Heronhill - for all your Toshiba requirements No. Photo / Explanatory diagram Procedure Assembly 3 Return a set of the refrigeration cycle assembly into the outdoor unit base plate and reassemble sound insulation board, partition plate assembly, fan motor assembly, and side cabinet (R/L) as original. Fix the thermostat fixing plate to the side cabinet (R), built in the inverter assembly, and then connect various cables. After then, incorporate front cabinet, upper cabinet, wiring cover, and valve cover as before. Return a set of the refrigeration cycle assembly into the outdoor unit base plate, and assemble sound insulation board, partition plate assembly, fan motor assembly, and side cabinet (R/L) as original. 3-1 Thermostat fixing plate Using screws (Self-tapping screw type-B Ø4 × 8mm, stainless), fix the thermostat fixing plate to the side cabinet (R). Side cabinet (R) 3-2 Do not make cord heater loose. Do not put the heating part near the electric parts box. For the cord heater, perform cable process so that there is no looseness or sag at the fan side. Perform cable process for collected cord heater and fan motor lead cables. 3-3 Perform cable process for the cord heater together with the fan motor lead cable, and collect the remained part of cables at cable process part of the inverter. Secure the power cord for the cord heater to the terminal block mounting plate using the P-shape clamp, and pull it out from the wiring area of the side cabinet (R). P-shape clamp * Check that there is the marked part of the cord heater on the outdoor unit base plate or near it. When there is the heating part near the electric parts box, a fire may generate. Power cord for cord heater To keep the lead wires from coming into contact with the edges of the sheet metal or tips of the screws, wrap the shield tubes around the leads to protect them and use the bundling ties to secure them. 3-4 4 After incorporating the inverter assembly as before, furthermore perform cable process for cord heater and power cord. Since the lead wires connected to the cord heater and thermostat may come into contact with the edges of the sheet metal or tips of the screws, wrap the shield tubes around the leads to protect them and use the bundling ties to secure them. Incorporate front cabinet, upper cabinet, wiring cover, water-proof cover and valve cover as before. In installation work, connect power cord for the cord heater to another breaker separated from one for power cord of the air conditioner. – 191 – Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807