Download Operating instructions Explosion-proof gear units R..7, F..7, K..7, S..7
Transcript
Inspection and Maintenance Inspection/maintenance work on adapter AR Inspecting / changing the friction ring pads, adjusting the slip torque 6 It is only possible to check and adjust the slip torque accurately by using a torque wrench with an appropriate connection piece. For the setting of values, see the table on page 71. [1] [2] [3] [4] [5] [6] [7] [8] 52871AXX Figure 20: Inspecting / changing the friction ring pads [1] Locking screw [5] Friction ring pad [2] Cylinder head screw [6] Cup spring [3] Proximity switch [7] Slotted round nut [4] Friction disk [8] Friction hub AR71-115 [1] Z AR132-195 [2] [4] Z [5] [3] 52872AXX Figure 21: Rough torque setting [1] Marking [4] Markings (carrier disk) [2] Multi-tang washer (tangs) [5] Slotted round nut [3] Slotted round nut Operating Instructions – Explosion-Proof Gear Units R..7, F..7, K..7, S..7, Spiroplan® W Series 69