DELTAsingle meter User’s Manual Rev A
Byte
No
Value
Description
Explanation
01
DIF size, 8 bit integer
97-98 2
FF98
Power fail counter
99
1
xx
VIFE, status
100
101
1
1
xx
xF
Power fail counter
DIF this is the last telegram / More data can be
read (monthly values)
102
1
xx
103
1
16
CS checksum, calculated from C field to last
data
Stop character
0000 0001
| | | | ++++- 8 bit integer
| | ++-------- Instantaneous value
| +----------- LSB of storage number
+------------- No DIFE follows
1111 1111
|+++ ++++- VIFE and data is manufacturer specific
+------------- VIFE will follow
1001 1000
|+++ ++++- Power fail counter (decided by ABB)
+------------- VIFE will follow
0xxx xxxx
|+++ ++++- Error code
+------------- No VIFE follows
Number of power fails
000x 1111
| | | | ++++- Special function
| | | +-------- 0 = End of telegram
|||
1 = More data will follow in next telegram
+++--------- [always same]
Checksum on byte no 5 to 101
96
Size
(in
bytes)
1
Error! Style not defined.
2CMC481035D0001
[always same]
Page 40 of 54