Packet and 1
STATUS Packet. To set the different signals to the right value, it is necessary to send a
STATUS
packet to the product.
Here are some examples of STATUS packets :
0xDD 0x01 0x08 0x40 0x26 ↔bit RTS is on
to start a data call, all the bits should be on :
0xDD 0x01 0x08 0xC0 0xA6 (bits DTR and RTS are on
Error manage
When received data checksum is error ,we should discard the firs three byte, Start pattern,
Data length and Data packet type, then find “0xAA” or “0xDD” to start the next data frame.
If you do this action, you will skip the error data frame and get next correct frame start byte
that maybe “0xAA” or “0xDD”.
The high layer protocol will guarantee the error data to be resend.
Restriction
The autobauding mode is not available when the Multiplexing Mode is activated :the
serial link speed must be set to a fixed rate.