Download Agility 2 Full User Manual
Transcript
Agility TM Flexible Wireless Solution User Manual ȱ ȱ User Manual ȱ ȱ ȱ ȱ ȱ ȱ ȱ AgilityȱUserȱManualȱ Important Notice Thisȱguideȱisȱdeliveredȱsubjectȱtoȱtheȱfollowingȱconditionsȱandȱrestrictions:ȱ ThisȱguideȱcontainsȱproprietaryȱinformationȱbelongingȱtoȱRISCOȱGroup.ȱSuchȱ informationȱisȱsuppliedȱsolelyȱforȱtheȱpurposeȱofȱassistingȱexplicitlyȱandȱproperlyȱ authorizedȱusersȱofȱtheȱsystem.ȱ Noȱpartȱofȱitsȱcontentsȱmayȱbeȱusedȱforȱanyȱotherȱpurpose,ȱdisclosedȱtoȱanyȱpersonȱ orȱfirm,ȱorȱreproducedȱbyȱanyȱmeans,ȱelectronicȱorȱmechanical,ȱwithoutȱtheȱexpressȱ priorȱwrittenȱpermissionȱofȱRISCOȱGroup.ȱ Theȱinformationȱcontainedȱhereinȱisȱforȱtheȱpurposeȱofȱillustrationȱandȱreferenceȱ only.ȱ Informationȱinȱthisȱdocumentȱisȱsubjectȱtoȱchangeȱwithoutȱnotice.ȱ Corporateȱandȱindividualȱnamesȱandȱdataȱusedȱinȱexamplesȱhereinȱbelongȱtoȱtheirȱ respectiveȱowners.ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ Allȱrightsȱreserved.ȱȱ ȱ2010ȱRISCOȱGroupȱ ȱ Marchȱ2010ȱ Page 2 AgilityȱUserȱManualȱ ȱ Table of Contents Chapterȱ1ȱȬȱIntroduction.............................................................................................................................5ȱ 1.1ȱMainȱFeatures .....................................................................................................................................5ȱ 1.2ȱAgilityȱArchitecture...........................................................................................................................6ȱ 1.3ȱUserȱOperatingȱTools ........................................................................................................................7ȱ 1.4ȱStatusȱIndications...............................................................................................................................8ȱ LEDȱIndicators................................................................................................................................8ȱ StatusȱButtonȱ/ȱServiceȱCallȱ(Listenȱ&ȱTalk)...............................................................................9ȱ VoiceȱMessaging.............................................................................................................................9ȱ SMSȱMessaging...............................................................................................................................9ȱ EmailȱMessaging ............................................................................................................................9ȱ SoundȱIndications ........................................................................................................................10ȱ Chapterȱ2ȱȬȱLocalȱSystemȱOperation......................................................................................................11ȱ 2.1ȱArmingȱyourȱsystem .......................................................................................................................11ȱ Awayȱ(Full)ȱarming..................................................................................................................11ȱ Stayȱ(Home)ȱarming.................................................................................................................12ȱ Partitionȱarming .......................................................................................................................12ȱ ForceȱArming ............................................................................................................................13ȱ ArmingȱwithȱtroublesȱinȱtheȱSystem .....................................................................................13ȱ 2.2ȱDisarmingȱyourȱsystem...................................................................................................................14ȱ Systemȱdisarming.....................................................................................................................14ȱ Partitionȱdisarming ..................................................................................................................15ȱ Duressȱdisarming .....................................................................................................................15ȱ DisarmingȱafterȱanȱAlarm .......................................................................................................15ȱ Resettingȱafterȱanȱalarm ..........................................................................................................16ȱ AntiȱCodeȱReset ...................................................................................................................16ȱ InstallerȱReset .......................................................................................................................16ȱ 2.3ȱSendingȱaȱPanicȱAlarm....................................................................................................................17ȱ Chapterȱ3ȱȬȱRemoteȱSystemȱOperation..................................................................................................18ȱ 3.1ȱRemoteȱPhoneȱOperation ...............................................................................................................18ȱ RemotelyȱAccessingȱtheȱSystem ................................................................................................18ȱ VoiceȱOperationsȱMenu ..............................................................................................................18ȱ ReceivingȱCallsȱfromȱtheȱSystem ...............................................................................................19ȱ AcknowledgeȱMenu ....................................................................................................................20ȱ BiȬdirectionalȱCommunication...................................................................................................20ȱ 3.2ȱSMSȱOperation .................................................................................................................................21ȱ SMSȱRemoteȱControl ...................................................................................................................21ȱ SMSȱConfirmationȱMessage .......................................................................................................22ȱ Chapterȱ4ȱȬȱUserȱFunctionsȱandȱSettings ..............................................................................................23ȱ 4.1ȱUserȱCodes ........................................................................................................................................23ȱ 4.2ȱProximityȱTags .................................................................................................................................25ȱ 4.3ȱDefiningȱFollowȱMeȱDestinations .................................................................................................26ȱ 4.4ȱScheduler...........................................................................................................................................27ȱ 4.5ȱMacroȱkeys ........................................................................................................................................28ȱ 4.6ȱCompleteȱMenuȱofȱUserȱFunctions ...............................................................................................30ȱ Page 3 ȱ AgilityȱUserȱManualȱ Chapterȱ5ȱȬȱSystemȱSpecifications .........................................................................................................33ȱ Chapterȱ6ȱȬȱENȱ50131ȱCompliance..........................................................................................................34ȱ AppendixȱAȱȬȱKeypadȱUserȱOperations................................................................................................35ȱ CommonȱOperations .............................................................................................................................35ȱ AdvancedȱOperations ...........................................................................................................................35ȱ LEDsȱIndication......................................................................................................................................37ȱ AppendixȱBȱȬȱRemoteȱControlȱUserȱOperations .................................................................................38ȱ CommonȱOperations .............................................................................................................................38ȱ AdvancedȱOperations ...........................................................................................................................38ȱ StatusȱLED/BuzzerȱIndications............................................................................................................39ȱ ChangingȱRemoteȱControlȱPINȱCode .................................................................................................39ȱ AppendixȱCȱȬȱEventȱLogȱMessages ........................................................................................................40ȱ Page 4 AgilityȱUserȱManualȱ ȱ Chapter 1 - Introduction CongratulationsȱonȱyourȱpurchaseȱofȱAgilityȱȬȱRISCOȱGroupȇsȱFlexibleȱWirelessȱSecurityȱ System.ȱTheȱAgilityȱhasȱbeenȱspecificallyȱdesignedȱtoȱmeetȱaȱwideȱrangeȱofȱsecurity,ȱsafetyȱ andȱhomeȱautomationȱneedsȱforȱmanyȱresidentialȱandȱcommercialȱapplications.ȱ Agilityȱisȱdesignedȱtoȱrecognizeȱabnormalȱconditionsȱandȱinformȱtheȱsystemȱofȱtheȱstatusȱ ofȱanyȱprotectedȱdoor,ȱwindow,ȱhallway,ȱroom,ȱorȱarea.ȱStatusȱinformationȱisȱpresentedȱ visuallyȱorȱverbally.ȱItȱsupportsȱtheȱcapabilitiesȱofȱcommunicatingȱwithȱaȱCentralȱ MonitoringȱStationȱorȱtoȱyourȱmobileȱphoneȱusingȱfriendlyȱandȱeasyȱtoȱunderstandȱverbalȱ messagesȱasȱwellȱasȱSMSȱorȱEȬmailȱmessages.ȱ Thisȱmanualȱdescribesȱhowȱtoȱoperateȱyourȱsystem.ȱItȱwillȱguideȱyouȱthroughȱ programmingȱinstructionsȱforȱmainȱsystemȱfeaturesȱasȱwellȱasȱbasicȱarmingȱandȱdisarmingȱ commandsȱforȱtheȱsystem.ȱ 1.1 Main Features Upȱtoȱ32ȱwirelessȱzonesȱ(1ȱwayȱorȱ2ȱwayȱ wirelessȱdetectors)ȱ+ȱ4ȱoptionalȱwiredȱ zonesȱ(onlyȱwithȱI/Oȱexpander)ȱ 32ȱUserȱcodesȱ+ȱGrandȱMasterȱcodeȱȱ 4ȱfixedȱauthorityȱlevelsȱforȱuserȱȱȱ Proximityȱtagȱforȱeachȱuserȱȱ 3ȱpartitionsȱ 3ȱwirelessȱkeypadsȱ(1ȱwayȱorȱ2ȱway)ȱȱ 3ȱwirelessȱsirensȱ(internalȱorȱexternal)ȱȱ 8ȱRemoteȱcontrolsȱ(1ȱwayȱorȱ2ȱway)ȱȱ 250ȱEventsȱLogȱȱ 16ȱFollowȱMeȱdestinationsȱȱȱ 4ȱoutputsȱ(I/Oȱexpander)ȱ XȬ10ȱsupportȱȱ Page 5 ȱ ȱ AgilityȱUserȱManualȱ 1.2 Agility Architecture YourȱAgilityȱcontrolsȱandȱmonitorsȱaȱvarietyȱofȱsensors,ȱdetectors,ȱandȱcontactsȱplacedȱ throughoutȱtheȱpremises,ȱwhichȱprovideȱexternal,ȱperimeterȱandȱinternalȱburglaryȱ protection.ȱTheȱsystemȱisȱsupervised,ȱmeaningȱthatȱtheȱpanelȱchecksȱtheȱstatusȱofȱeachȱ sensorȱtoȱdetectȱproblems.ȱIfȱtheȱpanelȱdetectsȱtroubleȱitȱwillȱnotifyȱyouȱwithȱbeepsȱandȱ indicatorȱlightsȱonȱtheȱpanelȱitself.ȱȱ Theȱfollowingȱdiagramȱshowsȱtheȱcomponentsȱthatȱmakeȱupȱtheȱsystem:ȱ ȱ ȱ ȱ ȱ ȱ ȱ Page 6 AgilityȱUserȱManualȱ ȱ 1.3 User Operating Tools TheȱAgilityȱsystemȱcanȱbeȱoperatedȱusingȱseveralȱdevices,ȱsomeȱofȱwhichȱhaveȱbeenȱ designedȱasȱbiȬdirectional.ȱIfȱyouȱhaveȱpurchasedȱaȱbiȬdirectionalȱdeviceȱyourȱsystemȱisȱ capableȱofȱsendingȱaȱreturnȱreplyȱstatusȱindicationȱfromȱtheȱpanelȱtoȱtheȱdeviceȱforȱeachȱ commandȱthatȱisȱsentȱtoȱit.ȱ Dependingȱonȱyourȱpurchaseȱyouȱcanȱoperateȱyourȱsystemȱviaȱtheȱfollowing:ȱȱ 2ȬWayȱ8ȱButtonȱRemoteȱControl:ȱȱ UsingȱtheȱbiȬdirectionalȱ8ȱbuttonȱremoteȱcontrolȱyouȱcanȱarm,ȱdisarm,ȱ sendȱaȱpanicȱalarm,ȱactivateȱoutputsȱandȱmore.ȱBeingȱbiȬdirectionalȱ theȱremoteȱcontrolȱreceivesȱaȱreplyȱstatusȱindication,ȱviaȱitsȱ3ȱcoloredȱ LEDsȱandȱinternalȱbuzzerȱsiren,ȱfromȱtheȱpanelȱforȱeachȱcommandȱ thatȱitȱhasȱsentȱtoȱtheȱpanel.ȱForȱhigherȱsecurity,ȱcommandsȱcanȱbeȱ definedȱtoȱbeȱactivatedȱwithȱaȱ4ȱdigitȱPINȱcode.ȱ ȱ Agilityȱ2ȬWayȱWirelessȱKeypad:ȱ ȱ UsingȱtheȱbiȬdirectionalȱwirelessȱkeypadȱyouȱcanȱprogramȱandȱ operateȱyourȱsystemȱaccordingȱtoȱyourȱneeds.ȱBeingȱbiȬdirectionalȱtheȱ keypadȱreceivesȱaȱreplyȱstatusȱindicationȱfromȱtheȱpanelȱforȱeachȱ commandȱthatȱitȱhasȱsentȱtoȱtheȱpanel.ȱȱToȱuseȱfunctionsȱofȱtheȱ keypadȱyouȱcanȱuseȱaȱcodeȱorȱaȱproximityȱtag.ȱ 4ȱButtonȱKeyȱfob:ȱ Usingȱtheȱ4ȱbuttonȱkeyȱfobȱyouȱcanȱarm,ȱdisarm,ȱsendȱaȱpanicȱalarmȱ andȱactivateȱoutputs.ȱ ȱ RemoteȱPhoneȱOperation:ȱȱ ȱ Usingȱanyȱremote,ȱtouchȬtoneȱphoneȱyouȱcanȱperformȱremoteȱ operationsȱsuchȱasȱarming,ȱdisarming,ȱlisteningȱinȱandȱtalkingȱtoȱtheȱ premisesȱandȱmore.ȱTheȱsystemȱcanȱalsoȱprovideȱaudibleȱinformationȱ suchȱasȱeventȱoccurrencesȱandȱtheȱstatusȱofȱyourȱsystem.ȱ ȱ IfȱyourȱsystemȱisȱequippedȱwithȱaȱGSM/GPRSȱmoduleȱitȱcanȱprovideȱ informationȱaboutȱtheȱsystemȱsuchȱasȱeventȱoccurrencesȱbyȱSMS.ȱYouȱ canȱalsoȱoperateȱtheȱsystemȱusingȱSMSȱcommandsȱforȱarmingȱandȱ disarmingȱtheȱsystemȱandȱmore.ȱ SMS:ȱȱ ConfigurationȱSoftware:ȱȱ ȱ RISCOȱGroupȇsȱConfigurationȱSoftwareȱenablesȱtheȱinstallerȱtoȱ programȱtheȱsystemȱandȱoperateȱtheȱsystemȱlocallyȱorȱremotely.ȱ WebȱBrowser:ȱȱ ȱ Usingȱtheȱwebȱyouȱcanȱperformȱaȱvarietyȱofȱoperationsȱonȱyourȱ systemȱsuchȱasȱarming,ȱdisarming,ȱoutputȱactivation,ȱreceiveȱstatusȱ informationȱandȱviewingȱeventȱlogs.ȱThisȱfeatureȱwillȱbeȱavailableȱinȱ futureȱversionsȱofȱAgility.ȱ Page 7 ȱ AgilityȱUserȱManualȱ 1.4 Status Indications LED Indicators TheȱLEDȱindicatorsȱprovideȱtypicalȱsystemȱindications,ȱasȱdiscussedȱbelow.ȱSomeȱ indicatorsȱhaveȱadditionalȱfunctions,ȱwhichȱareȱexplainedȱlaterȱon.ȱ Power LED (Green) TheȱPowerȱLEDȱindicatesȱsystemȱoperation.ȱ Condition Description Onȱ Rapidȱflashȱ Slowȱflashȱ PowerȱOKȱ IndicatesȱACȱtroubleȱ Indicatesȱlowȱbatteryȱtroubleȱ Arm/Alarm LED (Red) Condition Description Onȱ Rapidȱflashȱ Slowȱflashȱ Systemȱarmedȱ Alarmȱ SystemȱinȱExitȱdelayȱ Stay LED (Red) Condition Description Onȱ Offȱ SystemȱarmedȱatȱSTAYȱ Systemȱdisarmedȱȱ Ready LED (Green) Condition Description Onȱ Offȱ SlowȱFlashȱ Systemȱreadyȱ Openȱzonesȱȱ Systemȱisȱreadyȱtoȱbeȱarmedȱwhileȱaȱspeciallyȱ designatedȱentry/exitȱdoorȱremainsȱopenȱ Trouble LED (Orange) Condition Description RapidȱFlashȱ Offȱ Troubleȱ Noȱtroubleȱȱ Note:ȱWhenȱallȱLEDsȱflashȱoneȱafterȱanotherȱinȱsequenceȱtheȱsystemȱisȱinȱInstallationȱmode. Page 8 AgilityȱUserȱManualȱ ȱ Status Button / Service Call (Listen & Talk) TheȱbuttonȱonȱtheȱmainȱunitȱcanȱbeȱdefinedȱasȱaȱsystemȱstatusȱindicatorȱorȱasȱaȱS.O.Sȱ button.ȱOnceȱpressed,ȱaȱserviceȱcallȱwillȱbeȱestablishedȱtoȱtheȱmonitoringȱstation,ȱ whichȱthenȱenablesȱ2Ȭwayȱcommunicationȱwithȱtheȱpremises.ȱȱȱ Voice Messaging ThreeȱtypesȱofȱspokenȱmessagesȱareȱheardȱwhenȱusingȱtheȱAgility,ȱlocallyȱinȱtheȱpremisesȱ orȱremotelyȱtoȱyourȱmobile:ȱ Eventȱmessages:ȱUponȱselectedȱeventȱoccurrence,ȱtheȱAgilityȱinitiatesȱaȱcallȱtoȱaȱ remoteȱFollowȱMeȱ(FM)ȱtelephoneȱnumber,ȱinformingȱyouȱofȱaȱsecurityȱsituationȱbyȱ playingȱaȱpreȬrecordedȱEventȱannouncementȱmessage.ȱ Statusȱmessages:ȱUponȱremoteȱaccessȱofȱtheȱsystemȱbyȱinitiatingȱaȱcallȱfromȱaȱ remoteȱtelephoneȱorȱreceivingȱaȱcallȱfromȱtheȱsystem,ȱtheȱAgilityȱannouncesȱtheȱ currentȱsystemȱstatusȱbyȱplayingȱaȱpreȬrecordedȱStatusȱmessage.ȱȱ LocalȱAnnouncementȱmessages:ȱUponȱeventȱoccurrenceȱorȱuser’sȱkeypadȱ operations,ȱtheȱAgilityȱcanȱannounceȱvariousȱlocalȱmessagesȱtoȱresidents.ȱȱ SMS Messaging UsingȱtheȱGSM/GPRSȱModuleȱtheȱsystemȱcanȱsendȱpredefinedȱSMSȱeventȱmessagesȱtoȱaȱ remoteȱFollowȱMeȱ(FM)ȱtelephoneȱnumber,ȱinformingȱyouȱofȱtheȱstatusȱofȱtheȱsecurityȱ systemȱandȱcertainȱeventsȱthatȱoccurredȱinȱtheȱsystem.ȱ Forȱexample:ȱȱ ȱ Email Messaging UsingȱtheȱAgilityȱIPȱModuleȱtheȱsystemȱcanȱsendȱeventȱmessagesȱbyȱEmailȱtoȱpredefinedȱeȬ mailȱaddressesȱinformingȱyouȱofȱtheȱstatusȱofȱtheȱsecurityȱsystemȱandȱcertainȱeventsȱthatȱ occurredȱinȱtheȱsystem.ȱ Forȱexample:ȱȱ Subject:ȱȱAlarmȱSecurityȱMessage:ȱIntruderȱAlarmȱȱ SystemȱName:ȱJohnȇsȱResidenceȱ Event:ȱFireȱAlarm,ȱZoneȱ5,ȱEntranceȱdoorȱȱȱ Time:ȱ01ȱAprilȱ2008;ȱ16:12ȱ Partition:ȱPartitionȱ1,ȱFirstȱfloorȱȱȱȱȱȱ ServiceȱContact:ȱMonitoringȱStationȱ01,ȱ03Ȭ5676778ȱ ȱ Page 9 ȱ AgilityȱUserȱManualȱ Sound Indications InȱadditionȱtoȱtheȱvisualȱindicationsȱprovidedȱbyȱtheȱAgility’sȱLEDs,ȱyourȱsystemȱproducesȱ audibleȱnotificationȱafterȱcertainȱevents.ȱ Condition Description Intrusionȱalarmȱ Fireȱalarmȱ Exitȱdelayȱ Entryȱdelayȱ Confirmȱoperationȱ Rejectȱoperationȱ Arm/Disarmȱsquawkȱ Continuesȱrapidȱbeepingȱ Staggeredȱrapidȱbeepingȱ SlowȱbuzzerȱbeepsȱuntilȱtheȱExitȱDelayȱtimeȱperiodȱexpiresȱ SlowȱbuzzerȱbeepsȱuntilȱtheȱEntryȱDelayȱtimeȱperiodȱexpires.ȱȱ AȱoneȬsecondȱtoneȱ Threeȱrapidȱerrorȱbeepsȱ 1ȱsirenȱchirp:ȱSystemȱarmedȱ 2ȱsirenȱchirps:ȱSystemȱisȱdisarmedȱ 4ȱsirenȱchirps:ȱSystemȱdisarmedȱafterȱanȱalarmȱ ȱ ȱ Page 10 AgilityȱUserȱManualȱ ȱ Chapter 2 - Local System Operation 2.1 Arming your system Armingȱyourȱsystemȱcausesȱtheȱintrusionȱdetectorsȱtoȱtriggerȱanȱalarmȱwhenȱviolated.ȱTheȱ armingȱoperationȱwillȱbeȱfollowedȱbyȱaȱlocalȱmessageȱannouncementȱ(ifȱdefined).ȱȱ Beforeȱarmingȱtheȱsystemȱcheckȱtheȱ ȱReadyȱLEDȱandȱmakeȱsureȱthatȱtheȱsystemȱisȱreadyȱ toȱbeȱarmed.ȱIfȱtheȱsystemȱisȱNOTȱreadyȱtoȱbeȱarmedȱsecureȱorȱbypassȱtheȱviolatedȱzone(s),ȱ andȱthenȱproceed.ȱ Failingȱtoȱarmȱtheȱsystemȱwillȱbeȱindicatedȱbyȱtheȱsystemȱ YourȱAgilityȱoffersȱtheȱfollowingȱkindsȱofȱarming:ȱȱ Note:ȱIfȱyouȱareȱunableȱtoȱarmȱtheȱsystem,ȱpressȱtheȱstatusȱkeyȱtoȱviewȱsystemȱmessages.ȱ Awayȱ(Full)ȱarming:ȱȱ Awayȱarmingȱpreparesȱallȱofȱtheȱsystemȇsȱintrusionȱdetectorsȱtoȱactivateȱanȱalarmȱifȱ violated,ȱandȱisȱusedȱwhenȱleavingȱtheȱpremises.ȱTheȱsystemȱwillȱarmȱafterȱtheȱ designatedȱcountdownȱtimeȱ(Exitȱdelay)ȱandȱaȱlocalȱmessageȱwillȱsound.ȱOnceȱyouȱhaveȱ armedȱtheȱsystem,ȱexitȱviaȱtheȱdesignatedȱfinalȱexitȱdoor.ȱ Toȱarmȱusing Awayȱ(Full)ȱarming procedure Quickȱmode:ȱ ȱ ȱ Highȱsecurityȱmode:ȱPressȱ Quickȱmode:ȱ ȱ ȱ+ȱcodeȱ ȱȱ Highȱsecurityȱmode:ȱ ȱ+ȱcodeȱorȱproximityȱtagȱȱȱ Press±ȱ SendȱSMSȱ:ȱ[Code][A],ȱexample,ȱ1234Aȱ ȱ ȱ ȱ ȱ ȱ ȱ Page 11 ȱ AgilityȱUserȱManualȱ Stayȱ(Home)ȱarming:ȱȱȱ Stayȱarmingȱactivatesȱonlyȱperimeterȱdetectorsȱ(asȱdefinedȱbyȱyourȱinstaller),ȱenablingȱ individualsȱtoȱremainȱinsideȱandȱmoveȱaboutȱtheȱpremisesȱwhileȱtheȱsystemȱisȱpartiallyȱ armed.ȱ Toȱarmȱusing Stayȱ(Home)ȱarming procedure ȱȱ Quickȱmode:ȱ Highȱsecurityȱmode:ȱ ȱ ȱȱ Quickȱmode:ȱ ȱ ȱ+ȱcodeȱ ȱ+ȱcodeȱorȱproximityȱtagȱȱȱ Highȱsecurityȱmode:ȱ Pressȱ±ȱbuttonȱorȱbuttonȱ4ȱ(ifȱdefined.ȱAdviseȱwithȱyourȱinstaller)ȱ SendȱSMSȱ:ȱ[Code][H],ȱexample,ȱ1234Hȱ ȱ Partitionȱarming:ȱȱ OneȱofȱtheȱAgilityȇsȱadvantagesȱisȱitsȱabilityȱtoȱdivideȱtheȱsystemȱinȱupȱtoȱ3ȱpartitions.ȱ Eachȱpartitionȱmayȱbeȱmanagedȱasȱaȱseparateȱsecurityȱsystem,ȱeachȱofȱwhichȱcanȱbeȱ armedȱandȱdisarmedȱindividuallyȱregardlessȱofȱtheȱconditionȱofȱtheȱother.ȱȱ Partitionsȱcanȱbeȱarmedȱorȱdisarmedȱoneȱatȱaȱtime,ȱorȱallȱatȱonce,ȱandȱeachȱpartitionȱcanȱ beȱarmedȱatȱStayȱorȱAway.ȱOnlyȱusersȱthatȱhaveȱbeenȱdefinedȱtoȱoperateȱmultipleȱ partitionsȱcanȱoperateȱmoreȱthanȱoneȱpartitionȱandȱarm/disarmȱallȱpartitionsȱatȱonceȱ Toȱarmȱusing Partitionȱarmingȱ(AwayȱorȱStay) procedure Quickȱmode:ȱ / / Highȱsecurityȱmode:ȱ ȱ Quickȱmode:ȱ ȱ / Highȱsecurityȱmode:ȱ / / > ȱ/ȱ / > > / / ȱ ȱ/ȱ ȱ/ȱ ȱȱ > ȱ/ȱ ȱ+ȱcodeȱ ȱ+ȱcodeȱorȱproximityȱtagȱȱȱ Pressȱ±ȱbuttonȱorȱbuttonȱ4ȱ(ifȱdefined.ȱAdviseȱwithȱyourȱinstaller)ȱ ȱ SendȱSMS:ȱȱ[Code][AȱorȱH]ȱ[Partitionȱ1,2ȱorȱ3].ȱExampleȱ1234A1.ȱForeȱmoreȱ informationȱreferȱtoȱpageȱ21.ȱ ȱ Page 12 AgilityȱUserȱManualȱ ȱ ForceȱArming:ȱ Forceȱarmingȱarmsȱtheȱsystemȱregardlessȱofȱopenȱzones.ȱYourȱinstallerȱmustȱenableȱthisȱ option.ȱȱ Note:ȱForceȱarmingȱtheȱsystemȱresultsȱinȱleavingȱpartȱofȱtheȱsystemȱunsecured.ȱ ȱ ArmingȱwithȱtroublesȱinȱtheȱSystemȱȱ Ifȱrequired,ȱandȱdefinedȱbyȱyourȱinstaller,ȱallȱtroublesȱinȱtheȱsystemȱshouldȱbeȱconfirmedȱ toȱenableȱtheȱarmingȱoperationȱwhileȱperformingȱarmingȱfromȱtheȱwirelessȱkeypad.ȱȱȱ Whenȱtryingȱtoȱarmȱtheȱsystemȱwithȱtroubles,ȱtheȱdisplayȱwillȱshowȱaȱȈSystemȱTroublesȈȱ ȱkeyȱtoȱviewȱtheȱtroublesȱinȱtheȱsystem.ȱScrollȱdownȱtheȱ message.ȱPressȱtheȱȱ troublesȱlistȱtoȱviewȱallȱtroublesȱinȱtheȱsystem.ȱ Toȱenableȱoneȱtimeȱarmingȱfromȱtheȱkeypad:ȱȱȱ ȱandȱenterȱyourȱuserȱcodeȱtoȱaccessȱtheȱuserȱmenu.ȱ 1. Pressȱ 2. GoȱtoȱActivitiesȱ>ȱBypassȱTroubleȱȱ 3. Theȱfollowingȱquestionȱwillȱappear:ȱȈBypassȱtroubles.ȱAreȱyouȱsure?ȱN?Ȉ.ȱUsingȱtheȱ ȱkeyȱchangeȱtoȱYȱandȱpressȱ 4. Pressȱ ȱtoȱconfirm.ȱ ȱtoȱreturnȱtoȱmainȱdisplayȱandȱperformȱtheȱarmingȱoperationȱagain.ȱȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ Page 13 ȱ AgilityȱUserȱManualȱ 2.2 Disarming your system Disarmingȱyourȱsystemȱcausesȱtheȱdetectorsȱnotȱtoȱtriggerȱanȱalarmȱwhenȱviolated.ȱWhenȱ youȱenterȱtheȱpremises,ȱtheȱEntryȱDelayȱbeginsȱtoȱcountȱdown.ȱYouȱmustȱdisarmȱtheȱ systemȱwithinȱtheȱEntryȱDelayȱtimeȱtoȱpreventȱtheȱsystemȱfromȱtriggeringȱanȱalarm.ȱTheȱ disarmingȱoperationȱwillȱbeȱfollowedȱbyȱaȱlocalȱmessageȱannouncementȱ(ifȱdefined).ȱȱ Note:ȱIfȱanȱalarmȱoccurredȱinȱtheȱsystem,ȱitȱisȱrecommendedȱtoȱleaveȱtheȱpremises.ȱOnlyȱafterȱpoliceȱ investigationȱshouldȱyouȱconsiderȱthatȱtheȱburglarȱisȱnoȱlongerȱonȱyourȱpremisesȱandȱyouȱcanȱreȬenter.ȱInȱ specialȱcasesȱ(ifȱprogrammedȱbyȱyourȱinstaller)ȱarmingȱtheȱsystemȱafterȱanȱalarmȱmightȱrequireȱaȱtechnicianȱ code.ȱForȱmoreȱinformationȱreferȱtoȱyourȱinstallerȱ YourȱAgilityȱoffersȱtheȱfollowingȱkindsȱofȱdisarming:ȱȱ ȱ Systemȱdisarming:ȱ Disarmingȱdeactivatesȱtheȱpartitionsȱassignedȱtoȱtheȱspecifiedȱuserȱcodeȱ Toȱdisarmȱusing ProcedureȱforȱDisarming Quickȱmode:ȱ disarmedȱ ȱ .ȱAllȱpartitionsȱassignedȱtoȱtheȱbuttonȱwillȱbeȱ Highȱsecurityȱmode:ȱȱ Pressȱ ȱ>ȱCodeȱ ȱfollowedȱbyȱcodeȱorȱproximityȱtag.ȱ ȱ ȱ Pressȱtheȱ²ȱbutton.ȱAllȱpartitionsȱassignedȱtoȱtheȱbuttonȱwillȱbeȱ disarmed.ȱȱ SendȱSMS:ȱȱ[Code][D],ȱexampleȱ1234Dȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ Page 14 AgilityȱUserȱManualȱ ȱ Partitionȱdisarming:ȱ Partitionȱdisarmingȱenablesȱyouȱtoȱdisarmȱindividualȱpartitionsȱwithinȱanȱarmedȱsystemȱ Toȱdisarmȱusing ProcedureȱforȱPartitionȱDisarming Quickȱmode:ȱ / / Highȱsecurityȱmode:ȱȱ ȱ / / > ȱȱȱ > / / > ȱ>ȱCodeȱ >ȱcodeȱorȱproximityȱtag.ȱ ȱ ȱ ȱ Pressȱtheȱ²ȱbutton.ȱAllȱpartitionsȱassignedȱtoȱtheȱbuttonȱwillȱbeȱ disarmed.ȱȱ SendȱSMS:ȱȱ[Code][D]ȱ[Partitionȱ1,2ȱorȱ3].ȱExampleȱ1234D1.ȱForeȱmoreȱ informationȱreferȱtoȱpageȱ21.ȱ ȱ Duressȱdisarming:ȱ Ifȱyouȱareȱeverȱcoercedȱintoȱdisarmingȱyourȱsystem,ȱyouȱcanȱcomplyȱwithȱtheȱintruderȇsȱ wishesȱwhileȱsendingȱaȱsilentȱduressȱalarmȱtoȱtheȱCentralȱStation.ȱToȱdoȱso,ȱyouȱmustȱ useȱaȱspecialȱduressȱcode,ȱwhichȱwhenȱused,ȱwillȱdisarmȱtheȱsystemȱinȱtheȱregularȱ manner,ȱwhileȱsimultaneouslyȱtransmittingȱtheȱduressȱalarm.ȱConferȱwithȱyourȱinstallerȱ whichȱofȱtheȱuserȇsȱcodesȱisȱdefinedȱasȱaȱduressȱcode.ȱȱ Note:ȱUnderȱnoȱcircumstancesȱmustȱtheȱduressȱcodeȱbeȱusedȱhaphazardlyȱorȱwithoutȱreason.ȱCentralȱ Stations,ȱalongȱwithȱPoliceȱDepartments,ȱtreatȱduressȱcodesȱveryȱseriouslyȱandȱtakeȱimmediateȱaction.ȱȱ ȱ DisarmingȱafterȱanȱAlarm:ȱ Whenȱsilencingȱanȱalarmȱtheȱsystemȱgoesȱintoȱaȱdisarmȱstate.ȱAfterȱtheȱsystemȱisȱ disarmedȱtheȱsirensȱwillȱsoundȱ4ȱsirenȱchirpsȱindicatedȱthatȱanȱalarmȱoccurredȱinȱtheȱ system.ȱOnȱtheȱkeypad,ȱpressȱ lastȱalarm.ȱȱ forȱ2ȱsecondsȱinȱorderȱtoȱviewȱinformationȱaboutȱtheȱ IfȱanȱȈEntryȱdoorȈȱisȱopenedȱpriorȱtoȱdisarmingȱtheȱsystem,ȱtheȱfollowingȱvoiceȱ announcementȱmessageȱwillȱbeȱheard:ȱȈAlarmȱoccurredȱinȱtheȱsystemȈ.ȱPressȱtheȱ keyȱwillȱindicateȱtheȱcauseȱofȱtheȱalarm.ȱ Page 15 ȱ ȱ AgilityȱUserȱManualȱ Note:ȱIfȱanȱalarmȱoccurredȱinȱtheȱsystem,ȱitȱisȱrecommendedȱtoȱleaveȱtheȱpremises.ȱOnlyȱafterȱpoliceȱ investigationȱshouldȱyouȱconsiderȱthatȱtheȱburglarȱisȱnoȱlongerȱonȱyourȱpremisesȱandȱyouȱcanȱreȬenter.ȱ Inȱspecialȱcasesȱ(ifȱprogrammedȱbyȱyourȱinstaller)ȱarmingȱtheȱsystemȱafterȱanȱalarmȱmightȱrequireȱaȱ technicianȱcode.ȱForȱmoreȱinformationȱreferȱtoȱyourȱinstaller.ȱ Yourȱinstallerȱcanȱdefineȱtheȱnumberȱofȱtimesȱ(0Ȭ15)ȱthatȱanȱalarmȱwillȱbeȱsentȱfromȱtheȱsameȱdetectorȱ duringȱoneȱarmingȱperiod.ȱThisȱisȱusuallyȱusedȱtoȱpreventȱanȱalarmȱfromȱaȱmalfunctionȱdetector,ȱanȱ environmentalȱproblemȱorȱincorrectȱinstallationȱ ȱ Resettingȱafterȱanȱalarm:ȱ YourȱinstallationȱcompanyȱcanȱdefineȱthatȱtheȱresetȱofȱtheȱsystemȱtoȱaȱNormalȱOperationȱ modeȱwillȱrequireȱtheȱinterventionȱofȱyourȱmonitoringȱstationȱorȱinstaller.ȱInȱthisȱcase,ȱ afterȱanȱalarmȱconditionȱtheȱsystemȱwillȱbeȱregardedȱasȱNotȱReadyȱandȱwhileȱrequestingȱ forȱsystemȱstatusȱ( )indicationȱyouȱwillȱgetȱaȱtroubleȱmessage:ȱTechnicianȱReset.ȱȱ AntiȱCodeȱResetȱȱ 1. Pressȱ .ȱȱ Enterȱuserȱcodeȱ GoȱtoȱActivitiesȱ>ȱAntiȱCodeȱoption.ȱ 2. Callȱyourȱmonitoringȱstationȱ(MS)ȱorȱinstallerȱandȱquoteȱtheȱ“RANDOMȱ CODE”ȱdisplayedȱonȱyourȱkeypad.ȱTheȱMSȱorȱinstallerȱwillȱgiveȱyouȱaȱreturnȱ AntiȬCode.ȱ 3. EnterȱthisȱAntiȱcodeȱfollowedȱbyȱ andȱtheȱsystemȱwillȱreset.ȱȱ InstallerȱResetȱ Yourȱmonitoringȱstationȱ(MS)ȱorȱinstallerȱcanȱresetȱyourȱsystemȱremotelyȱorȱlocallyȱ fromȱtheȱkeypad.ȱȱ Toȱenableȱlocalȱresetȱbyȱyourȱinstallerȱyouȱmayȱneedȱtoȱauthorizeȱhimȱusingȱtheȱmasterȱ codeȱafterȱtheȱinstallerȱentersȱhisȱcode.ȱAȱoneȱhourȱtimeȱwindowȱisȱopenedȱforȱtheȱ installerȱtoȱprogramȱuserȱfunctionsȱandȱbeȱableȱtoȱresetȱyourȱsystemȱlocallyȱȱ Page 16 AgilityȱUserȱManualȱ ȱ 2.3 Sending a Panic Alarm Panicȱalarmsȱenableȱyouȱtoȱsendȱaȱmessageȱtoȱtheȱmonitoringȱstationȱinȱtheȱeventȱofȱanȱ emergency,ȱsendȱaȱmessageȱtoȱaȱfollowȱmeȱnumber,ȱannounceȱaȱlocalȱmessageȱorȱactivateȱaȱ localȱalarm.ȱPanicȱalarmsȱcanȱbeȱsetȱtoȱbeȱsilentȱ(Referȱtoȱyourȱinstallerȱforȱmoreȱ information).ȱȱ ToȱsendȱaȱPanicȱ Alarmȱusing Procedure Pressȱbothȱ ȱand Pressȱbothȱ ȱandȱ ȱkeysȱsimultaneouslyȱ keysȱsimultaneouslyȱ Note:ȱYourȱinstallerȱshouldȱdefineȱtheseȱkeysȱtoȱbeȱsetȱasȱpanicȱkeys.ȱTheseȱkeysȱ canȱbeȱeitherȱdisabledȱorȱusedȱtoȱestablishȱaȱserviceȱcallȱtoȱyourȱ MonitoringȱStation.ȱȱ ȱ Ifȱdefinedȱbyȱyourȱinstallerȱpressingȱ simultaneouslyȱforȱ2ȱ secondsȱwillȱsendȱaȱfireȱalarmȱandȱpressingȱ ȱsimultaneouslyȱ forȱ2ȱsecondsȱwillȱsendȱaȱspecialȱemergencyȱorȱmedicalȱalarm.ȱȱ Pressȱtheȱsmallȱblankȱbuttonȱ(ifȱdefined)ȱ ȱ Note:ȱYourȱinstallerȱcanȱdefineȱtheȱsmallȱblankȱbuttonȱtoȱbeȱusedȱforȱsendingȱaȱ panicȱalarm.ȱȱ Note:ȱForȱfullȱcapabilitiesȱofȱtheȱ2Ȭwayȱremoteȱcontrol,ȱtheȱbiȬdirectionalȱkeypadȱandȱ4ȱbuttonȱkeyȱfob,ȱ referȱtoȱtheȱinstructionsȱsuppliedȱwithȱeachȱproduct.ȱȱ Pressȱbothȱȱkeysȱsimultaneouslyȱ Pressȱtheȱpanicȱbuttonȱ Page 17 ȱ AgilityȱUserȱManualȱ Chapter 3 - Remote System Operation 3.1 Remote Phone Operation TheȱAgilityȱenablesȱyouȱtoȱoperateȱtheȱsystemȱfromȱaȱremoteȱtouchȬtoneȱphoneȱbyȱ initiatingȱaȱtelephoneȱcallȱtoȱorȱfromȱtheȱsystemȱandȱinteractingȱwithȱvoiceȱmenusȱthatȱ guideȱyouȱthroughȱyourȱrequiredȱremoteȱoperation.ȱȱ Remotely Accessing the System Remotelyȱaccessingȱtheȱsystemȱinvolvesȱinitiatingȱaȱcallȱtoȱtheȱsystem,ȱandȱenteringȱyourȱ remoteȱaccessȱcodeȱandȱtheȱuserȱcodeȱyouȱusuallyȱenterȱinȱtheȱsystemȱkeypad.ȱ Toȱremotelyȱaccessȱtheȱsystem:ȱ 1. FromȱaȱremoteȱtouchȬtoneȱtelephone,ȱdialȱtheȱnumberȱofȱtheȱpremisesȱwhereȱ Agilityȱisȱinstalled.ȱȱ 2. Ifȱyourȱsystemȱisȱconnectedȱtoȱaȱlandȱtelephoneȱlineȱandȱanȱansweringȱ machineȱisȱinȱuseȱatȱtheȱpremisesȱletȱtheȱlineȱringȱonce,ȱthenȱhangȱupȱandȱcallȱ again.ȱ Ifȱanȱansweringȱmachineȱisȱnotȱinȱuseȱatȱtheȱpremisesȱwaitȱuntilȱtheȱsystemȱ picksȱup.ȱAfterȱtheȱsystemȱpicksȱupȱaȱshortȱtoneȱisȱheard.ȱ Note:ȱWhenȱtheȱsystemȱpicksȱup,ȱallȱphonesȱonȱtheȱsameȱlineȱareȱeffectivelyȱdisconnectedȱandȱ cannotȱbeȱused.ȱ 3. Enterȱyourȱ2ȱdigitȱremoteȱaccessȱcodeȱwithinȱ10ȱsecondsȱ(Defaultȱcodeȱ=ȱ00).ȱȱ Theȱfollowingȱmessageȱisȱannounced:ȱȈHello,ȱPleaseȱEnterȱYourȱUserȱCode,ȱ FollowedȱByȱ[#]Ȉ.ȱȱ Enterȱyourȱuserȱcodeȱfollowedȱbyȱ[#].ȱ(Defaultȱcode=1234)ȱ 4. Afterȱyourȱcodeȱisȱacceptedȱaȱsystemȱstatusȱmessageȱisȱannounced,ȱfollowedȱbyȱ theȱOperationsȱmenu.ȱYouȱcanȱnowȱperformȱtheȱrequiredȱremoteȱoperations.ȱ Voice Operations Menu TheȱVoiceȱOperationsȱmenuȱannouncesȱoptionsȱandȱinstructionsȱonȱhowȱtoȱuseȱtheȱsystemȱ functions.ȱTheȱoptionsȱinȱtheȱOperationsȱmenuȱvaryȱaccordingȱtoȱsystemȱstatusȱandȱyourȱ accessȱrights.ȱȱ Followingȱisȱaȱlistȱofȱtheȱremoteȱoperationsȱoptions:ȱ Operation Quick Key Combination Armingȱallȱpartitionsȱ Pressȱ[1][1]ȱ Armingȱaȱselectedȱpartitionȱ Pressȱ[1][9]ȱfollowedȱbyȱtheȱpartitionȱnumberȱ Disarmingȱallȱpartitionsȱ Pressȱ[2][2]ȱ Disarmingȱaȱselectedȱpartitionȱ Pressȱ[2][9]ȱfollowedȱbyȱtheȱpartitionȱnumberȱ Page 18 AgilityȱUserȱManualȱ ȱ Operation Quick Key Combination ChangingȱZoneȱBypassȱstatusȱ Pressȱ[3]ȱfollowedȱbyȱtheȱzoneȱnumberȱandȱthenȱ[#][9]ȱ OperatingȱUtilityȱOutputsȱ Pressȱ[4]ȱfollowedȱbyȱtheȱoutputȱnumberȱ ChangingȱFollowȱMe(FM)ȱ numbersȱ Pressȱ[5]ȱfollowedȱbyȱtheȱFMȱnumberȱandȱ[#][2].ȱ Enterȱtheȱnewȱphoneȱnumberȱandȱpressȱ[#][1].ȱ Listenȱinȱtoȱtheȱpremisesȱ Pressȱ[6][1]ȱ Talkingȱtoȱtheȱpremisesȱ Pressȱ[6][2]ȱ ListenȱandȱTalkȱtoȱtheȱpremisesȱ Pressȱ[6][3]ȱ Recordingȱmessagesȱthatȱareȱnotȱ includedȱinȱtheȱmessageȱbankȱ(5ȱ messages)ȱ Pressȱ[7][1]…ȱ[5]ȱ Recordingȱanȱopeningȱmessageȱ Pressȱ[7][6]ȱ ExitingȱtheȱSystemȱ Pressȱ[0]ȱ Toȱreturnȱtoȱtheȱpreviousȱmenuȱ Pressȱ[*]ȱ Toȱrepeatȱtheȱmenuȱoptionsȱ Pressȱ[#]ȱ Receiving Calls from the System Uponȱeventȱoccurrence,ȱsuchȱasȱalarmȱactivation,ȱtheȱsystemȱinformsȱyouȱofȱsecurityȱ situations,ȱforȱexample,ȱintrusionȱorȱfire,ȱbyȱcallingȱyouȱandȱannouncingȱaȱpreȬrecordedȱ eventȱannouncementȱmessage,ȱfollowedȱbyȱtheȱAcknowledgeȱmenu.ȱTheȱsystemȱcanȱcallȱ upȱtoȱ16ȱFollowȱMeȱnumbers,ȱenablingȱyou,ȱaȱrelativeȱorȱneighborȱtoȱbeȱinformedȱofȱtheȱ securityȱsituation.ȱYouȱcanȱthenȱtakeȱtheȱappropriateȱaction,ȱwhetherȱthisȱisȱtoȱinformȱtheȱ authoritiesȱorȱacknowledgeȱtheȱeventȱandȱremotelyȱoperateȱtheȱsystem.ȱ Notes:ȱFollowȱMeȱmessagesȱareȱperformedȱonlyȱafterȱreportingȱtoȱtheȱMonitoringȱStation.ȱȱ FollowȱMeȱnumbersȱareȱassignedȱcertainȱeventsȱforȱwhichȱtheyȱreceiveȱcalls.ȱȱ TheȱsystemȱmustȱbeȱprogrammedȱtoȱcallȱaȱFMȱnumberȱafterȱaȱspecificȱeventȱoccursȱinȱorderȱforȱthatȱ eventȱtoȱtriggerȱtheȱcall.ȱ Toȱreceiveȱanȱeventȱcall:ȱ 1. 2. Pickȱupȱtheȱphone.ȱ SayȱȈHelloȈȱorȱpressȱ[#].ȱTheȱEventȱAnnouncementȱmessageȱisȱmade,ȱinformingȱ youȱofȱaȱsecurityȱsituationȱinȱyourȱsystem,ȱforȱexample:ȱȱ “24ȱOaklandsȱStreet,ȱIntruderȱalarm,ȱGroundȱFloor,ȱkitchen”ȱȱ Notes:ȱIfȱnoȱvoiceȱisȱdetected,ȱtheȱeventȱmessageȱwillȱstartȱplayingȱ5ȱsecondsȱafterȱphoneȱpickȱup.ȱPressȱ[#]ȱtoȱ beginȱplaybackȱofȱtheȱeventȱmessageȱfromȱtheȱbeginning.ȱ ToȱrepeatȱtheȱEventȱAnnouncementȱmessageȱpressȱ[#].ȱ ToȱbypassȱtheȱEventȱAnnouncementȱmessageȱandȱgoȱdirectlyȱtoȱtheȱAcknowledgeȱmenu,ȱpressȱ[*].ȱ 3. Acknowledgeȱtheȱevent.ȱ(SeeȱAcknowledgeȱMenu)ȱ Page 19 ȱ AgilityȱUserȱManualȱ Acknowledge Menu AfterȱtheȱEventȱAnnouncementȱmessageȱisȱmade,ȱtheȱfollowingȱlistȱofȱoptionsȱisȱ announced:ȱ Operation Digit AcknowledgeȱMessageȱ Acknowledgingȱanȱeventȱmeansȱthatȱyouȱhaveȱreceivedȱaȱmessageȱfromȱ theȱsecurityȱalarmȱsystemȱaboutȱaȱrelevantȱeventȱinȱtheȱsystemȱandȱ wantȱtoȱconfirmȱthis.ȱAfterȱyouȱacknowledgeȱanȱevent,ȱtheȱsystemȱcallsȱ theȱnextȱFMȱnumber.ȱȱ Pressȱ[1]ȱ Acknowledgeȱandȱstopȱallȱdialingȱ Thisȱoptionȱacknowledgesȱtheȱeventȱandȱstopsȱtheȱsystemȱfromȱcallingȱ theȱnextȱFMȱnumbersȱtoȱreportȱtheȱevent.ȱ Pressȱ[2]ȱ followedȱbyȱ theȱcodeȱ AcknowledgeȱandȱaccessȱtheȱOperationsȱmenuȱ TheȱOperationsȱmenuȱlistsȱtheȱavailableȱoptionsȱforȱremotelyȱoperatingȱ yourȱsystem.ȱ Pressȱ[3]ȱ followedȱbyȱ theȱcodeȱ ListenȱInȱandȱTalkȱ ThisȱoptionȱenablesȱyouȱtoȱperformȱbiȬdirectionalȱcommunication.ȱ Pressȱ[6]ȱ followedȱbyȱ theȱcodeȱ Repeatȱtheȱeventȱmessageȱ Pressȱ[#]ȱ RepeatȱtheȱAcknowledgeȱmenuȱ Pressȱ[*]ȱ Note:ȱIfȱanȱinvalidȱcodeȱisȱenteredȱ3ȱconsecutiveȱtimes,ȱtheȱsystemȱhangsȱupȱandȱthisȱFMȱnumberȱisȱlockedȱ forȱ15ȱminutesȱandȱnoȱcallsȱareȱinitiatedȱtoȱtheȱFMȱnumber.ȱȱ Ifȱaȱvalidȱuserȱcodeȱisȱnotȱenteredȱwithinȱ10ȱseconds,ȱtheȱsystemȱhangsȱup.ȱ Bi-directional Communication TheȱListenȱInȱandȱTalkȱoptionsȱenableȱyouȱtoȱremotelyȱandȱsilentlyȱlistenȱinȱtoȱyourȱ premisesȱinȱorderȱtoȱverifyȱtheȱcauseȱofȱanȱeventȱoccurrence,ȱthroughȱtheȱmicrophoneȱorȱ remotelyȱtalkȱtoȱyourȱpremisesȱviaȱtheȱAgilityȱloudspeaker,ȱforȱexample,ȱtoȱguideȱsomeoneȱ inȱdistress.ȱȱ Toȱlistenȱinȱorȱtalk:ȱ 1. FromȱtheȱOperations/Acknowledgeȱmenu,ȱpressȱ[6].ȱTheȱfollowingȱmessagesȱareȱ announced:ȱȱ “ToȱListenȱInȱpressȱ1,ȱToȱTalkȱpressȱ[2],ȱToȱListenȱandȱTalkȱ(Openȱchannel)ȱpressȱ [3],ȱToȱreturnȱtoȱtheȱpreviousȱmenu,ȱPressȱ[¾].”ȱ 2. Selectȱtheȱdesiredȱoption.ȱȱȱȱ 3. Pressȱ[¾]ȱtoȱendȱlisteningȱinȱandȱtalkingȱcommunicationȱandȱreturnȱtoȱtheȱ Operationsȱmenu.ȱ ȱ Page 20 AgilityȱUserȱManualȱ ȱ Bi-directional Audio Options after an Alarm InȱtheȱeventȱofȱBurglary,ȱFireȱandȱMedicalȱalarms,ȱtheȱAgilityȱisȱableȱtoȱreportȱtheseȱeventsȱ andȱthenȱstayȱonȱtheȱline.ȱThisȱallowsȱtheȱmonitoringȱserviceȱtoȱperformȱVoiceȱAlarmȱ verification,ȱverifyȱtheȱalarmȱorȱVerificationȱinȱorderȱtoȱverifyȱaȱcauseȱofȱeventȱorȱguideȱ someoneȱinȱdistress.ȱ Service call ȱTheȱServiceȱCallȱfeatureȱenablesȱyouȱtoȱcallȱtheȱMonitoringȱStationȱbyȱpressingȱaȱkey.ȱToȱ establishȱtheȱserviceȱcall,ȱpressȱtheȱbuttonȱonȱtheȱmainȱunitȱorȱpressȱsimultaneouslyȱtheȱ buttonsȱ ȱ ȱonȱtheȱbiȬdirectionalȱkeypad.ȱ Note:ȱTheȱServiceȱcallȱshouldȱbeȱdefinedȱbyȱyourȱinstaller.ȱ 3.2 SMS Operation SMS Remote Control TheȱAgilityȱenablesȱyouȱtoȱperformȱremoteȱcontrolȱoperationsȱusingȱsimpleȱSMSȱ commands.ȱTheȱfollowingȱsectionȱdescribesȱtheȱSMSȱcommandsȱandȱtheȱresponseȱofȱtheȱ systemȱtoȱtheseȱcommands.ȱ Note:ȱThisȱapplicationȱisȱavailableȱonlyȱifȱaȱGSM/GPRSȱmoduleȱisȱinstalledȱinȱyourȱsystem.ȱ Operation Armȱallȱpartitionsȱofȱaȱ userȱcodeȱ Armȱallȱpartitionsȱtoȱ Stay/HomeȱArmingȱ Disarmȱallȱpartitionsȱ ofȱaȱuserȱcodeȱ Armȱbyȱpartitionȱ Stay/Homeȱarmȱbyȱ partitionȱ DisarmȱbyȱPartitionȱȱ Bypassȱaȱzoneȱ UnȬbypassȱaȱzoneȱ ActivateȱOutputȱ DeactivateȱOutputȱȱ ChangeȱFMȱnumberȱȱ ȱ Getȱsystemȱstatusȱ Getȱlastȱalarmȱ memoryȱ GetȱSIMȱcreditȱlevelȱ (forȱprepaidȱcards)ȱ SMS Message Structure [Code]ȱAȱȱ Example 1234Aȱ [Code]ȱHȱ 1234Hȱ [Code]ȱDȱȱ 1234Dȱ [Code]ȱAȱ[PartitionȱNo.]ȱ [Code]ȱHȱ[PartitionȱNo.]ȱ 1234A1ȱ 1234H1ȱ [Code]ȱDȱ[PartitionȱNo.]ȱ [Code]ȱBȱ[zoneȱnumber]ȱ [Code]ȱUBȱ[zoneȱNo.]ȱ [Code]ȱUOONȱ[UOȱNo.]ȱ [Code]ȱUOOFFȱ[UOȱNo.]ȱ [Code]ȱFMPHONEȱ[FMȱserialȱnumber]ȱȱ NEWȱ[NewȱPhoneȱNo.)ȱ [Code]ȱSTȱ [Code]ȱALȱ 1234D1ȱ 1234B05ȱ 1234UB05ȱ 1234UOON1ȱ 1234UOOFF1ȱ 1234FMPHONEȱ3ȱ NEW0529692345ȱ 1234STȱ 1234ALȱ [Code]ȱCRȱ 1234CRȱ Page 21 ȱ AgilityȱUserȱManualȱ Notes:ȱSMSȱcommandsȱcanȱbeȱsentȱfromȱanyȱmobileȱphoneȱorȱfromȱanȱSMSȱwebsite.ȱ Commandȱwordsȱareȱnotȱcaseȱsensitive.ȱ Aȱseparatorȱbetweenȱcommandȱwordsȱisȱnotȱrequiredȱalthoughȱitȱisȱaccepted.ȱ SMS Confirmation Message AȱconfirmationȱmessageȱfollowingȱaȱSMSȱoperationȱisȱsentȱtoȱtheȱuser,ȱuponȱrequest,ȱbyȱ addingȱtheȱlettersȱ“RP”ȱatȱtheȱendȱofȱtheȱSMSȱmessagesȱlistedȱbelow.ȱ Example:ȱ 1234ȱAȱRPȱȬȱAȱconfirmationȱmessageȱfollowingȱanȱarmingȱoperationȱwillȱbeȱsentȱtoȱtheȱ user.ȱȱ ConfirmationȱorȱFailȱoperationȱmessagesȱcanȱbeȱassignedȱtoȱtheȱactionsȱofȱarming,ȱ disarming,ȱbypassing,ȱactivatingȱoutputsȱorȱchangingȱfollowȱmeȱdefinitions.ȱȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ Page 22 AgilityȱUserȱManualȱ ȱ Chapter 4 - User Functions and Settings Theȱfunctionsȱandȱsettingsȱexplainedȱinȱthisȱchapterȱcanȱonlyȱbeȱperformedȱviaȱyourȱ keypadȱandȱtheȱConfigurationȱSoftware.ȱThisȱchapterȱrefersȱtoȱtheseȱfunctionsȱandȱsettingsȱ asȱperformedȱviaȱtheȱkeypad.ȱReferȱtoȱtheȱConfigurationȱSoftwareȱmanualȱforȱmoreȱ informationȱregardingȱhowȱtheseȱfunctionsȱandȱsettingsȱareȱperformedȱviaȱtheȱ ConfigurationȱSoftware.ȱ Whenȱusingȱtheȱkeypadȱduringȱtheȱprogrammingȱmodeȱuseȱtheȱfollowingȱtableȱtoȱbeȱ familiarȱwithȱtheȱfunctionalityȱofȱtheȱkeys:ȱ Function Sequence Exitsȱfromȱtheȱcurrentȱmenuȱȱ ȱ Terminatesȱcommandsȱandȱconfirmsȱdataȱtoȱbeȱstoredȱ ȱ Usedȱtoȱbrowseȱthroughȱtheȱmenu:ȱScrollsȱupȱaȱlistȱorȱmovesȱtheȱcursorȱ ȱ Changesȱdataȱ ȱ Numericalȱkeysȱareȱusedȱtoȱinputȱtheȱnumericȱcodesȱthatȱmayȱbeȱrequiredȱ forȱarming,ȱdisarming,ȱorȱusedȱtoȱactivateȱspecificȱfunctionsȱ ȱ ȱ 4.1 User Codes ToȱperformȱmanyȱofȱtheȱAgilityȱfunctions,ȱaȱsecurityȱcodeȱ(oftenȱcalledȱaȱuserȱcode)ȱmustȱ beȱused.ȱEachȱindividualȱusingȱtheȱsystemȱisȱassignedȱaȱuserȱcode,ȱwhich,ȱinȱturn,ȱisȱlinkedȱ toȱanȱAuthorityȱLevel.ȱThoseȱwithȱaȱȈhigherȱauthorityȈȱhaveȱaccessȱtoȱaȱgreaterȱnumberȱofȱ systemȱfunctions,ȱwhileȱthoseȱwithȱaȱȈlowerȱauthorityȈȱareȱmoreȱrestrictedȱinȱwhatȱtheyȱ mayȱdo.ȱThereȱareȱfourȱdifferentȱauthorityȱlevelsȱavailableȱforȱusersȱofȱtheȱAgility.ȱ Notes:ȱToȱdefineȱtheȱauthorityȱlevelsȱreferȱtoȱyourȱinstaller.ȱȱ Agilityȱcanȱsupportȱupȱtoȱ32ȱdifferentȱuserȱcodes.ȱUserȱcodesȱmayȱhaveȱvariableȱlengthsȱupȱtoȱ6ȱdigits.ȱ YourȱAgilityȱwasȱgivenȱaȱGrandȱMasterȱCodeȱofȱ1Ȭ2Ȭ3Ȭ4ȱduringȱmanufacturing.ȱUnlessȱyourȱalarmȱ companyȱhasȱalreadyȱchangedȱitȱtoȱsuitȱyourȱpreference,ȱitȇsȱbestȱtoȱmodifyȱthisȱcodeȱtoȱoneȱthatȱisȱ uniqueȱandȱpersonalizedȱasȱhereinȱdescribed.ȱ Page 23 ȱ AgilityȱUserȱManualȱ Setting / Changing User Codes TheȱuserȱassignedȱtheȱGrandȱMasterȱauthorityȱlevelȱcanȱchangeȱallȱuserȱcodesȱbutȱcannotȱ viewȱtheȱdigitsȱinȱtheȱuserȱcodeȱfields.ȱUsersȱwithȱotherȱauthorityȱlevelsȱcanȱonlyȱchangeȱ theirȱownȱcodes.ȱTheȱsystemȱmustȱbeȱdisarmedȱinȱorderȱtoȱsetȱorȱchangeȱuserȱcodes.ȱ Toȱset/changeȱaȱuserȱcode:ȱ andȱȱ 1. Pressȱ 2. Enterȱyourȱcodeȱ 3. Usingȱtheȱarrowȱkeys,ȱscrollȱtoȱtheȱoptionȱCodes/Tagsȱandȱpressȱ .ȱ Note:ȱIfȱyouȱenterȱaȱwrongȱuserȱcode,ȱtheȱkeypadȱproducesȱ3ȱshortȱbeepsȱandȱtheȱȈWrongȱCode.ȱPleaseȱTryȱ AgainȈȱmessageȱwillȱbeȱheard.ȱPressȱ ȱquicklyȱandȱreȬenterȱtheȱaboveȱsequenceȱcorrectly.ȱ 4. ScrollȱtoȱUserȱCodesȱandȱpress 5. YouȱwillȱseeȱtheȱoptionȱNew/Change.ȱPress 6. UsingȱtheȱarrowsȱscrollȱtoȱselectȱtheȱUserȱIndexȱnumberȱtoȱwhichȱyouȱwantȱtoȱ assignȱaȱuserȱcodeȱandȱpressȱ .ȱ ȱȱ .ȱȱ Note:ȱInȱtheȱAgilityȱsystem,ȱtheȱUserȱIndexȱnumberȱisȱfromȱ00ȱtoȱ32,ȱwhereȱ00ȱbelongsȱtoȱtheȱGrandȱMaster.ȱ 7. EnterȱtheȱnewȱcodeȱandȱthenȱreȬenterȱtheȱcode.ȱIfȱsuccessful,ȱaȱsingleȱ confirmationȱbeepȱisȱsounded,ȱifȱnot,ȱ3ȱquickȱerrorȱbeepsȱareȱsoundedȱ 8. Repeatȱtheȱaboveȱstepsȱforȱadditionalȱcodesȱuntilȱyouȱhaveȱcompletedȱyourȱlistȱ Deleting User Codes Atȱtimes,ȱyouȱmayȱwantȱtoȱcompletelyȱdeleteȱaȱuserȱcode.ȱNoteȱthatȱitȱisȱimpossibleȱtoȱ deleteȱtheȱMasterȱCodeȱ(althoughȱitȱcanȱbeȱchanged).ȱ Theȱsystemȱmustȱbeȱdisarmedȱinȱorderȱtoȱdeleteȱuserȱcodes.ȱ Toȱset/changeȱaȱuserȱcode:ȱ 1. Followȱstepsȱ1Ȭ4ȱofȱtheȱpreviousȱprocedureȱ(SeeȱSetting/ChangingȱUserȱCodes)ȱ 2. 3. ȱ ScrollȱtheȱmenuȱtoȱtheȱoptionȱȈDeleteȱByȱUserȈ.ȱPress UsingȱtheȱarrowsȱscrollȱtoȱselectȱtheȱUserȱIndexȱnumberȱwhichȱyouȱwantȱtoȱ deleteȱandȱpress .ȱ ȱkeyȱtoȱselectȱ 4. Theȱdisplayȱwillȱshow:ȱȈDeleteȱUser.ȱAreȱyouȱsure?Ȉ.ȱȱUseȱtheȱ 5. [Y]ȱandȱpressȱ .ȱIfȱsuccessful,ȱaȱsingleȱconfirmationȱbeepȱisȱsounded,ȱifȱnot,ȱ3ȱ quickȱerrorȱbeepsȱareȱsoundedȱ Repeatȱtheȱaboveȱstepsȱforȱdeletingȱadditionalȱcodesȱ Page 24 AgilityȱUserȱManualȱ ȱ 4.2 Proximity Tags TheȱbiȬdirectionalȱkeypadȱenablesȱyouȱtoȱreplaceȱtheȱuseȱofȱaȱcodeȱwithȱaȱproximityȱtagȱtoȱ armȱandȱdisarmȱtheȱsecurityȱsystemȱorȱtoȱactivateȱandȱdeactivateȱhomeȱappliancesȱandȱ utilities,ȱsuchȱasȱheatingȱandȱlights.ȱȱProximityȱtagȱprogrammingȱisȱperformedȱfromȱtheȱ UserȱFunctionsȱmenu.ȱWhenȱprogrammingȱaȱproximityȱtag,ȱtheȱfollowingȱthreeȱoptionsȱareȱ available:ȱ Addingȱaȱnewȱtagȱ Deletingȱaȱtagȱbyȱtheȱuserȱserialȱnumberȱ Deletingȱaȱtagȱbyȱtheȱuserȱtagȱ Adding a Proximity Tag TheȱGrandȱMasterȱcanȱassignȱaȱtagȱtoȱanyȱuserȱinȱtheȱsystem.ȱEachȱproximityȱtagȱcanȱbeȱ assignedȱtoȱonlyȱoneȱuser.ȱ Toȱaddȱaȱproximityȱtag:ȱ 1. Pressȱ ȱ 2. Enterȱyourȱuserȱcodeȱ 3. UsingȱtheȱarrowȱkeysȱscrollȱtoȱtheȱoptionȱCodes/TagsȱfromȱtheȱUserȱFunctionsȱ menuȱandȱpressȱ ȱ .ȱ 4. ScrollȱtoȱProximityȱTagsȱandȱpressȱ 5. SelectȱtheȱoptionȱNew/Change.ȱPress 6. UsingȱtheȱarrowsȱscrollȱtoȱselectȱtheȱUserȱIndexȱnumberȱtoȱwhichȱyouȱwantȱtoȱ assignȱaȱtag.ȱȱ 7. Withinȱ10ȱseconds,ȱholdȱtheȱproximityȱtagȱatȱaȱdistanceȱofȱ1ȱtoȱ2ȱcm.ȱfromȱtheȱ keypad’sȱkeys.ȱTheȱkeypadȱautomaticallyȱreadsȱtheȱproximityȱtagȱandȱsavesȱitȱ intoȱtheȱsystem’sȱmemory.ȱOnceȱtheȱproximityȱtagȱhasȱbeenȱsuccessfullyȱ recorded,ȱaȱlongȱconfirmationȱbeepȱsounds,ȱandȱaȱconfirmationȱmessageȱisȱ displayed.ȱIfȱtheȱproximityȱtagȱisȱalreadyȱstoredȱinȱtheȱsystem’sȱmemory,ȱ3ȱerrorȱ beepsȱwillȱsoundȱandȱaȱrejectȱmessageȱwillȱappear.ȱȱ ȱ ȱ Page 25 .ȱȱ ȱ AgilityȱUserȱManualȱ Deleting a proximity tag Deletingȱproximityȱtagsȱcanȱbeȱdoneȱbyȱinȱtwoȱoptions:ȱ Byȱuserȱnumber:ȱUseȱthisȱoptionȱtoȱdeleteȱaȱtagȱforȱwhichȱtheȱuserȱisȱknownȱ Byȱtag:ȱUseȱthisȱoptionȱtoȱdeleteȱaȱtagȱforȱwhichȱtheȱuserȱisȱnotȱknownȱ Toȱdeleteȱbyȱuser:ȱ 1. Followȱstepsȱ1Ȭ4ȱofȱtheȱpreviousȱprocedureȱ(SeeȱSetting/ChangingȱUserȱCodes)ȱ 2. 3. ScrollȱtheȱmenuȱtoȱtheȱoptionȱDeleteȱbyȱuser.ȱPressȱ ȱ Usingȱtheȱarrowsȱscrollȱtoȱselectȱtheȱuserȱforȱwhichȱyouȱwantȱtoȱdeleteȱtheȱ proximityȱtagȱandȱpressȱ 4. .ȱ Theȱdisplayȱwillȱshow:ȱȈDeleteȱUser.ȱAreȱyouȱsure?Ȉ.ȱȱUseȱtheȱ ȱkeyȱtoȱselectȱ [Y]ȱandȱpressȱ .ȱIfȱsuccessful,ȱaȱsingleȱconfirmationȱbeepȱisȱsounded,ȱifȱnot,ȱ3ȱ quickȱerrorȱbeepsȱareȱsounded.ȱ Toȱdeleteȱbyȱtag:ȱ 1. Followȱstepsȱ1Ȭ4ȱofȱtheȱpreviousȱprocedureȱ(SeeȱSetting/ChangingȱUserȱCodes).ȱȱ 2. 3. ScrollȱtheȱmenuȱtoȱtheȱoptionȱDeleteȱbyȱtag.ȱPressȱ ȱ Withinȱ10ȱseconds,ȱapproachȱtheȱproximityȱtagȱatȱaȱdistanceȱofȱ1ȱtoȱ2ȱcm.ȱfromȱ theȱkeypad’sȱkeys.ȱAȱconfirmationȱmessageȱwillȱbeȱdisplayed.ȱ 4.3 Defining Follow Me Destinations Inȱtheȱcaseȱofȱanȱalarmȱorȱevent,ȱtheȱsystemȱcanȱinitiateȱaȱphoneȱcallȱtoȱaȱdesignatedȱ telephone,ȱsendȱaȱSMSȱorȱsendȱanȱEȬmailȱandȱemployȱuniqueȱtonesȱorȱmessagesȱtoȱexpressȱ theȱactiveȱevent.ȱ Toȱenter/editȱaȱFollowȱMeȱnumber:ȱ 1. 2. Pressȱ ȱ Enterȱyourȱuserȱcodeȱ 3. ScrollȱtheȱmenuȱusingȱtheȱarrowȱkeysȱtoȱtheȱoptionȱFollowȱMeȱandȱpressȱ 4. SelectȱtheȱFollowȱMeȱindexȱnumberȱyouȱwantȱtoȱeditȱandȱpressȱ 5. 6. ȱtoȱenterȱtheȱDefineȱmenu.ȱ Pressȱ Enterȱtheȱphoneȱnumber,ȱincludingȱtheȱareaȱcodeȱ(ifȱrequired)ȱorȱanȱeȬmailȱ address,ȱasȱrequestedȱonȱtheȱscreenȱandȱpress ȱ .ȱ ȱ Upȱtoȱ32ȱdigitsȱcanȱbeȱincludedȱinȱtheȱphoneȱnumber.ȱ 7. Ifȱrequired,ȱincludeȱtheȱspecialȱfunctionsȱdescribedȱbelowȱtoȱachieveȱtheȱrelatedȱ effect.ȱYouȱcanȱpressȱthe ȱȱorȱ keysȱtoȱtoggleȱtoȱtheȱrequiredȱcharacter.ȱ Page 26 AgilityȱUserȱManualȱ ȱ ȱ Function Results Stopȱdialingȱandȱwaitȱforȱaȱnewȱdialȱtoneȱ Wȱ Waitȱaȱfixedȱperiodȱbeforeȱcontinuingȱ ,ȱ SendȱtheȱDTMFȱ¾ȱcharacterȱ ¾ȱ SendȱtheȱDTMFȱ#ȱcharacterȱ #ȱ Deleteȱnumbersȱfromȱtheȱcursorȱpositionȱ 8. Whenȱdoneȱwithȱyourȱcompleteȱentry,ȱpress ȱsimultaneouslyȱ toȱstoreȱit.ȱȱ 4.4 Scheduler TheȱAgilityȱenablesȱyouȱtoȱautomateȱsomeȱsystemȱoperations.ȱThisȱisȱperformedȱbyȱ definingȱweeklyȱprogramsȱbyȱyourȱinstaller.ȱEachȱprogramȱcanȱbeȱdefinedȱwithȱupȱtoȱtwoȱ timeȱintervalsȱperȱday,ȱduringȱwhichȱtheȱsystemȱautomaticallyȱperformsȱoneȱofȱtheȱ followingȱfunctions: AutomaticȱArming/Disarming:ȱAnȱarmingȱprogramȱautomaticallyȱarmsȱandȱ disarmsȱtheȱsystemȱduringȱyourȱrequiredȱtimeȱintervals.ȱȱ AutomaticȱUOȱActivation:ȱAȱUOȱ(homeȱappliance)ȱactivationȱprogramȱ automaticallyȱactivatesȱandȱdeactivatesȱUOsȱduringȱyourȱrequiredȱintervals.ȱȱ Inȱaddition,ȱeachȱprogramȱcanȱbeȱdefinedȱtoȱbeȱactivatedȱinȱaȱdifferentȱmannerȱduringȱ vacation.ȱ Onceȱyourȱinstallerȱdefinesȱaȱscheduleȱprogramȱitȱwillȱbeȱactivated.ȱȱ Youȱhaveȱtheȱoptionȱtoȱdeactivateȱaȱprogramȱaccordingȱtoȱyourȱneeds.ȱ Toȱdisableȱaȱweeklyȱprogram:ȱ 1. Pressȱ 2. Enterȱyourȱuserȱcodeȱ 3. ScrollȱtheȱmenuȱusingȱtheȱarrowȱkeysȱtoȱtheȱoptionȱClockȱandȱpressȱ 4. Pressȱ 5. SelectȱtheȱSchedulingȱprogramȱindexȱnumber.ȱUseȱtheȱ ȱ ȱ ȱtoȱenterȱtheȱSchedulerȱmenu.ȱ deactivateȱandȱpressȱ .ȱ ȱ Page 27 ȱkeyȱtoȱactivateȱ/ȱ ȱ AgilityȱUserȱManualȱ 4.5 Macro keys Programming Macro Keys AgilityȱenablesȱtheȱinstallerȱorȱGrandȱMasterȱtoȱrecordȱaȱseriesȱofȱcommandsȱandȱassignȱ themȱtoȱaȱmacro.ȱWhenȱtheȱmacroȱisȱpressed,ȱtheȱrecordedȱcommandsȱareȱexecutedȱfromȱ beginningȱtoȱend.ȱUpȱtoȱ3ȱmacrosȱcanȱbeȱprogrammedȱtoȱaȱsystemȱusingȱtheȱAgilityȱkeypadȱ orȱtheȱAgilityȱConfigurationȱSoftware.ȱȱ Beforeȱprogrammingȱaȱmacro,ȱitȱisȱrecommendedȱtoȱperformȱyourȱrequiredȱseriesȱofȱ commands,ȱmakingȱaȱnoteȱofȱeveryȱkeyȱyouȱpressȱwhileȱdoingȱso.ȱ Note:ȱMacrosȱcannotȱbeȱprogrammedȱtoȱperformȱdisarmingȱcommands.ȱ Toȱprogramȱaȱmacro:ȱ .ȱ 1. InȱtheȱMacroȱmenuȱselectȱaȱmacroȱ(A,ȱBȱorȱC)ȱandȱpress 2. Enterȱtheȱsequenceȱofȱcharactersȱaccordingȱtoȱtheȱfollowingȱtable:ȱ Key Represents Usedȱtoȱenterȱnumericalȱcharactersȱ ȱ ȱ Usedȱtoȱmoveȱtheȱcurserȱtoȱtheȱleftȱ Usedȱtoȱmoveȱtheȱcurserȱtoȱtheȱrightȱ ȱ Pressȱ1ȱtwiceȱ RepresentsȱtheȱÇȱcharacterȱ Pressȱ3ȱtwiceȱ RepresentsȱtheȱÈȱcharacterȱ Pressȱ4ȱtwiceȱ Representsȱtheȱ ȱkeyȱ Pressȱ6ȱtwiceȱ Representsȱtheȱ ȱkeyȱ Pressȱ7ȱtwiceȱ Representsȱtheȱ¾ȱcharacterȱ Pressȱ9ȱtwiceȱ Representsȱtheȱ#ȱcharacterȱ ȱandȱ0ȱsimultaneouslyȱ / Deletesȱyourȱentryȱfromȱtheȱcursorȱpositionȱforwardȱ Useȱtoȱtoggleȱbetweenȱ numericȱcharactersȱ / /Ç/È/#/¾ȱandȱallȱofȱtheȱ Usedȱtoȱendȱtheȱsequenceȱandȱsaveȱitȱtoȱmemoryȱ Page 28 AgilityȱUserȱManualȱ 3. ȱ Press ȱtoȱsaveȱyourȱentry.ȱȱ Theȱseriesȱofȱcharactersȱisȱsavedȱandȱassignedȱtoȱtheȱselectedȱmacro.ȱ ȱ Forȱexample:ȱ Toȱarmȱpartitionȱ1ȱwithȱtheȱcodeȱ1234,ȱenterȱtheȱfollowingȱsequence:ȱ 1ȱ ȱ1ȱ2ȱ3ȱ4ȱȱ Activating a Macro Pressȱ7/8/9ȱonȱtheȱkeypadȱforȱ2ȱsecondsȱtoȱactivateȱtheȱmacroȱA/B/Cȱrespectively.ȱAȱ confirmationȱmessageȱwillȱbeȱheard:ȱȱ Ȉ[MacroȱX]ȱactivatedȈ.ȱ Page 29 ȱ AgilityȱUserȱManualȱ 4.6 Complete Menu of User Functions TheȱAgilityȱcomesȱwithȱaȱvarietyȱofȱselectableȱuserȱfunctionsȱthatȱbecomeȱavailableȱwhenȱ youȱenterȱtheȱUserȱFunctionsȱmode.ȱTheȱfollowingȱsectionȱlistsȱtheseȱfunctions.ȱȱ Note:ȱAlthoughȱtheseȱfunctionsȱareȱinȱtheȱUserȱFunctionsȱmenu,ȱyouȱcanȱaskȱyouȱinstallerȱtoȱprogramȱsomeȱ ofȱthemȱforȱyou.ȱ ToȱenterȱtheȱUserȱFunctionsȱmodeȱpressȱ ȱfollowedȱbyȱyourȱuserȱcode.ȱȱ TheȱfollowingȱtableȱshowsȱfullȱKeypadȱOperationsȱaccordingȱtoȱusers.ȱ ȱ džȱȱȱȬȱUserȱisȱableȱtoȱperformȱthisȱfunctionȱ ȬȱȱȱȬȱUserȱisȱunableȱtoȱperformȱorȱseeȱthisȱfunctionȱ Operation Grand Master User Installer džȱ džȱ Ȭȱ MainȱBuzzerȱON/OFF:ȱUsedȱtoȱcontrolȱtheȱmainȱ unitȱbuzzer.ȱ džȱ džȱ džȱ WalkȱTest:ȱUsedȱtoȱeasilyȱtestȱandȱevaluateȱtheȱ operationȱofȱselectedȱzonesȱinȱyourȱsystemȱ džȱ Ȭȱ džȱ OutputȱControl:ȱAllowsȱuserȱcontrolȱofȱpreviouslyȱ designatedȱexternalȱdevicesȱ(e.g.ȱanȱappliance,ȱaȱ motorȬdrivenȱgarageȱdoor,ȱetc.)ȱ OutputȱControlȱÆȱSelectȱOutputÆDefineȱ[Y]ȱ džȱ džȱ Ȭȱ BypassȱTroubles:ȱUsedȱtoȱconfirmȱallȱtroublesȱinȱtheȱ systemȱinȱorderȱtoȱenableȱarmingȱoperation.ȱȱ džȱ džȱ Ȭȱ AntiȱCode:ȱIfȱdefinedȱbyȱyourȱengineerȱtheȱAgilityȱ canȱbeȱdefinedȱtoȱbeȱnotȱreadyȱtoȱArmȱafterȱanȱ alarmȱorȱtamperȱcondition.ȱToȱrestoreȱtheȱsystemȱtoȱ Normal Operationȱmode,ȱinstallerȱcodeȱorȱanȱAntiȬ codeȱmustȱbeȱentered.ȱEnteringȱtheȱcodeȱsuppliedȱ byȱtheȱinstallerȱatȱthisȱlocationȱwillȱrestoreȱtheȱ systemȱtoȱtheȱNormal Operationȱmodeȱ džȱ džȱ Ȭȱ Activitiesȱ BypassȱZone:ȱProvidesȱtheȱabilityȱtoȱbypassȱanyȱofȱ theȱsystemȇsȱintrusionȱzones.ȱ BypassȱzoneȱÆȱSelectȱzoneȱÆȱDefineȱ[Y]ȱusingȱtheȱ ȱkeyȱandȱpressȱ usingȱtheȱ ȱȱ ȱkeyȱandȱpressȱ ȱ Page 30 AgilityȱUserȱManualȱ ȱ Operation Grand Master User Installer AdvancedȱÆȱPrepaidȱSIMȱÆȱCheckȱCreditȱ UseȱthisȱfunctionȱtoȱreceiveȱinformationȱbyȱSMSȱorȱ VoiceȱofȱtheȱcreditȱlevelȱinȱyourȱprepaidȱSIMȱcard.ȱ Forȱmoreȱinformationȱreferȱtoȱyourȱinstaller.ȱ džȱ Ȭȱ Ȭȱ AdvancedȱÆȱPrepaidȱSIMȱÆȱResetȱSIMȱ AfterȱchargingȱaȱprepaidȱSIMȱcard,ȱtheȱuserȱhasȱtoȱ resetȱtheȱSIMȱExpireȱTimeȱmanually.ȱTheȱtimeȱ durationȱforȱexpirationȱisȱdefinedȱbyȱyourȱinstaller.ȱ džȱ Ȭȱ Ȭȱ AdvancedȱÆȱRestoreȱAlarm:ȱTheȱuserȱmustȱapproveȱ anȱalarmȱthatȱoccurredȱinȱtheȱsystem.ȱAfterȱ disarmingȱanȱalarm,ȱanȱAlarmȱMemoryȱDisplayȱwillȱ appearȱonȱtheȱscreen.ȱȱ džȱ džȱ Ȭȱ AdvancedȱÆȱRestoreȱTrouble:ȱIfȱdefinedȱbyȱyourȱ installer,ȱuseȱthisȱoptionȱtoȱresetȱaȱtroubleȱconditionȱ afterȱitȱhasȱbeenȱcorrected.ȱȱȱ džȱ džȱ Ȭȱ AdvancedȱÆȱSirenȱTMPȱMute:ȱUsedȱtoȱsilenceȱanȱ alarmȱinitiatedȱbyȱaȱtamperȱfromȱaȱsirenȱforȱ20ȱ minutes.ȱUseȱthisȱoptionȱwhenȱreplacingȱtheȱsirenȱ battery.ȱȱ džȱ Ȭȱ džȱ AdvancedȱÆȱViewȱIPȱAddress:ȱUseȱthisȱoptionȱtoȱ viewȱtheȱIPȱaddressȱofȱtheȱAgility.ȱ džȱ Ȭȱ Ȭȱ AdvancedȱÆȱCSȱConnect:ȱEnablesȱtoȱestablishȱ communicationȱwithȱtheȱconfigurationȱsoftwareȱatȱaȱ predefinedȱlocationȱthroughȱIPȱorȱGPRS.ȱ džȱ Ȭȱ džȱ AdvancedȱÆȱExit/EntryȱBeeps:ȱEnablesȱtoȱcontrolȱ theȱexit/entryȱbeepsȱofȱtheȱcurrentȱkeypad. džȱ Ȭȱ džȱ Define:ȱUsedȱtoȱdefineȱFollowȱMeȱdestinationsȱ phoneȱnumberȱorȱEmailȱaddressȱaccordingȱtoȱitsȱ type:ȱVoiceȱmessage,ȱSMSȱorȱEȬmailȱ džȱ Ȭȱ džȱ TestȱFM:ȱUsedȱtoȱtestȱFollowȱMeȱreporting.ȱ džȱ Ȭȱ džȱ džȱ džȱ Ȭȱ FollowȱMeȱȱ Codes/Tagsȱ Useȱthisȱmenuȱtoȱsetȱtagsȱandȱuserȱcodesȱinȱtheȱ system.ȱForȱdetailedȱinformationȱreferȱtoȱChapterȱ4,ȱ pageȱ23.ȱȱ Page 31 ȱ AgilityȱUserȱManualȱ Operation Grand Master User Installer Timeȱ&ȱDate:ȱAllowsȱtheȱsettingȱofȱtheȱsystemȱtimeȱ andȱdate.ȱThisȱdefinitionȱisȱrequiredȱforȱsettingȱtheȱ schedulerȱprogrammingȱinȱtheȱsystem.ȱ džȱ Ȭȱ džȱ Scheduler:ȱEnablesȱyouȱtoȱactivateȱorȱdeactivateȱ preprogrammedȱschedulesȱthatȱwereȱdefinedȱbyȱ yourȱinstaller.ȱUpȱtoȱ8ȱweeklyȱprogramsȱcanȱbeȱ definedȱinȱtheȱsystemȱduringȱwhichȱtheȱsystemȱ automaticallyȱarmsȱ/ȱdisarmsȱorȱactivatesȱutilityȱ outputs.ȱȱ džȱ Ȭȱ džȱ Clockȱ EventȱLogȱ ȱ ȱ ȱ ȱToȱviewȱaȱlistȱofȱsystemȱeventsȱthatȱhaveȱoccurredȱ džȱ Ȭȱ džȱ ServiceȱInformationȱȱ ȱ ȱ ȱ Allowsȱtheȱdisplayȱofȱanyȱpreviouslyȱenteredȱ serviceȱinformation.ȱ(Nameȱandȱphone)ȱȱ džȱ džȱ Ȭȱ Macroȱȱ ȱ ȱ ȱ AgilityȱenablesȱtheȱinstallerȱorȱGMȱtoȱrecordȱaȱseriesȱ ofȱcommandsȱandȱassignȱthemȱtoȱaȱmacro.ȱForȱmoreȱ informationȱreferȱtoȱsectionȱ4.5ȱMacroȱkeysȱpageȱ28.ȱ džȱ Ȭȱ džȱ ȱȱ ȱ Page 32 AgilityȱUserȱManualȱ ȱ Chapter 5 - System Specifications TheȱfollowingȱtechnicalȱspecificationsȱareȱapplicableȱforȱtheȱAgility:ȱȱ Electrical Characteristics SystemȱPower 230VACȱ(Ȭ15%+10%),ȱ50Hz,ȱ50mA Optional:ȱ9VAC,ȱ50Ȭ60Hz UnitsȱConsumptionsȱȱ Mainȱboard:ȱTypicalȱ130mAȱ GSM:ȱStandȱbyȱ35mA,ȱCommunicationȱ300mAȱ Modem:ȱStandȱbyȱ20mA,ȱCommunicationȱ60mAȱȱ IPȱCard:ȱ90mAȱ(Max)ȱ BackupȱBattery SealedȱLeadȱAcidȱBatteryȱ6Vȱ3.2Ahȱ BatteryȱDimensionsȱ(HxWxD) 67mmȱxȱ134mmȱxȱ34mmȱ InternalȱSirenȱintensity 90ȱdBAȱ@ȱ1m OperatingȱTemperature Ȭ10qCȱtoȱ40qCȱ(14qFȱtoȱ104qF)ȱ Storageȱtemperatureȱ Ȭ20°Cȱtoȱ60°Cȱ(Ȭ4°Fȱtoȱ140°F)ȱ Physical Characteristics Dimensionȱ(HxWxD) 268.5ȱmmȱxȱ219.5ȱmmȱxȱ64ȱmmȱȱ (10.57ȱxȱ8.64ȱxȱ2.52ȱinch) Weightȱ(Withoutȱbattery) 1.31Kgȱ(Fullȱconfiguration) Wireless Characteristics RFȱimmunity AccordingȱtoȱENȱ50130Ȭ4 Frequency 868.65ȱMHzȱorȱ433.92ȱMHzȱ Page 33 ȱ AgilityȱUserȱManualȱ Chapter 6 - EN 50131 Compliance Compliance Statement Hereby,ȱRISCOȱGroupȱdeclaresȱthatȱtheȱAgilityȱseriesȱofȱcentralȱunitsȱandȱaccessoriesȱareȱ designedȱtoȱcomplyȱwith:ȱ EN50131Ȭ1,ȱEN50131Ȭ3ȱGradeȱ2ȱ EN50130Ȭ5ȱEnvironmentalȱclassȱIIȱȱ EN50131Ȭ6ȱTypeȱAȱ UK:ȱPDȱ6662:2004,ȱACPOȱDD243:2004ȱ(Police)ȱȱȱ Possible logical keys calculations: Logicalȱcodesȱareȱcodesȱtypedȱinȱtheȱwirelessȱkeypadȱtoȱallowȱlevelȱ2ȱ(users)ȱandȱ levelȱ3ȱ(installer)ȱaccessȱ Allȱcodeȱlengthsȱareȱ4ȱdigitsȱlongȱ 0Ȭ9ȱcanȱbeȱusedȱforȱeachȱdigitȱ Thereȱareȱnoȱdisallowedȱcodes,ȱallȱcodesȱfromȱ0001ȱtoȱ9999ȱareȱacceptableȱ Invalidȱcodesȱcannotȱbeȱcreatedȱsinceȱafterȱ4ȱdigitsȱhaveȱbeenȱtypedȱȈEnterȈȱisȱ automatic.ȱCodesȱrejectionȱoccursȱonlyȱwhenȱtryingȱtoȱcreateȱaȱcodeȱthatȱdoesȱnotȱ exist.ȱ Possible physical keys calculations: PhysicalȱkeysȱareȱimplementedȱinȱtheȱWirelessȱRemoteȱControls.ȱ Itȱisȱassumedȱonlyȱaȱuserȱcanȱhaveȱremoteȱcontrols,ȱsoȱhavingȱaȱphysicalȱkeyȱisȱ consideredȱasȱaccessȱlevelȱ2ȱ Eachȱremoteȱcontrolȱhasȱanȱidentificationȱcodeȱofȱ24ȱbit,ȱsoȱtheȱnumberȱofȱoptionsȱisȱ 2^24ȱ ForȱaȱremoteȱcontrolȱtoȱoperateȱwithȱtheȱAgility,ȱaȱȈwriteȈȱprocessȱmustȱbeȱmadeȱ afterȱwhichȱtheȱkeypadȱisȱregisteredȱwithȱtheȱpanel.ȱ AȱvalidȱremoteȱcontrolȱisȱoneȱȈLearnedȈȱbyȱtheȱpanelȱandȱallowsȱArm/Disarmȱ AȱnonȱvalidȱremoteȱcontrolȱisȱoneȱnotȱȈLearnedȈȱbyȱtheȱpanelȱandȱdoesȱnotȱallowȱ Arm/Disarmȱ Page 34 AgilityȱUserȱManualȱ ȱ Appendix A - Keypad User Operations Theȱfollowingȱsectionȱdetailsȱtheȱuserȱoperationsȱfromȱtheȱ2Ȭwayȱwirelessȱkeypad.ȱUserȱ operationȱcanȱbeȱdefinedȱtoȱbeȱactivatedȱbyȱaȱquickȱmodeȱorȱhighȱsecurityȱmodeȱthatȱ requiresȱtheȱuseȱofȱaȱcodeȱorȱproximityȱtag.ȱ Inȱtheȱhighȱsecurityȱmodeȱtheȱproximityȱtagȱcanȱbeȱusedȱasȱaȱsubstituteȱforȱinsertingȱaȱuserȱ codeȱwhenȱtheȱdisplayȱpromptsȱtoȱȈInsertȱaȱcodeȈ.ȱȱ Common Operations Operation Quick Operation High Security Mode 1 AwayȱArmȱ Pressȱ ȱ Pressȱ ȱfollowedȱbyȱcodeȱorȱproximityȱtagȱ2ȱ Pressȱ ȱ Press ȱfollowedȱbyȱcodeȱorȱproximityȱtagȱ StayȱArmȱ3ȱ ȱ FullȱDisarmȱ ȱfollowedȱbyȱcodeȱorȱproximityȱtagȱ Pressȱ 1. Consultȱyourȱinstallerȱforȱtheȱoperationsȱdefinedȱwithȱaȱcodeȱ 2. Forȱoptimalȱuseȱofȱtheȱproximityȱtag,ȱuseȱitȱfromȱaȱdistanceȱofȱ1Ȭ2ȱcmȱ(0.4ȈȱȬȱ0.7Ȉ)ȱfromȱtheȱcenterȱofȱtheȱ keypadȇsȱdoorȱ 3. ForȱStayȱArmingȱwithȱnoȱentryȱdelayȱpressȱtheȱ ȱkeyȱforȱtwoȱsecondsȱ Advanced Operations Operation1 Quick Operation AwayȱArmingȱ Partitionȱ1/2/3ȱ Selectȱpartitionȱ / / High Security Mode Selectȱpartitionȱ andȱpressȱ ȱ StayȱArmingȱ Partitionȱ1/2/3ȱ Selectȱpartitionȱ / / Panicȱalarmȱ/ȱServiceȱ callȱȱ FireȱAlarmȱ ȱandȱ pressȱȱȱ followedȱbyȱcodeȱorȱ proximityȱtagȱ Selectȱpartitionȱ / / andȱ pressȱȱȱ ȱȱfollowedȱbyȱcodeȱorȱ proximityȱtagȱ / / Selectȱpartitionȱ codeȱorȱtheȱproximityȱtagȱ Pressȱbothȱkeysȱ Pressȱ / andȱpressȱ ȱ Partitionȱ1/2/3ȱȱ Disarmȱȱ / ȱ andȱpressȱȱ ȱȱsimultaneouslyȱ4ȱ ȱsimultaneouslyȱforȱ2ȱsecondsȱ Page 35 ȱfollowedȱbyȱtheȱ ȱ AgilityȱUserȱManualȱ Operation1 Quick Operation Emergency/Medicalȱ Alarmȱ Pressȱ SystemȱChimeȱ On/Offȱ Pressȱtheȱbuttonȱȱ MainȱUnitȱSpeakerȱ Volumeȱ SetȱkeypadȱLCDȱ contrastȱ ȱsimultaneouslyȱforȱ2ȱsecondsȱ Pressȱ ȱtoȱsaveȱyourȱselectionȱ Pressȱ forȱ2ȱsecondsȱ ȱ pressȱ ȱkeysȱtoȱadjustȱtheȱkeypadȇsȱdisplayȱcontrastȱandȱ ȱ Pressȱbuttonȱ / ViewȱLastȱAlarmȱ ȱforȱ2ȱsecondsȱ Pressȱtheȱbuttonȱ ȱforȱ2ȱsecondsȱ Selectȱtheȱvolumeȱlevelȱ(0=Noȱsound,ȱ4=Fullȱvolume)ȱ Useȱtheȱ OutputȱȱControlȱ A/B/Cȱ2ȱ High Security Mode / forȱ2ȱsecondsȱ Holdȱbuttonȱ Pressȱbuttonȱ / / ȱforȱ2ȱ secondsȱfollowedȱbyȱcodeȱorȱ proximityȱtagȱ ȱforȱtwoȱsecondsȱ ViewȱSystemȱStatusȱ OnlyȱLCDȱdisplayȱ:ȱShortȱpressȱonȱȱ Shortȱpressȱonȱȱ displayȱ :ȱLCDȱ Longȱpressȱonȱ displayȱ+ȱvoiceȱ :ȱLCDȱ ȱfollowedȱbyȱcodeȱorȱproximityȱ tagȱ LCDȱdisplayȱ+ȱvoice:ȱLongȱpressȱonȱ ȱfollowedȱbyȱcodeȱorȱproximityȱ tagȱ MacroȱActivationȱ3ȱ WakeȱupȱKeypadȱ / Pressȱȱ / ȱforȱ2ȱsecondsȱ Pressȱ ȱ UpdateȱKeypadȱ Parametersȱ Pressȱ ȱforȱ2ȱsecondsȱafterȱchangingȱparametersȱinȱtheȱsystemȱ EnterȱProgrammingȱ Modeȱ Pressȱ andȱenterȱtheȱcodeȱ ChangingȱKeypadȱ Languageȱ Pressȱ ȱsimultaneouslyȱforȱ2ȱseconds.ȱSelectȱtheȱlanguageȱ andȱpressȱ ȱtoȱconfirm.ȱ ȱ Page 36 AgilityȱUserȱManualȱ ȱ 1. Allȱoperationsȱareȱavailableȱwhileȱkeypadȱisȱturnedȱonȱ(NotȱinȱSleepȱMode)ȱ 2. Askȱyourȱinstallerȱwhetherȱoutputsȱcontrolȱisȱapplicableȱorȱnotȱandȱwhichȱoutputȱisȱassignedȱtoȱwhichȱ keyȱ 3. Askȱyourȱinstallerȱforȱtheȱmacroȱdefinedȱforȱeachȱkeyȱȱ 4. Askȱyourȱinstallerȱforȱtheȱkeysȱdefinitionȱȱ LEDs Indication Key Function Communicationȱwithȱtheȱpanelȱ ȱȱ(Blue)ȱ On:ȱFullyȱorȱpartiallyȱarmedȱ ȱȱ (Red) ȱ Slowȱflash:ȱExitȱdelayȱ Rapidȱflash:ȱAlarmȱ Troubleȱinȱtheȱsystemȱduringȱdisarmȱmodeȱȱ ȱȱȱȱȱ (Yellow) ȱ ȱ Page 37 ȱ AgilityȱUserȱManualȱ Appendix B - Remote Control User Operations TheȱfollowingȱsectionȱdetailsȱtheȱuserȱoperationsȱfromȱtheȱAgilityȱ2ȬWayȱRemoteȱControl.ȱ Userȱoperationȱcanȱbeȱdefinedȱtoȱbeȱactivatedȱbyȱaȱquickȱmodeȱorȱhighȱsecurityȱmodeȱthatȱ requiresȱtheȱuseȱofȱaȱcode.ȱȱȱȱ Common Operations Operation High Security Mode 1 Quick AwayȱArmȱ StayȱArmȱ2ȱȱȱ ȱ ȱ>ȱCodeȱ ȱ ȱ>ȱCodeȱ FullȱDisarmȱ ȱ>ȱCodeȱ ȱ SystemȱStatusȱ3ȱ Longȱ OutputȱȱControlȱ4ȱȱA/B/Cȱ Longȱȱ PanicȱAlarmȱ ClearȱOperationȱ5ȱ 4\? ȱ Longȱ ȱ/ȱ ȱ/ȱ ȱ 4\? ȱ>ȱCodeȱ Longȱȱ ȱ/ȱ ȱ+ȱ ȱsimultaneouslyȱforȱ2ȱsecondsȱ ȱ>ȱ ȱ ȱ/ȱ ȱ>ȱCodeȱ ȱ 1 Consultȱyourȱinstallerȱwhichȱcommandsȱareȱdefinedȱwithȱaȱcode.ȱȱ 2 Pressingȱ 3 4 5 >ȱ ȱwillȱcancelȱtheȱEntryȱDelayȱtime.ȱ 4\? Pressingȱ >ȱ ȱwillȱgiveȱstatusȱindicationȱonlyȱbyȱtheȱLEDȱofȱtheȱremoteȱcontrolȱandȱnotȱbyȱ localȱvoiceȱmessage.ȱ Askȱyourȱinstallerȱwhichȱdeviceȱisȱassignedȱtoȱwhichȱkey.ȱ Useȱthisȱcommandȱtoȱclearȱtheȱremoteȱcontrolȱoperation.ȱȱȱ Advanced Operations Operation AwayȱPartitionȱ1/2/3ȱ Armingȱȱ StayȱPartitionȱ1/2/3ȱ Armingȱ Partionȱ1/2/3ȱDisarmȱȱ Quick Code Sequence ȱ/ȱ ȱ/ȱ ȱ>ȱ ȱ ȱ/ȱ ȱ/ȱ ȱ>ȱ ȱ>ȱCodeȱ ȱ/ȱ ȱ/ȱ >ȱ ȱ ȱ/ȱ ȱ/ȱ ȱ>ȱ ȱCodeȱ ȱ/ȱ ȱ/ȱ ȱ>ȱ ȱ/ȱ ȱ/ȱ ȱ>ȱ ȱ>ȱCodeȱ Page 38 ȱ AgilityȱUserȱManualȱ ȱ Status LED/Buzzer Indications Afterȱeachȱtransmissionȱ(indicatedȱbyȱaȱflashingȱGreenȱLED)ȱfromȱtheȱremoteȱcontrol,ȱtheȱ AgilityȱsendsȱaȱstatusȱresponseȱindicatedȱbyȱtheȱremoteȱcontrolȇsȱLEDsȱandȱBuzzer:ȱ LED Indications Operation 1st LED * (Send command) Greenȱ Greenȱ Greenȱ Greenȱ AwayȱArmȱȱ StayȱArmȱ Disarmȱȱ Alarmȱ 2nd LED (Receive Status) Redȱ Orangeȱ Greenȱ FlashȱRedȱLEDȱ *Ifȱtheȱ1stȱLEDȱchangesȱtoȱorangeȱitȱindicatesȱaȱlowȱbatteryȱcondition.ȱ Buzzer Indications Sound Status 1ȱbeepȱ Confirmationȱ 3ȱbeepsȱ Errorȱ 5ȱbeepsȱ Alarmȱ Changing Remote Control PIN Code EachȱremoteȱcontrolȱcanȱbeȱdefinedȱbyȱyourȱinstallerȱtoȱbeȱactivatedȱwithȱaȱuniqueȱPINȱ code.ȱȱ ToȱchangeȱtheȱremoteȱcontrolȱPINȱcodeȱ(fromȱtheȱremoteȱcontrolȱitself):ȱȱ Note:ȱToȱchangeȱtheȱPINȱcodeȱitȱisȱmandatoryȱtoȱperformȱtheȱfollowingȱprocedureȱinȱcloseȱproximityȱtoȱtheȱ controlȱpanel.ȱ 4\? 1. 2. Pressȱtheȱ +ȱ ȱsimultaneouslyȱforȱ2ȱseconds.ȱ Enterȱtheȱremoteȱcontrolȱcurrentȱ4ȱdigitȱPINȱcode.ȱ 3. Press ȱfollowedȱbyȱaȱnewȱ4ȱdigitȱcode.ȱȱ .ȱ 4. Press Theȱpanelȱwillȱsendȱaȱconfirmationȱmessage.ȱTheȱremoteȱcontrolȱwillȱsoundȱaȱlongȱbeepȱ andȱtheȱGreenȱLEDȱwillȱturnȱon.ȱIfȱnoȱconfirmationȱsoundȱisȱheardȱtheȱoldȱPINȱcodeȱwillȱ remain.ȱRepeatȱtheȱprocedureȱagainȱtoȱreplaceȱtoȱaȱnewȱcode.ȱ ȱ ȱ Page 39 ȱ AgilityȱUserȱManualȱ Appendix C - Event Log Messages EventȱMessageȱ ActivateȱUO=xxȱȱȱ ActvȱUO=xxȱKF=zzȱ AlarmȱabortȱP=yȱȱ Descriptionȱ UOȱXXȱactivationȱ UOȱXXȱisȱactivatedȱfromȱremoteȱcontrolȱZZȱ AlarmȱabortedȱonȱpartitionȱYȱ AlarmȱZone=xxȱȱȱȱ AntiȬcodeȱresetȱȱ AutoȱAddȱGSMȱȱȱȱȱ AutoȱAddȱIPȱcardȱ AutoȱAddȱMODEMȱȱȱ AutoȱDelȱGSMȱȱȱȱȱ AutoȱDelȱIPȱcardȱ AutoȱDelȱMODEMȱȱȱ Autoȱtestȱfailȱȱȱ AutoȱtestȱOKȱȱȱȱȱ AwayȱfailȱP=yȱȱȱȱ Away:P=yȱC=zzȱȱȱȱ Alarmȱinȱzoneȱno.ȱXXȱ Remoteȱresetȱ GSMȱModuleȱaddedȱtoȱtheȱmainȱunitȱ IPȱModuleȱaddedȱtoȱtheȱmainȱunitȱ Modemȱaddedȱtoȱtheȱmainȱunitȱ GSMȱModuleȱwasȱremovedȱfromȱtheȱmainȱunitȱ IPȱModuleȱremovedȱfromȱtheȱmainȱunitȱ Modemȱremovedȱfromȱtheȱmainȱunitȱ FailureȱofȱzoneȱselfȬtestȱ AutomaticȱzoneȱselfȬtestȱOKȱ PartitionȱYȱfailedȱtoȱarmȱ PartitionȱYȱarmedȱbyȱuserȱno.ȱZZȱ Away:P=yȱKF=zzȱȱȱ Bellȱtamperȱȱ Bellȱtamperȱrstȱȱ Boxȱtamperȱȱȱȱȱȱȱ Boxȱtamperȱrstȱȱȱ PartitionȱYȱarmedȱbyȱremoteȱcontrolȱZZȱ Bellȱtamperȱalarmȱ Bellȱtamperȱalarmȱrestoreȱ Boxȱtamperȱalarmȱfromȱmainȱunitȱ Boxȱtamperȱalarmȱrestoreȱ BypassȱBox+Bellȱȱ BypassȱTrblȱC=xxȱ BypassȱZone=xxȱȱȱ CancelȱAlarmȱP=xȱ Boxȱ+ȱBellȱtamperȱisȱbypassedȱ SystemȱtroublesȱwereȱbypassedȱbyȱuserȱXXȱ Zoneȱno.ȱXXȱisȱbypassedȱ CancelȱalarmȱeventȱhasȱoccurredȱfromȱpartitionȱX.ȱAȱvalidȱuserȱ functionȱisȱenteredȱtoȱresetȱtheȱalarmȱafterȱtheȱdefinedȱAbortȱalarmȱ timeȱ ChangingȱuserȱcodeȱXXȱ ChangingȱFollowȬMeȱnumberȱYYȱ ChangingȱkeypadȱtagȱforȱuserȱXXȱ Timeȱisȱnotȱsetȱ Timeȱdefinedȱbyȱuserȱno.ȱXXȱ COȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱCOȱdetectorȱ COȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱCOȱdetectorȱ CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱIPȱcardȱ CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱSirenȱYȱ CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱGSMȱ CommunicationȱOKȱbetweenȱtheȱAgilityȱandȱI/Oȱmoduleȱ ConfirmedȱalarmȱoccurredȱinȱpartitionȱYȱ Changeȱcode=xxȱȱȱ ChangeȱFM=yyȱȱȱȱȱ Changeȱtag=xxȱȱȱȱ Clockȱnotȱsetȱȱȱȱ ClockȱsetȱC=xxȱȱȱ COȱAlarmȱZn=xxȱȱȱ COȱRst.ȱZn=xxȱȱȱȱ ComȱokȱIPȱcardȱȱȱ CommȱOKȱSiren=yȱ Comm.ȱOKȱGSMȱȱȱȱȱ Comm.OKȱI/OȱMdl.ȱ Conf.ȱalarmȱP=yȱȱ Page 40 AgilityȱUserȱManualȱ EventȱMessageȱ ConfirmȱrsȱZ=xxȱȱ ConfirmȱZone=xxȱȱ CPȱresetȱȱȱȱȱȱȱȱȱ DateȱsetȱC=xxȱȱȱȱ DayȱAway:P=yȱȱȱȱȱ Dayȱdisarm:P=yȱȱȱ Dayȱstay:ȱP=yȱȱȱȱȱ Disarm:P=yȱC=zzȱȱ Disarm:ȱP=yȱKF=zzȱ DuressȱC=xxȱȱȱȱȱȱ Enterȱprogramȱȱȱȱ ȱ Falseȱcodeȱȱȱȱȱȱȱ Descriptionȱ Restoreȱzoneȱconfirmedȱalarmȱ ConfirmedȱalarmȱoccurredȱfromȱzoneȱXXȱ Theȱcontrolȱpanelȱhasȱresetȱ Dateȱdefinedȱbyȱuserȱno.ȱXXȱ DailyȱarmȱonȱpartitionȱYȱ DailyȱdisarmȱonȱpartitionȱYȱ DailyȱSTAYȱarmingȱinȱpartitionȱYȱ PartitionȱYȱdisarmedȱbyȱuserȱZZȱ PartitionȱYȱdisarmedȱbyȱremoteȱcontrolȱZZȱ Duressȱalarmȱfromȱuser no.ȱXXȱ Enteringȱinstallerȱprogrammingȱfromȱkeypadȱorȱconfigurationȱ softwareȱ ExitȱerrorȱeventȱfromȱzoneȱXXȱ Theȱzoneȱwasȱleftȱopenȱatȱtheȱendȱofȱtheȱexitȱtimeȱ Exitingȱinstallerȱprogrammingȱfromȱkeypadȱorȱconfigurationȱ softwareȱ Falseȱcodeȱalarmȱ Falseȱrestoreȱȱȱȱ FireȱKeypad=yȱȱȱȱ FireȱokȱZone=xxȱȱ FireȱtrblȱZn=xxȱȱ FireȱZone=xxȱȱȱȱȱ FoilȱokȱZ=xxȱȱȱȱȱ Falseȱcodeȱalarmȱrestoreȱ FireȱalarmȱfromȱwirelessȱkeypadȱYȱ Troubleȱrestoreȱinȱfireȱzoneȱno.ȱXXȱ Troubleȱinȱfireȱzoneȱno.ȱXXȱ Fireȱalarmȱinȱzoneȱno.ȱXXȱ Restoreȱinȱfoilȱ(Day)ȱzoneȱno.ȱXXȱ FoilȱZone=xxȱȱȱȱȱ ForcedȱȱP=yȱȱȱȱȱȱ FoundȱZone=xxȱȱȱȱ GasȱAlarmȱZn=xxȱȱ GasȱRst.ȱZn=xxȱȱȱ GSM:ȱModuleȱcomm.ȱ GSM:NETȱavail.ȱȱȱ GSM:NETȱavail.OKȱ GSM:NETȱqual.OKȱȱ GSM:NETȱqualityȱȱ Troubleȱinȱfoilȱ(Day)ȱzoneȱno.ȱXXȱ PartitionȱYȱisȱforceȱarmedȱ Wirelessȱzoneȱfound,ȱzoneȱno.ȱXXȱ Gasȱ(naturalȱgas)ȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱgasȱdetectorȱ Gasȱ(naturalȱgas)ȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱgasȱ detectorȱ IPȱconnectionȱOKȱ IPȱaddressȱisȱincorrectȱ CommunicationȱbetweenȱtheȱGSM/GPRSȱModuleȱandȱtheȱAgilityȱisȱ OKȱ InternalȱGSM/GPRSȱBUSȱmoduleȱtroubleȱ GSMȱnetworkȱisȱnotȱavailableȱ GSMȱNetworkȱisȱavailableȱ GSMȱNetworkȱqualityȱisȱacceptableȱ TheȱGSMȱRSSIȱlevelȱisȱlowȱ GSM:PINȱcodeȱerrȱ GSM:PINȱcodeȱOKȱȱ GSM:PUKȱCodeȱerrȱ PINȱcodeȱenteredȱisȱincorrectȱ PINȱcodeȱisȱcorrectȱ PUKȱcodeȱrequiredȱ ExitȱErrorȱZn=xxȱ Exitȱprogramȱȱȱȱȱ GSM:IPȱOKȱȱȱȱȱȱȱȱ GSM:IPȱTroubleȱȱȱ GSM:Mdlȱcomm.OKȱȱ Page 41 ȱ EventȱMessageȱ GSM:PUKȱCodeȱOKȱȱ GSM:SIMȱOKȱȱȱȱȱȱȱ GSM:SIMȱtroubleȱȱ H.TempȱrstȱZn=xxȱ AgilityȱUserȱManualȱ IPC:DHCPȱerrorȱȱȱ IPC:DHCPȱokȱȱȱȱȱȱ Descriptionȱ PUKȱCodeȱenteredȱisȱcorrect SIMȱCardȱinȱplaceȱ SIMȱcardȱmissingȱorȱnotȱproperlyȱsitedȱ HighȱtemperatureȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱ temperatureȱdetectorȱ HighȱtemperatureȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱtemperatureȱ detectorȱ ACȱpowerȱrestoreȱonȱI/Oȱmoduleȱ ACȱpowerȱtroubleȱonȱI/Oȱmoduleȱ I/Oȱmoduleȱbatteryȱtroubleȱrestoredȱȱ I/Oȱmoduleȱbatteryȱtroubleȱalertȱ I/Oȱmoduleȱjammingȱalertȱ I/Oȱmoduleȱjammingȱalertȱrestoredȱ I/Oȱmoduleȱisȱregardedȱasȱlostȱfollowingȱsupervisionȱtestȱ I/Oȱmoduleȱtamperȱalertȱ I/Oȱmoduleȱtamperȱalertȱrestoredȱ TheȱAgilityȱreceivedȱaȱsignalȱfromȱI/Oȱmoduleȱafterȱitȱhasȱbeenȱ regardedȱasȱlostȱ FailedȱtoȱacquireȱanȱIPȱaddressȱfromȱtheȱDHCPȱserverȱ SucceededȱtoȱacquireȱanȱIPȱaddressȱfromȱtheȱDHCPȱserverȱ IPC:ȱNetworkȱerrȱȱ IPC:ȱNetworkȱokȱȱȱ IPC:NTPȱerrorȱȱȱȱ IPC:NTPȱokȱȱȱȱȱȱȱ JammingȱOKȱZn=xxȱ Jammingȱrestoreȱȱ FailedȱtoȱconnectȱtoȱIPȱnetworkȱ SuccessfulȱconnectionȱtoȱIPȱnetworkȱ Failedȱtoȱacquireȱtimeȱdataȱfromȱtheȱtimeȱserverȱ Succeededȱtoȱacquireȱtimeȱdataȱfromȱtheȱtimeȱserverȱ ZoneȱXXȱjammingȱOKȱ Wirelessȱreceiverȱȱjammingȱrestoreȱ JammingȱZ=xxȱȱȱȱȱ KP=yȱLowȱBat.Rstȱ KP=yȱLowȱBatteryȱ Kswȱaway:P=yȱȱȱȱȱ Kswȱdisarm:P=yȱȱȱ L.batȱrstrȱKF=yyȱ L.TempȱrstȱZn=xxȱ ZoneȱXXȱjammingȱtroubleȱ LowȱbatteryȱtroubleȱrestoredȱfromȱkeypadȱYȱ LowȱbatteryȱtroubleȱfromȱkeypadȱYȱ PartitionȱYȱisȱarmedȱbyȱkeyȱswitchȱ PartitionȱYȱisȱdisarmedȱbyȱkeyȱswitchȱ LowȱbatteryȱtroubleȱrestoreȱfromȱwirelessȱremoteȱcontrolȱYYȱ LowȱtemperatureȱalertȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱaȱ temperatureȱdetectorȱ Wirelessȱzoneȱlost,ȱzoneȱno.ȱXXȱ Lowȱbatteryȱtroubleȱrestoredȱfromȱwirelessȱzoneȱno.ȱXXȱ Lowȱbatteryȱtroubleȱfromȱwirelessȱzoneȱno.ȱXXȱ LowȱbatteryȱtroubleȱfromȱwirelessȱremoteȱcontrolȱXXȱ LowȱtemperatureȱalertȱfromȱzoneȱXXȱdefinedȱasȱaȱtemperatureȱ detectorȱ ACȱpowerȱrestoreȱonȱmainȱpanelȱ HighȱTemp.ȱZn=xxȱ I/O:ACȱRstrȱȱȱȱȱȱ I/O:ACȱTroubleȱȱȱ I/O:ȱBatteryȱRstrȱ I/O:ȱBatteryȱTrblȱ I/O:ȱJammingȱȱȱȱȱȱ I/O:ȱJammingȱRstrȱ I/O:ȱLostȱȱȱȱȱȱȱȱȱ I/O:ȱTamperȱȱȱȱȱȱȱ I/O:ȱTamperȱRstrȱȱ IO:ȱLostȱRestoreȱȱ LostȱZone=xxȱȱȱȱȱ LowȱBatȱrsȱZ=xxȱȱ Lowȱbat.ȱZn=xxȱȱȱ Lowȱbat.KF=yyȱȱȱȱ LowȱTemp.ȱZn=xxȱȱ Main:ACȱrestoreȱȱ Page 42 AgilityȱUserȱManualȱ ȱ EventȱMessageȱ Main:ȱBatteryȱrstȱ Descriptionȱ Lowȱbatteryȱtroubleȱrestoreȱfromȱtheȱmainȱpanelȱ Main:ȱLowȱACȱȱȱȱȱȱ Main:ȱLowȱbatteryȱ MS=yȱcallȱerrorȱȱ MS=yȱrestoreȱȱȱȱȱ MsgȱBoxȱTamperȱ MsgȱBoxȱTmpȱRst.ȱ NoȱComȱIPȱcardȱȱȱ NoȱcommȱI/OȱMdl.ȱ NoȱcommȱSiren=yȱȱ Noȱcomm.ȱGSMȱȱȱȱȱ Phoneȱfailȱȱȱȱȱȱȱ Phoneȱrestoreȱȱȱȱ PoliceȱKeypad=yȱȱ PoliceȱKF=yyȱȱȱȱȱ PTM:ȱSendȱDataȱȱȱȱ Radioȱl.batȱȱS=yȱ Radioȱl.batȱrS=yȱ Remoteȱaway:P=yȱȱ Remoteȱprogramȱȱȱ Remoteȱstay:P=yȱȱ SoakȱfailȱZ=xxȱȱȱ SpecialȱKP=yȱȱȱȱȱ Spkrȱl.batȱrsS=yȱ SpkrȱlowȱbatȱS=yȱ StartȱexitȱP=yȱȱȱ Stay:P=yȱC=zzȱȱȱȱ Stay:ȱP=yȱKF=zzȱȱȱ TamperȱI/OȱMdl.ȱȱ TamperȱI/OȱMdl.ȱȱȱ LossȱofȱACȱpowerȱfromȱtheȱmainȱpanelȱ Lowȱbatteryȱtroubleȱfromȱtheȱmainȱpanelȱ CommunicationȱfailȱtroubleȱtoȱMSȱphoneȱno.ȱYȱ CommunicationȱfailȱtroubleȱrestoreȱtoȱMSȱphoneȱno.ȱYȱ TamperȱalarmȱfromȱtheȱListenȱInȱmessageȱboxȱunitȱ TamperȱalarmȱrestoreȱfromȱtheȱListenȱInȱmessageȱboxȱunitȱ CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱIPȱcardȱ CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱI/Oȱmoduleȱ CommunicationȱfailureȱbetweenȱtheȱAgilityȱandȱsirenȱYȱ NoȱcommunicationȱbetweenȱtheȱGSM/GPRSȱModuleȱandȱtheȱAgilityȱ IfȱtheȱphoneȱlineȱisȱcutȱorȱtheȱDCȱlevelȱisȱunderȱ1Vȱ Phoneȱlineȱtroubleȱrestoreȱ Policeȱ(panic)ȱalarmȱfromȱwirelessȱkeypadȱYȱȱ Policeȱ(panic)ȱalarmȱfromȱremoteȱcontrolȱYYȱ LoadȱnewȱparametersȱintoȱtheȱAgilityȱfromȱPTMȱaccessoryȱȱ RadioȱlowȱbatteryȱtroubleȱfromȱsirenȱYȱ RadioȱlowȱbatteryȱrestoreȱfromȱsirenȱYȱ Theȱsystemȱhasȱbeenȱarmedȱfromȱtheȱconfigurationȱsoftwareȱ Theȱsystemȱhasȱbeenȱprogrammedȱfromȱtheȱconfigurationȱsoftwareȱ TheȱsystemȱhasȱbeenȱarmedȱinȱSTAYȱmodeȱfromȱtheȱconfigurationȱ softwareȱ Alarmȱrestoreȱinȱzoneȱno.ȱXXȱ Wirelessȱreceiverȱjammingȱ PartitionȱYȱdisarmedȱfromȱtheȱconfigurationȱsoftwareȱ SirenȱYȱisȱregardedȱasȱlostȱfollowingȱsupervisionȱtestȱ TheȱAgilityȱreceivedȱaȱsignalȱfromȱsirenȱYȱafterȱitȱhasȱbeenȱregardedȱ asȱlostȱ ZoneȱXXȱhasȱfailedȱinȱtheȱsoakȱtestȱ SpecialȱalarmȱfromȱtheȱfromȱwirelessȱkeypadȱYȱȱ ȱSpeakerȱlowȱbatteryȱrestoreȱfromȱsirenȱYȱ SpeakerȱlowȱbatteryȱtroubleȱfromȱsirenȱYȱ ExitȱtimeȱstartedȱinȱpartitionȱYȱ PartitionȱYȱstayȱarmedȱbyȱuserȱZZȱ PartitionȱYȱstayȱarmedȱbyȱremoteȱcontrolȱZZȱ TamperȱalarmȱfromȱI/Oȱmoduleȱ TamperȱalarmȱrestoredȱfromȱI/Oȱmoduleȱ TamperȱKeypad=yȱȱ TamperȱrsȱZn=xxȱȱ TamperȱrstȱKP=yȱȱ TamperȱSiren=yȱȱȱ TamperȱalarmȱfromȱkeypadȱID=Yȱ Tamperȱalarmȱrestoreȱonȱzoneȱno.ȱXXȱ KeypadȱYȱtamperȱrestoreȱ TamperȱalarmȱfromȱwirelessȱsirenȱYȱ RestoreȱZone=xxȱȱ RFȱJammingȱȱȱȱȱȱȱ Rmtȱdisarm:P=yȱȱȱ Siren=yȱLostȱȱȱȱȱ Siren=yȱLostȱRstȱ Page 43 ȱ EventȱMessageȱ TamperȱZone=xxȱȱȱ TechȱalarmȱZn=xxȱ TechȱrstrȱȱZn=xxȱ TmpȱrstrȱSiren=yȱ UnbypȱBox+Bellȱȱȱ UnbypassȱZone=xxȱ Unknownȱeventȱȱȱȱ UserȱloginȱC=xxȱȱ WaterȱAlrmȱZn=xxȱ WaterȱrstrȱZn=xxȱ Z=xxȱautoȱbadȱȱȱȱ Z=xxȱautoȱokȱȱȱȱȱ Zn=xxȱTroubleȱ Zn=xxȱTroubleȱOKȱ AgilityȱUserȱManualȱ Descriptionȱ Tamperȱalarmȱfromȱzoneȱno.ȱXXȱ AlarmȱfromȱzoneȱXXȱdefinedȱasȱTechnicalȱ AlarmȱrestoredȱfromȱzoneȱXXȱdefinedȱasȱTechnicalȱ TamperȱalarmȱrestoreȱfromȱwirelessȱsirenȱYȱ Boxȱ+ȱBellȱreinstatedȱfromȱbypassȱ Zoneȱno.ȱXXȱisȱreinstatedȱfromȱbypassȱ Unknownȱeventȱalertȱ UserȱXXȱhasȱenteredȱintoȱprogrammingȱmode.ȱUserȱ99ȱrepresentsȱ remoteȱprogrammingȱfromȱtheȱconfigurationȱsoftwareȱ Floodȱalarmȱfromȱzoneȱno.ȱXXȱ Floodȱalarmȱrestoreȱonȱzoneȱno.ȱXXȱ ZoneȱselfȬtestȱfailed,ȱzoneȱno.ȱXXȱ ZoneȱselfȬtestȱOK,ȱzoneȱno.ȱXXȱ ZoneȱtroubleȱeventȱfromȱzoneȱXXȱ ZoneȱtroubleȱeventȱrestoreȱfromȱzoneȱXXȱ ȱ Page 44 AgilityȱUserȱManualȱ ȱ Notes ȱ AgilityȱUserȱManualȱ Notes ȱ ȱ FCCȱNote:ȱ ThisȱequipmentȱhasȱbeenȱtestedȱandȱfoundȱtoȱcomplyȱwithȱtheȱlimitsȱforȱaȱClassȱBȱ digitalȱdevice,ȱpursuantȱtoȱPartȱ15ȱofȱtheȱFCCȱrules.ȱȱTheseȱlimitsȱareȱdesignedȱtoȱ provideȱreasonableȱprotectionȱagainstȱharmfulȱinterferenceȱinȱaȱresidentialȱinstallation.ȱȱ Thisȱequipmentȱgenerates,ȱusesȱandȱcanȱradiateȱradioȱfrequencyȱenergyȱand,ȱifȱnotȱ installedȱandȱusedȱinȱaccordanceȱwithȱtheȱinstructions,ȱmayȱcauseȱharmfulȱinterferenceȱ toȱradioȱcommunications.ȱȱHowever,ȱthereȱisȱnoȱguaranteeȱthatȱinterferenceȱwillȱnotȱ occurȱinȱaȱparticularȱinstallation.ȱȱIfȱthisȱequipmentȱdoesȱcauseȱharmfulȱinterferenceȱtoȱ radioȱorȱtelevisionȱreception,ȱwhichȱcanȱbeȱdeterminedȱbyȱturningȱtheȱequipmentȱoffȱ andȱon,ȱtheȱuserȱisȱencouragedȱtoȱtryȱtoȱcorrectȱtheȱinterferenceȱbyȱoneȱorȱmoreȱofȱtheȱ followingȱmeasures:ȱ a)ȱȱReorientȱorȱrelocateȱtheȱreceivingȱantenna.ȱ b)ȱȱIncreaseȱtheȱseparationȱbetweenȱtheȱequipmentȱandȱreceiver.ȱ c)ȱȱConnectȱtheȱequipmentȱtoȱanȱoutletȱonȱaȱcircuitȱdifferentȱfromȱthatȱtoȱ whichȱtheȱreceiverȱisȱconnected.ȱ d)ȱConsultȱtheȱdealerȱorȱanȱexperiencedȱradio/TVȱtechnician.ȱ ȱ FCCȱWarning:ȱ TheȱmanufacturerȱisȱnotȱresponsibleȱforȱanyȱradioȱorȱTVȱinterferenceȱcausedȱbyȱ unauthorizedȱmodificationsȱtoȱthisȱequipment.ȱSuchȱmodificationsȱcouldȱvoidȱtheȱuserȇsȱ authorityȱtoȱoperateȱtheȱequipment.ȱ ȱ FCCȱID:ȱJE4AGILITYȱValidȱforȱP/NȱRW132V441ENAȱ IC:ȱ6564AȬAGILITYȱValidȱforȱP/NȱRW132V441ENAȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ RISCO Group Limited Warranty RISCOȱGroupȱandȱitsȱsubsidiariesȱandȱaffiliatesȱ(ȈSellerȈ)ȱwarrantsȱitsȱproductsȱtoȱbeȱfreeȱ fromȱdefectsȱinȱmaterialsȱandȱworkmanshipȱunderȱnormalȱuseȱforȱ24ȱmonthsȱfromȱtheȱdateȱ ofȱproduction.ȱBecauseȱSellerȱdoesȱnotȱinstallȱorȱconnectȱtheȱproductȱandȱbecauseȱtheȱ productȱmayȱbeȱusedȱinȱconjunctionȱwithȱproductsȱnotȱmanufacturedȱbyȱtheȱSeller,ȱSellerȱ cannotȱguaranteeȱtheȱperformanceȱofȱtheȱsecurityȱsystemȱwhichȱusesȱthisȱproduct.ȱSellerȇsȱ obligationȱandȱliabilityȱunderȱthisȱwarrantyȱisȱexpresslyȱlimitedȱtoȱrepairingȱandȱreplacing,ȱ atȱSellerȇsȱoption,ȱwithinȱaȱreasonableȱtimeȱafterȱtheȱdateȱofȱdelivery,ȱanyȱproductȱnotȱ meetingȱtheȱspecifications.ȱSellerȱmakesȱnoȱotherȱwarranty,ȱexpressedȱorȱimplied,ȱandȱ makesȱnoȱwarrantyȱofȱmerchantabilityȱorȱofȱfitnessȱforȱanyȱparticularȱpurpose.ȱ Inȱnoȱcaseȱshallȱsellerȱbeȱliableȱforȱanyȱconsequentialȱorȱincidentalȱdamagesȱforȱbreachȱofȱ thisȱorȱanyȱotherȱwarranty,ȱexpressedȱorȱimplied,ȱorȱuponȱanyȱotherȱbasisȱofȱliabilityȱ whatsoever.ȱ Sellerȇsȱobligationȱunderȱthisȱwarrantyȱshallȱnotȱincludeȱanyȱtransportationȱchargesȱorȱcostsȱ ofȱinstallationȱorȱanyȱliabilityȱforȱdirect,ȱindirect,ȱorȱconsequentialȱdamagesȱorȱdelay.ȱ Sellerȱdoesȱnotȱrepresentȱthatȱitsȱproductȱmayȱnotȱbeȱcompromisedȱorȱcircumvented;ȱthatȱ theȱproductȱwillȱpreventȱanyȱpersonalȱinjuryȱorȱpropertyȱlossȱbyȱburglary,ȱrobbery,ȱfireȱorȱ otherwise;ȱorȱthatȱtheȱproductȱwillȱinȱallȱcasesȱprovideȱadequateȱwarningȱorȱprotection.ȱ Buyerȱunderstandsȱthatȱaȱproperlyȱinstalledȱandȱmaintainedȱalarmȱmayȱonlyȱreduceȱtheȱriskȱ ofȱburglary,ȱrobberyȱorȱfireȱwithoutȱwarning,ȱbutȱisȱnotȱinsuranceȱorȱaȱguarantyȱthatȱsuchȱ eventȱwillȱnotȱoccurȱorȱthatȱthereȱwillȱbeȱnoȱpersonalȱinjuryȱorȱpropertyȱlossȱasȱaȱresultȱ thereof.ȱ Consequentlyȱsellerȱshallȱhaveȱnoȱliabilityȱforȱanyȱpersonalȱinjury,ȱpropertyȱdamageȱorȱlossȱ basedȱonȱaȱclaimȱthatȱtheȱproductȱfailsȱtoȱgiveȱwarning.ȱHowever,ȱifȱsellerȱisȱheldȱliable,ȱ whetherȱdirectlyȱorȱindirectly,ȱforȱanyȱlossȱorȱdamageȱarisingȱunderȱthisȱlimitedȱwarrantyȱorȱ otherwise,ȱregardlessȱofȱcauseȱorȱorigin,ȱsellerȇsȱmaximumȱliabilityȱshallȱnotȱexceedȱtheȱ purchaseȱpriceȱofȱtheȱproduct,ȱwhichȱshallȱbeȱcompleteȱandȱexclusiveȱremedyȱagainstȱseller.ȱ NoȱemployeeȱorȱrepresentativeȱofȱSellerȱisȱauthorizedȱtoȱchangeȱthisȱwarrantyȱinȱanyȱwayȱ orȱgrantȱanyȱotherȱwarranty.ȱ WARNING:ȱThisȱproductȱshouldȱbeȱtestedȱatȱleastȱonceȱaȱweek.ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ȱ ©ȱRISCOȱGroupȱȱȱ03/10ȱ ȱȱ ȱ ȱ ȱ ȱ Sounders Security Devices Wireless WatchOUT IP Cameras iWAVE PIR/PET Detectors Monitoring Station Glassbreak Detectors Fully Wireless Internal & External Sounders Universal Shock Transmitters/ Detectors Magnetic Contacts GSM/GPRS Main Panel Remote Configuration Software Safety Devices Video Verification IP/GSM Receiver Software User Monitoring Smoke Detectors Flood Detectors Gas Detectors CO Detectors IP/Internet Keypads, Keyfobs, Panic 2-Way Remote Control Button Keyfobs Wristband Panic Transmitter Web Browser Management Home Automation Voice Messages Email Notification PSTN/Dial-Up Input/Output & X10 Expander module 5IN1041 E 2-Way Wireless Keypads with proximity tags Video SMS VerificationMessaging © 03/2010 RISCO Group All rights reserved. No part of this document may be reproduced in any form without prior written permission from RISCO Group.