdiagramȱshowsȱtheȱcomponentsȱthatȱmakeȱupȱtheȱsystem:ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Page 6
AgilityȱUserȱManualȱ
ȱ
1.3 User Operating Tools
TheȱAgilityȱsystemȱcanȱbeȱoperatedȱusingȱseveralȱdevices,ȱsomeȱofȱwhichȱhaveȱbeenȱ
designedȱasȱbiȬdirectional.ȱIfȱyouȱhaveȱpurchasedȱaȱbiȬdirectionalȱdeviceȱyourȱsystemȱisȱ
capableȱofȱsendingȱaȱreturnȱreplyȱstatusȱindicationȱfromȱtheȱpanelȱtoȱtheȱdeviceȱforȱeachȱ
commandȱthatȱisȱsentȱtoȱit.ȱ
Dependingȱonȱyourȱpurchaseȱyouȱcanȱoperateȱyourȱsystemȱviaȱtheȱfollowing:ȱȱ
2ȬWayȱ8ȱButtonȱRemoteȱControl:ȱȱ
UsingȱtheȱbiȬdirectionalȱ8ȱbuttonȱremoteȱcontrolȱyouȱcanȱarm,ȱdisarm,ȱ
sendȱaȱpanicȱalarm,ȱactivateȱoutputsȱandȱmore.ȱBeingȱbiȬdirectionalȱ
theȱremoteȱcontrolȱreceivesȱaȱreplyȱstatusȱindication,ȱviaȱitsȱ3ȱcoloredȱ
LEDsȱandȱinternalȱbuzzerȱsiren,ȱfromȱtheȱpanelȱforȱeachȱcommandȱ
thatȱitȱhasȱsentȱtoȱtheȱpanel.ȱForȱhigherȱsecurity,ȱcommandsȱcanȱbeȱ
definedȱtoȱbeȱactivatedȱwithȱaȱ4ȱdigitȱPINȱcode.ȱ
ȱ
Agilityȱ2ȬWayȱWirelessȱKeypad:ȱ
ȱ
UsingȱtheȱbiȬdirectionalȱwirelessȱkeypadȱyouȱcanȱprogramȱandȱ
operateȱyourȱsystemȱaccordingȱtoȱyourȱneeds.ȱBeingȱbiȬdirectionalȱtheȱ
keypadȱreceivesȱaȱreplyȱstatusȱindicationȱfromȱtheȱpanelȱforȱeachȱ
commandȱthatȱitȱhasȱsentȱtoȱtheȱpanel.ȱȱToȱuseȱfunctionsȱofȱtheȱ
keypadȱyouȱcanȱuseȱaȱcodeȱorȱaȱproximityȱtag.ȱ
4ȱButtonȱKeyȱfob:ȱ
Usingȱtheȱ4ȱbuttonȱkeyȱfobȱyouȱcanȱarm,ȱdisarm,ȱsendȱaȱpanicȱalarmȱ
andȱactivateȱoutputs.ȱ
ȱ
RemoteȱPhoneȱOperation:ȱȱ
ȱ
Usingȱanyȱremote,ȱtouchȬtoneȱphoneȱyouȱcanȱperformȱremoteȱ
operationsȱsuchȱasȱarming,ȱdisarming,ȱlisteningȱinȱandȱtalkingȱtoȱtheȱ
premisesȱandȱmore.ȱTheȱsystemȱcanȱalsoȱprovideȱaudibleȱinformationȱ
suchȱasȱeventȱoccurrencesȱandȱtheȱstatusȱofȱyourȱsystem.ȱ
ȱ
IfȱyourȱsystemȱisȱequippedȱwithȱaȱGSM/GPRSȱmoduleȱitȱcanȱprovideȱ
informationȱaboutȱtheȱsystemȱsuchȱasȱeventȱoccurrencesȱbyȱSMS.ȱYouȱ
canȱalsoȱoperateȱtheȱsystemȱusingȱSMSȱcommandsȱforȱarmingȱandȱ
disarmingȱtheȱsystemȱandȱmore.ȱ
SMS:ȱȱ
ConfigurationȱSoftware:ȱȱ
ȱ
RISCOȱGroupȇsȱConfigurationȱSoftwareȱenablesȱtheȱinstallerȱtoȱ
programȱtheȱsystemȱandȱoperateȱtheȱsystemȱlocallyȱorȱremotely.ȱ
WebȱBrowser:ȱȱ
ȱ
Usingȱtheȱwebȱyouȱcanȱperformȱaȱvarietyȱofȱoperationsȱonȱyourȱ
systemȱsuchȱasȱarming,ȱdisarming,ȱoutputȱactivation,ȱreceiveȱstatusȱ
informationȱandȱviewingȱeventȱlogs.ȱThisȱfeatureȱwillȱbeȱavailableȱinȱ
futureȱversionsȱofȱAgility.ȱ
Page 7
ȱ
AgilityȱUserȱManualȱ
1.4 Status Indications
LED Indicators
TheȱLEDȱindicatorsȱprovideȱtypicalȱsystemȱindications,ȱasȱdiscussedȱbelow.ȱSomeȱ
indicatorsȱhaveȱadditionalȱfunctions,ȱwhichȱareȱexplainedȱlaterȱon.ȱ
Power LED
(Green)
TheȱPowerȱLEDȱindicatesȱsystemȱoperation.ȱ
Condition
Description
Onȱ
Rapidȱflashȱ
Slowȱflashȱ
PowerȱOKȱ
IndicatesȱACȱtroubleȱ
Indicatesȱlowȱbatteryȱtroubleȱ
Arm/Alarm LED
(Red)
Condition
Description
Onȱ
Rapidȱflashȱ
Slowȱflashȱ
Systemȱarmedȱ
Alarmȱ
SystemȱinȱExitȱdelayȱ
Stay LED
(Red)
Condition
Description
Onȱ
Offȱ
SystemȱarmedȱatȱSTAYȱ
Systemȱdisarmedȱȱ
Ready LED
(Green)
Condition
Description
Onȱ
Offȱ
SlowȱFlashȱ
Systemȱreadyȱ
Openȱzonesȱȱ
Systemȱisȱreadyȱtoȱbeȱarmedȱwhileȱaȱspeciallyȱ
designatedȱentry/exitȱdoorȱremainsȱopenȱ
Trouble LED
(Orange)
Condition
Description
RapidȱFlashȱ
Offȱ
Troubleȱ
Noȱtroubleȱȱ
Note:ȱWhenȱallȱLEDsȱflashȱoneȱafterȱanotherȱinȱsequenceȱtheȱsystemȱisȱinȱInstallationȱmode.
Page 8
AgilityȱUserȱManualȱ
ȱ
Status Button / Service Call (Listen & Talk)
TheȱbuttonȱonȱtheȱmainȱunitȱcanȱbeȱdefinedȱasȱaȱsystemȱstatusȱindicatorȱorȱasȱaȱS.O.Sȱ
button.ȱOnceȱpressed,ȱaȱserviceȱcallȱwillȱbeȱestablishedȱtoȱtheȱmonitoringȱstation,ȱ
whichȱthenȱenablesȱ2Ȭwayȱcommunicationȱwithȱtheȱpremises.ȱȱȱ
Voice Messaging
ThreeȱtypesȱofȱspokenȱmessagesȱareȱheardȱwhenȱusingȱtheȱAgility,ȱlocallyȱinȱtheȱpremisesȱ
orȱremotelyȱtoȱyourȱmobile:ȱ
Eventȱmessages:ȱUponȱselectedȱeventȱoccurrence,ȱtheȱAgilityȱinitiatesȱaȱcallȱtoȱaȱ
remoteȱFollowȱMeȱ(FM)ȱtelephoneȱnumber,ȱinformingȱyouȱofȱaȱsecurityȱsituationȱbyȱ
playingȱaȱpreȬrecordedȱEventȱannouncementȱmessage.ȱ
Statusȱmessages:ȱUponȱremoteȱaccessȱofȱtheȱsystemȱbyȱinitiatingȱaȱcallȱfromȱaȱ
remoteȱtelephoneȱorȱreceivingȱaȱcallȱfromȱtheȱsystem,ȱtheȱAgilityȱannouncesȱtheȱ
currentȱsystemȱstatusȱbyȱplayingȱaȱpreȬrecordedȱStatusȱmessage.ȱȱ
LocalȱAnnouncementȱmessages:ȱUponȱeventȱoccurrenceȱorȱuser’sȱkeypadȱ
operations,ȱtheȱAgilityȱcanȱannounceȱvariousȱlocalȱmessagesȱtoȱresidents.ȱȱ
SMS Messaging
UsingȱtheȱGSM/GPRSȱModuleȱtheȱsystemȱcanȱsendȱpredefinedȱSMSȱeventȱmessagesȱtoȱaȱ
remoteȱFollowȱMeȱ(FM)ȱtelephoneȱnumber,ȱinformingȱyouȱofȱtheȱstatusȱofȱtheȱsecurityȱ
systemȱandȱcertainȱeventsȱthatȱoccurredȱinȱtheȱsystem.ȱ
Forȱexample:ȱȱ
ȱ
Email Messaging
UsingȱtheȱAgilityȱIPȱModuleȱtheȱsystemȱcanȱsendȱeventȱmessagesȱbyȱEmailȱtoȱpredefinedȱeȬ
mailȱaddressesȱinformingȱyouȱofȱtheȱstatusȱofȱtheȱsecurityȱsystemȱandȱcertainȱeventsȱthatȱ
occurredȱinȱtheȱsystem.ȱ
Forȱexample:ȱȱ
Subject:ȱȱAlarmȱSecurityȱMessage:ȱIntruderȱAlarmȱȱ
SystemȱName:ȱJohnȇsȱResidenceȱ
Event:ȱFireȱAlarm,ȱZoneȱ5,ȱEntranceȱdoorȱȱȱ
Time:ȱ01ȱAprilȱ2008;ȱ16:12ȱ
Partition:ȱPartitionȱ1,ȱFirstȱfloorȱȱȱȱȱȱ
ServiceȱContact:ȱMonitoringȱStationȱ01,ȱ03Ȭ5676778ȱ
ȱ
Page 9
ȱ
AgilityȱUserȱManualȱ
Sound Indications
InȱadditionȱtoȱtheȱvisualȱindicationsȱprovidedȱbyȱtheȱAgility’sȱLEDs,ȱyourȱsystemȱproducesȱ
audibleȱnotificationȱafterȱcertainȱevents.ȱ
Condition
Description
Intrusionȱalarmȱ
Fireȱalarmȱ
Exitȱdelayȱ
Entryȱdelayȱ
Confirmȱoperationȱ
Rejectȱoperationȱ
Arm/Disarmȱsquawkȱ
Continuesȱrapidȱbeepingȱ
Staggeredȱrapidȱbeepingȱ
SlowȱbuzzerȱbeepsȱuntilȱtheȱExitȱDelayȱtimeȱperiodȱexpiresȱ
SlowȱbuzzerȱbeepsȱuntilȱtheȱEntryȱDelayȱtimeȱperiodȱexpires.ȱȱ
AȱoneȬsecondȱtoneȱ
Threeȱrapidȱerrorȱbeepsȱ
1ȱsirenȱchirp:ȱSystemȱarmedȱ
2ȱsirenȱchirps:ȱSystemȱisȱdisarmedȱ
4ȱsirenȱchirps:ȱSystemȱdisarmedȱafterȱanȱalarmȱ
ȱ
ȱ
Page 10
AgilityȱUserȱManualȱ
ȱ
Chapter 2 - Local System Operation
2.1 Arming your system
Armingȱyourȱsystemȱcausesȱtheȱintrusionȱdetectorsȱtoȱtriggerȱanȱalarmȱwhenȱviolated.ȱTheȱ
armingȱoperationȱwillȱbeȱfollowedȱbyȱaȱlocalȱmessageȱannouncementȱ(ifȱdefined).ȱȱ
Beforeȱarmingȱtheȱsystemȱcheckȱtheȱ ȱReadyȱLEDȱandȱmakeȱsureȱthatȱtheȱsystemȱisȱreadyȱ
toȱbeȱarmed.ȱIfȱtheȱsystemȱisȱNOTȱreadyȱtoȱbeȱarmedȱsecureȱorȱbypassȱtheȱviolatedȱzone(s),ȱ
andȱthenȱproceed.ȱ
Failingȱtoȱarmȱtheȱsystemȱwillȱbeȱindicatedȱbyȱtheȱsystemȱ
YourȱAgilityȱoffersȱtheȱfollowingȱkindsȱofȱarming:ȱȱ
Note:ȱIfȱyouȱareȱunableȱtoȱarmȱtheȱsystem,ȱpressȱtheȱstatusȱkeyȱtoȱviewȱsystemȱmessages.ȱ
Awayȱ(Full)ȱarming:ȱȱ
Awayȱarmingȱpreparesȱallȱofȱtheȱsystemȇsȱintrusionȱdetectorsȱtoȱactivateȱanȱalarmȱifȱ
violated,ȱandȱisȱusedȱwhenȱleavingȱtheȱpremises.ȱTheȱsystemȱwillȱarmȱafterȱtheȱ
designatedȱcountdownȱtimeȱ(Exitȱdelay)ȱandȱaȱlocalȱmessageȱwillȱsound.ȱOnceȱyouȱhaveȱ
armedȱtheȱsystem,ȱexitȱviaȱtheȱdesignatedȱfinalȱexitȱdoor.ȱ
Toȱarmȱusing
Awayȱ(Full)ȱarming procedure
Quickȱmode:ȱ
ȱ
ȱ
Highȱsecurityȱmode:ȱPressȱ
Quickȱmode:ȱ
ȱ
ȱ+ȱcodeȱ
ȱȱ
Highȱsecurityȱmode:ȱ
ȱ+ȱcodeȱorȱproximityȱtagȱȱȱ
Press±ȱ
SendȱSMSȱ:ȱ[Code][A],ȱexample,ȱ1234Aȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Page 11
ȱ
AgilityȱUserȱManualȱ
Stayȱ(Home)ȱarming:ȱȱȱ
Stayȱarmingȱactivatesȱonlyȱperimeterȱdetectorsȱ(asȱdefinedȱbyȱyourȱinstaller),ȱenablingȱ
individualsȱtoȱremainȱinsideȱandȱmoveȱaboutȱtheȱpremisesȱwhileȱtheȱsystemȱisȱpartiallyȱ
armed.ȱ
Toȱarmȱusing
Stayȱ(Home)ȱarming procedure
ȱȱ
Quickȱmode:ȱ
Highȱsecurityȱmode:ȱ
ȱ
ȱȱ
Quickȱmode:ȱ
ȱ
ȱ+ȱcodeȱ
ȱ+ȱcodeȱorȱproximityȱtagȱȱȱ
Highȱsecurityȱmode:ȱ
Pressȱ±ȱbuttonȱorȱbuttonȱ4ȱ(ifȱdefined.ȱAdviseȱwithȱyourȱinstaller)ȱ
SendȱSMSȱ:ȱ[Code][H],ȱexample,ȱ1234Hȱ
ȱ
Partitionȱarming:ȱȱ
OneȱofȱtheȱAgilityȇsȱadvantagesȱisȱitsȱabilityȱtoȱdivideȱtheȱsystemȱinȱupȱtoȱ3ȱpartitions.ȱ
Eachȱpartitionȱmayȱbeȱmanagedȱasȱaȱseparateȱsecurityȱsystem,ȱeachȱofȱwhichȱcanȱbeȱ
armedȱandȱdisarmedȱindividuallyȱregardlessȱofȱtheȱconditionȱofȱtheȱother.ȱȱ
Partitionsȱcanȱbeȱarmedȱorȱdisarmedȱoneȱatȱaȱtime,ȱorȱallȱatȱonce,ȱandȱeachȱpartitionȱcanȱ
beȱarmedȱatȱStayȱorȱAway.ȱOnlyȱusersȱthatȱhaveȱbeenȱdefinedȱtoȱoperateȱmultipleȱ
partitionsȱcanȱoperateȱmoreȱthanȱoneȱpartitionȱandȱarm/disarmȱallȱpartitionsȱatȱonceȱ
Toȱarmȱusing
Partitionȱarmingȱ(AwayȱorȱStay) procedure
Quickȱmode:ȱ
/
/
Highȱsecurityȱmode:ȱ
ȱ
Quickȱmode:ȱ
ȱ
/
Highȱsecurityȱmode:ȱ
/
/
>
ȱ/ȱ
/
>
>
/
/
ȱ
ȱ/ȱ
ȱ/ȱ
ȱȱ
>
ȱ/ȱ
ȱ+ȱcodeȱ
ȱ+ȱcodeȱorȱproximityȱtagȱȱȱ
Pressȱ±ȱbuttonȱorȱbuttonȱ4ȱ(ifȱdefined.ȱAdviseȱwithȱyourȱinstaller)ȱ
ȱ
SendȱSMS:ȱȱ[Code][AȱorȱH]ȱ[Partitionȱ1,2ȱorȱ3].ȱExampleȱ1234A1.ȱForeȱmoreȱ
informationȱreferȱtoȱpageȱ21.ȱ
ȱ
Page 12
AgilityȱUserȱManualȱ
ȱ
ForceȱArming:ȱ
Forceȱarmingȱarmsȱtheȱsystemȱregardlessȱofȱopenȱzones.ȱYourȱinstallerȱmustȱenableȱthisȱ
option.ȱȱ
Note:ȱForceȱarmingȱtheȱsystemȱresultsȱinȱleavingȱpartȱofȱtheȱsystemȱunsecured.ȱ
ȱ
ArmingȱwithȱtroublesȱinȱtheȱSystemȱȱ
Ifȱrequired,ȱandȱdefinedȱbyȱyourȱinstaller,ȱallȱtroublesȱinȱtheȱsystemȱshouldȱbeȱconfirmedȱ
toȱenableȱtheȱarmingȱoperationȱwhileȱperformingȱarmingȱfromȱtheȱwirelessȱkeypad.ȱȱȱ
Whenȱtryingȱtoȱarmȱtheȱsystemȱwithȱtroubles,ȱtheȱdisplayȱwillȱshowȱaȱȈSystemȱTroublesȈȱ
ȱkeyȱtoȱviewȱtheȱtroublesȱinȱtheȱsystem.ȱScrollȱdownȱtheȱ
message.ȱPressȱtheȱȱ
troublesȱlistȱtoȱviewȱallȱtroublesȱinȱtheȱsystem.ȱ
Toȱenableȱoneȱtimeȱarmingȱfromȱtheȱkeypad:ȱȱȱ
ȱandȱenterȱyourȱuserȱcodeȱtoȱaccessȱtheȱuserȱmenu.ȱ
1.
Pressȱ
2.
GoȱtoȱActivitiesȱ>ȱBypassȱTroubleȱȱ
3.
Theȱfollowingȱquestionȱwillȱappear:ȱȈBypassȱtroubles.ȱAreȱyouȱsure?ȱN?Ȉ.ȱUsingȱtheȱ
ȱkeyȱchangeȱtoȱYȱandȱpressȱ
4.
Pressȱ
ȱtoȱconfirm.ȱ
ȱtoȱreturnȱtoȱmainȱdisplayȱandȱperformȱtheȱarmingȱoperationȱagain.ȱȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Page 13
ȱ
AgilityȱUserȱManualȱ
2.2 Disarming your system
Disarmingȱyourȱsystemȱcausesȱtheȱdetectorsȱnotȱtoȱtriggerȱanȱalarmȱwhenȱviolated.ȱWhenȱ
youȱenterȱtheȱpremises,ȱtheȱEntryȱDelayȱbeginsȱtoȱcountȱdown.ȱYouȱmustȱdisarmȱtheȱ
systemȱwithinȱtheȱEntryȱDelayȱtimeȱtoȱpreventȱtheȱsystemȱfromȱtriggeringȱanȱalarm.ȱTheȱ
disarmingȱoperationȱwillȱbeȱfollowedȱbyȱaȱlocalȱmessageȱannouncementȱ(ifȱdefined).ȱȱ
Note:ȱIfȱanȱalarmȱoccurredȱinȱtheȱsystem,ȱitȱisȱrecommendedȱtoȱleaveȱtheȱpremises.ȱOnlyȱafterȱpoliceȱ
investigationȱshouldȱyouȱconsiderȱthatȱtheȱburglarȱisȱnoȱlongerȱonȱyourȱpremisesȱandȱyouȱcanȱreȬenter.ȱInȱ
specialȱcasesȱ(ifȱprogrammedȱbyȱyourȱinstaller)ȱarmingȱtheȱsystemȱafterȱanȱalarmȱmightȱrequireȱaȱtechnicianȱ
code.ȱForȱmoreȱinformationȱreferȱtoȱyourȱinstallerȱ
YourȱAgilityȱoffersȱtheȱfollowingȱkindsȱofȱdisarming:ȱȱ
ȱ
Systemȱdisarming:ȱ
Disarmingȱdeactivatesȱtheȱpartitionsȱassignedȱtoȱtheȱspecifiedȱuserȱcodeȱ
Toȱdisarmȱusing
ProcedureȱforȱDisarming
Quickȱmode:ȱ
disarmedȱ
ȱ
.ȱAllȱpartitionsȱassignedȱtoȱtheȱbuttonȱwillȱbeȱ
Highȱsecurityȱmode:ȱȱ
Pressȱ
ȱ>ȱCodeȱ
ȱfollowedȱbyȱcodeȱorȱproximityȱtag.ȱ
ȱ
ȱ
Pressȱtheȱ²ȱbutton.ȱAllȱpartitionsȱassignedȱtoȱtheȱbuttonȱwillȱbeȱ
disarmed.ȱȱ
SendȱSMS:ȱȱ[Code][D],ȱexampleȱ1234Dȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Page 14
AgilityȱUserȱManualȱ
ȱ
Partitionȱdisarming:ȱ
Partitionȱdisarmingȱenablesȱyouȱtoȱdisarmȱindividualȱpartitionsȱwithinȱanȱarmedȱsystemȱ
Toȱdisarmȱusing
ProcedureȱforȱPartitionȱDisarming
Quickȱmode:ȱ
/
/
Highȱsecurityȱmode:ȱȱ
ȱ
/
/
>
ȱȱȱ
>
/
/
>
ȱ>ȱCodeȱ
>ȱcodeȱorȱproximityȱtag.ȱ
ȱ
ȱ
ȱ
Pressȱtheȱ²ȱbutton.ȱAllȱpartitionsȱassignedȱtoȱtheȱbuttonȱwillȱbeȱ
disarmed.ȱȱ
SendȱSMS:ȱȱ[Code][D]ȱ[Partitionȱ1,2ȱorȱ3].ȱExampleȱ1234D1.ȱForeȱmoreȱ
informationȱreferȱtoȱpageȱ21.ȱ
ȱ
Duressȱdisarming:ȱ
Ifȱyouȱareȱeverȱcoercedȱintoȱdisarmingȱyourȱsystem,ȱyouȱcanȱcomplyȱwithȱtheȱintruderȇsȱ
wishesȱwhileȱsendingȱaȱsilentȱduressȱalarmȱtoȱtheȱCentralȱStation.ȱToȱdoȱso,ȱyouȱmustȱ
useȱaȱspecialȱduressȱcode,ȱwhichȱwhenȱused,ȱwillȱdisarmȱtheȱsystemȱinȱtheȱregularȱ
manner,ȱwhileȱsimultaneouslyȱtransmittingȱtheȱduressȱalarm.ȱConferȱwithȱyourȱinstallerȱ
whichȱofȱtheȱuserȇsȱcodesȱisȱdefinedȱasȱaȱduressȱcode.ȱȱ
Note:ȱUnderȱnoȱcircumstancesȱmustȱtheȱduressȱcodeȱbeȱusedȱhaphazardlyȱorȱwithoutȱreason.ȱCentralȱ
Stations,ȱalongȱwithȱPoliceȱDepartments,ȱtreatȱduressȱcodesȱveryȱseriouslyȱandȱtakeȱimmediateȱaction.ȱȱ
ȱ
DisarmingȱafterȱanȱAlarm:ȱ
Whenȱsilencingȱanȱalarmȱtheȱsystemȱgoesȱintoȱaȱdisarmȱstate.ȱAfterȱtheȱsystemȱisȱ
disarmedȱtheȱsirensȱwillȱsoundȱ4ȱsirenȱchirpsȱindicatedȱthatȱanȱalarmȱoccurredȱinȱtheȱ
system.ȱOnȱtheȱkeypad,ȱpressȱ
lastȱalarm.ȱȱ
forȱ2ȱsecondsȱinȱorderȱtoȱviewȱinformationȱaboutȱtheȱ
IfȱanȱȈEntryȱdoorȈȱisȱopenedȱpriorȱtoȱdisarmingȱtheȱsystem,ȱtheȱfollowingȱvoiceȱ
announcementȱmessageȱwillȱbeȱheard:ȱȈAlarmȱoccurredȱinȱtheȱsystemȈ.ȱPressȱtheȱ
keyȱwillȱindicateȱtheȱcauseȱofȱtheȱalarm.ȱ
Page 15
ȱ
ȱ
AgilityȱUserȱManualȱ
Note:ȱIfȱanȱalarmȱoccurredȱinȱtheȱsystem,ȱitȱisȱrecommendedȱtoȱleaveȱtheȱpremises.ȱOnlyȱafterȱpoliceȱ
investigationȱshouldȱyouȱconsiderȱthatȱtheȱburglarȱisȱnoȱlongerȱonȱyourȱpremisesȱandȱyouȱcanȱreȬenter.ȱ
Inȱspecialȱcasesȱ(ifȱprogrammedȱbyȱyourȱinstaller)ȱarmingȱtheȱsystemȱafterȱanȱalarmȱmightȱrequireȱaȱ
technicianȱcode.ȱForȱmoreȱinformationȱreferȱtoȱyourȱinstaller.ȱ
Yourȱinstallerȱcanȱdefineȱtheȱnumberȱofȱtimesȱ(0Ȭ15)ȱthatȱanȱalarmȱwillȱbeȱsentȱfromȱtheȱsameȱdetectorȱ
duringȱoneȱarmingȱperiod.ȱThisȱisȱusuallyȱusedȱtoȱpreventȱanȱalarmȱfromȱaȱmalfunctionȱdetector,ȱanȱ
environmentalȱproblemȱorȱincorrectȱinstallationȱ
ȱ
Resettingȱafterȱanȱalarm:ȱ
YourȱinstallationȱcompanyȱcanȱdefineȱthatȱtheȱresetȱofȱtheȱsystemȱtoȱaȱNormalȱOperationȱ
modeȱwillȱrequireȱtheȱinterventionȱofȱyourȱmonitoringȱstationȱorȱinstaller.ȱInȱthisȱcase,ȱ
afterȱanȱalarmȱconditionȱtheȱsystemȱwillȱbeȱregardedȱasȱNotȱReadyȱandȱwhileȱrequestingȱ
forȱsystemȱstatusȱ(
)indicationȱyouȱwillȱgetȱaȱtroubleȱmessage:ȱTechnicianȱReset.ȱȱ
AntiȱCodeȱResetȱȱ
1.
Pressȱ
.ȱȱ
Enterȱuserȱcodeȱ
GoȱtoȱActivitiesȱ>ȱAntiȱCodeȱoption.ȱ
2.
Callȱyourȱmonitoringȱstationȱ(MS)ȱorȱinstallerȱandȱquoteȱtheȱ“RANDOMȱ
CODE”ȱdisplayedȱonȱyourȱkeypad.ȱTheȱMSȱorȱinstallerȱwillȱgiveȱyouȱaȱreturnȱ
AntiȬCode.ȱ
3.
EnterȱthisȱAntiȱcodeȱfollowedȱbyȱ
andȱtheȱsystemȱwillȱreset.ȱȱ
InstallerȱResetȱ
Yourȱmonitoringȱstationȱ(MS)ȱorȱinstallerȱcanȱresetȱyourȱsystemȱremotelyȱorȱlocallyȱ
fromȱtheȱkeypad.ȱȱ
Toȱenableȱlocalȱresetȱbyȱyourȱinstallerȱyouȱmayȱneedȱtoȱauthorizeȱhimȱusingȱtheȱmasterȱ
codeȱafterȱtheȱinstallerȱentersȱhisȱcode.ȱAȱoneȱhourȱtimeȱwindowȱisȱopenedȱforȱtheȱ
installerȱtoȱprogramȱuserȱfunctionsȱandȱbeȱableȱtoȱresetȱyourȱsystemȱlocallyȱȱ
Page 16
AgilityȱUserȱManualȱ
ȱ
2.3 Sending a Panic Alarm
Panicȱalarmsȱenableȱyouȱtoȱsendȱaȱmessageȱtoȱtheȱmonitoringȱstationȱinȱtheȱeventȱofȱanȱ
emergency,ȱsendȱaȱmessageȱtoȱaȱfollowȱmeȱnumber,ȱannounceȱaȱlocalȱmessageȱorȱactivateȱaȱ
localȱalarm.ȱPanicȱalarmsȱcanȱbeȱsetȱtoȱbeȱsilentȱ(Referȱtoȱyourȱinstallerȱforȱmoreȱ
information).ȱȱ
ToȱsendȱaȱPanicȱ
Alarmȱusing
Procedure
Pressȱbothȱ
ȱand
Pressȱbothȱ
ȱandȱ
ȱkeysȱsimultaneouslyȱ
keysȱsimultaneouslyȱ
Note:ȱYourȱinstallerȱshouldȱdefineȱtheseȱkeysȱtoȱbeȱsetȱasȱpanicȱkeys.ȱTheseȱkeysȱ
canȱbeȱeitherȱdisabledȱorȱusedȱtoȱestablishȱaȱserviceȱcallȱtoȱyourȱ
MonitoringȱStation.ȱȱ
ȱ
Ifȱdefinedȱbyȱyourȱinstallerȱpressingȱ
simultaneouslyȱforȱ2ȱ
secondsȱwillȱsendȱaȱfireȱalarmȱandȱpressingȱ
ȱsimultaneouslyȱ
forȱ2ȱsecondsȱwillȱsendȱaȱspecialȱemergencyȱorȱmedicalȱalarm.ȱȱ
Pressȱtheȱsmallȱblankȱbuttonȱ(ifȱdefined)ȱ
ȱ
Note:ȱYourȱinstallerȱcanȱdefineȱtheȱsmallȱblankȱbuttonȱtoȱbeȱusedȱforȱsendingȱaȱ
panicȱalarm.ȱȱ
Note:ȱForȱfullȱcapabilitiesȱofȱtheȱ2Ȭwayȱremoteȱcontrol,ȱtheȱbiȬdirectionalȱkeypadȱandȱ4ȱbuttonȱkeyȱfob,ȱ
referȱtoȱtheȱinstructionsȱsuppliedȱwithȱeachȱproduct.ȱȱ
Pressȱbothȱȱkeysȱsimultaneouslyȱ
Pressȱtheȱpanicȱbuttonȱ
Page 17
ȱ
AgilityȱUserȱManualȱ
Chapter 3 - Remote System Operation
3.1 Remote Phone Operation
TheȱAgilityȱenablesȱyouȱtoȱoperateȱtheȱsystemȱfromȱaȱremoteȱtouchȬtoneȱphoneȱbyȱ
initiatingȱaȱtelephoneȱcallȱtoȱorȱfromȱtheȱsystemȱandȱinteractingȱwithȱvoiceȱmenusȱthatȱ
guideȱyouȱthroughȱyourȱrequiredȱremoteȱoperation.ȱȱ
Remotely Accessing the System
Remotelyȱaccessingȱtheȱsystemȱinvolvesȱinitiatingȱaȱcallȱtoȱtheȱsystem,ȱandȱenteringȱyourȱ
remoteȱaccessȱcodeȱandȱtheȱuserȱcodeȱyouȱusuallyȱenterȱinȱtheȱsystemȱkeypad.ȱ
Toȱremotelyȱaccessȱtheȱsystem:ȱ
1.
FromȱaȱremoteȱtouchȬtoneȱtelephone,ȱdialȱtheȱnumberȱofȱtheȱpremisesȱwhereȱ
Agilityȱisȱinstalled.ȱȱ
2.
Ifȱyourȱsystemȱisȱconnectedȱtoȱaȱlandȱtelephoneȱlineȱandȱanȱansweringȱ
machineȱisȱinȱuseȱatȱtheȱpremisesȱletȱtheȱlineȱringȱonce,ȱthenȱhangȱupȱandȱcallȱ
again.ȱ
Ifȱanȱansweringȱmachineȱisȱnotȱinȱuseȱatȱtheȱpremisesȱwaitȱuntilȱtheȱsystemȱ
picksȱup.ȱAfterȱtheȱsystemȱpicksȱupȱaȱshortȱtoneȱisȱheard.ȱ
Note:ȱWhenȱtheȱsystemȱpicksȱup,ȱallȱphonesȱonȱtheȱsameȱlineȱareȱeffectivelyȱdisconnectedȱandȱ
cannotȱbeȱused.ȱ
3.
Enterȱyourȱ2ȱdigitȱremoteȱaccessȱcodeȱwithinȱ10ȱsecondsȱ(Defaultȱcodeȱ=ȱ00).ȱȱ
Theȱfollowingȱmessageȱisȱannounced:ȱȈHello,ȱPleaseȱEnterȱYourȱUserȱCode,ȱ
FollowedȱByȱ[#]Ȉ.ȱȱ
Enterȱyourȱuserȱcodeȱfollowedȱbyȱ[#].ȱ(Defaultȱcode=1234)ȱ
4.
Afterȱyourȱcodeȱisȱacceptedȱaȱsystemȱstatusȱmessageȱisȱannounced,ȱfollowedȱbyȱ
theȱOperationsȱmenu.ȱYouȱcanȱnowȱperformȱtheȱrequiredȱremoteȱoperations.ȱ
Voice Operations Menu
TheȱVoiceȱOperationsȱmenuȱannouncesȱoptionsȱandȱinstructionsȱonȱhowȱtoȱuseȱtheȱsystemȱ
functions.ȱTheȱoptionsȱinȱtheȱOperationsȱmenuȱvaryȱaccordingȱtoȱsystemȱstatusȱandȱyourȱ
accessȱrights.ȱȱ
Followingȱisȱaȱlistȱofȱtheȱremoteȱoperationsȱoptions:ȱ
Operation
Quick Key Combination
Armingȱallȱpartitionsȱ
Pressȱ[1][1]ȱ
Armingȱaȱselectedȱpartitionȱ
Pressȱ[1][9]ȱfollowedȱbyȱtheȱpartitionȱnumberȱ
Disarmingȱallȱpartitionsȱ
Pressȱ[2][2]ȱ
Disarmingȱaȱselectedȱpartitionȱ
Pressȱ[2][9]ȱfollowedȱbyȱtheȱpartitionȱnumberȱ
Page 18
AgilityȱUserȱManualȱ
ȱ
Operation
Quick Key Combination
ChangingȱZoneȱBypassȱstatusȱ
Pressȱ[3]ȱfollowedȱbyȱtheȱzoneȱnumberȱandȱthenȱ[#][9]ȱ
OperatingȱUtilityȱOutputsȱ
Pressȱ[4]ȱfollowedȱbyȱtheȱoutputȱnumberȱ
ChangingȱFollowȱMe(FM)ȱ
numbersȱ
Pressȱ[5]ȱfollowedȱbyȱtheȱFMȱnumberȱandȱ[#][2].ȱ
Enterȱtheȱnewȱphoneȱnumberȱandȱpressȱ[#][1].ȱ
Listenȱinȱtoȱtheȱpremisesȱ
Pressȱ[6][1]ȱ
Talkingȱtoȱtheȱpremisesȱ
Pressȱ[6][2]ȱ
ListenȱandȱTalkȱtoȱtheȱpremisesȱ
Pressȱ[6][3]ȱ
Recordingȱmessagesȱthatȱareȱnotȱ
includedȱinȱtheȱmessageȱbankȱ(5ȱ
messages)ȱ
Pressȱ[7][1]…ȱ[5]ȱ
Recordingȱanȱopeningȱmessageȱ
Pressȱ[7][6]ȱ
ExitingȱtheȱSystemȱ
Pressȱ[0]ȱ
Toȱreturnȱtoȱtheȱpreviousȱmenuȱ
Pressȱ[*]ȱ
Toȱrepeatȱtheȱmenuȱoptionsȱ
Pressȱ[#]ȱ
Receiving Calls from the System
Uponȱeventȱoccurrence,ȱsuchȱasȱalarmȱactivation,ȱtheȱsystemȱinformsȱyouȱofȱsecurityȱ
situations,ȱforȱexample,ȱintrusionȱorȱfire,ȱbyȱcallingȱyouȱandȱannouncingȱaȱpreȬrecordedȱ
eventȱannouncementȱmessage,ȱfollowedȱbyȱtheȱAcknowledgeȱmenu.ȱTheȱsystemȱcanȱcallȱ
upȱtoȱ16ȱFollowȱMeȱnumbers,ȱenablingȱyou,ȱaȱrelativeȱorȱneighborȱtoȱbeȱinformedȱofȱtheȱ
securityȱsituation.ȱYouȱcanȱthenȱtakeȱtheȱappropriateȱaction,ȱwhetherȱthisȱisȱtoȱinformȱtheȱ
authoritiesȱorȱacknowledgeȱtheȱeventȱandȱremotelyȱoperateȱtheȱsystem.ȱ
Notes:ȱFollowȱMeȱmessagesȱareȱperformedȱonlyȱafterȱreportingȱtoȱtheȱMonitoringȱStation.ȱȱ
FollowȱMeȱnumbersȱareȱassignedȱcertainȱeventsȱforȱwhichȱtheyȱreceiveȱcalls.ȱȱ
TheȱsystemȱmustȱbeȱprogrammedȱtoȱcallȱaȱFMȱnumberȱafterȱaȱspecificȱeventȱoccursȱinȱorderȱforȱthatȱ
eventȱtoȱtriggerȱtheȱcall.ȱ
Toȱreceiveȱanȱeventȱcall:ȱ
1.
2.
Pickȱupȱtheȱphone.ȱ
SayȱȈHelloȈȱorȱpressȱ[#].ȱTheȱEventȱAnnouncementȱmessageȱisȱmade,ȱinformingȱ
youȱofȱaȱsecurityȱsituationȱinȱyourȱsystem,ȱforȱexample:ȱȱ
“24ȱOaklandsȱStreet,ȱIntruderȱalarm,ȱGroundȱFloor,ȱkitchen”ȱȱ
Notes:ȱIfȱnoȱvoiceȱisȱdetected,ȱtheȱeventȱmessageȱwillȱstartȱplayingȱ5ȱsecondsȱafterȱphoneȱpickȱup.ȱPressȱ[#]ȱtoȱ
beginȱplaybackȱofȱtheȱeventȱmessageȱfromȱtheȱbeginning.ȱ
ToȱrepeatȱtheȱEventȱAnnouncementȱmessageȱpressȱ[#].ȱ
ToȱbypassȱtheȱEventȱAnnouncementȱmessageȱandȱgoȱdirectlyȱtoȱtheȱAcknowledgeȱmenu,ȱpressȱ[*].ȱ
3.
Acknowledgeȱtheȱevent.ȱ(SeeȱAcknowledgeȱMenu)ȱ
Page 19
ȱ
AgilityȱUserȱManualȱ
Acknowledge Menu
AfterȱtheȱEventȱAnnouncementȱmessageȱisȱmade,ȱtheȱfollowingȱlistȱofȱoptionsȱisȱ
announced:ȱ
Operation
Digit
AcknowledgeȱMessageȱ
Acknowledgingȱanȱeventȱmeansȱthatȱyouȱhaveȱreceivedȱaȱmessageȱfromȱ
theȱsecurityȱalarmȱsystemȱaboutȱaȱrelevantȱeventȱinȱtheȱsystemȱandȱ
wantȱtoȱconfirmȱthis.ȱAfterȱyouȱacknowledgeȱanȱevent,ȱtheȱsystemȱcallsȱ
theȱnextȱFMȱnumber.ȱȱ
Pressȱ[1]ȱ
Acknowledgeȱandȱstopȱallȱdialingȱ
Thisȱoptionȱacknowledgesȱtheȱeventȱandȱstopsȱtheȱsystemȱfromȱcallingȱ
theȱnextȱFMȱnumbersȱtoȱreportȱtheȱevent.ȱ
Pressȱ[2]ȱ
followedȱbyȱ
theȱcodeȱ
AcknowledgeȱandȱaccessȱtheȱOperationsȱmenuȱ
TheȱOperationsȱmenuȱlistsȱtheȱavailableȱoptionsȱforȱremotelyȱoperatingȱ
yourȱsystem.ȱ
Pressȱ[3]ȱ
followedȱbyȱ
theȱcodeȱ
ListenȱInȱandȱTalkȱ
ThisȱoptionȱenablesȱyouȱtoȱperformȱbiȬdirectionalȱcommunication.ȱ
Pressȱ[6]ȱ
followedȱbyȱ
theȱcodeȱ
Repeatȱtheȱeventȱmessageȱ
Pressȱ[#]ȱ
RepeatȱtheȱAcknowledgeȱmenuȱ
Pressȱ[*]ȱ
Note:ȱIfȱanȱinvalidȱcodeȱisȱenteredȱ3ȱconsecutiveȱtimes,ȱtheȱsystemȱhangsȱupȱandȱthisȱFMȱnumberȱisȱlockedȱ
forȱ15ȱminutesȱandȱnoȱcallsȱareȱinitiatedȱtoȱtheȱFMȱnumber.ȱȱ
Ifȱaȱvalidȱuserȱcodeȱisȱnotȱenteredȱwithinȱ10ȱseconds,ȱtheȱsystemȱhangsȱup.ȱ
Bi-directional Communication
TheȱListenȱInȱandȱTalkȱoptionsȱenableȱyouȱtoȱremotelyȱandȱsilentlyȱlistenȱinȱtoȱyourȱ
premisesȱinȱorderȱtoȱverifyȱtheȱcauseȱofȱanȱeventȱoccurrence,ȱthroughȱtheȱmicrophoneȱorȱ
remotelyȱtalkȱtoȱyourȱpremisesȱviaȱtheȱAgilityȱloudspeaker,ȱforȱexample,ȱtoȱguideȱsomeoneȱ
inȱdistress.ȱȱ
Toȱlistenȱinȱorȱtalk:ȱ
1.
FromȱtheȱOperations/Acknowledgeȱmenu,ȱpressȱ[6].ȱTheȱfollowingȱmessagesȱareȱ
announced:ȱȱ
“ToȱListenȱInȱpressȱ1,ȱToȱTalkȱpressȱ[2],ȱToȱListenȱandȱTalkȱ(Openȱchannel)ȱpressȱ
[3],ȱToȱreturnȱtoȱtheȱpreviousȱmenu,ȱPressȱ[¾].”ȱ
2.
Selectȱtheȱdesiredȱoption.ȱȱȱȱ
3.
Pressȱ[¾]ȱtoȱendȱlisteningȱinȱandȱtalkingȱcommunicationȱandȱreturnȱtoȱtheȱ
Operationsȱmenu.ȱ
ȱ
Page 20
AgilityȱUserȱManualȱ
ȱ
Bi-directional Audio Options after an Alarm
InȱtheȱeventȱofȱBurglary,ȱFireȱandȱMedicalȱalarms,ȱtheȱAgilityȱisȱableȱtoȱreportȱtheseȱeventsȱ
andȱthenȱstayȱonȱtheȱline.ȱThisȱallowsȱtheȱmonitoringȱserviceȱtoȱperformȱVoiceȱAlarmȱ
verification,ȱverifyȱtheȱalarmȱorȱVerificationȱinȱorderȱtoȱverifyȱaȱcauseȱofȱeventȱorȱguideȱ
someoneȱinȱdistress.ȱ
Service call
ȱTheȱServiceȱCallȱfeatureȱenablesȱyouȱtoȱcallȱtheȱMonitoringȱStationȱbyȱpressingȱaȱkey.ȱToȱ
establishȱtheȱserviceȱcall,ȱpressȱtheȱbuttonȱonȱtheȱmainȱunitȱorȱpressȱsimultaneouslyȱtheȱ
buttonsȱ
ȱ
ȱonȱtheȱbiȬdirectionalȱkeypad.ȱ
Note:ȱTheȱServiceȱcallȱshouldȱbeȱdefinedȱbyȱyourȱinstaller.ȱ
3.2 SMS Operation
SMS Remote Control
TheȱAgilityȱenablesȱyouȱtoȱperformȱremoteȱcontrolȱoperationsȱusingȱsimpleȱSMSȱ
commands.ȱTheȱfollowingȱsectionȱdescribesȱtheȱSMSȱcommandsȱandȱtheȱresponseȱofȱtheȱ
systemȱtoȱtheseȱcommands.ȱ
Note:ȱThisȱapplicationȱisȱavailableȱonlyȱifȱaȱGSM/GPRSȱmoduleȱisȱinstalledȱinȱyourȱsystem.ȱ
Operation
Armȱallȱpartitionsȱofȱaȱ
userȱcodeȱ
Armȱallȱpartitionsȱtoȱ
Stay/HomeȱArmingȱ
Disarmȱallȱpartitionsȱ
ofȱaȱuserȱcodeȱ
Armȱbyȱpartitionȱ
Stay/Homeȱarmȱbyȱ
partitionȱ
DisarmȱbyȱPartitionȱȱ
Bypassȱaȱzoneȱ
UnȬbypassȱaȱzoneȱ
ActivateȱOutputȱ
DeactivateȱOutputȱȱ
ChangeȱFMȱnumberȱȱ
ȱ
Getȱsystemȱstatusȱ
Getȱlastȱalarmȱ
memoryȱ
GetȱSIMȱcreditȱlevelȱ
(forȱprepaidȱcards)ȱ
SMS Message Structure
[Code]ȱAȱȱ
Example
1234Aȱ
[Code]ȱHȱ
1234Hȱ
[Code]ȱDȱȱ
1234Dȱ
[Code]ȱAȱ[PartitionȱNo.]ȱ
[Code]ȱHȱ[PartitionȱNo.]ȱ
1234A1ȱ
1234H1ȱ
[Code]ȱDȱ[PartitionȱNo.]ȱ
[Code]ȱBȱ[zoneȱnumber]ȱ
[Code]ȱUBȱ[zoneȱNo.]ȱ
[Code]ȱUOONȱ[UOȱNo.]ȱ
[Code]ȱUOOFFȱ[UOȱNo.]ȱ
[Code]ȱFMPHONEȱ[FMȱserialȱnumber]ȱȱ
NEWȱ[NewȱPhoneȱNo.)ȱ
[Code]ȱSTȱ
[Code]ȱALȱ
1234D1ȱ
1234B05ȱ
1234UB05ȱ
1234UOON1ȱ
1234UOOFF1ȱ
1234FMPHONEȱ3ȱ
NEW0529692345ȱ
1234STȱ
1234ALȱ
[Code]ȱCRȱ
1234CRȱ
Page 21
ȱ
AgilityȱUserȱManualȱ
Notes:ȱSMSȱcommandsȱcanȱbeȱsentȱfromȱanyȱmobileȱphoneȱorȱfromȱanȱSMSȱwebsite.ȱ
Commandȱwordsȱareȱnotȱcaseȱsensitive.ȱ
Aȱseparatorȱbetweenȱcommandȱwordsȱisȱnotȱrequiredȱalthoughȱitȱisȱaccepted.ȱ
SMS Confirmation Message
AȱconfirmationȱmessageȱfollowingȱaȱSMSȱoperationȱisȱsentȱtoȱtheȱuser,ȱuponȱrequest,ȱbyȱ
addingȱtheȱlettersȱ“RP”ȱatȱtheȱendȱofȱtheȱSMSȱmessagesȱlistedȱbelow.ȱ
Example:ȱ
1234ȱAȱRPȱȬȱAȱconfirmationȱmessageȱfollowingȱanȱarmingȱoperationȱwillȱbeȱsentȱtoȱtheȱ
user.ȱȱ
ConfirmationȱorȱFailȱoperationȱmessagesȱcanȱbeȱassignedȱtoȱtheȱactionsȱofȱarming,ȱ
disarming,ȱbypassing,ȱactivatingȱoutputsȱorȱchangingȱfollowȱmeȱdefinitions.ȱȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
Page 22
AgilityȱUserȱManualȱ
ȱ
Chapter 4 - User Functions and Settings
Theȱfunctionsȱandȱsettingsȱexplainedȱinȱthisȱchapterȱcanȱonlyȱbeȱperformedȱviaȱyourȱ
keypadȱandȱtheȱConfigurationȱSoftware.ȱThisȱchapterȱrefersȱtoȱtheseȱfunctionsȱandȱsettingsȱ
asȱperformedȱviaȱtheȱkeypad.ȱReferȱtoȱtheȱConfigurationȱSoftwareȱmanualȱforȱmoreȱ
informationȱregardingȱhowȱtheseȱfunctionsȱandȱsettingsȱareȱperformedȱviaȱtheȱ
ConfigurationȱSoftware.ȱ
Whenȱusingȱtheȱkeypadȱduringȱtheȱprogrammingȱmodeȱuseȱtheȱfollowingȱtableȱtoȱbeȱ
familiarȱwithȱtheȱfunctionalityȱofȱtheȱkeys:ȱ
Function
Sequence
Exitsȱfromȱtheȱcurrentȱmenuȱȱ
ȱ
Terminatesȱcommandsȱandȱconfirmsȱdataȱtoȱbeȱstoredȱ
ȱ
Usedȱtoȱbrowseȱthroughȱtheȱmenu:ȱScrollsȱupȱaȱlistȱorȱmovesȱtheȱcursorȱ
ȱ
Changesȱdataȱ
ȱ
Numericalȱkeysȱareȱusedȱtoȱinputȱtheȱnumericȱcodesȱthatȱmayȱbeȱrequiredȱ
forȱarming,ȱdisarming,ȱorȱusedȱtoȱactivateȱspecificȱfunctionsȱ
ȱ
ȱ
4.1 User Codes
ToȱperformȱmanyȱofȱtheȱAgilityȱfunctions,ȱaȱsecurityȱcodeȱ(oftenȱcalledȱaȱuserȱcode)ȱmustȱ
beȱused.ȱEachȱindividualȱusingȱtheȱsystemȱisȱassignedȱaȱuserȱcode,ȱwhich,ȱinȱturn,ȱisȱlinkedȱ
toȱanȱAuthorityȱLevel.ȱThoseȱwithȱaȱȈhigherȱauthorityȈȱhaveȱaccessȱtoȱaȱgreaterȱnumberȱofȱ
systemȱfunctions,ȱwhileȱthoseȱwithȱaȱȈlowerȱauthorityȈȱareȱmoreȱrestrictedȱinȱwhatȱtheyȱ
mayȱdo.ȱThereȱareȱfourȱdifferentȱauthorityȱlevelsȱavailableȱforȱusersȱofȱtheȱAgility.ȱ
Notes:ȱToȱdefineȱtheȱauthorityȱlevelsȱreferȱtoȱyourȱinstaller.ȱȱ
Agilityȱcanȱsupportȱupȱtoȱ32ȱdifferentȱuserȱcodes.ȱUserȱcodesȱmayȱhaveȱvariableȱlengthsȱupȱtoȱ6ȱdigits.ȱ
YourȱAgilityȱwasȱgivenȱaȱGrandȱMasterȱCodeȱofȱ1Ȭ2Ȭ3Ȭ4ȱduringȱmanufacturing.ȱUnlessȱyourȱalarmȱ
companyȱhasȱalreadyȱchangedȱitȱtoȱsuitȱyourȱpreference,ȱitȇsȱbestȱtoȱmodifyȱthisȱcodeȱtoȱoneȱthatȱisȱ
uniqueȱandȱpersonalizedȱasȱhereinȱdescribed.ȱ
Page 23
ȱ
AgilityȱUserȱManualȱ
Setting / Changing User Codes
TheȱuserȱassignedȱtheȱGrandȱMasterȱauthorityȱlevelȱcanȱchangeȱallȱuserȱcodesȱbutȱcannotȱ
viewȱtheȱdigitsȱinȱtheȱuserȱcodeȱfields.ȱUsersȱwithȱotherȱauthorityȱlevelsȱcanȱonlyȱchangeȱ
theirȱownȱcodes.ȱTheȱsystemȱmustȱbeȱdisarmedȱinȱorderȱtoȱsetȱorȱchangeȱuserȱcodes.ȱ
Toȱset/changeȱaȱuserȱcode:ȱ
andȱȱ
1.
Pressȱ
2.
Enterȱyourȱcodeȱ
3.
Usingȱtheȱarrowȱkeys,ȱscrollȱtoȱtheȱoptionȱCodes/Tagsȱandȱpressȱ
.ȱ
Note:ȱIfȱyouȱenterȱaȱwrongȱuserȱcode,ȱtheȱkeypadȱproducesȱ3ȱshortȱbeepsȱandȱtheȱȈWrongȱCode.ȱPleaseȱTryȱ
AgainȈȱmessageȱwillȱbeȱheard.ȱPressȱ
ȱquicklyȱandȱreȬenterȱtheȱaboveȱsequenceȱcorrectly.ȱ
4.
ScrollȱtoȱUserȱCodesȱandȱpress
5.
YouȱwillȱseeȱtheȱoptionȱNew/Change.ȱPress
6.
UsingȱtheȱarrowsȱscrollȱtoȱselectȱtheȱUserȱIndexȱnumberȱtoȱwhichȱyouȱwantȱtoȱ
assignȱaȱuserȱcodeȱandȱpressȱ
.ȱ
ȱȱ
.ȱȱ
Note:ȱInȱtheȱAgilityȱsystem,ȱtheȱUserȱIndexȱnumberȱisȱfromȱ00ȱtoȱ32,ȱwhereȱ00ȱbelongsȱtoȱtheȱGrandȱMaster.ȱ
7.
EnterȱtheȱnewȱcodeȱandȱthenȱreȬenterȱtheȱcode.ȱIfȱsuccessful,ȱaȱsingleȱ
confirmationȱbeepȱisȱsounded,ȱifȱnot,ȱ3ȱquickȱerrorȱbeepsȱareȱsoundedȱ
8.
Repeatȱtheȱaboveȱstepsȱforȱadditionalȱcodesȱuntilȱyouȱhaveȱcompletedȱyourȱlistȱ
Deleting User Codes
Atȱtimes,ȱyouȱmayȱwantȱtoȱcompletelyȱdeleteȱaȱuserȱcode.ȱNoteȱthatȱitȱisȱimpossibleȱtoȱ
deleteȱtheȱMasterȱCodeȱ(althoughȱitȱcanȱbeȱchanged).ȱ
Theȱsystemȱmustȱbeȱdisarmedȱinȱorderȱtoȱdeleteȱuserȱcodes.ȱ
Toȱset/changeȱaȱuserȱcode:ȱ
1.
Followȱstepsȱ1Ȭ4ȱofȱtheȱpreviousȱprocedureȱ(SeeȱSetting/ChangingȱUserȱCodes)ȱ
2.
3.
ȱ
ScrollȱtheȱmenuȱtoȱtheȱoptionȱȈDeleteȱByȱUserȈ.ȱPress
UsingȱtheȱarrowsȱscrollȱtoȱselectȱtheȱUserȱIndexȱnumberȱwhichȱyouȱwantȱtoȱ
deleteȱandȱpress
.ȱ
ȱkeyȱtoȱselectȱ
4.
Theȱdisplayȱwillȱshow:ȱȈDeleteȱUser.ȱAreȱyouȱsure?Ȉ.ȱȱUseȱtheȱ
5.
[Y]ȱandȱpressȱ
.ȱIfȱsuccessful,ȱaȱsingleȱconfirmationȱbeepȱisȱsounded,ȱifȱnot,ȱ3ȱ
quickȱerrorȱbeepsȱareȱsoundedȱ
Repeatȱtheȱaboveȱstepsȱforȱdeletingȱadditionalȱcodesȱ
Page 24
AgilityȱUserȱManualȱ
ȱ
4.2 Proximity Tags
TheȱbiȬdirectionalȱkeypadȱenablesȱyouȱtoȱreplaceȱtheȱuseȱofȱaȱcodeȱwithȱaȱproximityȱtagȱtoȱ
armȱandȱdisarmȱtheȱsecurityȱsystemȱorȱtoȱactivateȱandȱdeactivateȱhomeȱappliancesȱandȱ
utilities,ȱsuchȱasȱheatingȱandȱlights.ȱȱProximityȱtagȱprogrammingȱisȱperformedȱfromȱtheȱ
UserȱFunctionsȱmenu.ȱWhenȱprogrammingȱaȱproximityȱtag,ȱtheȱfollowingȱthreeȱoptionsȱareȱ
available:ȱ
Addingȱaȱnewȱtagȱ
Deletingȱaȱtagȱbyȱtheȱuserȱserialȱnumberȱ
Deletingȱaȱtagȱbyȱtheȱuserȱtagȱ
Adding a Proximity Tag
TheȱGrandȱMasterȱcanȱassignȱaȱtagȱtoȱanyȱuserȱinȱtheȱsystem.ȱEachȱproximityȱtagȱcanȱbeȱ
assignedȱtoȱonlyȱoneȱuser.ȱ
Toȱaddȱaȱproximityȱtag:ȱ
1.
Pressȱ
ȱ
2.
Enterȱyourȱuserȱcodeȱ
3.
UsingȱtheȱarrowȱkeysȱscrollȱtoȱtheȱoptionȱCodes/TagsȱfromȱtheȱUserȱFunctionsȱ
menuȱandȱpressȱ
ȱ
.ȱ
4.
ScrollȱtoȱProximityȱTagsȱandȱpressȱ
5.
SelectȱtheȱoptionȱNew/Change.ȱPress
6.
UsingȱtheȱarrowsȱscrollȱtoȱselectȱtheȱUserȱIndexȱnumberȱtoȱwhichȱyouȱwantȱtoȱ
assignȱaȱtag.ȱȱ
7.
Withinȱ10ȱseconds,ȱholdȱtheȱproximityȱtagȱatȱaȱdistanceȱofȱ1ȱtoȱ2ȱcm.ȱfromȱtheȱ
keypad’sȱkeys.ȱTheȱkeypadȱautomaticallyȱreadsȱtheȱproximityȱtagȱandȱsavesȱitȱ
intoȱtheȱsystem’sȱmemory.ȱOnceȱtheȱproximityȱtagȱhasȱbeenȱsuccessfullyȱ
recorded,ȱaȱlongȱconfirmationȱbeepȱsounds,ȱandȱaȱconfirmationȱmessageȱisȱ
displayed.ȱIfȱtheȱproximityȱtagȱisȱalreadyȱstoredȱinȱtheȱsystem’sȱmemory,ȱ3ȱerrorȱ
beepsȱwillȱsoundȱandȱaȱrejectȱmessageȱwillȱappear.ȱȱ
ȱ
ȱ
Page 25
.ȱȱ
ȱ
AgilityȱUserȱManualȱ
Deleting a proximity tag
Deletingȱproximityȱtagsȱcanȱbeȱdoneȱbyȱinȱtwoȱoptions:ȱ
Byȱuserȱnumber:ȱUseȱthisȱoptionȱtoȱdeleteȱaȱtagȱforȱwhichȱtheȱuserȱisȱknownȱ
Byȱtag:ȱUseȱthisȱoptionȱtoȱdeleteȱaȱtagȱforȱwhichȱtheȱuserȱisȱnotȱknownȱ
Toȱdeleteȱbyȱuser:ȱ
1.
Followȱstepsȱ1Ȭ4ȱofȱtheȱpreviousȱprocedureȱ(SeeȱSetting/ChangingȱUserȱCodes)ȱ
2.
3.
ScrollȱtheȱmenuȱtoȱtheȱoptionȱDeleteȱbyȱuser.ȱPressȱ
ȱ
Usingȱtheȱarrowsȱscrollȱtoȱselectȱtheȱuserȱforȱwhichȱyouȱwantȱtoȱdeleteȱtheȱ
proximityȱtagȱandȱpressȱ
4.
.ȱ
Theȱdisplayȱwillȱshow:ȱȈDeleteȱUser.ȱAreȱyouȱsure?Ȉ.ȱȱUseȱtheȱ
ȱkeyȱtoȱselectȱ
[Y]ȱandȱpressȱ
.ȱIfȱsuccessful,ȱaȱsingleȱconfirmationȱbeepȱisȱsounded,ȱifȱnot,ȱ3ȱ
quickȱerrorȱbeepsȱareȱsounded.ȱ
Toȱdeleteȱbyȱtag:ȱ
1.
Followȱstepsȱ1Ȭ4ȱofȱtheȱpreviousȱprocedureȱ(SeeȱSetting/ChangingȱUserȱCodes).ȱȱ
2.
3.
ScrollȱtheȱmenuȱtoȱtheȱoptionȱDeleteȱbyȱtag.ȱPressȱ
ȱ
Withinȱ10ȱseconds,ȱapproachȱtheȱproximityȱtagȱatȱaȱdistanceȱofȱ1ȱtoȱ2ȱcm.ȱfromȱ
theȱkeypad’sȱkeys.ȱAȱconfirmationȱmessageȱwillȱbeȱdisplayed.ȱ
4.3 Defining Follow Me Destinations
Inȱtheȱcaseȱofȱanȱalarmȱorȱevent,ȱtheȱsystemȱcanȱinitiateȱaȱphoneȱcallȱtoȱaȱdesignatedȱ
telephone,ȱsendȱaȱSMSȱorȱsendȱanȱEȬmailȱandȱemployȱuniqueȱtonesȱorȱmessagesȱtoȱexpressȱ
theȱactiveȱevent.ȱ
Toȱenter/editȱaȱFollowȱMeȱnumber:ȱ
1.
2.
Pressȱ
ȱ
Enterȱyourȱuserȱcodeȱ
3.
ScrollȱtheȱmenuȱusingȱtheȱarrowȱkeysȱtoȱtheȱoptionȱFollowȱMeȱandȱpressȱ
4.
SelectȱtheȱFollowȱMeȱindexȱnumberȱyouȱwantȱtoȱeditȱandȱpressȱ
5.
6.
ȱtoȱenterȱtheȱDefineȱmenu.ȱ
Pressȱ
Enterȱtheȱphoneȱnumber,ȱincludingȱtheȱareaȱcodeȱ(ifȱrequired)ȱorȱanȱeȬmailȱ
address,ȱasȱrequestedȱonȱtheȱscreenȱandȱpress
ȱ
.ȱ
ȱ
Upȱtoȱ32ȱdigitsȱcanȱbeȱincludedȱinȱtheȱphoneȱnumber.ȱ
7.
Ifȱrequired,ȱincludeȱtheȱspecialȱfunctionsȱdescribedȱbelowȱtoȱachieveȱtheȱrelatedȱ
effect.ȱYouȱcanȱpressȱthe
ȱȱorȱ
keysȱtoȱtoggleȱtoȱtheȱrequiredȱcharacter.ȱ
Page 26
AgilityȱUserȱManualȱ
ȱ
ȱ
Function
Results
Stopȱdialingȱandȱwaitȱforȱaȱnewȱdialȱtoneȱ
Wȱ
Waitȱaȱfixedȱperiodȱbeforeȱcontinuingȱ
,ȱ
SendȱtheȱDTMFȱ¾ȱcharacterȱ
¾ȱ
SendȱtheȱDTMFȱ#ȱcharacterȱ
#ȱ
Deleteȱnumbersȱfromȱtheȱcursorȱpositionȱ
8.
Whenȱdoneȱwithȱyourȱcompleteȱentry,ȱpress
ȱsimultaneouslyȱ
toȱstoreȱit.ȱȱ
4.4 Scheduler
TheȱAgilityȱenablesȱyouȱtoȱautomateȱsomeȱsystemȱoperations.ȱThisȱisȱperformedȱbyȱ
definingȱweeklyȱprogramsȱbyȱyourȱinstaller.ȱEachȱprogramȱcanȱbeȱdefinedȱwithȱupȱtoȱtwoȱ
timeȱintervalsȱperȱday,ȱduringȱwhichȱtheȱsystemȱautomaticallyȱperformsȱoneȱofȱtheȱ
followingȱfunctions:
AutomaticȱArming/Disarming:ȱAnȱarmingȱprogramȱautomaticallyȱarmsȱandȱ
disarmsȱtheȱsystemȱduringȱyourȱrequiredȱtimeȱintervals.ȱȱ
AutomaticȱUOȱActivation:ȱAȱUOȱ(homeȱappliance)ȱactivationȱprogramȱ
automaticallyȱactivatesȱandȱdeactivatesȱUOsȱduringȱyourȱrequiredȱintervals.ȱȱ
Inȱaddition,ȱeachȱprogramȱcanȱbeȱdefinedȱtoȱbeȱactivatedȱinȱaȱdifferentȱmannerȱduringȱ
vacation.ȱ
Onceȱyourȱinstallerȱdefinesȱaȱscheduleȱprogramȱitȱwillȱbeȱactivated.ȱȱ
Youȱhaveȱtheȱoptionȱtoȱdeactivateȱaȱprogramȱaccordingȱtoȱyourȱneeds.ȱ
Toȱdisableȱaȱweeklyȱprogram:ȱ
1.
Pressȱ
2.
Enterȱyourȱuserȱcodeȱ
3.
ScrollȱtheȱmenuȱusingȱtheȱarrowȱkeysȱtoȱtheȱoptionȱClockȱandȱpressȱ
4.
Pressȱ
5.
SelectȱtheȱSchedulingȱprogramȱindexȱnumber.ȱUseȱtheȱ
ȱ
ȱ
ȱtoȱenterȱtheȱSchedulerȱmenu.ȱ
deactivateȱandȱpressȱ
.ȱ
ȱ
Page 27
ȱkeyȱtoȱactivateȱ/ȱ
ȱ
AgilityȱUserȱManualȱ
4.5 Macro keys
Programming Macro Keys
AgilityȱenablesȱtheȱinstallerȱorȱGrandȱMasterȱtoȱrecordȱaȱseriesȱofȱcommandsȱandȱassignȱ
themȱtoȱaȱmacro.ȱWhenȱtheȱmacroȱisȱpressed,ȱtheȱrecordedȱcommandsȱareȱexecutedȱfromȱ
beginningȱtoȱend.ȱUpȱtoȱ3ȱmacrosȱcanȱbeȱprogrammedȱtoȱaȱsystemȱusingȱtheȱAgilityȱkeypadȱ
orȱtheȱAgilityȱConfigurationȱSoftware.ȱȱ
Beforeȱprogrammingȱaȱmacro,ȱitȱisȱrecommendedȱtoȱperformȱyourȱrequiredȱseriesȱofȱ
commands,ȱmakingȱaȱnoteȱofȱeveryȱkeyȱyouȱpressȱwhileȱdoingȱso.ȱ
Note:ȱMacrosȱcannotȱbeȱprogrammedȱtoȱperformȱdisarmingȱcommands.ȱ
Toȱprogramȱaȱmacro:ȱ
.ȱ
1.
InȱtheȱMacroȱmenuȱselectȱaȱmacroȱ(A,ȱBȱorȱC)ȱandȱpress
2.
Enterȱtheȱsequenceȱofȱcharactersȱaccordingȱtoȱtheȱfollowingȱtable:ȱ
Key
Represents
Usedȱtoȱenterȱnumericalȱcharactersȱ
ȱ
ȱ
Usedȱtoȱmoveȱtheȱcurserȱtoȱtheȱleftȱ
Usedȱtoȱmoveȱtheȱcurserȱtoȱtheȱrightȱ
ȱ
Pressȱ1ȱtwiceȱ
RepresentsȱtheȱÇȱcharacterȱ
Pressȱ3ȱtwiceȱ
RepresentsȱtheȱÈȱcharacterȱ
Pressȱ4ȱtwiceȱ
Representsȱtheȱ
ȱkeyȱ
Pressȱ6ȱtwiceȱ
Representsȱtheȱ
ȱkeyȱ
Pressȱ7ȱtwiceȱ
Representsȱtheȱ¾ȱcharacterȱ
Pressȱ9ȱtwiceȱ
Representsȱtheȱ#ȱcharacterȱ
ȱandȱ0ȱsimultaneouslyȱ
/
Deletesȱyourȱentryȱfromȱtheȱcursorȱpositionȱforwardȱ
Useȱtoȱtoggleȱbetweenȱ
numericȱcharactersȱ
/
/Ç/È/#/¾ȱandȱallȱofȱtheȱ
Usedȱtoȱendȱtheȱsequenceȱandȱsaveȱitȱtoȱmemoryȱ
Page 28
AgilityȱUserȱManualȱ
3.
ȱ
Press
ȱtoȱsaveȱyourȱentry.ȱȱ
Theȱseriesȱofȱcharactersȱisȱsavedȱandȱassignedȱtoȱtheȱselectedȱmacro.ȱ
ȱ
Forȱexample:ȱ
Toȱarmȱpartitionȱ1ȱwithȱtheȱcodeȱ1234,ȱenterȱtheȱfollowingȱsequence:ȱ
1ȱ
ȱ1ȱ2ȱ3ȱ4ȱȱ
Activating a Macro
Pressȱ7/8/9ȱonȱtheȱkeypadȱforȱ2ȱsecondsȱtoȱactivateȱtheȱmacroȱA/B/Cȱrespectively.ȱAȱ
confirmationȱmessageȱwillȱbeȱheard:ȱȱ
Ȉ[MacroȱX]ȱactivatedȈ.ȱ
Page 29
ȱ
AgilityȱUserȱManualȱ
4.6 Complete Menu of User Functions
TheȱAgilityȱcomesȱwithȱaȱvarietyȱofȱselectableȱuserȱfunctionsȱthatȱbecomeȱavailableȱwhenȱ
youȱenterȱtheȱUserȱFunctionsȱmode.ȱTheȱfollowingȱsectionȱlistsȱtheseȱfunctions.ȱȱ
Note:ȱAlthoughȱtheseȱfunctionsȱareȱinȱtheȱUserȱFunctionsȱmenu,ȱyouȱcanȱaskȱyouȱinstallerȱtoȱprogramȱsomeȱ
ofȱthemȱforȱyou.ȱ
ToȱenterȱtheȱUserȱFunctionsȱmodeȱpressȱ
ȱfollowedȱbyȱyourȱuserȱcode.ȱȱ
TheȱfollowingȱtableȱshowsȱfullȱKeypadȱOperationsȱaccordingȱtoȱusers.ȱ
ȱ
džȱȱȱȬȱUserȱisȱableȱtoȱperformȱthisȱfunctionȱ
ȬȱȱȱȬȱUserȱisȱunableȱtoȱperformȱorȱseeȱthisȱfunctionȱ
Operation
Grand
Master
User
Installer
džȱ
džȱ
Ȭȱ
MainȱBuzzerȱON/OFF:ȱUsedȱtoȱcontrolȱtheȱmainȱ
unitȱbuzzer.ȱ
džȱ
džȱ
džȱ
WalkȱTest:ȱUsedȱtoȱeasilyȱtestȱandȱevaluateȱtheȱ
operationȱofȱselectedȱzonesȱinȱyourȱsystemȱ
džȱ
Ȭȱ
džȱ
OutputȱControl:ȱAllowsȱuserȱcontrolȱofȱpreviouslyȱ
designatedȱexternalȱdevicesȱ(e.g.ȱanȱappliance,ȱaȱ
motorȬdrivenȱgarageȱdoor,ȱetc.)ȱ
OutputȱControlȱÆȱSelectȱOutputÆDefineȱ[Y]ȱ
džȱ
džȱ
Ȭȱ
BypassȱTroubles:ȱUsedȱtoȱconfirmȱallȱtroublesȱinȱtheȱ
systemȱinȱorderȱtoȱenableȱarmingȱoperation.ȱȱ
džȱ
džȱ
Ȭȱ
AntiȱCode:ȱIfȱdefinedȱbyȱyourȱengineerȱtheȱAgilityȱ
canȱbeȱdefinedȱtoȱbeȱnotȱreadyȱtoȱArmȱafterȱanȱ
alarmȱorȱtamperȱcondition.ȱToȱrestoreȱtheȱsystemȱtoȱ
Normal Operationȱmode,ȱinstallerȱcodeȱorȱanȱAntiȬ
codeȱmustȱbeȱentered.ȱEnteringȱtheȱcodeȱsuppliedȱ
byȱtheȱinstallerȱatȱthisȱlocationȱwillȱrestoreȱtheȱ
systemȱtoȱtheȱNormal Operationȱmodeȱ
džȱ
džȱ
Ȭȱ
Activitiesȱ
BypassȱZone:ȱProvidesȱtheȱabilityȱtoȱbypassȱanyȱofȱ
theȱsystemȇsȱintrusionȱzones.ȱ
BypassȱzoneȱÆȱSelectȱzoneȱÆȱDefineȱ[Y]ȱusingȱtheȱ
ȱkeyȱandȱpressȱ
usingȱtheȱ
ȱȱ
ȱkeyȱandȱpressȱ
ȱ
Page 30
AgilityȱUserȱManualȱ
ȱ
Operation
Grand
Master
User
Installer
AdvancedȱÆȱPrepaidȱSIMȱÆȱCheckȱCreditȱ
UseȱthisȱfunctionȱtoȱreceiveȱinformationȱbyȱSMSȱorȱ
VoiceȱofȱtheȱcreditȱlevelȱinȱyourȱprepaidȱSIMȱcard.ȱ
Forȱmoreȱinformationȱreferȱtoȱyourȱinstaller.ȱ
džȱ
Ȭȱ
Ȭȱ
AdvancedȱÆȱPrepaidȱSIMȱÆȱResetȱSIMȱ
AfterȱchargingȱaȱprepaidȱSIMȱcard,ȱtheȱuserȱhasȱtoȱ
resetȱtheȱSIMȱExpireȱTimeȱmanually.ȱTheȱtimeȱ
durationȱforȱexpirationȱisȱdefinedȱbyȱyourȱinstaller.ȱ
džȱ
Ȭȱ
Ȭȱ
AdvancedȱÆȱRestoreȱAlarm:ȱTheȱuserȱmustȱapproveȱ
anȱalarmȱthatȱoccurredȱinȱtheȱsystem.ȱAfterȱ
disarmingȱanȱalarm,ȱanȱAlarmȱMemoryȱDisplayȱwillȱ
appearȱonȱtheȱscreen.ȱȱ
džȱ
džȱ
Ȭȱ
AdvancedȱÆȱRestoreȱTrouble:ȱIfȱdefinedȱbyȱyourȱ
installer,ȱuseȱthisȱoptionȱtoȱresetȱaȱtroubleȱconditionȱ
afterȱitȱhasȱbeenȱcorrected.ȱȱȱ
džȱ
džȱ
Ȭȱ
AdvancedȱÆȱSirenȱTMPȱMute:ȱUsedȱtoȱsilenceȱanȱ
alarmȱinitiatedȱbyȱaȱtamperȱfromȱaȱsirenȱforȱ20ȱ
minutes.ȱUseȱthisȱoptionȱwhenȱreplacingȱtheȱsirenȱ
battery.ȱȱ
džȱ
Ȭȱ
džȱ
AdvancedȱÆȱViewȱIPȱAddress:ȱUseȱthisȱoptionȱtoȱ
viewȱtheȱIPȱaddressȱofȱtheȱAgility.ȱ
džȱ
Ȭȱ
Ȭȱ
AdvancedȱÆȱCSȱConnect:ȱEnablesȱtoȱestablishȱ
communicationȱwithȱtheȱconfigurationȱsoftwareȱatȱaȱ
predefinedȱlocationȱthroughȱIPȱorȱGPRS.ȱ
džȱ
Ȭȱ
džȱ
AdvancedȱÆȱExit/EntryȱBeeps:ȱEnablesȱtoȱcontrolȱ
theȱexit/entryȱbeepsȱofȱtheȱcurrentȱkeypad.
džȱ
Ȭȱ
džȱ
Define:ȱUsedȱtoȱdefineȱFollowȱMeȱdestinationsȱ
phoneȱnumberȱorȱEmailȱaddressȱaccordingȱtoȱitsȱ
type:ȱVoiceȱmessage,ȱSMSȱorȱEȬmailȱ
džȱ
Ȭȱ
džȱ
TestȱFM:ȱUsedȱtoȱtestȱFollowȱMeȱreporting.ȱ
džȱ
Ȭȱ
džȱ
džȱ
džȱ
Ȭȱ
FollowȱMeȱȱ
Codes/Tagsȱ
Useȱthisȱmenuȱtoȱsetȱtagsȱandȱuserȱcodesȱinȱtheȱ
system.ȱForȱdetailedȱinformationȱreferȱtoȱChapterȱ4,ȱ
pageȱ23.ȱȱ
Page 31
ȱ
AgilityȱUserȱManualȱ
Operation
Grand
Master
User
Installer
Timeȱ&ȱDate:ȱAllowsȱtheȱsettingȱofȱtheȱsystemȱtimeȱ
andȱdate.ȱThisȱdefinitionȱisȱrequiredȱforȱsettingȱtheȱ
schedulerȱprogrammingȱinȱtheȱsystem.ȱ
džȱ
Ȭȱ
džȱ
Scheduler:ȱEnablesȱyouȱtoȱactivateȱorȱdeactivateȱ
preprogrammedȱschedulesȱthatȱwereȱdefinedȱbyȱ
yourȱinstaller.ȱUpȱtoȱ8ȱweeklyȱprogramsȱcanȱbeȱ
definedȱinȱtheȱsystemȱduringȱwhichȱtheȱsystemȱ
automaticallyȱarmsȱ/ȱdisarmsȱorȱactivatesȱutilityȱ
outputs.ȱȱ
džȱ
Ȭȱ
džȱ
Clockȱ
EventȱLogȱ
ȱ
ȱ
ȱ
ȱToȱviewȱaȱlistȱofȱsystemȱeventsȱthatȱhaveȱoccurredȱ
džȱ
Ȭȱ
džȱ
ServiceȱInformationȱȱ
ȱ
ȱ
ȱ
Allowsȱtheȱdisplayȱofȱanyȱpreviouslyȱenteredȱ
serviceȱinformation.ȱ(Nameȱandȱphone)ȱȱ
džȱ
džȱ
Ȭȱ
Macroȱȱ
ȱ
ȱ
ȱ
AgilityȱenablesȱtheȱinstallerȱorȱGMȱtoȱrecordȱaȱseriesȱ
ofȱcommandsȱandȱassignȱthemȱtoȱaȱmacro.ȱForȱmoreȱ
informationȱreferȱtoȱsectionȱ4.5ȱMacroȱkeysȱpageȱ28.ȱ
džȱ
Ȭȱ
džȱ
ȱȱ
ȱ
Page 32
AgilityȱUserȱManualȱ
ȱ
Chapter 5 - System Specifications
TheȱfollowingȱtechnicalȱspecificationsȱareȱapplicableȱforȱtheȱAgility:ȱȱ
Electrical Characteristics
SystemȱPower
230VACȱ(Ȭ15%+10%),ȱ50Hz,ȱ50mA
Optional:ȱ9VAC,ȱ50Ȭ60Hz
UnitsȱConsumptionsȱȱ
Mainȱboard:ȱTypicalȱ130mAȱ
GSM:ȱStandȱbyȱ35mA,ȱCommunicationȱ300mAȱ
Modem:ȱStandȱbyȱ20mA,ȱCommunicationȱ60mAȱȱ
IPȱCard:ȱ90mAȱ(Max)ȱ
BackupȱBattery
SealedȱLeadȱAcidȱBatteryȱ6Vȱ3.2Ahȱ
BatteryȱDimensionsȱ(HxWxD) 67mmȱxȱ134mmȱxȱ34mmȱ
InternalȱSirenȱintensity
90ȱdBAȱ@ȱ1m
OperatingȱTemperature
Ȭ10qCȱtoȱ40qCȱ(14qFȱtoȱ104qF)ȱ
Storageȱtemperatureȱ
Ȭ20°Cȱtoȱ60°Cȱ(Ȭ4°Fȱtoȱ140°F)ȱ
Physical Characteristics
Dimensionȱ(HxWxD)
268.5ȱmmȱxȱ219.5ȱmmȱxȱ64ȱmmȱȱ
(10.57ȱxȱ8.64ȱxȱ2.52ȱinch)
Weightȱ(Withoutȱbattery)
1.31Kgȱ(Fullȱconfiguration)
Wireless Characteristics
RFȱimmunity
AccordingȱtoȱENȱ50130Ȭ4
Frequency
868.65ȱMHzȱorȱ433.92ȱMHzȱ
Page 33
ȱ
AgilityȱUserȱManualȱ
Chapter 6 - EN 50131 Compliance
Compliance Statement
Hereby,ȱRISCOȱGroupȱdeclaresȱthatȱtheȱAgilityȱseriesȱofȱcentralȱunitsȱandȱaccessoriesȱareȱ
designedȱtoȱcomplyȱwith:ȱ
EN50131Ȭ1,ȱEN50131Ȭ3ȱGradeȱ2ȱ
EN50130Ȭ5ȱEnvironmentalȱclassȱIIȱȱ
EN50131Ȭ6ȱTypeȱAȱ
UK:ȱPDȱ6662:2004,ȱACPOȱDD243:2004ȱ(Police)ȱȱȱ
Possible logical keys calculations:
Logicalȱcodesȱareȱcodesȱtypedȱinȱtheȱwirelessȱkeypadȱtoȱallowȱlevelȱ2ȱ(users)ȱandȱ
levelȱ3ȱ(installer)ȱaccessȱ
Allȱcodeȱlengthsȱareȱ4ȱdigitsȱlongȱ
0Ȭ9ȱcanȱbeȱusedȱforȱeachȱdigitȱ
Thereȱareȱnoȱdisallowedȱcodes,ȱallȱcodesȱfromȱ0001ȱtoȱ9999ȱareȱacceptableȱ
Invalidȱcodesȱcannotȱbeȱcreatedȱsinceȱafterȱ4ȱdigitsȱhaveȱbeenȱtypedȱȈEnterȈȱisȱ
automatic.ȱCodesȱrejectionȱoccursȱonlyȱwhenȱtryingȱtoȱcreateȱaȱcodeȱthatȱdoesȱnotȱ
exist.ȱ
Possible physical keys calculations:
PhysicalȱkeysȱareȱimplementedȱinȱtheȱWirelessȱRemoteȱControls.ȱ
Itȱisȱassumedȱonlyȱaȱuserȱcanȱhaveȱremoteȱcontrols,ȱsoȱhavingȱaȱphysicalȱkeyȱisȱ
consideredȱasȱaccessȱlevelȱ2ȱ
Eachȱremoteȱcontrolȱhasȱanȱidentificationȱcodeȱofȱ24ȱbit,ȱsoȱtheȱnumberȱofȱoptionsȱisȱ
2^24ȱ
ForȱaȱremoteȱcontrolȱtoȱoperateȱwithȱtheȱAgility,ȱaȱȈwriteȈȱprocessȱmustȱbeȱmadeȱ
afterȱwhichȱtheȱkeypadȱisȱregisteredȱwithȱtheȱpanel.ȱ
AȱvalidȱremoteȱcontrolȱisȱoneȱȈLearnedȈȱbyȱtheȱpanelȱandȱallowsȱArm/Disarmȱ
AȱnonȱvalidȱremoteȱcontrolȱisȱoneȱnotȱȈLearnedȈȱbyȱtheȱpanelȱandȱdoesȱnotȱallowȱ
Arm/Disarmȱ
Page 34
AgilityȱUserȱManualȱ
ȱ
Appendix A - Keypad User Operations
Theȱfollowingȱsectionȱdetailsȱtheȱuserȱoperationsȱfromȱtheȱ2Ȭwayȱwirelessȱkeypad.ȱUserȱ
operationȱcanȱbeȱdefinedȱtoȱbeȱactivatedȱbyȱaȱquickȱmodeȱorȱhighȱsecurityȱmodeȱthatȱ
requiresȱtheȱuseȱofȱaȱcodeȱorȱproximityȱtag.ȱ
Inȱtheȱhighȱsecurityȱmodeȱtheȱproximityȱtagȱcanȱbeȱusedȱasȱaȱsubstituteȱforȱinsertingȱaȱuserȱ
codeȱwhenȱtheȱdisplayȱpromptsȱtoȱȈInsertȱaȱcodeȈ.ȱȱ
Common Operations
Operation
Quick Operation
High Security Mode 1
AwayȱArmȱ
Pressȱ
ȱ
Pressȱ
ȱfollowedȱbyȱcodeȱorȱproximityȱtagȱ2ȱ
Pressȱ
ȱ
Press
ȱfollowedȱbyȱcodeȱorȱproximityȱtagȱ
StayȱArmȱ3ȱ
ȱ
FullȱDisarmȱ
ȱfollowedȱbyȱcodeȱorȱproximityȱtagȱ
Pressȱ
1. Consultȱyourȱinstallerȱforȱtheȱoperationsȱdefinedȱwithȱaȱcodeȱ
2. Forȱoptimalȱuseȱofȱtheȱproximityȱtag,ȱuseȱitȱfromȱaȱdistanceȱofȱ1Ȭ2ȱcmȱ(0.4ȈȱȬȱ0.7Ȉ)ȱfromȱtheȱcenterȱofȱtheȱ
keypadȇsȱdoorȱ
3. ForȱStayȱArmingȱwithȱnoȱentryȱdelayȱpressȱtheȱ
ȱkeyȱforȱtwoȱsecondsȱ
Advanced Operations
Operation1
Quick Operation
AwayȱArmingȱ
Partitionȱ1/2/3ȱ
Selectȱpartitionȱ
/
/
High Security Mode
Selectȱpartitionȱ
andȱpressȱ
ȱ
StayȱArmingȱ
Partitionȱ1/2/3ȱ
Selectȱpartitionȱ
/
/
Panicȱalarmȱ/ȱServiceȱ
callȱȱ
FireȱAlarmȱ
ȱandȱ
pressȱȱȱ
followedȱbyȱcodeȱorȱ
proximityȱtagȱ
Selectȱpartitionȱ
/
/
andȱ
pressȱȱȱ
ȱȱfollowedȱbyȱcodeȱorȱ
proximityȱtagȱ
/
/
Selectȱpartitionȱ
codeȱorȱtheȱproximityȱtagȱ
Pressȱbothȱkeysȱ
Pressȱ
/
andȱpressȱ
ȱ
Partitionȱ1/2/3ȱȱ
Disarmȱȱ
/
ȱ
andȱpressȱȱ
ȱȱsimultaneouslyȱ4ȱ
ȱsimultaneouslyȱforȱ2ȱsecondsȱ
Page 35
ȱfollowedȱbyȱtheȱ
ȱ
AgilityȱUserȱManualȱ
Operation1
Quick Operation
Emergency/Medicalȱ
Alarmȱ
Pressȱ
SystemȱChimeȱ
On/Offȱ
Pressȱtheȱbuttonȱȱ
MainȱUnitȱSpeakerȱ
Volumeȱ
SetȱkeypadȱLCDȱ
contrastȱ
ȱsimultaneouslyȱforȱ2ȱsecondsȱ
Pressȱ
ȱtoȱsaveȱyourȱselectionȱ
Pressȱ
forȱ2ȱsecondsȱ
ȱ
pressȱ
ȱkeysȱtoȱadjustȱtheȱkeypadȇsȱdisplayȱcontrastȱandȱ
ȱ
Pressȱbuttonȱ
/
ViewȱLastȱAlarmȱ
ȱforȱ2ȱsecondsȱ
Pressȱtheȱbuttonȱ
ȱforȱ2ȱsecondsȱ
Selectȱtheȱvolumeȱlevelȱ(0=Noȱsound,ȱ4=Fullȱvolume)ȱ
Useȱtheȱ
OutputȱȱControlȱ
A/B/Cȱ2ȱ
High Security Mode
/
forȱ2ȱsecondsȱ
Holdȱbuttonȱ
Pressȱbuttonȱ
/
/
ȱforȱ2ȱ
secondsȱfollowedȱbyȱcodeȱorȱ
proximityȱtagȱ
ȱforȱtwoȱsecondsȱ
ViewȱSystemȱStatusȱ
OnlyȱLCDȱdisplayȱ:ȱShortȱpressȱonȱȱ
Shortȱpressȱonȱȱ
displayȱ
:ȱLCDȱ
Longȱpressȱonȱ
displayȱ+ȱvoiceȱ
:ȱLCDȱ
ȱfollowedȱbyȱcodeȱorȱproximityȱ
tagȱ
LCDȱdisplayȱ+ȱvoice:ȱLongȱpressȱonȱ
ȱfollowedȱbyȱcodeȱorȱproximityȱ
tagȱ
MacroȱActivationȱ3ȱ
WakeȱupȱKeypadȱ
/
Pressȱȱ
/
ȱforȱ2ȱsecondsȱ
Pressȱ
ȱ
UpdateȱKeypadȱ
Parametersȱ
Pressȱ
ȱforȱ2ȱsecondsȱafterȱchangingȱparametersȱinȱtheȱsystemȱ
EnterȱProgrammingȱ
Modeȱ
Pressȱ
andȱenterȱtheȱcodeȱ
ChangingȱKeypadȱ
Languageȱ
Pressȱ
ȱsimultaneouslyȱforȱ2ȱseconds.ȱSelectȱtheȱlanguageȱ
andȱpressȱ
ȱtoȱconfirm.ȱ
ȱ
Page 36
AgilityȱUserȱManualȱ
ȱ
1. Allȱoperationsȱareȱavailableȱwhileȱkeypadȱisȱturnedȱonȱ(NotȱinȱSleepȱMode)ȱ
2. Askȱyourȱinstallerȱwhetherȱoutputsȱcontrolȱisȱapplicableȱorȱnotȱandȱwhichȱoutputȱisȱassignedȱtoȱwhichȱ
keyȱ
3. Askȱyourȱinstallerȱforȱtheȱmacroȱdefinedȱforȱeachȱkeyȱȱ
4. Askȱyourȱinstallerȱforȱtheȱkeysȱdefinitionȱȱ
LEDs Indication
Key
Function
Communicationȱwithȱtheȱpanelȱ
ȱȱ(Blue)ȱ
On:ȱFullyȱorȱpartiallyȱarmedȱ
ȱȱ
(Red)
ȱ
Slowȱflash:ȱExitȱdelayȱ
Rapidȱflash:ȱAlarmȱ
Troubleȱinȱtheȱsystemȱduringȱdisarmȱmodeȱȱ
ȱȱȱȱȱ
(Yellow)
ȱ
ȱ
Page 37
ȱ
AgilityȱUserȱManualȱ
Appendix B - Remote Control User Operations
TheȱfollowingȱsectionȱdetailsȱtheȱuserȱoperationsȱfromȱtheȱAgilityȱ2ȬWayȱRemoteȱControl.ȱ
Userȱoperationȱcanȱbeȱdefinedȱtoȱbeȱactivatedȱbyȱaȱquickȱmodeȱorȱhighȱsecurityȱmodeȱthatȱ
requiresȱtheȱuseȱofȱaȱcode.ȱȱȱȱ
Common Operations
Operation
High Security Mode 1
Quick
AwayȱArmȱ
StayȱArmȱ2ȱȱȱ
ȱ
ȱ>ȱCodeȱ
ȱ
ȱ>ȱCodeȱ
FullȱDisarmȱ
ȱ>ȱCodeȱ
ȱ
SystemȱStatusȱ3ȱ
Longȱ
OutputȱȱControlȱ4ȱȱA/B/Cȱ
Longȱȱ
PanicȱAlarmȱ
ClearȱOperationȱ5ȱ
4\?
ȱ
Longȱ
ȱ/ȱ
ȱ/ȱ
ȱ
4\?
ȱ>ȱCodeȱ
Longȱȱ
ȱ/ȱ
ȱ+ȱ
ȱsimultaneouslyȱforȱ2ȱsecondsȱ
ȱ>ȱ
ȱ
ȱ/ȱ
ȱ>ȱCodeȱ
ȱ
1
Consultȱyourȱinstallerȱwhichȱcommandsȱareȱdefinedȱwithȱaȱcode.ȱȱ
2
Pressingȱ
3
4
5
>ȱ
ȱwillȱcancelȱtheȱEntryȱDelayȱtime.ȱ
4\?
Pressingȱ
>ȱ
ȱwillȱgiveȱstatusȱindicationȱonlyȱbyȱtheȱLEDȱofȱtheȱremoteȱcontrolȱandȱnotȱbyȱ
localȱvoiceȱmessage.ȱ
Askȱyourȱinstallerȱwhichȱdeviceȱisȱassignedȱtoȱwhichȱkey.ȱ
Useȱthisȱcommandȱtoȱclearȱtheȱremoteȱcontrolȱoperation.ȱȱȱ
Advanced Operations
Operation
AwayȱPartitionȱ1/2/3ȱ
Armingȱȱ
StayȱPartitionȱ1/2/3ȱ
Armingȱ
Partionȱ1/2/3ȱDisarmȱȱ
Quick
Code Sequence
ȱ/ȱ
ȱ/ȱ
ȱ>ȱ
ȱ
ȱ/ȱ
ȱ/ȱ
ȱ>ȱ
ȱ>ȱCodeȱ
ȱ/ȱ
ȱ/ȱ
>ȱ
ȱ
ȱ/ȱ
ȱ/ȱ
ȱ>ȱ
ȱCodeȱ
ȱ/ȱ
ȱ/ȱ
ȱ>ȱ
ȱ/ȱ
ȱ/ȱ
ȱ>ȱ
ȱ>ȱCodeȱ
Page 38
ȱ
AgilityȱUserȱManualȱ
ȱ
Status LED/Buzzer Indications
Afterȱeachȱtransmissionȱ(indicatedȱbyȱaȱflashingȱGreenȱLED)ȱfromȱtheȱremoteȱcontrol,ȱtheȱ
AgilityȱsendsȱaȱstatusȱresponseȱindicatedȱbyȱtheȱremoteȱcontrolȇsȱLEDsȱandȱBuzzer:ȱ
LED Indications
Operation
1st LED *
(Send command)
Greenȱ
Greenȱ
Greenȱ
Greenȱ
AwayȱArmȱȱ
StayȱArmȱ
Disarmȱȱ
Alarmȱ
2nd LED
(Receive Status)
Redȱ
Orangeȱ
Greenȱ
FlashȱRedȱLEDȱ
*Ifȱtheȱ1stȱLEDȱchangesȱtoȱorangeȱitȱindicatesȱaȱlowȱbatteryȱcondition.ȱ
Buzzer Indications
Sound
Status
1ȱbeepȱ
Confirmationȱ
3ȱbeepsȱ
Errorȱ
5ȱbeepsȱ
Alarmȱ
Changing Remote Control PIN Code
EachȱremoteȱcontrolȱcanȱbeȱdefinedȱbyȱyourȱinstallerȱtoȱbeȱactivatedȱwithȱaȱuniqueȱPINȱ
code.ȱȱ
ToȱchangeȱtheȱremoteȱcontrolȱPINȱcodeȱ(fromȱtheȱremoteȱcontrolȱitself):ȱȱ
Note:ȱToȱchangeȱtheȱPINȱcodeȱitȱisȱmandatoryȱtoȱperformȱtheȱfollowingȱprocedureȱinȱcloseȱproximityȱtoȱtheȱ
controlȱpanel.ȱ
4\?
1.
2.
Pressȱtheȱ
+ȱ
ȱsimultaneouslyȱforȱ2ȱseconds.ȱ
Enterȱtheȱremoteȱcontrolȱcurrentȱ4ȱdigitȱPINȱcode.ȱ
3.
Press
ȱfollowedȱbyȱaȱnewȱ4ȱdigitȱcode.ȱȱ
.ȱ
4. Press
Theȱpanelȱwillȱsendȱaȱconfirmationȱmessage.ȱTheȱremoteȱcontrolȱwillȱsoundȱaȱlongȱbeepȱ
andȱtheȱGreenȱLEDȱwillȱturnȱon.ȱIfȱnoȱconfirmationȱsoundȱisȱheardȱtheȱoldȱPINȱcodeȱwillȱ
remain.ȱRepeatȱtheȱprocedureȱagainȱtoȱreplaceȱtoȱaȱnewȱcode.ȱ
ȱ
ȱ
Page 39
ȱ
AgilityȱUserȱManualȱ
Appendix C - Event Log Messages
EventȱMessageȱ
ActivateȱUO=xxȱȱȱ
ActvȱUO=xxȱKF=zzȱ
AlarmȱabortȱP=yȱȱ
Descriptionȱ
UOȱXXȱactivationȱ
UOȱXXȱisȱactivatedȱfromȱremoteȱcontrolȱZZȱ
AlarmȱabortedȱonȱpartitionȱYȱ
AlarmȱZone=xxȱȱȱȱ
AntiȬcodeȱresetȱȱ
AutoȱAddȱGSMȱȱȱȱȱ
AutoȱAddȱIPȱcardȱ
AutoȱAddȱMODEMȱȱȱ
AutoȱDelȱGSMȱȱȱȱȱ
AutoȱDelȱIPȱcardȱ
AutoȱDelȱMODEMȱȱȱ
Autoȱtestȱfailȱȱȱ
AutoȱtestȱOKȱȱȱȱȱ
AwayȱfailȱP=yȱȱȱȱ
Away:P=yȱC=zzȱȱȱȱ
Alarmȱinȱzoneȱno.ȱXXȱ
Remoteȱresetȱ
GSMȱModuleȱaddedȱtoȱtheȱmainȱunitȱ
IPȱModuleȱaddedȱtoȱtheȱmainȱunitȱ
Modemȱaddedȱtoȱtheȱmainȱunitȱ
GSMȱModuleȱwasȱremovedȱfromȱtheȱmainȱunitȱ
IPȱModuleȱremovedȱfromȱtheȱmainȱunitȱ
Modemȱremovedȱfromȱtheȱmainȱunitȱ
FailureȱofȱzoneȱselfȬtestȱ
AutomaticȱzoneȱselfȬtestȱOKȱ
PartitionȱYȱfailedȱtoȱarmȱ
PartitionȱYȱarmedȱbyȱuserȱno.ȱZZȱ
Away:P=yȱKF=zzȱȱȱ
Bellȱtamperȱȱ
Bellȱtamperȱrstȱȱ
Boxȱtamperȱȱȱȱȱȱȱ
Boxȱtamperȱrstȱȱȱ
PartitionȱYȱarmedȱbyȱremoteȱcontrolȱZZȱ
Bellȱtamperȱalarmȱ
Bellȱtamperȱalarmȱrestoreȱ
Boxȱtamperȱalarmȱfromȱmainȱunitȱ
Boxȱtamperȱalarmȱrestoreȱ
BypassȱBox+Bellȱȱ
BypassȱTrblȱC=xxȱ
BypassȱZone=xxȱȱȱ
CancelȱAlarmȱP=xȱ
Boxȱ+ȱBellȱtamperȱisȱbypassedȱ
SystemȱtroublesȱwereȱbypassedȱbyȱuserȱXXȱ
Zoneȱno.ȱXXȱisȱbypassedȱ
CancelȱalarmȱeventȱhasȱoccurredȱfromȱpartitionȱX.ȱAȱvalidȱuserȱ
functionȱisȱenteredȱtoȱresetȱtheȱalarmȱafterȱtheȱdefinedȱAbortȱalarmȱ
timeȱ
ChangingȱuserȱcodeȱXXȱ
ChangingȱFollowȬMeȱnumberȱYYȱ
ChangingȱkeypadȱtagȱforȱuserȱXXȱ
Timeȱisȱnotȱsetȱ
Timeȱdefinedȱbyȱuserȱno.ȱXXȱ
COȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱCOȱdetectorȱ
COȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱCOȱdetectorȱ
CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱIPȱcardȱ
CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱSirenȱYȱ
CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱGSMȱ
CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱI/Oȱmoduleȱ
ConfirmedȱalarmȱoccurredȱinȱpartitionȱYȱ
Changeȱcode=xxȱȱȱ
ChangeȱFM=yyȱȱȱȱȱ
Changeȱtag=xxȱȱȱȱ
Clockȱnotȱsetȱȱȱȱ
ClockȱsetȱC=xxȱȱȱ
COȱAlarmȱZn=xxȱȱȱ
COȱRst.ȱZn=xxȱȱȱȱ
ComȱokȱIPȱcardȱȱȱ
CommȱOKȱSiren=yȱ
Comm.ȱOKȱGSMȱȱȱȱȱ
Comm.OKȱI/OȱMdl.ȱ
Conf.ȱalarmȱP=yȱȱ
Page 40
AgilityȱUserȱManualȱ
EventȱMessageȱ
ConfirmȱrsȱZ=xxȱȱ
ConfirmȱZone=xxȱȱ
CPȱresetȱȱȱȱȱȱȱȱȱ
DateȱsetȱC=xxȱȱȱȱ
DayȱAway:P=yȱȱȱȱȱ
Dayȱdisarm:P=yȱȱȱ
Dayȱstay:ȱP=yȱȱȱȱȱ
Disarm:P=yȱC=zzȱȱ
Disarm:ȱP=yȱKF=zzȱ
DuressȱC=xxȱȱȱȱȱȱ
Enterȱprogramȱȱȱȱ
ȱ
Falseȱcodeȱȱȱȱȱȱȱ
Descriptionȱ
Restoreȱzoneȱconfirmedȱalarmȱ
ConfirmedȱalarmȱoccurredȱfromȱzoneȱXXȱ
Theȱcontrolȱpanelȱhasȱresetȱ
Dateȱdefinedȱbyȱuserȱno.ȱXXȱ
DailyȱarmȱonȱpartitionȱYȱ
DailyȱdisarmȱonȱpartitionȱYȱ
DailyȱSTAYȱarmingȱinȱpartitionȱYȱ
PartitionȱYȱdisarmedȱbyȱuserȱZZȱ
PartitionȱYȱdisarmedȱbyȱremoteȱcontrolȱZZȱ
Duressȱalarmȱfromȱuser no.ȱXXȱ
Enteringȱinstallerȱprogrammingȱfromȱkeypadȱorȱconfigurationȱ
softwareȱ
ExitȱerrorȱeventȱfromȱzoneȱXXȱ
Theȱzoneȱwasȱleftȱopenȱatȱtheȱendȱofȱtheȱexitȱtimeȱ
Exitingȱinstallerȱprogrammingȱfromȱkeypadȱorȱconfigurationȱ
softwareȱ
Falseȱcodeȱalarmȱ
Falseȱrestoreȱȱȱȱ
FireȱKeypad=yȱȱȱȱ
FireȱokȱZone=xxȱȱ
FireȱtrblȱZn=xxȱȱ
FireȱZone=xxȱȱȱȱȱ
FoilȱokȱZ=xxȱȱȱȱȱ
Falseȱcodeȱalarmȱrestoreȱ
FireȱalarmȱfromȱwirelessȱkeypadȱYȱ
Troubleȱrestoreȱinȱfireȱzoneȱno.ȱXXȱ
Troubleȱinȱfireȱzoneȱno.ȱXXȱ
Fireȱalarmȱinȱzoneȱno.ȱXXȱ
Restoreȱinȱfoilȱ(Day)ȱzoneȱno.ȱXXȱ
FoilȱZone=xxȱȱȱȱȱ
ForcedȱȱP=yȱȱȱȱȱȱ
FoundȱZone=xxȱȱȱȱ
GasȱAlarmȱZn=xxȱȱ
GasȱRst.ȱZn=xxȱȱȱ
GSM:ȱModuleȱcomm.ȱ
GSM:NETȱavail.ȱȱȱ
GSM:NETȱavail.OKȱ
GSM:NETȱqual.OKȱȱ
GSM:NETȱqualityȱȱ
Troubleȱinȱfoilȱ(Day)ȱzoneȱno.ȱXXȱ
PartitionȱYȱisȱforceȱarmedȱ
Wirelessȱzoneȱfound,ȱzoneȱno.ȱXXȱ
Gasȱ(naturalȱgas)ȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱgasȱdetectorȱ
Gasȱ(naturalȱgas)ȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱgasȱ
detectorȱ
IPȱconnectionȱOKȱ
IPȱaddressȱisȱincorrectȱ
CommunicationȱbetweenȱtheȱGSM/GPRSȱModuleȱandȱtheȱAgilityȱisȱ
OKȱ
InternalȱGSM/GPRSȱBUSȱmoduleȱtroubleȱ
GSMȱnetworkȱisȱnotȱavailableȱ
GSMȱNetworkȱisȱavailableȱ
GSMȱNetworkȱqualityȱisȱacceptableȱ
TheȱGSMȱRSSIȱlevelȱisȱlowȱ
GSM:PINȱcodeȱerrȱ
GSM:PINȱcodeȱOKȱȱ
GSM:PUKȱCodeȱerrȱ
PINȱcodeȱenteredȱisȱincorrectȱ
PINȱcodeȱisȱcorrectȱ
PUKȱcodeȱrequiredȱ
ExitȱErrorȱZn=xxȱ
Exitȱprogramȱȱȱȱȱ
GSM:IPȱOKȱȱȱȱȱȱȱȱ
GSM:IPȱTroubleȱȱȱ
GSM:Mdlȱcomm.OKȱȱ
Page 41
ȱ
EventȱMessageȱ
GSM:PUKȱCodeȱOKȱȱ
GSM:SIMȱOKȱȱȱȱȱȱȱ
GSM:SIMȱtroubleȱȱ
H.TempȱrstȱZn=xxȱ
AgilityȱUserȱManualȱ
IPC:DHCPȱerrorȱȱȱ
IPC:DHCPȱokȱȱȱȱȱȱ
Descriptionȱ
PUKȱCodeȱenteredȱisȱcorrect
SIMȱCardȱinȱplaceȱ
SIMȱcardȱmissingȱorȱnotȱproperlyȱsitedȱ
HighȱtemperatureȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱ
temperatureȱdetectorȱ
HighȱtemperatureȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱtemperatureȱ
detectorȱ
ACȱpowerȱrestoreȱonȱI/Oȱmoduleȱ
ACȱpowerȱtroubleȱonȱI/Oȱmoduleȱ
I/Oȱmoduleȱbatteryȱtroubleȱrestoredȱȱ
I/Oȱmoduleȱbatteryȱtroubleȱalertȱ
I/Oȱmoduleȱjammingȱalertȱ
I/Oȱmoduleȱjammingȱalertȱrestoredȱ
I/Oȱmoduleȱisȱregardedȱasȱlostȱfollowingȱsupervisionȱtestȱ
I/Oȱmoduleȱtamperȱalertȱ
I/Oȱmoduleȱtamperȱalertȱrestoredȱ
TheȱAgilityȱreceivedȱaȱsignalȱfromȱI/Oȱmoduleȱafterȱitȱhasȱbeenȱ
regardedȱasȱlostȱ
FailedȱtoȱacquireȱanȱIPȱaddressȱfromȱtheȱDHCPȱserverȱ
SucceededȱtoȱacquireȱanȱIPȱaddressȱfromȱtheȱDHCPȱserverȱ
IPC:ȱNetworkȱerrȱȱ
IPC:ȱNetworkȱokȱȱȱ
IPC:NTPȱerrorȱȱȱȱ
IPC:NTPȱokȱȱȱȱȱȱȱ
JammingȱOKȱZn=xxȱ
Jammingȱrestoreȱȱ
FailedȱtoȱconnectȱtoȱIPȱnetworkȱ
SuccessfulȱconnectionȱtoȱIPȱnetworkȱ
Failedȱtoȱacquireȱtimeȱdataȱfromȱtheȱtimeȱserverȱ
Succeededȱtoȱacquireȱtimeȱdataȱfromȱtheȱtimeȱserverȱ
ZoneȱXXȱjammingȱOKȱ
Wirelessȱreceiverȱȱjammingȱrestoreȱ
JammingȱZ=xxȱȱȱȱȱ
KP=yȱLowȱBat.Rstȱ
KP=yȱLowȱBatteryȱ
Kswȱaway:P=yȱȱȱȱȱ
Kswȱdisarm:P=yȱȱȱ
L.batȱrstrȱKF=yyȱ
L.TempȱrstȱZn=xxȱ
ZoneȱXXȱjammingȱtroubleȱ
LowȱbatteryȱtroubleȱrestoredȱfromȱkeypadȱYȱ
LowȱbatteryȱtroubleȱfromȱkeypadȱYȱ
PartitionȱYȱisȱarmedȱbyȱkeyȱswitchȱ
PartitionȱYȱisȱdisarmedȱbyȱkeyȱswitchȱ
LowȱbatteryȱtroubleȱrestoreȱfromȱwirelessȱremoteȱcontrolȱYYȱ
LowȱtemperatureȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱ
temperatureȱdetectorȱ
Wirelessȱzoneȱlost,ȱzoneȱno.ȱXXȱ
Lowȱbatteryȱtroubleȱrestoredȱfromȱwirelessȱzoneȱno.ȱXXȱ
Lowȱbatteryȱtroubleȱfromȱwirelessȱzoneȱno.ȱXXȱ
LowȱbatteryȱtroubleȱfromȱwirelessȱremoteȱcontrolȱXXȱ
LowȱtemperatureȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱtemperatureȱ
detectorȱ
ACȱpowerȱrestoreȱonȱmainȱpanelȱ
HighȱTemp.ȱZn=xxȱ
I/O:ACȱRstrȱȱȱȱȱȱ
I/O:ACȱTroubleȱȱȱ
I/O:ȱBatteryȱRstrȱ
I/O:ȱBatteryȱTrblȱ
I/O:ȱJammingȱȱȱȱȱȱ
I/O:ȱJammingȱRstrȱ
I/O:ȱLostȱȱȱȱȱȱȱȱȱ
I/O:ȱTamperȱȱȱȱȱȱȱ
I/O:ȱTamperȱRstrȱȱ
IO:ȱLostȱRestoreȱȱ
LostȱZone=xxȱȱȱȱȱ
LowȱBatȱrsȱZ=xxȱȱ
Lowȱbat.ȱZn=xxȱȱȱ
Lowȱbat.KF=yyȱȱȱȱ
LowȱTemp.ȱZn=xxȱȱ
Main:ACȱrestoreȱȱ
Page 42
AgilityȱUserȱManualȱ
ȱ
EventȱMessageȱ
Main:ȱBatteryȱrstȱ
Descriptionȱ
Lowȱbatteryȱtroubleȱrestoreȱfromȱtheȱmainȱpanelȱ
Main:ȱLowȱACȱȱȱȱȱȱ
Main:ȱLowȱbatteryȱ
MS=yȱcallȱerrorȱȱ
MS=yȱrestoreȱȱȱȱȱ
MsgȱBoxȱTamperȱ
MsgȱBoxȱTmpȱRst.ȱ
NoȱComȱIPȱcardȱȱȱ
NoȱcommȱI/OȱMdl.ȱ
NoȱcommȱSiren=yȱȱ
Noȱcomm.ȱGSMȱȱȱȱȱ
Phoneȱfailȱȱȱȱȱȱȱ
Phoneȱrestoreȱȱȱȱ
PoliceȱKeypad=yȱȱ
PoliceȱKF=yyȱȱȱȱȱ
PTM:ȱSendȱDataȱȱȱȱ
Radioȱl.batȱȱS=yȱ
Radioȱl.batȱrS=yȱ
Remoteȱaway:P=yȱȱ
Remoteȱprogramȱȱȱ
Remoteȱstay:P=yȱȱ
SoakȱfailȱZ=xxȱȱȱ
SpecialȱKP=yȱȱȱȱȱ
Spkrȱl.batȱrsS=yȱ
SpkrȱlowȱbatȱS=yȱ
StartȱexitȱP=yȱȱȱ
Stay:P=yȱC=zzȱȱȱȱ
Stay:ȱP=yȱKF=zzȱȱȱ
TamperȱI/OȱMdl.ȱȱ
TamperȱI/OȱMdl.ȱȱȱ
LossȱofȱACȱpowerȱfromȱtheȱmainȱpanelȱ
Lowȱbatteryȱtroubleȱfromȱtheȱmainȱpanelȱ
CommunicationȱfailȱtroubleȱtoȱMSȱphoneȱno.ȱYȱ
CommunicationȱfailȱtroubleȱrestoreȱtoȱMSȱphoneȱno.ȱYȱ
TamperȱalarmȱfromȱtheȱListenȱInȱmessageȱboxȱunitȱ
TamperȱalarmȱrestoreȱfromȱtheȱListenȱInȱmessageȱboxȱunitȱ
CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱIPȱcardȱ
CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱI/Oȱmoduleȱ
CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱsirenȱYȱ
NoȱcommunicationȱbetweenȱtheȱGSM/GPRSȱModuleȱandȱtheȱAgilityȱ
IfȱtheȱphoneȱlineȱisȱcutȱorȱtheȱDCȱlevelȱisȱunderȱ1Vȱ
Phoneȱlineȱtroubleȱrestoreȱ
Policeȱ(panic)ȱalarmȱfromȱwirelessȱkeypadȱYȱȱ
Policeȱ(panic)ȱalarmȱfromȱremoteȱcontrolȱYYȱ
LoadȱnewȱparametersȱintoȱtheȱAgilityȱfromȱPTMȱaccessoryȱȱ
RadioȱlowȱbatteryȱtroubleȱfromȱsirenȱYȱ
RadioȱlowȱbatteryȱrestoreȱfromȱsirenȱYȱ
Theȱsystemȱhasȱbeenȱarmedȱfromȱtheȱconfigurationȱsoftwareȱ
Theȱsystemȱhasȱbeenȱprogrammedȱfromȱtheȱconfigurationȱsoftwareȱ
TheȱsystemȱhasȱbeenȱarmedȱinȱSTAYȱmodeȱfromȱtheȱconfigurationȱ
softwareȱ
Alarmȱrestoreȱinȱzoneȱno.ȱXXȱ
Wirelessȱreceiverȱjammingȱ
PartitionȱYȱdisarmedȱfromȱtheȱconfigurationȱsoftwareȱ
SirenȱYȱisȱregardedȱasȱlostȱfollowingȱsupervisionȱtestȱ
TheȱAgilityȱreceivedȱaȱsignalȱfromȱsirenȱYȱafterȱitȱhasȱbeenȱregardedȱ
asȱlostȱ
ZoneȱXXȱhasȱfailedȱinȱtheȱsoakȱtestȱ
SpecialȱalarmȱfromȱtheȱfromȱwirelessȱkeypadȱYȱȱ
ȱSpeakerȱlowȱbatteryȱrestoreȱfromȱsirenȱYȱ
SpeakerȱlowȱbatteryȱtroubleȱfromȱsirenȱYȱ
ExitȱtimeȱstartedȱinȱpartitionȱYȱ
PartitionȱYȱstayȱarmedȱbyȱuserȱZZȱ
PartitionȱYȱstayȱarmedȱbyȱremoteȱcontrolȱZZȱ
TamperȱalarmȱfromȱI/Oȱmoduleȱ
TamperȱalarmȱrestoredȱfromȱI/Oȱmoduleȱ
TamperȱKeypad=yȱȱ
TamperȱrsȱZn=xxȱȱ
TamperȱrstȱKP=yȱȱ
TamperȱSiren=yȱȱȱ
TamperȱalarmȱfromȱkeypadȱID=Yȱ
Tamperȱalarmȱrestoreȱonȱzoneȱno.ȱXXȱ
KeypadȱYȱtamperȱrestoreȱ
TamperȱalarmȱfromȱwirelessȱsirenȱYȱ
RestoreȱZone=xxȱȱ
RFȱJammingȱȱȱȱȱȱȱ
Rmtȱdisarm:P=yȱȱȱ
Siren=yȱLostȱȱȱȱȱ
Siren=yȱLostȱRstȱ
Page 43
ȱ
EventȱMessageȱ
TamperȱZone=xxȱȱȱ
TechȱalarmȱZn=xxȱ
TechȱrstrȱȱZn=xxȱ
TmpȱrstrȱSiren=yȱ
UnbypȱBox+Bellȱȱȱ
UnbypassȱZone=xxȱ
Unknownȱeventȱȱȱȱ
UserȱloginȱC=xxȱȱ
WaterȱAlrmȱZn=xxȱ
WaterȱrstrȱZn=xxȱ
Z=xxȱautoȱbadȱȱȱȱ
Z=xxȱautoȱokȱȱȱȱȱ
Zn=xxȱTroubleȱ
Zn=xxȱTroubleȱOKȱ
AgilityȱUserȱManualȱ
Descriptionȱ
Tamperȱalarmȱfromȱzoneȱno.ȱXXȱ
AlarmȱfromȱzoneȱXXȱdefinedȱasȱTechnicalȱ
AlarmȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱTechnicalȱ
TamperȱalarmȱrestoreȱfromȱwirelessȱsirenȱYȱ
Boxȱ+ȱBellȱreinstatedȱfromȱbypassȱ
Zoneȱno.ȱXXȱisȱreinstatedȱfromȱbypassȱ
Unknownȱeventȱalertȱ
UserȱXXȱhasȱenteredȱintoȱprogrammingȱmode.ȱUserȱ99ȱrepresentsȱ
remoteȱprogrammingȱfromȱtheȱconfigurationȱsoftwareȱ
Floodȱalarmȱfromȱzoneȱno.ȱXXȱ
Floodȱalarmȱrestoreȱonȱzoneȱno.ȱXXȱ
ZoneȱselfȬtestȱfailed,ȱzoneȱno.ȱXXȱ
ZoneȱselfȬtestȱOK,ȱzoneȱno.ȱXXȱ
ZoneȱtroubleȱeventȱfromȱzoneȱXXȱ
ZoneȱtroubleȱeventȱrestoreȱfromȱzoneȱXXȱ
ȱ
Page 44
AgilityȱUserȱManualȱ
ȱ
Notes
ȱ
AgilityȱUserȱManualȱ
Notes
ȱ
ȱ
FCCȱNote:ȱ
ThisȱequipmentȱhasȱbeenȱtestedȱandȱfoundȱtoȱcomplyȱwithȱtheȱlimitsȱforȱaȱClassȱBȱ
digitalȱdevice,ȱpursuantȱtoȱPartȱ15ȱofȱtheȱFCCȱrules.ȱȱTheseȱlimitsȱareȱdesignedȱtoȱ
provideȱreasonableȱprotectionȱagainstȱharmfulȱinterferenceȱinȱaȱresidentialȱinstallation.ȱȱ
Thisȱequipmentȱgenerates,ȱusesȱandȱcanȱradiateȱradioȱfrequencyȱenergyȱand,ȱifȱnotȱ
installedȱandȱusedȱinȱaccordanceȱwithȱtheȱinstructions,ȱmayȱcauseȱharmfulȱinterferenceȱ
toȱradioȱcommunications.ȱȱHowever,ȱthereȱisȱnoȱguaranteeȱthatȱinterferenceȱwillȱnotȱ
occurȱinȱaȱparticularȱinstallation.ȱȱIfȱthisȱequipmentȱdoesȱcauseȱharmfulȱinterferenceȱtoȱ
radioȱorȱtelevisionȱreception,ȱwhichȱcanȱbeȱdeterminedȱbyȱturningȱtheȱequipmentȱoffȱ
andȱon,ȱtheȱuserȱisȱencouragedȱtoȱtryȱtoȱcorrectȱtheȱinterferenceȱbyȱoneȱorȱmoreȱofȱtheȱ
followingȱmeasures:ȱ
a)ȱȱReorientȱorȱrelocateȱtheȱreceivingȱantenna.ȱ
b)ȱȱIncreaseȱtheȱseparationȱbetweenȱtheȱequipmentȱandȱreceiver.ȱ
c)ȱȱConnectȱtheȱequipmentȱtoȱanȱoutletȱonȱaȱcircuitȱdifferentȱfromȱthatȱtoȱ
whichȱtheȱreceiverȱisȱconnected.ȱ
d)ȱConsultȱtheȱdealerȱorȱanȱexperiencedȱradio/TVȱtechnician.ȱ
ȱ
FCCȱWarning:ȱ
TheȱmanufacturerȱisȱnotȱresponsibleȱforȱanyȱradioȱorȱTVȱinterferenceȱcausedȱbyȱ
unauthorizedȱmodificationsȱtoȱthisȱequipment.ȱSuchȱmodificationsȱcouldȱvoidȱtheȱuserȇsȱ
authorityȱtoȱoperateȱtheȱequipment.ȱ
ȱ
FCCȱID:ȱJE4AGILITYȱValidȱforȱP/NȱRW132V441ENAȱ
IC:ȱ6564AȬAGILITYȱValidȱforȱP/NȱRW132V441ENAȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
RISCO Group Limited Warranty
RISCOȱGroupȱandȱitsȱsubsidiariesȱandȱaffiliatesȱ(ȈSellerȈ)ȱwarrantsȱitsȱproductsȱtoȱbeȱfreeȱ
fromȱdefectsȱinȱmaterialsȱandȱworkmanshipȱunderȱnormalȱuseȱforȱ24ȱmonthsȱfromȱtheȱdateȱ
ofȱproduction.ȱBecauseȱSellerȱdoesȱnotȱinstallȱorȱconnectȱtheȱproductȱandȱbecauseȱtheȱ
productȱmayȱbeȱusedȱinȱconjunctionȱwithȱproductsȱnotȱmanufacturedȱbyȱtheȱSeller,ȱSellerȱ
cannotȱguaranteeȱtheȱperformanceȱofȱtheȱsecurityȱsystemȱwhichȱusesȱthisȱproduct.ȱSellerȇsȱ
obligationȱandȱliabilityȱunderȱthisȱwarrantyȱisȱexpresslyȱlimitedȱtoȱrepairingȱandȱreplacing,ȱ
atȱSellerȇsȱoption,ȱwithinȱaȱreasonableȱtimeȱafterȱtheȱdateȱofȱdelivery,ȱanyȱproductȱnotȱ
meetingȱtheȱspecifications.ȱSellerȱmakesȱnoȱotherȱwarranty,ȱexpressedȱorȱimplied,ȱandȱ
makesȱnoȱwarrantyȱofȱmerchantabilityȱorȱofȱfitnessȱforȱanyȱparticularȱpurpose.ȱ
Inȱnoȱcaseȱshallȱsellerȱbeȱliableȱforȱanyȱconsequentialȱorȱincidentalȱdamagesȱforȱbreachȱofȱ
thisȱorȱanyȱotherȱwarranty,ȱexpressedȱorȱimplied,ȱorȱuponȱanyȱotherȱbasisȱofȱliabilityȱ
whatsoever.ȱ
Sellerȇsȱobligationȱunderȱthisȱwarrantyȱshallȱnotȱincludeȱanyȱtransportationȱchargesȱorȱcostsȱ
ofȱinstallationȱorȱanyȱliabilityȱforȱdirect,ȱindirect,ȱorȱconsequentialȱdamagesȱorȱdelay.ȱ
Sellerȱdoesȱnotȱrepresentȱthatȱitsȱproductȱmayȱnotȱbeȱcompromisedȱorȱcircumvented;ȱthatȱ
theȱproductȱwillȱpreventȱanyȱpersonalȱinjuryȱorȱpropertyȱlossȱbyȱburglary,ȱrobbery,ȱfireȱorȱ
otherwise;ȱorȱthatȱtheȱproductȱwillȱinȱallȱcasesȱprovideȱadequateȱwarningȱorȱprotection.ȱ
Buyerȱunderstandsȱthatȱaȱproperlyȱinstalledȱandȱmaintainedȱalarmȱmayȱonlyȱreduceȱtheȱriskȱ
ofȱburglary,ȱrobberyȱorȱfireȱwithoutȱwarning,ȱbutȱisȱnotȱinsuranceȱorȱaȱguarantyȱthatȱsuchȱ
eventȱwillȱnotȱoccurȱorȱthatȱthereȱwillȱbeȱnoȱpersonalȱinjuryȱorȱpropertyȱlossȱasȱaȱresultȱ
thereof.ȱ
Consequentlyȱsellerȱshallȱhaveȱnoȱliabilityȱforȱanyȱpersonalȱinjury,ȱpropertyȱdamageȱorȱlossȱ
basedȱonȱaȱclaimȱthatȱtheȱproductȱfailsȱtoȱgiveȱwarning.ȱHowever,ȱifȱsellerȱisȱheldȱliable,ȱ
whetherȱdirectlyȱorȱindirectly,ȱforȱanyȱlossȱorȱdamageȱarisingȱunderȱthisȱlimitedȱwarrantyȱorȱ
otherwise,ȱregardlessȱofȱcauseȱorȱorigin,ȱsellerȇsȱmaximumȱliabilityȱshallȱnotȱexceedȱtheȱ
purchaseȱpriceȱofȱtheȱproduct,ȱwhichȱshallȱbeȱcompleteȱandȱexclusiveȱremedyȱagainstȱseller.ȱ
NoȱemployeeȱorȱrepresentativeȱofȱSellerȱisȱauthorizedȱtoȱchangeȱthisȱwarrantyȱinȱanyȱwayȱ
orȱgrantȱanyȱotherȱwarranty.ȱ
WARNING:ȱThisȱproductȱshouldȱbeȱtestedȱatȱleastȱonceȱaȱweek.ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
ȱ
©ȱRISCOȱGroupȱȱȱ03/10ȱ
ȱȱ
ȱ
ȱ
ȱ
ȱ
Sounders
Security Devices
Wireless
WatchOUT
IP
Cameras
iWAVE
PIR/PET
Detectors
Monitoring Station
Glassbreak
Detectors
Fully Wireless
Internal & External
Sounders
Universal
Shock
Transmitters/ Detectors
Magnetic
Contacts
GSM/GPRS
Main Panel
Remote
Configuration
Software
Safety Devices
Video
Verification
IP/GSM
Receiver
Software
User Monitoring
Smoke
Detectors
Flood
Detectors
Gas
Detectors
CO
Detectors
IP/Internet
Keypads, Keyfobs, Panic
2-Way
Remote
Control
Button
Keyfobs
Wristband
Panic
Transmitter
Web Browser
Management
Home Automation
Voice
Messages
Email
Notification
PSTN/Dial-Up
Input/Output & X10
Expander module
5IN1041 E
2-Way Wireless
Keypads
with proximity
tags
Video
SMS
VerificationMessaging
© 03/2010 RISCO Group
All rights reserved. No part of this document may