Installation/Assembly Coupling of AM adapter AM../RS adapter AM with backstop 5 Check the direction of rotation of the drive prior to assembly or startup. Please inform the SEW-EURODRIVE service in the case of incorrect direction of rotation. The backstop is maintenance-free in operation, and does not require any further maintenance work. Backstops have a minimum lift-off speed depending on the size (see following table). . CAUTION! If the actual speed level is below the minimum lift-off speed level, the backstops are subject to wear, and the resulting friction causes the temperature to increase. Potential damage to property! • • In rated operation, the lift-off speeds must not drop below the minimum values. During startup or braking, the lift-off speeds may drop below the minimum levels. Maximum locking torque of backstop [Nm] Minimum lift-off speed [rpm] AM80/90/RS, AM143/145/RS 45 800 AM100/112/RS, AM182/184/RS 200 670 AM132/RS, AM213/215/RS 470 660 AM160/180/RS, AM254/286/RS 630 550 AM200/225/RS, AM324-365/RS 1430 600 Type Operating Instructions – P002 – P082 Series Planetary Gear Units 51