Download VT595 User Manual

Transcript
VT595 User Manual
VT-ENG-595-V1 20120313
1. Parts and Functions
49mm
27.6 mm
Speaker
137.5mm
Camera Lens
Night View LED
27.6mm
Call Button
Microphone
2. Terminal Descriptions
N.O
COM
4B
3Y
2W
1R
••
••
••
••
••
1R (Red): Power positive. +12V present when Door Station calling or being monitored.
2W (White): Power negative (Ground).
3Y (Yellow): Image signal (Video signal).
4B (Black): Talk and control signal (Audio signal).
COM(Blue),N.o(Green):Normally opened connection port.
-1-
3. Mounting
3.1 Mounting Without Rainy Cover
1
2
3
PA3*25
TX20-4*10
3.2 With Rainy Cover and 30 degree angle
1
2
3
PA4*25
PM3*12
TX20-4*10
Note:Both rainy cover and 30 degree angle accessories are supplied seperately.
-2-
4
4. System Wiring and Connections
4.1 Basic Connection
Red
White
Yellow
Black
1R
2W
3Y
4B
Black
Red
White
Yellow
TO Monitor
JS_OS1
Shielding Layer of the RVVP Cable
4.2 Electric Lock Connection
•• Mode1:Door Lock Controlled With External Power
Indoor Monitor
Connection Port
Note:
1.Electronic lock of power-on-to-unlock
shoule be used.
2.The inside relay contact is restricted to
DC 24V/1A.
+
Black
Green
Blue
Red
White
Yellow
1R 2W 3Y 4B
+ -
-
-3-
•• Mode2:Door Lock Controlled With Internal Power
Indoor Monitor
Connection Port
Note:
1.Electronic lock of power-on-to-unlock
shoule be used.
2.The door lock is limited to 12V,and
holding current must be less than 250mA
Green
Blue
Yellow
Black
White
Red
1R 2W 3Y 4B
+
5. Precautions
••
Do not install camera/bell where there would be a bright light behind the visitor (or where there
would be a bright background), or in a place where the camera lens would be directly exposed to
sunlight or a bright light. If light shines directly into the outdoor camera lens, the image will be overexposed; it will look white or silhouetted. Take precautions against this.
••
Do not install the unit in places where High or extreme cold temperature, moisture or humidity
extremes, Constant vibration or impact, steam or smoke.
6. Specifications
Power Supply:
Consumption: Video Output:
Camera Lens: Working Temperature:
Dimension:
DC 10~12V (powered by monitor)
150mA in working state (latch not included)
75Ohm, 1Vp-p
1/4 ACS 4T image sensor with DSP processor
-10ºC ~ 40ºC
137(H)x49(W)x28(D)mm
-4-