Condensing heat exchanger 14 Remove the Condensing heat exchanger by levering it and sliding it forwards. 15 Reassemble the Condensing heat exchanger carrying out the removal operations in reverse order. Ensure to tighten the nuts H - Figure 5.2 firmly. 5.3 Cleaning If there are deposits of dirt on the coil of the Condensing heat exchanger, clean with a bristle paintbrush and remove the dust with a hoover. Warning: After cleaning or replacement as detailed above, if it deemed necessary to undertake a combustion analysis as detailed in chapter 11.3 section 11. S Figure 5.4 Caution: After any periodical servicing or disturbance the combustion chamber silicon seal S Figure 5.4 must be fully inspected and replaced at the discretion of the service engineer. After any disturbance to the chamber door seal the appliance must undergo a full analytical combustion performance check. - 12 -