Download More than pumps Installation and Operating Instructions (Seite 6
Transcript
ModulA … GREEN 32F-12 220, 40-8 220, 40-10 220, 40-12 250, 40-18 250, 50-6 240, 50-6 270, 50-8 240, 50-12 270, 50-18 270, 65-8 270, 65-8 340, 65-12 340, 65-15 340, 80-8 360, 80-12 360, 100-12 450 Installation and Operating Instructions (Seite 6) Instrucciones de instalacion y funcionamiento (Seite 37) Instrucţiuni de montaj şi exploatare (Seite 68) More than pumps 3 EN Declaration of Conformity We Biral AG declare under our sole responsibility that the products ModulA … GREEN to which this declaration relates, are in conformity with the Council Directives on the approximation of the laws of the EC Member States relating to: – Machinery (2006/42/EC) Standard: 12100-1: 2010 – Electrical equipment designed for use within certain voltage limits (2006/95/EC) Standards: EN 60335-1:2002, EN 60335-2-51:2003 – Electromagnetic compatibility (2004/108/EC) Standards: EN 61000-6-2:2005, EN 61000-6-3:2007 – Only for types marked with the EEI. (See the pump nameplate): Ecodesign (2009/125/EC) Circulator Pumps Commission Regulation No 641/2009 Standards: EN 16297-1:2012, EN16297-2:2012 ES Declaración de conformidad Nosotros Biral AG declaramos bajo nuestra única responsabilidad que los productos ModulA … GREEN son conformes con las Directivas del Consejo relativas a la aproximación de las legislaciones de los Estados Miembros de la CE sobre – Máquinas (2006/42/CE) Norma: EN 12100-1: 20101 – Material eléctrico destinado a utilizarse con determinadas límites de tensión (2006/95/CE) Normas: EN 60335-1:2002, EN 60335-2-51:2003 – C ompatibilidad electromagnética (2004/108/CE) Normas: EN 61000-6-2:2005, EN 61000-6-3:2007 – Unicamente a las circuladoras marcadas con el EEI. (Véase la placa de caracteristicas.): Diseno ecológico (2009/125/EC) Bombas circuladoras: Reglamento de la Comisión no 641/2009 Normas: EN 16297-1, EN16297-2 RO Declaraţie de conformitate Wir Biral AG erklären in alleiniger Verantwortung, dass die Produkte ModulA … GREEN auf die sich diese Erklärung bezieht, mit folgenden Richtlinien des Rates zur Angleichung der Rechtsvorschriften der EG Mitgliedstaaten übereinstimmen: – Maschinen (2006 / 42 / EG) Norm: EN 12100-1: 2011 – Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen (2006 / 95 / EG) Normen: EN 60335-1:2002, EN 60335-2-51:2003 – Elektromagnetische Verträglichkeit (2004 / 108 / EG Normen: EN 61000-6-2, EN 61000-6-3 – Ökodesign (2009 / 125 / EG) Umwälzpumpen: Verordnung der EU-Kommission Nr. 641 / 2009. Normen: EN 16297-1:2012, EN 16297-2:2012 (gilt nur für Typen, gekennzeichnet mit dem EEI. EEI steht für Energieeffizienzindex, siehe Firmenschild) Münsingen, 1st February 2015 Andrew Wenger Technical Director Person authorised to compile technical file and empowered to sign the EC declaration of conformity. Biral AG Südstrasse 10, CH-3110 Münsingen Phone +41 (0) 31 720 90 00, Fax +41 (0) 31 720 94 42 [email protected], www.biral.ch 4 Rauhwerte Ra 12.5 6.3 3.2 1.6 0.8 0.4 Rauheitsklassen N10 Allgemeintoleranzen ISO 2768-mK N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 Series Series Seria T1 T3 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 264.5 B1 T2 k2 230.5 k1 238 L1 Dimensions Dimension Dimensiuni ModulA…GREEN d1 DN max 2m B2 32F-12 220 40-8 220 40-10 220 40-12 250 40-18 250 50-6 240 PN 6-16 PN 6-16 PN 6-16 PN 6-16 PN 6-16 PN 6-16 DN 32 40 40 40 40 50 L1 220 220 220 250 250 240 B1 144.6 147.5 147.5 153.8 153.8 160.4 961582_00 B3 50-6 270 PN 6-16 50-8 240 50-12 270 PN 6-16 PN 6-16 50 Stück II I 50 1 270 Pos Gegenstand Änd.Index D Datum Visum ModulA GREEN 166.9 für BA 270 Material 160.4 Massbild 50 240 Modell/Art.Nr Bemerkung Ersetzt durch: Ersatz für: Massstab gezeichnet 15.02.2013 ts 1:4.4 166.9 geprüft 15.02.2013 ts Freigabe 15.02.2013 ts PDM_Nr TD-0021609 Zeichnungsnummer Änd.Index B2 72.3 72.3 72.3 72.3 72.3 72.1 74.4 Biral AG CH-3110 Münsingen B3 100 100 100 100 100 100 100 100 100 D 140 150 150 150 150 165 165 165 165 k1 (PN 6) 90 100 100 100 100 110 110 110 110 k2 (PN 10/16) 100 110 110 110 110 125 125 125 125 d1 4×14/19 4×14/19 4×14/19 4×14/19 4×14/19 4×14/19 4×14/19 4×14/19 4×14/19 T1 287.5 290.4 290.4 290.4 290.4 295.5 297 295.5 297 T2 56 59 59 62 62 64 64 64 64 T3 222.5 225.4 225.4 225.4 225.4 225 225 225 225 kg 17.3 18.3 18.3 18.1 18.1 19.6 20.1 19.6 20.1 50-18 270 65-8 270 65-8 340 65-12 340 65-15 340 PN 6-16 PN 6-16 PN 6-16 PN 6-16 PN 6-16 DN 50 65 65 65 65 L1 270 270 340 340 340 B1 166.9 184 184 184 184 B2 74.4 82 82 82 82 B3 100 100 100 100 100 D 165 185 185 185 185 k1 (PN 6) 110 130 130 130 130 k2 (PN 10/16) 125 145 145 145 145 d1 4×14/19 4×14/19 4×14/19 4×14/19 4×14/19 T1 297 391.5 306.9 306.9 306.9 T2 64 62.1 68.7 68.7 68.7 T3 225 239 233 233 233 kg 20.8 22.6 23.5 23.5 26.0 72.1 961582 74.4 00 5 Rauhwerte Ra 12.5 6.3 3.2 1.6 0.8 0.4 Rauheitsklassen N10 Allgemeintoleranzen ISO 2768-mK N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 Series Series Seria T1 T3 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 264.5 B1 T2 k2 230.5 k1 238 L1 Dimensions Dimension Dimensiuni ModulA…GREEN d1 DN max 2m 961582_00 B3 B2 D 80-8 360 80-8 360 80-12 360 80-12 360 100-12 450 100-12 450 PN 6 PN 10-16 PN 6 PN 16 PN 6 PN 16 DN 80 80 80 80 100 100 L1 360 360 360 360 450 450 B1 219.6 219.6 219.6 219.6 223.2 223.2 B2 97 97 97 97 98.4 98.4 B3 100 100 100 100 100 100 D 200 200 200 200 220 220 k1 (PN 6) 150 – 150 – 170 – – 160 – 160 – 180 k2 (PN 10/16) d1 4×19 8×19 4×19 8×19 4×19 8×19 T1 333.9 333.9 411.9 333.9 354.1 354.1 T2 82.7 82.7 82.7 82.7 80.6 80.6 T3 240 240 240 240 252 252 kg 31.1 31.1 31.1 31.1 36 36 1 Stück II I Pos Gegenstand Änd.Index Datum Visum Material Modell/Art.Nr Bemerkung Ersetzt durch: ModulA GREEN Ersatz für: Massstab gezeichnet 15.02.2013 ts 1:4.4 Massbild für BA Biral AG CH-3110 Münsingen geprüft 15.02.2013 ts Freigabe 15.02.2013 ts PDM_Nr TD-0021609 Zeichnungsnummer 961582 Änd.Index 00 6 | english Contents 1. Safety information..................................................................................................................8 1.1 General remarks..............................................................................................................8 1.2 Identification of notices....................................................................................................8 1.3 Staff qualification and training..........................................................................................8 1.4 Risks in the event of non-compliance with the safety information...................................8 1.5 Safety-conscious work.....................................................................................................8 1.6 Safety information for the operator / operating personnel................................................9 1.7 Safety information for installation, maintenance and inspection works...........................9 1.8 Unauthorised reconstruction and production of spares...................................................9 1.9 Improper operating methods............................................................................................9 2. Symbols used.......................................................................................................................10 3. General information.............................................................................................................11 3.1 Purpose.........................................................................................................................11 3.2 Requirements of the delivery medium...........................................................................11 3.3 Operating conditions......................................................................................................12 3.4 Non-return valve............................................................................................................13 3.5 Protection from the effects of frost.................................................................................13 3.6 Insulation.......................................................................................................................13 3.7 Flow direction.................................................................................................................13 4.Installation.............................................................................................................................14 4.1 General notes................................................................................................................14 4.2 Flushing heating equipment (for extended pump).........................................................14 4.3 Installation......................................................................................................................14 4.4 Permissible installation positions...................................................................................15 4.5 Install the pump in the unit.............................................................................................16 4.5.1 Flange connection...............................................................................................16 4.6 Installing the frequency converter..................................................................................17 4.7 Fitting the connector......................................................................................................18 5. Electrical connection...........................................................................................................19 5.1 Supply voltage...............................................................................................................19 5.2 Connection of the power supply....................................................................................20 5.3 Connection drawing Clamp description.........................................................................21 5.4 Switch settings...............................................................................................................22 5.4.1 Switch 1, Fault or operating signal (switchable)..................................................22 5.4.2 Switch 2, external OFF or external ON (switchable)............................................23 5.4.3 Switch 3, power limit (can be activated)..............................................................23 english | 7 6.Start-up..................................................................................................................................24 6.1 General..........................................................................................................................24 6.2 Operational control........................................................................................................44 7.Settings.................................................................................................................................25 7.1 Control panel.................................................................................................................25 7.2 Types of control.............................................................................................................25 7.3 Delivery height (A2).......................................................................................................26 • 7.4 Display of the current delivery height (LED V )...............................................................26 7.5 Summary of maximum delivery height and delivery amount.........................................26 7.6 Activating / deactivating the control keys........................................................................27 7.7 START / STOP pump......................................................................................................27 7.8 Activate / deactivate dry running detection.....................................................................27 7.9 Biral impeller..................................................................................................................28 7.10 On-site adjustment of the pump.....................................................................................28 8. Fault summary and checklist..............................................................................................29 9.Sensor...................................................................................................................................31 10. Accessories / versions..........................................................................................................32 10.1 Biral Remote..................................................................................................................32 10.2Biral interface module, BIM A2 signal module (for self-regulating pumps)....................33 10.3Biral interface module, BIM B2 control module (for controlled pumps)..........................33 10.4 Heating and domestic hot water version........................................................................33 11.Technical data.......................................................................................................................34 12.Disposal.................................................................................................................................34 13.Spare parts list......................................................................................................................35 8 | english 1. Safety information Warning This product may only be installed and used by people who have adequate knowledge and experience. People with limitations in their physical or mental capacity or sensory perception, may not use the product, unless they have been sufficiently trained by a person who is responsible for their safety. The product must be kept out of the reach of children. The product must not be used by children, e.g. as a toy. 1.1 General remarks These installation and operating instructions contain items of information of fundamental importance which must be taken into account during assembly, operation and maintenance. They should therefore be read without fail before installation and commissioning by the fitter and also the responsible specialist staff / operator. They must always be available for consultation at the plant’s place of deployment. Not only are the general safety hints included in this «Safety Hints» section to be observed, but also the special items of safety information included in the other sections. 1.2 Identification of notices Information signs mounted directly on the plant, such as, for example –– rotating direction arrow –– symbols for fluid connections must be obeyed without fail and be kept in a fully legible state. 1.3 Staff qualification and training The staff deployed for assembly, operating, maintenance and inspection tasks must show that they have the appropriate qualifications for such work. The field of responsibility, competence and supervision of the staff must be stipulated exactly by the operator. 1.4 Risks in the event of non-compliance with the safety information Non-compliance with the safety information can result in both danger for persons and also for the plant and the environment. Non-compliance with the safety information can lead to the loss of claims for damages of any kind. In detail, non-compliance, for example, may result in the following risks: –– failure of important functions in the plant –– failure of prescribed methods for servicing and maintenance –– danger to persons through electrical and mechanical causes english | 9 1.5 Safety-conscious work The safety information contained in these installation and operating instructions, the existing national regulations for the prevention of accidents, as well as any internal working, operating and safety regulations stipulated by the operator must be observed. 1.6 Safety information for the operator / operating personnel Any risks from electric power must be eliminated (For details see, for example, the regulations published by NIN (CENELEC) and the I.E.E.). 1.7 Safety information for installation, maintenance and inspection works The operator has to ensure that all installation, maintenance and inspection works are carried out by authorised and qualified specialist personnel who have informed themselves adequately about the requirements by a thorough study of the installation and operating instructions. Basically, any works on the plant should only be carried out when it is at a standstill and not carrying any electrical current. Directly after completion of the works, all safety and protective installations must be mounted or activated again. Before re-commissioning, the points listed in the section «Electrical connection» must be observed. 1.8 Unauthorised reconstruction and production of spares Reconstruction of or changes to pumps are only permissible after consultation with the manufacturer. Genuine spare parts and accessories authorised by the manufacturer serve the cause of safety. The use of other parts can cancel any liability for the resultant consequences of this. 1.9 Improper operating methods The operating reliability of the pumps supplied is only guaranteed with appropriate application of the section «Intended application» of the Installation and Operating Instructions. The limit values given in the technical data must not be exceeded on any account. 10 | english 2. Symbols used Warning Serious personal injury may result from not adhering to these safety notes. Warning Danger from dangerous electrical voltage. If these safety instructions are not adhered to, there is a risk of electric shock, which may lead to serious injury or death. Warning Risk of injury or burns from hot surfaces! Warning Risk of injury from falling objects! Warning Risk of injury from escaping steam! Not adhering to these safety notes may cause malfunctioning or material damage. This contains advice or notes that facilitate work and ensure safe operation. english | 11 3. General information The Biral series, ModulA consists of a complete range of circulation pumps with integrated frequency converter, which enable independent or controlled adaptation of output to the actual requirement of each system. Therefore, in many systems, energy consumption will be reduced and the control behaviour of the system improved. Besides this, current noise from control cabinets can be reduced effectively. All necessary settings can be adjusted using the control panel for the pump. 3.1 Purpose Biral circulation pumps of the ModulA series are intended for the circulation of liquids in the following systems: –– ModulA GREEN in air-conditioning units and cooling systems The pumps can also be used in the following systems: –– Geothermal heat pumps –– Thermal solar equipment The pumps are suitable for use in systems with variable and constant delivery volumes. 3.2 Requirements of the delivery medium The pump is suitable for delivery of pure, thin, non-explosive and non-aggressive media without fixed or long-fibred elements, which do not affect the pump either mechanically or chemically. –– Heating water: Requirements according to current standards that apply to water quality in heating systems: (e.g. VDI 2035) –– Glykol: The pump can be used for delivering water-glycol mixes. Maximum permissible viscosity: 50 mm²/s (cSt). This corresponds to a water-ethylene-glycol mix with a glycol content of around 50% at –10°C. The pump is controlled via an output-limiting function that protects against overload. The delivery of glycol mixes affects the MAX characteristic curve because the delivery capacity is reduced accordingly, based on the glycol content and temperature of the media. So that the effect of the glycol is not reduced, temperatures above the nominal temperature given for the medium should be avoided. Generally, the operating duration with high media temperatures should be minimised. Before adding the glycol mix, it is vital that the system is cleaned and rinsed. To avoid corrosion or precipitations, the glycol mix should be checked regularly and changed if necessary. If the glycol mix has to be further thinned, the specifications from the glycol manufacturer should be adhered to. For the delivery of a liquid with density that differs from water and/or kinematic viscosity, the delivery output is reduced. 12 | english Warning The pump may not be used to deliver combustible media such as diesel and fuel. Warning The pump may not be used to deliver aggressive liquids such as acids or seawater. 3.3 Operating conditions –– Medium temperature: ModulA GREEN –10 °C to +110 °C –– Operating pressure: The maximum permissible operating pressure is indicated on the nameplate. (6 bar, 10 bar or 16 bar) Minimum operating pressure at the pump intake ports (intake pressure) at 500 m above sea level: Media temperature 75°C ModulA … 95°C 110°C Supply pressure [bar] ModulA 32F-12 220 0.92 1.32 1.92 ModulA 40-8 220 0.12 0.52 1.12 ModulA 40-10 220 0.12 0.52 1.12 ModulA 40-12 250 0.12 0.42 1.02 ModulA 40-18 250 0.12 0.42 1.02 ModulA 50-6 240 0.12 0.12 0.72 ModulA 50-6 270 0.12 0.12 0.72 ModulA 50-8 240 0.12 0.12 0.72 ModulA 50-12 270 0.12 0.42 1.02 ModulA 50-18 270 0.22 0.62 1.22 ModulA 65-8 270 0.22 0.62 1.22 ModulA 65-8 340 0.22 0.62 1.22 ModulA 65-12 340 0.12 0.52 1.12 ModulA 65-15 340 0.42 0.82 1.22 ModulA 80-8 360 0.52 0.92 1.52 ModulA 80-12 360 0.52 0.92 1.52 ModulA 100-12 450 0.52 0.92 1.52 Per ± 100 m height ± 0.01 bar –– Ambient temperature: 0°C to 40°C english | 13 3.4 Non-return valve If a non-return valve is fitted, the pump must be adjusted (see 7.2), so that the discharge pressure of the pump exceeds the closing pressure of the valve at all times. This must be adhered to in particular for the proportional pressure control (reduced delivery height for decreasing delivery flow). 961864_00 3.5 Protection from the effects of frost Where there is a risk of frost during downtime periods, measures required to avoid frost damage must be taken. 3.6 Insulation The pump can be insulated together with the pipe system. A eep the drainage K outlet at the motor free. A Never cover the frequency converter or the control panel with insulation. 3.7 Flow direction The arrow on the pump casing indicates the flow direction. 961584_00 14 | english 4. Installation 4.1 General notes ModulA is only intended for installation indoors. The pumps must be mounted voltage-free so that no energy can be transferred from the pipes to the pump casing. The pumps can be installed directly in the pipe, provided the pipes are designed for the weight of the pump. Installation is only possible after completion of all welding and soldering work on the system. Avoid drops of water on the pump motor, especially the frequency converter. Warning The local regulations for the lifting and carrying of loads must be adhered to. The weight of the pump is given on the packaging. 4.2 Flushing heating equipment (for extended pump) To avoid unwanted interruptions to operations and non-running of the pump after longer periods of inactivity, we recommend thoroughly flushing out the equipment following the new installation or adaptation of heating and refilling. The equipment must correspond with the latest technology. (Placement of expansion vessel or safety flow). 4.3 Installation Install only after completion of all welding or soldering work on the equipment. Water drops should be avoided on the pump motor, especially on the electronics. The pump casing should be installed voltage-free in the equipment. Rauhwerte Ra 12.5 6.3 3.2 1.6 0.8 0.4 Rauheitsklassen N10 Allgemeintoleranzen ISO 2768-mK N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 961869_00 1 Stück II I Pos Gegenstand Änd.Index Datum Visum Material Modell/Art.Nr Bemerkung Ersetzt durch: Ersatz für: Massstab gezeichnet 16.12.2014 nma ModulA BG2 Motor waagrecht für BA 1:2 geprüft Freigabe PDM_Nr Biral AG CH-3110 Münsingen TD-0028861 Zeichnungsnummer 961869 Änd.Index 00 Rauhwerte Ra 12.5 6.3 3.2 1.6 0.8 0.4 Rauheitsklassen N10 Allgemeintoleranzen ISO 2768-mK N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 english | 15 4.4 Permissible installation positions The rotor shaft must always be horizontal and never vertical. 961583_00 Delivered as standard with the connector on the left. 1 Stück II I Pos Gegenstand Änd.Index Datum Visum Material Ersatz für: 961585_00 ModulA GREEN Modell/Art.Nr Bemerkung Ersetzt durch: Massstab gezeichnet 15.02.2013 ts 1:4 Motor waagrecht für BA geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021617 Zeichnungsnummer Biral AG CH-3110 Münsingen Änd.Index 00 961583 961586_00 II I Änd.Index Datum Visum Ersetzt durch: 1:4.4 Montageposition Biral AG CH-3110 Münsingen II I Änd.Index Datum Ersatz für: Massstab gezeichnet 15.02.2013 ts ModulA GREEN Visum geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021620 Zeichnungsnummer Änd.Index 00 961585 Ersetzt durch: Ersatz für: Massstab gezeichnet 15.02.2013 ts ModulA GREEN Montageposition Stecker 3-6-9-12 Biral AG CH-3110 Münsingen 1:4.4 geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021621 Zeichnungsnummer 961586 Änd.Index 00 The connector must not be facing downwards, as otherwise water can easily penetrate. Before installing the pump, the motor can be rotated by 90° either way. To do this, loosen the 4 screws on the casing and turn the motor head to the permissible motor position. Do not move or damage the seal between the motor and pump casing. After placing the screws, tighten them crosswise. 16 | english 4.5 Install the pump in the unit ➀ Close the shut-off valves and ensure that the system is without pressure when fitting the pump. ➁ Install the pump in the pipe with seals. 1 2 Warning Risk of injury from escaping steam! 1 961589_00 4.5.1 Flange connection The pump flanges are drilled with mounting holes, PN6/PN10/ PN16. For safe screwing of the flanges, the shims supplied (B) must be fitted. II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 15.02.2013 ts ModulA GREEN Pumpe mit Absperrschieber Bild1 1:5 DN für BA geprüft Freigabe 18.02.2013 ts 18.02.2013 ts AZeichnungsnummer PDM_Nr Biral AG CH-3110 Münsingen TD-0021624 Änd.Index 00 961589 B Safety elements (e.g. snap rings) are not permissible. For PN 10/16, special seals and screws must be used. 961590_00 Warning Use the relevant screws for nominal pressure PN. Änd.Index II I A B M 960573_00 960573_00 Datum Visum DN 50 M für BA Biral AG CH-3110 Münsingen Ø Ø PN 6 PN 10 / 16 PN 6 PN 10 / 16 M 12 M 16 Ø 14 Ø 18 M 16 M 16 – – DN 65 DN 80 DN 100 Recommended screw tightening torque –– for M 12 <40 Nm –– for M 16 <95 Nm Datum Visum Änd.Index Ersetzt durch: Ersatz für: II Iof combined flange with combined flange is not Installation Massstab gezeichnet 10.12.2014 nma permissible. Flansch PN6/10/16 1:2 geprüft 10.12.2014 nma Änd.Index Datum Visum II für BA Freigabe Ersetzt durch: I PDM_Nr Biral AG Ersatz für: Massstab gezeichnet 15.02.2013 ts Pumpe mit Absperrschieber Bild2 1:5 DN 32 DN 40 Ersetzt durch: ModulA GREEN 10.12.2014 nma Ersatz für: TD-0028815 Zeichnungsnummer CH-3110 Münsingen Flansch PN6/10/16 960573 für BA Biral AG CH-3110 Münsingen Änd.Indexgezeichnet 10.12.2014 nma Massstab 00 1:2 geprüft 10.12.2014 nma Freigabe 10.12.2014 nma PDM_Nr TD-0028815 Zeichnungsnummer 960573 Änd.Index 00 geprüft 18.02.2013 ts Freigabe 18.02.2013 ts PDM_Nr TD-0021625 Zeichnungsnummer 961590 Änd.Index 00 english | 17 4.6 Installing the frequency converter 100 238 230.5 961563_00 max 2m Only the original connection cable (2 m) should be used between the frequency converter and motor. II I Änd.Index ModulA Datum Massbild Visum 40 Ersetzt durch: Fix the wall mount. Ersatz für: Massstab gezeichnet 25.01.2013 ts 8 Bausatz für abgesetzte Montage B 8x38 geprüft 15.02.2013 ts Freigabe 15.02.2013 ts PDM_Nr TD-0021441 C 5x40 Zeichnungsnummer 961563 Änd.Index 00 91 Biral AG CH-3110 Münsingen 1:4.4 961591_00 Warning The mount must always be fitted vertically. Mount the frequency converter. II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 18.02.2013 ts ModulA GREEN 1:2.5 Bausatzt kpl Wandmontage geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021630 Zeichnungsnummer Biral AG CH-3110 Münsingen 961593_00 II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 18.02.2013 ts ModulA GREEN 1:2.5 Bausatzt kpl Wandmontage Biral AG CH-3110 Münsingen geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021632 Zeichnungsnummer 961593 Änd.Index 00 961591 Änd.Index 00 18 | english 4.7 Fitting the connector – Carefully plug in the connector on the motor side ➀ – Screw in the M6×40 ➁ screws ➀ ➁ 961594_00 –P ush in the sensor cable ➂ – Fit the cable screws ➃ ➂ II I Änd.Index Datum Visum ➃ Ersetzt durch: Ersatz für: Massstab gezeichnet 18.02.2013 ts ModulA GREEN Stecker für Motor 961595_00 – Fix the cover ➄ with 3 screws Biral AG CH-3110 Münsingen 1:3.5 geprüft 02.04.2013 ts Freigabe 02.04.2013 ts PDM_Nr TD-0021638 Zeichnungsnummer 961594 ➄ Änd.Index 00 english | 19 5. Electrical connection Electrical connection should be carried out in accordance with the local regulations. It is vital to ensure that the voltage and frequency indicated on the nameplate are compatible with the mains supply available. Warning Before carrying out any electrical connection work, the voltage supply must be switched off. The pump must be connected to an external network switch with a contact opening on all poles of minimum 3 mm. The protection against indirect contact can be achieved by earthing or potential equalisation. If the pump is connected to an electrical installation, which has an FI circuit breaker for additional protection, the FI circuit breaker must trigger with a pulsing direct current component if earthing fault currents arise. The FI circuit breaker must be marked with the following symbol: Externer Schalter FI L N L N Sicherung (min.10A, träge) The pump does not require any external motor protection. The motor has integrated overtemperature protection, which offers safeguarding against overloading that appears slowly and against blocking according to IEC 34-11: TP 211. 5.1 Supply voltage 1×230V ±10%, 50 / 60 Hz, PE The voltage tolerances are set for equalising voltage fluctuations 961807_00 on the mains. They are not for operating pumps with voltages other than those shown on the nameplate. With direct mains connection, the pump may not be switched on and off at the mains more than four times an hour. If the pump is switched on directly via the mains, it only starts after a 5-second delay. 20 | english 5.2 Connection of the power supply The pump must be protected on-site (min. 10 A, slow) and must be connected to an external mains switch. All cables used must have a heat resistance of up to 85 °C. They must not be in contact with the pipe or the pump and motor casing. All cables must be connected in accordance with EN 60204-1 and EN 50174-2: 2000. The electrical connection must be made as indicated on the nameplate. ModulA… Nominal current [A] Output P1 [W] ModulA 32F-12 220, ModulA-D 32F-12 220 0.17 – 1.50 16 – 328 ModulA 40-8 220, ModulA-D 40-8 220 0.20 – 1.21 20 – 268 ModulA 40-10 220, ModulA-D 40-10 220 0.19 – 1.54 18 – 341 ModulA 40-12 250, ModulA-D 40-12 250 0.18 – 1.91 17 – 421 ModulA 40-18 250, ModulA-D 40-18 250 0.18 – 2.63 16 – 594 ModulA 50-6 240, ModulA-D 50-6 240 0.21 – 1.09 21 – 236 ModulA 50-6 270 0.21 – 1.09 21 – 236 ModulA 50-8 240, ModulA-D 50-8 240 0.21 – 1.42 22 – 315 ModulA 50-12 270, ModulA-D 50-12 270 0.21 – 2.32 20 – 516 ModulA 50-18 270, ModulA-D 50-18 270 0.21 – 3.34 22 – 742 ModulA 65-8 270 0.24 – 2.10 22 – 464 ModulA 65-8 340, ModulA-D 65-8 340 0.24 – 2.10 22 – 464 21 – 736 ModulA 65-12 340, ModulA-D 65-12 340 0.22 – 3.32 ModulA 65-15 340, ModulA-D 65-15 340 0.28 – 5.68 30 – 1254 ModulA 80-8 360, ModulA-D 80-8 360 0.29 – 3.08 29 – 704 ModulA 80-12 360, ModulA-D 80-12 360 0.32 – 5.56 32 – 1282 ModulA 100-12 450, ModulA-D 100-12 450 0.32 – 6.78 35 – 1563 external 2 switch FI N N L L Protection (minimum 1 10A, inert) 961613_02 Example of a typical mains connection, 1x230V ±10%, 50 / 60Hz Legende: 1 Sicherung (min.10A, träge) 2 Externer Schalter english | 21 5.3 Connection drawing Clamp description Mains connection: 1x230V +/- 10%, 50/60Hz Terminals: L, N, PE Mains connection +24- 24 V DC out 11, 10External OFF and external ON 52, 54, 51Fault notification or operation notification Switch: 1 fault notification or operation notification (switchable) 2 External OFF or external ON (switchable) 3 Power limit (can be activated) Switch DC out 24V max. 20mA 11 10 52 54 51 max. 250V AC 2A min. 5V DC 20mA II I Änd.Index Datum Visum L N AC in ~1x230V ±10% 50/60 Hz Ersetzt durch: 961566_00 +2 4- Ersatz für: Massstab gezeichnet 08.02.2013 ts ModulA 750W Anschlussschema mit FU für BA Biral AG CH-3110 Münsingen 1:2 geprüft 15.02.2013 ts Freigabe 15.02.2013 ts PDM_Nr TD-0021543 Zeichnungsnummer 961566 Änd.Index 00 22 | english 5.4 Switch settings operating signal 1 Switch 1 II I ON II I ModulA Änd.Index II I ON 1 II I Änd.Index Änd.Index Datum Datum 52 ON 52525454 5151 Visum Visum Visum Ersetzt durch: ON2 ModulA active 51,52,54 Freigabe PDM_Nr Änd.Index 00 961827 00 54 51 Ersatz für:operating 00 TD-0028419 inactive ts Massstab gezeichnet 13.11.2014 geprüft 1:1 geprüft Freigabe PDM_Nr 5252 5454 5151 52 54 51 Änd.Index 00 52 54 51 1 2 3 961865_01 Änd.Index ON 01 II ModulA Datum I Änd.Index 16.01.2015 Visum ON ts Datum Änd.Index Ersetzt Visum durch: II I Ersetzt durch: Datum Visum Ersatz für: Ersetzt durch: Ersatz für: Freigabe Freigabe 51,52,54 PDM_NrTD-0028816 TD-0028419 PDM_Nr Biral AG Zeichnungsnummer Zeichnungsnummer Biral AG Biral AG 961827Münsingen CH-3110 Münsingen CH-3110 961865 CH-3110 Münsingen Änd.Index Datum Visum 01 16.01.2015 ts Ersetzt durch: Ersatz für: Massstab gezeichnet 10.12.2014 nma ModulA 3:1 Switch 3 geprüft Freigabe PDM_Nr Biral AG CH-3110 Münsingen 1:1 3:11:1geprüftgeprüft Relaisaugänge Switch 3Relaisaugänge 3 51,52,54 3 II I Ersatz für: Massstab gezeichnet 13.11.2014 ts Massstab gezeichnet 10.12.2014 Massstab gezeichnet 13.11.2014 nma ts ModulA ModulA TD-0028816 Zeichnungsnummer 961865 Änd.Index 01 geprüft Freigabe PDM_Nr TD-0028419 Zeichnungsnummer Änd.Index Änd.Index 961827 00 01 961827_00 961827_00 961827_00 961827_00 961827_00 961827_00 961827_00 6 88 961827_00 6 6 6 6 6 6 8 6 8 8 8 6 +2 4 6 6 961827_00 6 DC ou 24V max. 20 6 5 8 3.3 +2 4 6 6 8 961827_00 5 10 6 6 AC in +2 4 ~1x230V 50/60 H 6 17.10.2014 ts Freigabe 17.10.2014 ts signal signal Änd.Index 00 961827_00 6 00 Änd.Index 00 DC ou 24V max. 20 6 TD-0028423 8 PDM_Nr Zeichnungsnummer 961828 ts TD-0028419 Änd.IndexZeichnungsnummer 5 geprüft 961808 geprüft stationary impeller Zeichnungsnummer II I 8 6 52 54 51 52 54 51 Ersatz für:operating Massstab gezeichnet 13.11.2014 52 54 Ersatz für: Ersatz für: fault signal active Ersatz für: DC out 24V 3.3 max. 20mA Ersetzt durch: turning impeller Ersetzt Ersatz für:durch: DC ou 24V DC20 o max. 24VL 51 max. 20 +2 4 6 52 54 51 52 54 51 5 3.3 PDM_Nr TD-0026660 Massstab gezeichnet 13.11.2014 Zeichnungsnummer ts Änd.Index Biral AG CH-3110 Münsingen Biral AG Biral AG 3 3 CH-3110 961827Münsingen 00961827 CH-3110 Münsingen ON 6 66 6 mit FU für BA 2 52 54 51 11 10 The pump has a signal 961828_00 relay with potential-free 11 10 52 N 54 51 L +2544-51 11L10 52 N changeover contact for max. 250V AC max. 250V AC AC in AC in 2A external fault notification. ~1x230V ±10%2A ~1x230V ±10% min. 5V DC min. Hz 5V DC 20mA 20mA The signal50/60 relay can be 50/60 Hz switched over to operation notification via switch 1. 1:2 CH-3110 Münsingen Freigabe 5252 5454 51signal 51 operating active inactive Relaisaugänge1:1 51,52,54 5 Massstab gezeichnet 16.10.2014 ts Impeller red ON operating signal ON2 ModulA 8 6 6 8 6 Visum fault signal inactiveBiral AG1:1 Klemme 11, 10 961827 CH-3110 Biral AG Münsingen Biral AG Biral AG Münsingen CH-3110 Zeichnungsnummer CH-3110 Münsingen Änd.Index Datum Visum Münsingen 961827 Visum AG Münsingen Biral Ersetzt Ersetzt durch:5252 für: durch: 54 CH-3110 51 52 54 CH-3110 51 51 Ersatz II I CH-3110 Münsingen 54 961827 Relaisaugänge N 5 8 8 6 Datum ModulA 5252 5454 5151 Änd.Index Datum Ersetzt durch: Änd.Index Datum Änd.Index Datum AC in ~1x230V ±10% 50/60 Hz Anschlussschema Visum Ersetzt durch: stationary ON impeller ON L 5 5 10 ModulA BG2 1 2 3 Datum N NN 66 6 6 6 DC out 24V max. 20mA L N +2 4- Ersetzt Ersatz für: Ersetzt durch: für:durch: Massstab Ersatz gezeichnet 13.11.2014 ts Massstab gezeichnet 13.11.2014 ts IIIIVisum II ModulA Ersetzt durch: Ersatz für: geprüft Massstab 1:1 gezeichnet 1:1 geprüft gezeichnet 13.11.2014 13.11.2014 ts ts Massstab ModulA gezeichnet 13.11.2014 ts Massstab ModulA Relaisaugänge ModulA Relaisaugänge Freigabe geprüft MassstabFreigabe gezeichnet 13.11.2014 ts1:1 geprüft geprüft ModulA 51,52,54 51,52,54 Relaisaugänge1:1 Relaisaugänge PDM_Nr TD-0028419 PDM_Nr TD-0028419 Relaisaugänge Freigabe geprüft Freigabe Freigabe 1:1 51,52,54 Änd.Index 961865_01 Relaisaugänge Zeichnungsnummer Änd.IndexZeichnungsnummer 51,52,54 51,52,54 PDM_Nr TD-0028419 Freigabe TD-0028419 PDM_Nr TD-0028419 Biral AGPDM_Nr Biral AG Zeichnungsnummer Änd.Index 51,52,54 Zeichnungsnummer Änd.Index Zeichnungsnummer Änd.Index PDM_Nr TD-0028419 00 961827 00 Änd.Index L LL 8 II I 52signal 5454 5151 fault 52 5252 5454 51 252 52 5451 51 active Visum 5 N 54 51 52 Betrieb EIN 5 Impeller green 52 54 51 52 54 51 Änd.Index Datum 52 54 51 turning impeller 52 54 51 Datum Visum 52 54 51 II I 52+2544-51 11L10 Betrieb AUS Betrieb AUS Status Änd.Index II I Impeller ON red 52 54 51 52 54 51 52 52154 54 51 51 1 ON inactive 00 ON 5 11 10 ON 52 54 51 Impeller green ON 5 3.3 3.3 3.3 out max. 250V AC AC inmax. 250V ACDC 24V AC in 2A ~1x230V ±10%2A max.~1x230V 20mA 10±10% min. 5V DC 50/60 min. Hz 5V DC 50/60 Hz 20mA 20mA 11 10 Connection 52 54 51 5252 5454 5151 5254 5451 51 52 54 51 Status 5252 10.12.2014 nma 3:154 geprüft 52 51 52 52 5454 5151 10.12.201452 nma54 51 52 54 Freigabe 51 52 54 51 52 54 51 52 52 54 51 52 52Zeichnungsnummer 54PDM_Nr 51 TD-0028816 5254 5451 51 fault signal Änd.Index 961865 OFF 11 10 8 Betrieb EIN Ersatz für: CH-3110 Münsingen 5 5 +2 4- Massstab gezeichnet 10.12.2014 nma Switch 1 Biral AG OFF 5 5 8 8 8 6 6 8 11 10 +2 4- OFF 6 Ersetzt durch: fault signal Switch 3 Visum 6 6 6 6 6 6 6 11 10 External 961808_00 Datum 8 66 66 6 8 6 8 8 ON Switch 2 Extern EIN Änd.Index ModulA Power Limit AC max.max. 250V250V AC AC AC inmax. Klemmen AC in AC in250V 5 2A 2A 2A5 ~1x230V Ausganslage DC out gebrückt ±10% 10% ±250V ±max. AC ~1x230V ~1x230V 10% max.DC 250V AC 250V AC out ACininHz AC in max. AC min. 250V 5V DC min. 5V DC 5max. 24V min. 5V DC AC 5 50/60 50/60 2A Hz 2A 2A 5Hz 24V 3.3 5 ~1x230V ±10% ~1x230V50/60 20mA ±10%2A 20mA max. 20mA 10 20mA ~1x230V ±10% 10 3.3 DC min. 5V 5V min. 5V DC min. 5V20mA DC max. 50/60Hz Hz DC 50/60 min. Hz 50/60 20mA 20mA 20mA 20mA 5.4.1 Switch 1, Fault or operating signal (switchable) 52 54 54 51 51 52 DC out 5 24V 5 DC out3.35 5 10 3.3out max. 20mA DC 24V 5 10 24V 3.320mA 10 max. max. 20mA 11L 10L N 52 54 524-51 54 51 N 51 +2 +2 4- 4-11 11 10 1052+2 54 +2 411L10 10 52 52 54 51 51 +2 4-4- 11 111010 52 52+2 54451 N 54 +2 54 51 External ON 11 Bold lettering = as delivered Connection 52 54 51 5 8 Switch 2 5 6 Clamps fault signal 52, 54, 51 OFF 5 10 10 6 OFF 961865_00 Switch 3 5 5 6 1 2 3 Clamps operating signal 52, 54, 51 Extern AUS ON ON DC out DC out 24V24V5 10 DC out max. 20mA or DC out External OFF max. 20mA 24V 24V max.20mA 20mA max. Switch External ON 6 6 Fault or operating signal 88 Switch 2 6 Switch 1 Function english | 23 5.4.2 Switch 2, external OFF or externalKlemmen ON (switchable) DC out Ausganslage 24V max. 20mA ConnectionStatus Switch 2 Switch 2 4+2 11 11 10 10 52 54 51 DC out 24V 2OFF max. 20mA 11 10 operation Betrieb EIN AUS 11 10max. 250V AC Betrieb EIN 3 ON Datum Visum 01 16.01.2015 ts ModulA 33 Switch ON 3 Ersetzt durch: 16.01.2015 ts 3:1 Freigabe TD-0028816 Zeichnungsnummer Änd.Index 01 961828_00 Ersatz für: Massstab gezeichnet 10.12.2014 nma 3:1 3 ts Freigabe Ersetzt durch: AC in Biral AG Massstab gezeichnet 10.12.2014 nma 961865 CH-3110 Münsingen ~1x230V ±10% geprüft Änd.Index 3:1 Freigabe PDM_Nr ModulA 961865 Ersetzt durch: Klemme 10durch: L NVisum 11,Ersetzt Datum 961808_00 Ersatz für: Massstab gezeichnet 13.11.2014 01 Ersatz für: 1:1 ±10% Änd.Index Datum mit FU für BA~1x230V 50/60 Hz II I Freigabe Biral AG ModulA PDM_Nr TD-0026660 Ersetzt durch: Ersatz für: Zeichnungsnummer Änd.Index Massstab gezeichnet 13.11.2014 CH-3110 Münsingen Visum 11, 10 Klemme Ersetzt durch: Datum ModulA BG2 Anschlussschema mit FU für BA TD-0028423 Massstab gezeichnet 16.10.2014 ts Power limit ON Zeichnungsnummer Biral AG geprüft 17.10.2014 ts 1:2 setting range CH-3110 Münsingen Freigabe 961828 17.10.2014 ts Visum 961808 1:1 Ersatz für: 00 Änd.Index 00 ts geprüft Freigabe PDM_Nr TD-0028423 Massstab gezeichnet 16.10.2014 ts Zeichnungsnummer Änd.Index Biral AG 1:2 geprüft 17.10.2014 ts Freigabe 961828 17.10.2014 ts CH-3110 Münsingen PDM_Nr Biral AG CH-3110 Münsingen ts geprüft PDM_Nr AC in Anschlussschema I Visum Änd.Index ModulA BG2 Änd.Index 01 TD-0028816 Zeichnungsnummer Biral AG CH-3110 Münsingen Änd.Index Datum 50/60 Hz II I I geprüft PDM_Nr TD-0028816 Ersatz für: Zeichnungsnummer Änd.Index 961808_00 Visum 5 5 TD-0026660 Zeichnungsnummer 961808 11 10 Änd.Index 00 00 10 11 10 8 geprüft 961865 L N Ersetzt durch: Betrieb EIN Massstab gezeichnet 10.12.2014 nma 3 Biral AG CH-3110 Münsingen Visum 961828_00 Ersatz für: PDM_Nr Datum Betrieb AUS +2 46 Extern EIN ON Änd.Index max. 20mA 961828_00 5.4.3 Switch 3, power limit (can be activated) • ON ON1 2 3 The power limit (volume flow limit V ) Switch 2 11 10 11 10 961865_01 can be activated in the pump. 3 10 5 6 11 10 2A min. Betrieb 5V DC AUS 20mA OFF ON 2 ON 1 2 3 ON 961865_01 3 24V max. 20mA Note: If no external ON/ OFF switch is connected, the pump runs if switch 2 +2 and 4is in the OFF position no bridge is plugged in at terminals 11 or 10. This is 5 DC out the factory setting. 24V 8 11 11 10 10 52 54 51 operation Betrieb AUS EIN 2 Switch 2 961865_01 ON 2 ON 1 gebrückt min. 5V DC 20mA 6 ON 2 ON 1 2 3 ON 1 ON max. 250V AC Ausganslage 2A 8 ON SwitchON Switch 2 ON +2 2 4- 2 6 external ON ON Extern Extern EIN AUS 1 Switch 1 6 ON operation Betrieb AUS KlemmenAUS 6 ON 11 10 operation ON EINBetrieb EIN 6 OFF Digital input The digital input can be used for external ON/OFF switching of the pump. Using switch 2, it is possible to switch over from external 5 OFF to external ON. DC out 6 external OFF Extern AUS ON gebrückt ConnectionStatus 5 8 Switch The pre-set maximum volume flow is at the end of characteristic curve 3 (proportional pressure). The volume flow limit can be set from 25 … 90 % via Biral Remote. 5 24 | english 6. Start-up 6.1 General Before start-up, it is vital that the unit is filled with the delivery medium and ventilated. Close to the inlet nozzles of the pump, it should also be the required minimum intake pressure. The system can be ventilated via the pump. The pump itself is self-ventilating. 6.2 Operational control Pumpe steht. Störung (Problemfälle) After switching on the power supply the pump must start up independently: the Biral Pumpe steht. Störung (Problemfälle) Pumpe läuftimpeller normal turns and flashes green. Drehung Muster b Farbe ro Drehung drehend Muster normal Farbe grün The pump runs according to basic settings (see paragraph 7.9). Pumpe läuft. Störung (Problemfälle) Pumpe Extern OFF Drehung stehend Muster blitzend Farbe grün Drehung Muster n Farbe ro Pumpe START/STOP von Taste oder App Drehung stehend Muster normal Farbe grün ModulA-...D mit BIM A2 Siganlmodul Doppelpumpe (Pumpe aktiv) Drehung drehend Muster normal Farbe grün Doppelpumpe (Pumpe passiv) Drehung stehend Muster blitzend Farbe grün Betriebskontrolle Änd.Ind Modu Bira 961568_00 english | 25 7. Settings Warning There is a risk of burning! For high media tempe ratures the pump may become so hot that only the keys may be touched. 6.3 3.2 1.6 0.8 N9 N8 N7 N6 6.3 3.2 1.6 0.8 N9 N8 N7 N6 7.1 Control panel A1Control panel for setting the type of control (see para. 7.2) A2Keys for setting (delivery height) with illuminated symbols (LED) to display delivery height and delivery flow, (see para. 7.3) 0.4 Allgemeintoleranzen ISO 2768-mK N5LED 1 Display control curve characteristics set (phase) über 6 bis 30 über 30 bis 120 über 120 bis 400 über 400 bis 1000 • 0.5 bis 6 LED 2 Display the delivery height V (25…100%) ± 0.2 ±current 0.3 ± 0.5 ± 0.8 ± 0.1 0.4 LED 3Biral impeller displays the status of the pump Allgemeintoleranzen ISO 2768-mK N5 (see para.über7.9) über 6 bis 30 30 bis 120 über 120 bis 400 über 400 bis 1000 0.5 bis 6 ± 0.2 ± 0.3 ± 0.5 ± 0.8 Rauhwerte Ra 12.5 B ± 0.1 Socket for Remote Adapter Rauheitsklassen N10 6.3 3.2 1.6 0.8 0.4 Allgemeintoleranzen ISO 2768-m N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 6.3 3.2 1.6 0.8 0.4 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 40 ± 0.5 Allgemeintoleranzen ISO 2768-mK 7.2 Types of control N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 Operating key Controlled operation: proportional pressure (pp) may be used in the following systems: – Dual pipe systems with thermal valves and • Long stretches of pipe • Valves with large working area • High pressure loss – Primary circulation pumps with high pressure loss Cycle of the control type Controlled operation: constant pressure (cp) may be used in the following systems: – Dual pipe systems with thermal valves and • Delivery height >2m 961204_00 • Natural circulation – With very low pressure loss – Primary circulation pumps in systems with low pressure loss 961204_00 – Floor heating with thermostatic valves – Single pipe heating Non-controlled operation: constant speed (cs) The operating point can be optimally set by adjusting the speed (key A2) optimal. 961204_00 May be used for systems with constant volume flow: air-condi tioning applications, heat pumps and boiler feed pumps, etc. Stück Pos genstand Datum Visum 52 ab 2009 egenstand Material Ersetzt durch: Pos Datum Visum ngsart Zyklus Ersetzt durch: Material Biral AG ngsartCH-3110 Zyklus Münsingen Pos Datum Visum Biral AGErsetzt durch: Material Massstab gezeichnet 07.01.2009 ts 1:1 Modell/Art.Nr Bemerkung geprüft 20.03.2009 ts Ersatz für: Freigabe 20.03.2009 ts PDM_Nr TD-0011003 Massstab gezeichnet 07.01.2009 ts Zeichnungsnummer Änd.Index geprüft 20.03.2009 ts 1:1 961204 Freigabe 20.03.2009 ts00 Modell/Art.Nr Bemerkung PDM_Nr II I Änd.Index Pos Gegenstand Datum Visum Material TD-0011003 Zeichnungsnummer Ersatz für: Änd.Index Modell/Art.Nr B Ersetzt durch: A402 - A652 ab 2009 Ersatz für: 52 ab 2009 genstand Modell/Art.Nr Bemerkung 961204_00 Regelungsart Zyklus BA Biral AG CH-3110 Münsingen Ersatz für: Massstab gezeichnet 07.0 1:1 geprüft 20.0 Freigabe 20.0 PDM_Nr TD- Zeichnungsnummer 961204 26 | english 7.3 Delivery height (A2) The target value of the pump can be set by pressing the key or . Example: LED 3 lights up (green): characteristic curve 3 LED 3 and 4 light up (green): characteristic curve between 3 and 4 If any radiators are not sufficiently hot, set the next highest characteristic line. • 7.4 Display of the current delivery height (LED V ) • V = 25, 50, 75, 100% 7.5 Summary of maximum delivery height and delivery amount ModulA… • Hmax [m] Vmax [m3 / h] ModulA 32F-12 220, ModulA-D 32F-12 220 12 17 ModulA 40-8 220, ModulA-D 40-8 220 8 18 ModulA 40-10 220, ModulA-D 40-10 220 10 21 ModulA 40-12 250, ModulA-D 40-12 250 12 24 ModulA 40-18 250, ModulA-D 40-18 250 18 28 ModulA 50-6 240, ModulA-D 50-6 240 6 25 ModulA 50-6 270 6 25 ModulA 50-8 240, ModulA-D 50-8 240 8 27 ModulA 50-12 270, ModulA-D 50-12 270 12 33 ModulA 50-18 270, ModulA-D 50-18 270 18 37 ModulA 65-8 270 8 36 ModulA 65-8 340, ModulA-D 65-8 340 8 36 ModulA 65-12 340, ModulA-D 65-12 340 12 33 ModulA 65-15 340, ModulA-D 65-15 340 15 58 ModulA 80-8 360, ModulA-D 80-8 360 8 54 ModulA 80-12 360, ModulA-D 80-12 360 12 57 ModulA 100-12 450, ModulA-D 100-12 450 12 74 english | 27 7.6 Activating / deactivating the control keys By pressing keys and at the same time (for at least 3 seconds) all function keys on the control panel are deactivated or activated. 7.7 START / STOP pump Press to change the control mode to START or STOP respectively (3 seconds). 7.8 Activate / deactivate dry running detection By pressing the button at the same time, , and (for 10 seconds) the dry running detection is activated or deactivated. 1. Remove any BIM 2. Switch on pump 3. Ensure that the pump is not on «stop» operation 4. Make sure there is no current flow through the pump 5. Deactivate the key lock 6.Press all three buttons for 10 seconds (10 seconds corresponds with 8 – 9 rotations of the impeller) • A short interruption when pressing can lead to the key lock being switched on or the pump being switched to «stop» operation 7.If the impeller turns two segments, dry running operation is deactivated / if the impeller turns one segment, dry running operation is activated. 8.Module or external signals can be connected again. If the pump is really running dry for deactivated dry running detection, it will not register an error and may run defectively. Dry running detection can only be deactivated if the pump is running in fault-free operation and no Biral Interface Module (BIM) is plugged in. 28 | english Pumpe steht. Störung (Problemfälle) Pumpe läuft normal Pumpe steht. Störung (Problemfälle) Drehung drehend Muster normal Farbe grün Pumpe läuft normal Pump Pumpe läuftrunning normal Drehung drehend drehend Drehung green Muster normal Muster normal Drehung stehend Farbe grün Farbe Mustergrün blitzend Farbe grün Drehung stehend Drehung stehend green Muster Muster normal blitzend Farbe Farbe grün grün Pumpe Extern OFF Pumpe von Taste oder App Steuer, START/STOP PWM, Hoval. Pumpe gestoppt drehend ormal Pumpe Extern Extern OFF OFF Pumpe Pumpe START/STOP von Taste oder App Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) Pumpe Pumpe START/STOP START/STOP von von Taste Taste oder oder App App ModulA-...D mit BIM A2 Siganlmodul Pumpe steht. Störung (Problemfälle) Doppelpumpe (Pumpe aktiv) Steuermodul BIM B2: Doppelpumpe Pump with fault Pumpe steht. Störung (Problemfälle) (Pumpe passiv) 12.5 6.3 3.2 1.6 0.8 0.4 ehung drehend N10 N9 N8 N7 N6 uster normal rbe grün ModulA-...D mit BIM A2 Siganlmodul Allgemeintoleranzen ISO 2768-mK N5 0.5 bis 6 über 6 bis 30 über 30 bis 120 ± 0.2 (Pumpe± aktiv) 0.3 ± 0.1 Doppelpumpe über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 Drehung Drehung stehend stehend Muster blitzend green Muster blitzend Drehung stehend Farbe grün grün Farbe Muster normal Farbe grün Drehung drehend green Muster blitzend Farbe grün Drehung Drehung drehend stehend Muster Drehung stehend Muster normal blitzend rotgrün Farbe Muster blinkend Farbe grün Farbe rot Doppelpumpe Doppelpumpe (Pumpe (Pumpe aktiv) aktiv) Doppelpumpe (Pumpe passiv) Doppelpumpe (Pumpe (Pumpe passiv) passiv) Doppelpumpe Betriebskontrolle Proportional Pumpe Störung Pattern Status Pumpe steht. steht. Movement Störung (Problemfälle) (Problemfälle) 961568_00 flashing still drehend Muster normal Pump, externalDrehung OFF Muster normal Farbe rot rot Farbe ModulA-D … (pump passive) flashing turning Pump controlled externally Pump STOP from key or Remote, see para. 7.7 (pump still) Steuer, PWM, PWM, Hoval. Hoval. Pumpe Pumpe ge ge Pumpe läuft. läuft. Störung Störung (Problemfälle) (Problemfälle) Steuer, Pumpe PDM_Nr Pos Gegenstand Visum Material A652 ab 2009 elungsart Zyklus Biral AG CH-3110 Münsingen ... flashing still Drehung drehend Alarm(operating Steuermodul BIM BIM B2: B2: Doppelpu Doppelpu Mustersignal: blitzend OFF) Steuermodul Farbe grünON) (fault signal: ... normal turning Warning gestoppt Steuer, PWM, Hoval. Pumpe (operating signal: ON)... (fault signal: ON) Drehung stehend Muster blitzend Farbe grün ... ... ... Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) Drehung drehend Muster blitzend ... ... Farbe grünDatum Änd.Index Visum Biral Änd.Index Impeller Datum Drehung stehend Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) Muster blitzend Farbe grün Visum Änd.Index Änd.Index Biral AG ... Datum Datum Drehung ... Muster ... ModulA ModulA Farbe ... 09.04.2013 ts TD-0021556 Biral Biral Impeller Impeller Änd.Index 00 Visum Visum Biral Biral AG AG CH-3110 Münsingen Münsingen CH-3110 Drehung ... Muster ... Farbe ... Ersatz für: 20.03.2009 ts Freigabe 20.03.2009 ts PDM_Nr TD-0011003 Zeichnungsnummer 961204 Änd.Index 00 Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 12.02.2013 ts ModulA 1:1 Biral Impeller Biral AG CH-3110 Münsingen geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021556 Zeichnungsnummer 961568 Ersetzt durch: Ersetzt durch: Biral AG CH-3110 Münsingen Massstab gezeichnet 07.01.2009 ts geprüft Ersetzt durch: Biral Impeller CH-3110 Münsingen Modell/Art.Nr Bemerkung 1:1 Ersetzt durch: ModulA ... Ersetzt durch: Steuermodul BIM B2: Doppelpu Steuer, PWM, Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. 09.04.2013 ts 961568_00 Steuermodul BIM B2: Doppelpu Steuermodul Steuermodul BIM BIM B2: B2: Doppelpu Doppelpu Steuermodul BIM B2: Doppelpu ModulA Zeichnungsnummer SWITCH Power limit OFF Biral AG 3 OFF 961568_00 See para. 5.5.3 961568 CH-3110 Münsingen ehung stehend uster blitzend rbe grün Datum Drehung drehend Zusatzmodule Control characteristic curve set at 3 LED lights up green Betriebskontrolle 961204_00 Betriebskontrolle 961568_00 SWITCH 2 External OFFgeprüft 1:1 Freigabe OFF See para. 5.5.2 l Impeller ehung drehend uster normal rbe grün Steuermodul BIM B2: Doppelpu still Massstab gezeichnet 12.02.2013 ts lA Steuer, PWM, Hoval. Pumpe ge normal Visum SWITCH 1 durch: Fault signal Ersatz für: Ersetzt OFF See para. 5.5.1 Datum Steuer, Steuer, PWM, PWM, Hoval. Hoval. Pumpe Pumpe au au Drehung stehend stehend runningDrehung normally Muster blinkend Muster blinkend Drehung Farbe rot drehend ModulA-D … (pump active) Farbe Musterrot normal Farbe rot Farbe grün Betriebskontrolle Steuer, PWM, Hoval. Pumpe ge Zusatzmodule Zusatzmodule Pumpe läuft. Störung (Problemfälle) normal turning Pump pressure Drehung stehend stehend Drehung Muster blitzend blitzend Muster LED lights up yellow Farbe grün 3 ex Steuer, PWM, Hoval. Pumpe au Drehung stehend Muster blinkend Farbe rot Drehung drehend Muster normal Farbe rot Pumpe läuft. Störung (Problemfälle) Pumpe Pumpe steht. steht. Störung Störung (Problemfälle) (Problemfälle) ... 7.10On-site adjustment of the pump ehung stehend uster normal rbe grün Zusatzmodule Pumpe steht. Störung (Problemfälle) Drehung Drehung stehend stehend Muster Muster normal normal Farbe Farbe grün grün Drehung drehend rot normal Muster Farbe grün Drehung Drehung stehend ... Muster Drehung Muster blitzend ...drehend Farbe Muster Farbe grün ...normal Farbe rot Drehung Drehung drehend drehend Muster normal Muster normal Drehung stehend Farbe grün Farbe Mustergrün blitzend Farbe grün Drehung ... Muster ... Farbe ... Doppelpumpe (Pumpe passiv) ... ModulA-...D mit BIM BIM A2 Siganlmodul Siganlmodul ModulA-...D Pumpe läuft.mit StörungA2 (Problemfälle) ehung stehend uster blitzend rbe grün x (control operat.) Farbe grün Drehung Drehung stehend drehend Muster blitzend Muster blitzend Colour Farbe Farbe grün grün Steuer, PWM, Hoval. Pumpe au Drehung stehend Muster blinkend Farbe rot Pumpe steht. Störung (Problemfälle) Pumpe läuft normal Zusatzmodule 7.9 Biral impeller drehend Shows the status of the pump: Drehung normal Steuer, PWM, Hoval. (cs) oder Max. Pumpe Extern OFF Pumpe auf Min, Normaler BetriebMuster stehend inkend Zusatzmodule Änd.Index 00 english | 29 8. Fault summary and checklist Warning Before starting to rectify faults, it is vital that the pump is taken out of operation, and it must be r emoved from the mains at all poles and safeguarded from being switched on again. This should only be carried out by specialist staff. Accessible voltage! Risk of scalding from escaping medium. Zusatzmodule Steuer, PWM, Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Drehung drehend Muster blitzend Drehung stehend Muster blinkend Farbe rot grün Risk of burning Farbe from hot surfaces. Pumpe steht. Störung (Problemfälle) Steuer, läuft PWM, Hoval. Pumpe gestoppt Pumpe normal Zusatzmodule Steuer, PWM, Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Pumpe steht. Störung (Problemfälle) Drehung stehend Drehung drehend Muster blitzend Muster normal Farbe grün Drehung drehend Muster normal Farbe rot Drehung drehend Muster blitzend Farbe grün Drehung stehend Muster blinkend Farbe rot Farbe grün Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) If noPumpe Remote Adapter is available, thePumpe listläuft.below should be followed step by step from Steuer, PWM, Hoval. Pumpetop gestoppt Störung (Problemfälle) Extern OFF Drehung drehend Drehung drehend Drehung stehend Muster blitzend Muster normal Muster blitzend to bottom. If a Remote Adapter is available, the cause of the fault is displayed direct in the Farbe grün Farbe rot Farbe grün Remote app. Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) Pumpe START/STOP von Taste oder App Fault summary ... 1 Biral Impeller does not light up 2 Biral impeller turns red ... Doppelpumpe (Pumpe aktiv) (warning, pump is turning) Änd.Index Datum ModulA Biral Impeller Drehung stehend Visum Ersetzt durch: geprüft Betriebskontrolle Biral AG CH-3110 Münsingen What to do ... 1. Check sensor plug connection: See operating instructions, section 4.3 2. Replace sensor kit: see ModulA BA sensor kit First measure if no R emote Detection without Remote Adapter Steuer, PWM, Hoval. Pumpe auf Min,Check Normaler Betrieb (cs) oderthe Max. pump ... is set to stop operating Adapter is available. 1. whether Drehunginstruction, drehend (see operating section 7.7) Muster blitzend 2. If yes, the Biral impeller starts to rotate red Farbe grün (see «sensor communication fault»), otherwise 12.02.2013 ts it is another fault. 09.04.2013 ts 3. Check power supply Drehung stehend PDM_Nr Farbe TD-0021556 rot Zeichnungsnummer Änd.Index (74) Overvoltage (*) Farbe grün 4. Check power supply Änd.Index Datum Undervoltage 00 operation Turbines Muster blitzend Visum Ersetzt durch: Ersatz für: Detection without Remote Adapter Massstab gezeichnet 12.02.2013 ts 5.Switch off the pump at the main switch. If the 1:1 geprüft 09.04.2013 ts Drehung drehend Biral Impeller 09.04.2013 ts Freigabe Muster blitzend Biral impeller flashes red, the pump is running Farbe grün PDM_Nr TD-0021556 in «Turbines operation» operating mode, Zeichnungsnummer Änd.In Biral AG otherwise it is another fault. Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv)ModulA 961568_00 CH-3110 Münsingen Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) ... 961568 What to do Drehung stehend Muster blitzend 6. Check whether the return valve in the equipment Farbe grün is defective. If necessary check the return valve. 7. Check whether the return valve is installed in the right place in the equipment. Drehung ... Muster ... Farbe ... Drehung drehend Muster normal Farbe grün ... Drehung stehend Muster blitzend Farbe grün Drehung ... Muster ... Farbe ... Steuer, PWM, Hoval. Pumpe gestoppt drehend 09.04.2013 ts Freigabe Drehung 961568 Drehung stehend Muster blitzend Farbe grün Drehung ... Muster ... Farbe ... Drehung stehend Muster blitzend blinkend Farbe grün rot Muster normal Muster blitzend Farbe grün Drehung stehend Muster normal Farbe grün Check power switch and fuses Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) Check power socket and cable Zusatzmodule Massstab gezeichnet 1:1 No power supply Sensor communication fault Ersatz für: Pumpe läuft. Störung (Problemfälle) Rectification Drehung ... Drehung Muster ...drehend Muster Farbe ...normal Farbe grün 3 Biral impeller flashed red Pumpe steht. Störung Doppelpumpe (Pumpe(Problemfälle) passiv)turning) (alarm, pump not Drehung drehend Muster blitzend Farbe grün Cause Drehung ... Muster ... Farbe ... Pumpe steht. Störung (Problemfälle) Drehung drehend Muster normal Farbe grün Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) Drehung stehend Drehung stehend Muster blitzend Muster normal Farbe grün Farbe grün ModulA-...D mit BIM A2 Siganlmodul Drehung stehend Muster blitzend Farbe grün Drehung ... Muster ... Farbe ... 00 30 | english Fault summary Pumpe steht. Störung (Problemfälle) 3 Biral impeller flashed red Pumpe steht.pump Störung (Problemfälle) (alarm, not turning) Cause Drehung stehend Muster blinkend Farbe rot Drehung drehend Muster normal Farbe grün Drehung drehend Muster normal Farbe rot Drehung stehend Muster normal Farbe grün Drehung drehend Muster normal Farbe grün Drehung stehend Muster blitzend Farbe grün Rectification Detection without Remote Adapter Steuer, PWM, Hoval. Pumpe auf Min, Switch Normaler Betrieb Max. at the main switch and turn it 8. off (cs) theoder pump drehend after power ON, 3 attempts on again. Drehung 3 seconds Muster blitzend are made Farbe at unblocking. The fault relay switches on grün and the Biral impeller flashes red after 20 seconds, otherwise it is another fault. Steuer, PWM, Hoval. Pumpe gestoppt Pumpe läuft. Störung (Problemfälle) Drehung stehend Muster blitzend Farbe grün Zusatzmodule Motor blocked Drehung stehend What to do Muster blitzend Farbe grün 9.Remove pump head (see ModulA BA motor) 10.Remove any foreign bodies that are present. 11. C heck impeller and if the impeller is defective, Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) change motor. Drehung drehend Muster blitzend 12.If the impeller is working, install pump head again. Farbe grün (See ModulA BA Motor) Dry runningSteuermodul BIM B2: Doppelpumpe Detection without Remote Adapter (Pumpe passiv) 13.Set constant speed stage 1 and let it run for Drehung stehend blitzend at least a Muster minute. Farbe grün 13.1. If the impeller turns red, it is another fault. 13.2. If the impeller remains green, go to the next ... point. Drehung ... 14.Set constant speed stage 6 and leave to run Muster ... ... minute. for at leastFarbe one 14.1. If a fault is displayed within the first minute, it is another fault. ... 14.2. If the impeller changes to red after a minute, Drehung ... it is clearly Muster ... a dry running alarm. Farbe ... Änd.Index Datum Visum Ersetzt durch: ModulA Biral Impeller There are various possible causes for a dry running alarm: – Air in the system (actual dry running – equipment is not filled or ventilated) –H igherErsatz pressure on the suction side than the für: pressure side gezeichnet 12.02.2013 ts –F Massstab ault alarm due to an incorrect measurement 09.04.2013 ts 1:1 geprüft (sensor blocked, sensor hole in the casing blocked, 09.04.2013 ts Freigabe sensorPDM_Nr coverTD-0021556 incorrectly mounted, sensor damaged) Zeichnungsnummer Biral AG to do 961568 CH-3110 Münsingen What Änd.Index 00 15.Check whether the equipment is filled with water. 16.Check whether there are air bubbles in the system (noises). 17.Press any button to acknowledge the fault. 18.Set stage 6 constant speed function check and leave it to run for a minute. If possible, against the open and closed valve. 19.If the impeller changes to red again after a minute, there is still a dry running alarm. 20.Provided the equipment is filed and correctly ventilated the dry running alarm may be a fault alarm, triggered by an incorrect measurement. 21.Change the sensor or contact Biral SERVICE. Internal fault (*) – ( 10) Communication fault –H ardware fault –M emory access fault –F ault with power on current –R TC fault 22. C hange the ModulA electronics or ask Biral SERVICE for support. Check whether the pump runs in turbine operation (see turbines operation) or has flow through. en english | 31 9. Sensor For maintenance work on the sensor or when changing the sensor, the Sealing cap must be placed correctly on the sensor casing. Warning Before changing the sensor, the pump must be switched off and the system without pressure. X 5Nm 961612_00 X Nose must be facing downwards. Tighten the screw to affix the clamp at 5 Nm. 5Nm II I Änd.Index Datum Visum Ersetzt durch: Massstab gezeichnet 08.04.2013 ts ModulA Montage Sensor BA Biral AG CH-3110 Münsingen Ersatz für: Massstab gezeichnet 08.04.2013 ts 1:3 geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0022120 Zeichnungsnummer 961612 Ersatz für: Änd.Index 00 1:3 geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0022120 Zeichnungsnummer 961612 Änd.Index 00 32 | english 10. Accessories / versions 10.1 Biral Remote Biral Remote enables configuration and analysis of ModulA. Wireless communication is via a Wi-Fi connection with ModulA, which is fitted with an interface for the Biral Remote adapter. Biral Remote APP The Biral Remote app can be downloaded free of charge from iTunes and Play-Store. It only works with the relevant Biral Remote adapter (hardware). Adjustment options and information (extract) Info Pump type Status Delivery volume Configuration Type of operation Medium temp. Control type · Software version · [m³ / h] · Serial number · Manufacture date Delivery height · [m] · Time · [°C] · Operation, on · Operation, top · Minimum speed · Maximum speed Output · [W] · Proportional pressure · Constant pressure · Constant speed Speed Target value · [ / min] 1 Control type · Setting control · characteristic curve Current alarm Current alarm · Communication fault · Internal fault · Over-voltage · Under-voltage · Forced delivery · Dry running Pump blocked Current warning · Sensor error · Internal fault Alarm log 1 Alarm log 2 ·P roportional pressure Power Limit: · Setting, delivery (pp) Warning log 1 volumes-limit ·C onstant pressure (cp) 25% … 90% von Q_max Warning log 2 ·C onstant speed (cs) Target value Pump number · pp, cp [m] · cs [%] · Definition · Pump number for BUS identification Operating hours Key lock · [h] Electr. energy · [kWh] · Lock keys · Keys unlocked Time · Setting of internal pump time Biral Remote Adapter The Biral Remote adapter is fitted with Wi-Fi and is required for wireless communication between smart phone and pump. Remote Adapter APP english | 33 10.2 B iral interface module, BIM A2 signal module (for self-regulating pumps) –– Operations or ready signal –– External minimum speed –– Dual pump function Note: Not possible in combination with control module Connection drawing 10, 13 External minimum speed with closing contact 61, 64Operations or ready signal (can be switched over) As a closing contact: closes on operation / ready signal 61, 62Operation or ready signal (can be switched over) As an opening contact: opens for operation / ready signal 91, 92 Dual pump function 961561_00 91 92 13 10 61 62 64 max. 250V AC 2A min. 5V DC 20 mA 10.3 Biral interface module, BIM B2 control module (for controlled pumps) –– External speed specification, 0 –10 V / 0 – 20mA –– PWM/multitherm interface –– Dual pump function Note: Not possible in combination with signal module Änd.Index Datum Visum Ersetzt durch: Ersatz für: Connection drawing II I Massstab gezeichnet 25.01.2013 ts 81, 82 Multitherm / PWM interface for external speed specification ModulA 961562_00 1:1 geprüft 12.02.2013 ts Anschlusschema 81 82 71 72 91 92 71, 72Analogue input 0…10 V or 0…20 mA for external speed Freigabe 12.02.2013 ts BIM A2 PDM_Nr TD-0021438 specification Zeichnungsnummer Änd.In Biral AG 91, 92 Dual pump function 00 961561 CH-3110 Münsingen 10.4 Heating and domestic hot water version II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 25.01.2013 ts ModulA Anschlusschema BIM B2 Biral AG CH-3110 Münsingen 1:1 geprüft 12.02.2013 ts Freigabe 12.02.2013 ts PDM_Nr TD-0021440 Zeichnungsnummer 961562 Änd.In 00 34 | english 11. Technical data Supply voltage 1×230 V ±10%, 50/60 Hz, PE Motor protection External motor protection is not required Type of protection IP 44 (EN 60529) Winding category Insulation category F Temperature category TF 110 (EN 60335-2-51) Media temperature –10 °C to +110 °C (ModulA GREEN) Ambient temperature max. 40°C In transportation: –40 °C up to +70 °C Maximum operating pressure The maximum operating pressure is given on the nameplate: PN 6: 6bar PN 10: 10bar PN 16: 16bar Noise Sound pressure level under 43 dB(A) Leakage current The mains filter of the pump causes a leakage current to the earth of <3.5 during operation Power consumption when pump switched off <3W Performance factor cos-phi The ModulA has an integrated performance factor correction filter (PFC). This ensures that cos-phi is always between 0.98 and 0.99 and is therefore kept very close to the ideal value 1. EMV (electromagnetic compatibility) EN 55014-1:2006, EN 55014-2:1997, EN 61000-3-3:2008 and EN 61000-3-2:2006 12. Disposal This ModulA circulation pump was developed with sustainability in mind. This also includes waste prevention and recyclability of materials. This product as well as its parts must be disposed of according to the local regulations. english | 35 13. Spare parts list 6 3 1 7 961872_00 4 5 8 2 1 Biral item no. Stück ModulA… Pos. 1 Electronics with cover, neutral Pos. 2 Motor with O-ring ModulA 32F-12 22 0300 0150 22 0404 0150 ModulA 40-8 22 0300 1650 22 0404 0250 ModulA 40-10 22 0300 0250 22 0404 0250 ModulA 40-12 22 0300 0350 22 0404 0350 ModulA 40-18 22 0300 0450 22 0404 0350 ModulA 50-6 22 0300 0550 22 0404 0450 ModulA 50-8 22 0300 1750 22 0404 0450 ModulA 50-12 22 0300 0650 22 0404 0550 ModulA 50-18 22 0300 0750 22 0404 0750 ModulA 65-8 22 0300 0850 22 0404 0850 ModulA 65-12 22 0300 0950 22 0404 0850 ModulA 65-15 22 0300 1050 22 0404 1050 ModulA 80-8 22 0300 1150 22 0404 1150 ModulA 80-12 22 0300 1350 22 0404 1150 ModulA 100-12 22 0300 1550 22 0404 1150 II I Pos Gegenstand Änd.Index Datum Visum Material Ersetzt durch: Modell/Art.Nr Bemerkung Ersatz für: Pos. 3 Pos. 5 Pos. 4 ModulA GREEN BG3, BG4 Sensor Kit Cover without 1:3.5Connector Ersatzteilliste screws (L,N, PE) Massstab gezeichnet 17.12.2014 nma geprüft Freigabe PDM_Nr Biral AG CH-3110 Münsingen TD-0028878 Zeichnungsnummer 961872 Änd.Index 00 Biral RED 22 0033 0299 22 0301 0150 Biral GREEN 22 0033 0399 Biral BLUE 22 0033 0499 05 9123 9700 36 | english 6 3 1 7 961872_00 2 1 Biral item no. ModulA… ModulA 32F-12 Pos. 6 Insulation kit Stück Pos. 7 O-ring II I Pos Gegenstand Änd.Index Datum Visum ModulA 40-12 00 1503 4600 00 1503 4300 ModulA 50-6 ModulA 50-12 00 1503 4400 05 2544 8499 ModulA 50-18 ModulA 65-8 270 ModulA 65-8 340 ModulA 65-12 00 1503 4500 ModulA 65-15 ModulA 80-8 ModulA 80-12 ModulA 100-12 00 1503 0500 00 1503 0600 22 0069 0100 Modell/Art.Nr Bemerkung Ersetzt durch: Biral AG CH-3110 Münsingen ModulA 40-18 ModulA 50-8 Material Pos. 8 ModulA GREEN BG3, BG4 Assembly kit for Ersatzteilliste wall installation ModulA 40-8 ModulA 40-10 4 5 8 Ersatz für: Massstab gezeichnet 17.12.2014 nma 1:3.5 geprüft Freigabe PDM_Nr TD-0028878 Zeichnungsnummer 961872 Änd.Index 00 espagñol | 37 Contents 1. Instrucciones de seguridad.................................................................................................39 1.1 Generalidades...............................................................................................................39 1.2 Caracterización de las advertencias..............................................................................39 1.3 Cualificación y formación del personal..........................................................................39 1.4 Peligros en caso de inobservancia de las instrucciones de seguridad..........................39 1.5 Trabajo con consciencia de la seguridad.......................................................................40 1.6 Instrucciones de seguridad para el explotador/usuario....................................................40 1.7 Instrucciones de seguridad para los trabajos de montaje, mantenimiento e inspección....40 1.8 Transformaciones y fabricación no autorizadas de piezas de repuesto........................40 1.9 Modos de funcionamiento no autorizados.....................................................................40 2. Símbolos utilizados..............................................................................................................41 3. Información general.............................................................................................................42 3.1 Uso previsto...................................................................................................................42 3.2 Requisitos para el medio transportado..........................................................................42 3.3 Condiciones de funcionamiento.....................................................................................43 3.4 Válvula de retroceso......................................................................................................44 3.5 Protección contra los efectos del congelamiento..........................................................44 3.6 Aislamiento....................................................................................................................44 3.7 Dirección del flujo..........................................................................................................44 4.Montaje..................................................................................................................................45 4.1 Indicaciones generales..................................................................................................45 4.2 Enjuague de la instalación de calefacción (con la bomba quitada)...............................45 4.3 Montaje..........................................................................................................................45 4.4 Posiciones de montaje admisibles.................................................................................46 4.5 Montaje de la bomba en la instalación..........................................................................47 4.5.1 Conexión bridada.................................................................................................47 4.6 Instalación del variador de frecuencia...........................................................................48 4.7 Montaje del enchufe......................................................................................................49 5. Conexión eléctrica................................................................................................................50 5.1 Tensión de alimentación................................................................................................50 5.2 Conexión de la tensión de alimentación........................................................................51 5.3 Diagrama de conexiones Inscripciones de los bornes..................................................52 5.4 Interruptor ajustes..........................................................................................................53 5.4.1 Interruptor 1, aviso de fallo o aviso de funcionamiento (conmutable).................53 5.4.2 Interruptor 2, OFF externo u ON externo (conmutable).......................................54 5.4.3 Interruptor 3, Power Limit (límite de potencia, activable).....................................54 38 | espagñol 6. Puesta en marcha.................................................................................................................55 6.1 Generalidades...............................................................................................................55 6.2 Control de funcionamiento.............................................................................................55 7.Ajustes...................................................................................................................................56 7.1 Panel de mando.............................................................................................................56 7.2 Types of control.............................................................................................................56 7.3 Altura de impulsión (A2)................................................................................................57 • 7.4 Nota del caudal actual (LED V ).....................................................................................57 7.5Vista general de altura de impulsión, caudal de impulsión máximos............................57 7.6 Activar/desactivar teclas de mando...............................................................................58 7.7 Arranque/Parada de la bomba.......................................................................................58 7.8 Activar / desactivar detección de marcha en seco..........................................................58 7.9 La hélice Biral................................................................................................................59 7.10 On-site adjustment of the pump.....................................................................................59 8. Vista general de fallos y lista de comprobación................................................................60 9.Sensor...................................................................................................................................62 10.Accesorio/Variante...............................................................................................................63 10.1 Biral Remote..................................................................................................................63 10.2Biral Interface Module, BIM A2 módulo de señal(para bombas autoreguladas)............64 10.3Biral Interface Module, BIM B2 módulo de control (para bombas controladas)............64 10.4Modelo para agua de calefacción y agua potable doméstica........................................64 11.Datos técnicos......................................................................................................................65 12.Eliminación...........................................................................................................................65 13.Lista de piezas de repuesto.................................................................................................66 espagñol | 39 1. Instrucciones de seguridad Advertencia Este producto sólo puede ser instalado y utilizado por personas con suficientes conocimientos y experiencia. Aquellas personas con limitaciones físicas, intelectuales o disminuidas en su percepción sensorial no deben utilizar este producto, salvo que sean instruidas suficientemente por alguna persona responsable de su seguridad. Este producto debe mantenerse alejado del alcance de los niños. Queda prohibido todo uso de este producto por los niños, p.ej. como juguete. 1.1 Generalidades Estas instrucciones de montaje y de funcionamiento contienen advertencias básicas que han de observarse durante el montaje, el funcionamiento y el mantenimiento. Por esta razón, el montador, el personal técnico responsable y el explotador han de leerlas antes del montaje y puesta en marcha. Estas instrucciones deberán estar siempre disponibles en el lugar de la instalación. Además de las advertencias generales expuestas en esta sección de instrucciones de seguridad, se observarán las instrucciones específicas expuestas en las demás secciones. 1.2 Caracterización de las advertencias Las advertencias colocadas directamente en la máquina, como por ejemplo –– flecha de cambio de dirección –– signo para conexión de fluidos han de respetarse escrupulosamente y se las mantendrán en un estado que permita leerlas con facilidad. 1.3 Cualificación y formación del personal El personal para el montaje, servicio, mantenimiento e inspección deberá estar debidamente cualificado para dichos trabajos. El explotador regulará exactamente la responsabilidad, la competencia y la vigilancia del personal. 1.4 Peligros en caso de inobservancia de las instrucciones de seguridad En caso de inobservancia de las instrucciones de seguridad puede provocarse peligro tanto para las personas como para el medio ambiente y para la instalación. La no observancia de las instrucciones de seguridad puede tener como consecuencia la pérdida de todo derecho de indemnización por daños y perjuicios. La inobservancia de las instrucciones de seguridad puede provocar, en concreto, los peligros siguientes: –– fallo de funciones importantes de la instalación –– fallo de los modelos prescritos para el mantenimiento y conservación –– peligros para las personas por efectos eléctricos y mecánicos 40 | espagñol 1.5 Trabajo con consciencia de la seguridad Se observarán las instrucciones de seguridad contenidas en estas instrucciones de montaje y servicio, las prescripciones sobre prevención de accidentes vigentes en el país, así como las normas de trabajo, funcionamiento y servicio propias del explotador. 1.6 Instrucciones de seguridad para el explotador/usuario Se excluirán los peligros por causa de la energía eléctrica (para detalles sobre este tema véanse, p. ej., las normas NIN (CENELEC) y de las empresas locales de abastecimiento eléctrico). 1.7 Instrucciones de seguridad para los trabajos de montaje, mantenimiento e inspección El explotador deberá cuidar de que todos los trabajos de montaje, mantenimiento e inspección se realicen por personal especializado cualificado, suficientemente informado mediante el estudio profundo de las instrucciones de montaje y servicio. De principio, los trabajos en la instalación se harán siempre con la instalación parada y sin tensión. Inmediatamente después de terminar los trabajos volverán a conectarse o a ponerse en funcionamiento todos los dispositivos de seguridad y de protección. Antes de la nueva puesta en servicio habrán de observarse los puntos presentados en la sección Conexión eléctrica. 1.8 Transformaciones y fabricación no autorizadas de piezas de repuesto La transformación o los cambios en las bombas quedan autorizados únicamente después de consulta con el fabricante. Los repuestos originales y los accesorios autorizados por el fabricante favorecen la seguridad. El empleo de otras piezas puede suponer la inexistencia de responsabilidad por las consecuencias originadas. 1.9 Modos de funcionamiento no autorizados La seguridad de servicio de las bombas suministradas está garantizada únicamente bajo la condición de un uso adecuado a la finalidad prevista, según la sección Finalidad de uso de las instrucciones de montaje y servicio. En ningún caso se superarán los valores límite indicados en los datos técnicos. espagñol | 41 2. Símbolos utilizados Advertencia La inobservancia de estas indicaciones de seguridad puede ocasionar graves lesiones personales. Advertencia Riesgo debido a tensión eléctrica peligrosa. La inobservancia de estas indicaciones de seguridad conlleva el riesgo de que las personas reciban un choque eléctrico capaz de producir lesiones de consideración o incluso la muerte. Advertencia ¡Peligro de lesiones o quemaduras por superficies calientes! Advertencia ¡Peligro de lesiones por objetos que caen! Advertencia Peligro de lesiones por emanación de vapores! La inobservancia de estas indicaciones de seguridad puede tener como consecuencia fallos de funcionamiento o daños materiales. Consejos o indicaciones que alivian la tarea y coadyuvan a una operación segura. 42 | espagñol 3. Información general La serie de modelos ModulA de Biral consta de una serie completa de bombas de circulación, con un variador de frecuencia integrado que permite una adaptación autónoma o controlada del caudal a la demanda real de la instalación respectiva. Con ello, en muchas instalaciones se reduce el consumo de energía y se mejora la regulación de la instalación. Además, se reducen eficazmente los ruidos del paso del agua por la grifería de regulación. Los ajustes necesarios se realizan desde el panel de mando de la bomba. 3.1 Uso previsto Las bombas de circulación Biral de la Serie de modelos ModulA están diseñadas para la circulación de líquidos en las siguientes instalaciones: –– ModulA GREEN en sistemas de aire acondicionado y de refrigeración Pero las bombas también pueden implementarse en los siguientes sistemas: –– Bombas de calor geotérmicas –– Instalaciones térmicas solares Las bombas son apropiadas para funcionar en instalaciones con caudales variables y constantes 3.2 Requisitos para el medio transportado La bomba es adecuada para la impulsión de medios puros, de baja densidad, no explosivos y no agresivos, sin componentes sólidos o de fibras largas capaces de atacar la bomba tanto mecánica como químicamente. –– Agua de calefacción: Requisitos según normas usuales, vigentes para la calidad del agua de instalaciones de calefacción: (p. ej. VDI 2035) –– Glicol: La bomba puede implementarse para la impulsión de mezclas de agua-glicol. Viscosidad máxima admisible: 50 mm²/s (cSt). Esto corresponde a una mezca de agua-etileno-glicol con una componente de glicol de aprox. 50% a –10 °C. La bomba es controlada mediante una función limitadora de potencia, que la protege de sobrecargas. La impulsión de mezclas de agua y glicol influye sobre la característica de MAX, pues el caudal se reduce correspondientemente en función del contenido de glicol y de la temperatura del medio Para que el efecto del glicol no se debilite, deben evitarse temperaturas por encima de la temperatura nominal indicada para el medio. En general, es necesario reducir las horas de servicio en caso de temperaturas elevadas. Antes de agregar la mezcla de glicol, es imprescindible limpiar y enjuagar la instalación. Para evitar corrosión o escoriaciones, la mezcla de glicol debe supervisarse regularmente y, llegado el caso, cambiarse. En caso de necesitar diluir más la mezcla de glicol, deben observarse las indicaciones del fabricante del glicol. Si se trata de impulsar un líquido de densidad y/o viscosidad cinemática diferente a la del agua, el caudal deberá reducirse. espagñol | 43 Advertencia No se debe implementar la bomba para el transporte de medios inflamables, como p.ej. aceite diesel o combustible. Advertencia No se debe implementar la bomba para el transporte de líquidos agresivos tales como ácidos o agua marina. 3.3 Condiciones de funcionamiento –– Temperatura del medio: ModulA GREEN –10 °C a +110 °C –– Presión de servicio: Para presión de servicio máx. admisible, véase la placa de características. (6 bares, 10 bares o 16 bares) Presión de servicio mínima en los tubos de aspiración de la bomba (presión de alimentación) a 500 m sobre el nivel del mar: Temperatura del medio 75°C ModulA … 95°C 110°C Presión de entrada (bares) ModulA 32F-12 220 0.92 1.32 1.92 ModulA 40-8 220 0.12 0.52 1.12 ModulA 40-10 220 0.12 0.52 1.12 ModulA 40-12 250 0.12 0.42 1.02 ModulA 40-18 250 0.12 0.42 1.02 ModulA 50-6 240 0.12 0.12 0.72 ModulA 50-6 270 0.12 0.12 0.72 ModulA 50-8 240 0.12 0.12 0.72 ModulA 50-12 270 0.12 0.42 1.02 ModulA 50-18 270 0.22 0.62 1.22 ModulA 65-8 270 0.22 0.62 1.22 ModulA 65-8 340 0.22 0.62 1.22 ModulA 65-12 340 0.12 0.52 1.12 ModulA 65-15 340 0.42 0.82 1.22 ModulA 80-8 360 0.52 0.92 1.52 ModulA 80-12 360 0.52 0.92 1.52 ModulA 100-12 450 0.52 0.92 1.52 Por ± 100 m de altura ± 0.01 bar –– Temperatura ambiente: 0°C a 40°C 44 | espagñol 3.4 Válvula de retroceso En caso de haberse instalado una válvula de retroceso, la bomba debe ajustarse de tal manera (ver punto 7.2), que la presión de impulsión de la bomba siempre supere a la de cierre de la válvula. Esto debe tenerse especialmente en cuenta en el caso del control de presión proporcional (altura de impulsión menor con caudal decreciente). 961864_00 3.5 Protección contra los efectos del congelamiento Si hay riesgo de heladas durante las paradas de la instalación, deben tomarse las siguientes medidas para evitar daños por congelamiento. 3.6 Aislamiento La bomba puede aislarse junto al sistema de tuberías. A eep the drainage outlet K at the motor free. A Never cover the frequency converter or the control panel with insulation. 3.7 Dirección del flujo La flecha en la carcasa de la bomba indica el sentido de circulación. 961584_00 espagñol | 45 4. Montaje 4.1 Indicaciones generales ModulA está prevista sólo para montaje interior. Las bombas deben montarse libres de tensiones, de tal manera de que no se transmitan fuerzas desde los caños sobre la carcasa de la bomba. La bomba puede colocarse directamente en el caño del fluido, siempre y cuando se haya dimensionado la cañería para soportar el peso de la bomba. Montarla, una vez concluidos todos l os trabajos de soldadura de arco y de estaño en la instalación. Advertencia Se tendrán en cuenta las directivas locales para el izado y desplazamiento de cargas. El peso de la bomba se lee del embalaje. 4.2 Enjuague de la instalación de calefacción (con la bomba quitada) Para evitar interrupciones de servicio indeseables, así como problemas de arranque tras pausas de funcionamiento prolongadas, sugerimos, en caso de una calefacción recién instalada o refaccionada, evacuar la instalación después del primer calentamiento, enjuagarla bien y volver a llenarla. La instalación debe estar realizada con tecnología moderna. (Colocación del vaso de expansión y avance de seguridad). 4.3 Montaje Montaje recién después de terminar todos los trabajos de soldadura. Evitar goteos de agua sobre el motor de la bomba, especialmente sobre la electrónica. Coloque la carcasa de bomba en la instalación, libre de tensiones mecánicas. Rauhwerte Ra 12.5 6.3 3.2 1.6 0.8 0.4 Rauheitsklassen N10 Allgemeintoleranzen ISO 2768-mK N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 46 | espagñol über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 4.4 Posiciones de montaje admisibles El eje del rotor debe estar siempre horizontal, nunca vertical. 961583_00 Se provee con enchufe a la izquierda 1 Stück II I Pos Gegenstand Änd.Index Datum Visum Material Ersatz für: 961585_00 ModulA GREEN Modell/Art.Nr Bemerkung Ersetzt durch: Massstab gezeichnet 15.02.2013 ts 1:4 Motor waagrecht für BA geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021617 Zeichnungsnummer Biral AG CH-3110 Münsingen Änd.Index 00 961583 961586_00 II I Änd.Index Datum Visum Ersetzt durch: 1:4.4 Montageposition Biral AG CH-3110 Münsingen II I Änd.Index Datum Ersatz für: Massstab gezeichnet 15.02.2013 ts ModulA GREEN Visum geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021620 Zeichnungsnummer Änd.Index 00 961585 Ersetzt durch: Ersatz für: Massstab gezeichnet 15.02.2013 ts ModulA GREEN Montageposition Stecker 3-6-9-12 Biral AG CH-3110 Münsingen 1:4.4 geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021621 Zeichnungsnummer 961586 Änd.Index 00 El enchufe no debe mirar nunca hacia abajo, pues podría ingresar agua. Antes de instalar la bomba, el motor puede girarse de a 90°. Para ello, deben aflojarse los 4 tornillos de la carcasa, girando el cabezal motriz según las posiciones admisibles para el motor. No mueva o dañe la junta entre motor y carcasa de bomba. Tras colocar los tornillos, apriételos en la cruz. espagñol | 47 4.5 Montaje de la bomba en la instalación ➀ C errar válvulas de cierre y asegurar que la instalación esté despresurizada al montar la bomba. ➁ Montar la bomba con juntas en la tubería 1 2 Advertencia ¡Riesgo de lesiones por escape de vapor! 1 961589_00 4.5.1 Conexión bridada Las bridas de la bomba están perforadas con agujeros de sujeción PN6/PN10/PN16. Para lograr una atronilladura segura de las bridas, es necesario montar las arandelas «B» sobre el costado de la bomba. II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 15.02.2013 ts ModulA GREEN Pumpe mit Absperrschieber Bild1 1:5 DN für BA geprüft Freigabe 18.02.2013 ts 18.02.2013 ts AZeichnungsnummer PDM_Nr Biral AG CH-3110 Münsingen TD-0021624 Änd.Index 00 961589 B No se permiten elementos de bloqueo (p.ej. arandelas Grover). Para PN 10/16 deben utilizarse juntas y tornillos especiales. 961590_00 Advertencia Para la presión nominal correspondiente PN utilice los tornillos correspondientes. Änd.Index II I Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 15.02.2013 ts ModulA GREEN Pumpe mit Absperrschieber Bild2 1:5 A B M 960573_00 960573_00 für BA M Biral AG CH-3110 Münsingen Ø Ø PN 6 PN 10 / 16 PN 6 PN 10 / 16 M 12 M 16 Ø 14 Ø 18 M 16 M 16 – – DN 32 DN 40 DN 50 DN 65 DN 80 DN 100 Momento de apriete de tornillos recomendado: –– para M 12 <40 Nm –– para M 16 <95 NmDatum Visum Änd.Index Ersetzt durch: Ersatz für: II I No está permitido el montaje de brida combinada con brida Massstab gezeichnet 10.12.2014 nma combinada. Flansch PN6/10/16 1:2 geprüft 10.12.2014 nma Änd.Index Datum Visum II für BA Freigabe Ersetzt durch: I PDM_Nr Biral AG CH-3110 Münsingen 10.12.2014 nma Ersatz für: TD-0028815 Zeichnungsnummer Flansch PN6/10/16 960573 für BA Biral AG CH-3110 Münsingen Änd.Indexgezeichnet 10.12.2014 nma Massstab 00 1:2 geprüft 10.12.2014 nma Freigabe 10.12.2014 nma PDM_Nr TD-0028815 Zeichnungsnummer 960573 Änd.Index 00 geprüft 18.02.2013 ts Freigabe 18.02.2013 ts PDM_Nr TD-0021625 Zeichnungsnummer 961590 Änd.Index 00 48 | espagñol 4.6 Instalación del variador de frecuencia 100 238 230.5 961563_00 max 2m Entre el variador de frecuencia y el motor sólo está permitido utilizar el cable de conexión original (2 m). II I Änd.Index ModulA Datum Massbild Visum 40 Ersetzt durch: Montar el soporte de pared. Ersatz für: Massstab gezeichnet 25.01.2013 ts 8 Bausatz für abgesetzte Montage B 8x38 geprüft 15.02.2013 ts Freigabe 15.02.2013 ts PDM_Nr TD-0021441 C 5x40 Zeichnungsnummer 961563 Änd.Index 00 91 Biral AG CH-3110 Münsingen 1:4.4 961591_00 Advertencia El soporte debe montarse siempre en posición vertical. Frequenzumrichter einhängen. II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 18.02.2013 ts ModulA GREEN 1:2.5 Bausatzt kpl Wandmontage geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021630 Zeichnungsnummer Biral AG CH-3110 Münsingen 961593_00 II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 18.02.2013 ts ModulA GREEN 1:2.5 Bausatzt kpl Wandmontage Biral AG CH-3110 Münsingen geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021632 Zeichnungsnummer 961593 Änd.Index 00 961591 Änd.Index 00 espagñol | 49 4.7 Montaje del enchufe − Inserte cuidadosamente el enchufe del lado del motor ➀ − Atornille los tornillos M6×40 ➁ ➀ ➁ 961594_00 –E nchufe el cable del sensor ➂ − Coloque el pasacable ➃ ➂ II I Änd.Index Datum Visum ➃ Ersetzt durch: Ersatz für: Massstab gezeichnet 18.02.2013 ts ModulA GREEN Stecker für Motor 961595_00 − Fije la cubierta ➄ con 3 tornillos Biral AG CH-3110 Münsingen 1:3.5 geprüft 02.04.2013 ts Freigabe 02.04.2013 ts PDM_Nr TD-0021638 Zeichnungsnummer 961594 ➄ Änd.Index 00 50 | espagñol 5. Conexión eléctrica Es imprescindible que la conexión eléctrica cumpla las prescripciones locales. Asegúrese de que la tensión y la frecuencia indicads en la placa de características coincidan con la red de distribución existente. Advertencia Antes de realizar cualquier trabajo eléctrico de conexión es necesario interrumpir la alimentación eléctrica. La bomba debe conectarse a un interruptor de red externo provisto de un seccionador eléctrico para todos los polos, de 3 mm de apertura mínima de contactos. La protección contra contacto indirecto puede lograrse con puesta a tierra o nivelación de potencial. En caso de conectarse la bomba a una instalación provista de disyuntor diferencial como protección adicional, éste debe dispararse ante corrientes de fuga a tierra con componente continua pulsante. El disyuntor debe estar identificado con el siguiente símbolo:: Externer Schalter FI L N L N Sicherung (min.10A, träge) La bomba no requiere guardamotor externo. El motor posee una protección por sobretemperatura incorporada, la cual protege contra sobrecargas de incremento lento y contra bloqueo, conforme a IEC 34-11: TP 211. 5.1 Tensión de alimentación 1×230V ±10%, 50 / 60 Hz, PE 961807_00 Las tolerancias de tensión se establecen para compensar fluctuaciones de la tensión de red. Ellas no implican que deban hacerse funcionar las bombas con tensiones diferentes a las indicadas en la placa de características. En conexión directa a la red, no debe encenderse y apagarse la bomba con una frecuencia mayor a cuatro veces por hora. Si se conecta la bomba a la red en forma directa, arranca con un retardo de 5 segundos. espagñol | 51 5.2 Conexión de la tensión de alimentación La bomba debe llevar un fusible (mín. 10, lento) y debe conectarse a un interruptor de alimentación externo. Todos los cables utilizados deben tolerar los 85 °C. Los mismos no deben tomar contacto con la cañería, las bombas y con carcasas de motores. El cableado deberá realizarse conforme a las normas EN 60204-1 y EN 50174-2: 2000. La conexión eléctrica debe realizarse como se indica en la placa de datos. ModulA… Corriente nominal [A] ModulA 32F-12 220, ModulA-D 32F-12 220 0.17 – 1.50 Potencia P1 [W] 16 – 328 ModulA 40-8 220, ModulA-D 40-8 220 0.20 – 1.21 20 – 268 ModulA 40-10 220, ModulA-D 40-10 220 0.19 – 1.54 18 – 341 ModulA 40-12 250, ModulA-D 40-12 250 0.18 – 1.91 17 – 421 ModulA 40-18 250, ModulA-D 40-18 250 0.18 – 2.63 16 – 594 ModulA 50-6 240, ModulA-D 50-6 240 0.21 – 1.09 21 – 236 ModulA 50-6 270 0.21 – 1.09 21 – 236 ModulA 50-8 240, ModulA-D 50-8 240 0.21 – 1.42 22 – 315 ModulA 50-12 270, ModulA-D 50-12 270 0.21 – 2.32 20 – 516 ModulA 50-18 270, ModulA-D 50-18 270 0.21 – 3.34 22 – 742 ModulA 65-8 270 0.24 – 2.10 22 – 464 ModulA 65-8 340, ModulA-D 65-8 340 0.24 – 2.10 22 – 464 ModulA 65-12 340, ModulA-D 65-12 340 0.22 – 3.32 21 – 736 ModulA 65-15 340, ModulA-D 65-15 340 0.28 – 5.68 30 – 1254 29 – 704 ModulA 80-8 360, ModulA-D 80-8 360 0.29 – 3.08 ModulA 80-12 360, ModulA-D 80-12 360 0.32 – 5.56 32 – 1282 ModulA 100-12 450, ModulA-D 100-12 450 0.32 – 6.78 35 – 1563 Interruptor 2 externo FI N N L L Fusible 1 (mín. 10 A, lento) 961613_02 Ejemplo de una típica conexión a la red, 1×230 V ±10%, 50/60 Hz Legende: 1 Sicherung (min.10A, träge) 2 Externer Schalter 52 | espagñol 5.3 Diagrama de conexiones Inscripciones de los bornes Conexión de red: 1x230V +/- 10%, 50/60Hz Bornes: L, N, PE Alimentación eléctrica +24- 24 V DC out 11, 10Apagado externo o Encendido externo (conmutable) 52, 54, 51Aviso de avería o aviso de funcionamiento Interruptor: 1 Aviso de fallo o aviso de funcionamiento (conmutable) 2 OFF externo u ON externo (conmutable) 3 Power Limit (límite de potencia, activable) Switch DC out 24V max. 20mA 11 10 52 54 51 max. 250V AC 2A min. 5V DC 20mA II I Änd.Index Datum Visum L N AC in ~1x230V ±10% 50/60 Hz Ersetzt durch: 961566_00 +2 4- Ersatz für: Massstab gezeichnet 08.02.2013 ts ModulA 750W Anschlussschema mit FU für BA Biral AG CH-3110 Münsingen 1:2 geprüft 15.02.2013 ts Freigabe 15.02.2013 ts PDM_Nr TD-0021543 Zeichnungsnummer 961566 Änd.Index 00 5.4 Switch ajustes Switch 2 Aviso de fallo o funcionamiento 5 24V 5 24V24V Apagado Por defecto Limit DC20mA outPower DC out 20mA 10 max. max. max. 20mA DC out 3.3 24V 24V 24V max. 20mA out max. 20mA externo oDC24V Encendido max. 20mA max. 20mA Switch+2 +2 11L 10L N 52 54 externo 524-51 54 51 N 51 4- 411 11 10 1052+2 54 88 8 6 88 50/60 min. Hz 5V DC 20mA 20mA Betrieb ON 52 54 51 52 54 51 52 52154 54 51 51 1 Interruptor 1 II I ON II I ModulA Änd.Index II I ON 1 II I Änd.Index Änd.Index II I Änd.Index 5252 5454 5151 2 Datum Datum Datum Aviso de51 ON 5252 5454 51 Visum 52 54 52 54 52 54 Visum Visum Visum Visum Ersetzt Ersatz für:durch: Ersetzt durch: Ersatz für: Hélice ONdetenida 961827 CH-3110 Biral AG Münsingen Aviso deCH-3110 Biral AG Biral AG Münsingen 961827 CH-3110 Münsingen 00 CH-3110 Münsingen 961827 CH-3110 Biral AG Münsingen 5252 5454 51 52 5400 51 52 54 51 51 II I funcionamiento 961827 Münsingen ON2 CH-3110 ON 2 ModulA inactivo 1:1 Relaisaugänge1:1 ON Änd.Index ModulA Datum Visum Zeichnungsnummer Visum Ersetzt Ersatz für: durch: Änd.Index Datum Ersetzt durch: Änd.Index Relaisaugänge Ersatz für: geprüft 51,52,54 Freigabe Freigabe PDM_Nr PDM_Nr TD-0028419 Änd.IndexZeichnungsnummer Biral AG Biral AG 3 3 CH-3110 961827Münsingen 00961827 CH-3110 Münsingen Zeichnungsnummer 5252 5454 5151 52 54 51 Änd.Index 00 52 54 51 961865_01 ON 01 II Datum I Änd.Index 16.01.2015 Visum ON ts Datum Änd.Index Ersetzt Visum durch: II I Ersetzt durch: Datum Visum Ersatz für: Ersetzt durch: Ersatz für: Freigabe Freigabe 51,52,54 PDM_NrTD-0028816 TD-0028419 PDM_Nr Biral AG Zeichnungsnummer Zeichnungsnummer Biral AG Biral AG 961827Münsingen CH-3110 Münsingen CH-3110 961865 CH-3110 Münsingen Änd.Index Datum Visum 01 16.01.2015 ts Ersetzt durch: Ersatz für: Massstab gezeichnet 10.12.2014 nma ModulA 3:1 Switch 3 geprüft Freigabe PDM_Nr Biral AG CH-3110 Münsingen 1:1 3:11:1geprüftgeprüft Relaisaugänge Switch 3Relaisaugänge 3 51,52,54 3 II I Ersatz für: Massstab gezeichnet 13.11.2014 ts Massstab gezeichnet 10.12.2014 Massstab gezeichnet 13.11.2014 nma ts ModulA ModulA TD-0028816 Zeichnungsnummer 961865 Änd.Index 01 geprüft Freigabe PDM_Nr TD-0028419 Zeichnungsnummer Änd.Index Änd.Index 961827 00 01 Änd.Index 00 6 6 8 6 8 8 6 6 6 8 +2 6 ts 1 2 3 Änd.Index 961828 activo TD-0028419 961808 TD-0028423 Zeichnungsnummer Hélice detenida Aviso 00 de funcionamiento inactivo ts Massstab gezeichnet 13.11.2014 geprüft Massstab gezeichnet 13.11.2014 ON ModulA geprüft 52 54 51 52 54 51 Ersatz für:funcionamiento 1 2 3 DC 2 max Ersatz für: 17.10.2014 ts Freigabe 17.10.2014 ts Ersatz für: PDM_Nr TD-0026660 Massstab gezeichnet 13.11.2014Zeichnungsnummer ts Änd.Index PDM_Nr Aviso de fallo activo 5 Massstab gezeichnet 16.10.2014 ts Biral AG geprüft CH-31101:1 Münsingen Freigabe Biral AG CH-3110 Münsingen 51 51 51 3.3 6 6 Ersetzt durch: Ersetzt durch: Ersetzt Ersatz für: Ersetzt durch: für:durch: Massstab Ersatz gezeichnet 13.11.2014 ts Massstab gezeichnet 13.11.2014 ts IIIIVisum II ModulA Ersetzt durch: Ersatz für: geprüft Massstab 1:1 gezeichnet 1:1 geprüft gezeichnet 13.11.2014 13.11.2014 ts ts Massstab ModulA gezeichnet 13.11.2014 ts Massstab ModulA Relaisaugänge ModulA Relaisaugänge Freigabe geprüft MassstabFreigabe gezeichnet 13.11.2014 ts1:1 geprüft geprüft ModulA 51,52,54 51,52,54 Relaisaugänge1:1 Relaisaugänge PDM_Nr TD-0028419 PDM_Nr TD-0028419 Relaisaugänge Freigabe geprüft Freigabe Freigabe 1:1 51,52,54 Änd.Index 961865_01 Relaisaugänge Zeichnungsnummer Änd.IndexZeichnungsnummer 51,52,54 51,52,54 PDM_Nr TD-0028419 Freigabe TD-0028419 PDM_Nr TD-0028419 Biral AGPDM_Nr Biral AG Zeichnungsnummer Änd.Index 51,52,54 Zeichnungsnummer Änd.Index Zeichnungsnummer Änd.Index PDM_Nr TD-0028419 00 961827 00 51,52,54 II I Visum Hélice girando Aviso de 5252 5454 5151 funcionamiento activo Änd.Index Datum Ersetzt durch: Änd.Index Datum Änd.Index Datum Datum Hélice rojo Hélice girando 52 54 51 Datum Visum 52 54 51 II I Änd.Index ModulA BG2 Aviso de fallo Anschlussschema mit FU für BA inactivo Klemme 11, 10 ON 5252 54 51fallo 54 51 Aviso de 52252 5454 51 52 5451 51 activo52 AC in ~1x230V ±10% 50/60 Hz Hélice verde II I ModulA Hélice ONrojo ON 1 ON inactivo 00 961865 CH-3110 Münsingen 52 54 51 52 54 51 52 54 51 5 961827_00 Änd.Index 00 00 6 Hélice verde 10.12.2014 nma 3:154 geprüft 52 51 52 52 5454 5151 10.12.201452 nma54 51 52 54 Freigabe 51 52 54 51 52 54 51 52 52 54 51 52 54 51 52Zeichnungsnummer 54PDM_Nr 51 TD-0028816 52 54fallo 51 Aviso de Änd.Index 10 DC 2 max 6 Interruptor 1 Biral AG OFF 5 961827_00 6 11 10 +2 +2 8 Ersatz für: Massstab gezeichnet 10.12.2014 nma 5 24V 3.3 max. 20mA La bomba posee un relé de aviso con un contacto 52 544-51 N 54 51 inver961828_00 +2 11L10 52 L N sor con separación galvánica, max. 250V AC max. 250V AC AC in AC in 2A destinado a generar un~1x230V aviso ~1x230V ±10%2A ±10% min. 5V DC 50/60 min. Hz 5V DC de20mA fallo hacia el 20mA exterior.50/60 Hz Este relé de aviso puede conmutarse para aviso de 1:2 funcionamiento mediante el interruptor 1. 8 L N 8 +2 4- Estado 52 54 51 52 54 8 5 10 11 10 961827_00 6 24V max. 20mA 6 6 Betrieb EIN 5 8 Conexión 52 54 51 5252 5454 5151 5254 5451 51 52 54 51 Estado 5252 Betrieb AUS DC 3.3 2 DC max 2 max 6 ON 5 6 6 6 11 10 6 Ersetzt durch: 961827_00 961827_00 6 11 10 961808_00 ModulA Switch 3 Visum N 8 Extern EIN Datum Aviso de fallo Änd.Index 50/60 Hz L +2 4Switch 2 5.4.1 Interruptor 1, aviso de fallo o aviso de funcionamiento (conmutable) DC out DC out 52 54 54 51 51 52 N NN max. 250V AC AUS AC inmax. 250V AC AC in 5 2A ~1x230V ±10%2A DC out ~1x230V ±10% min. 5V DC 50/60 min. Hz 5V DC 24VHz 50/60 20mA max. 20mA 10 20mA Bold lettering = as delivered Conexión 52 54 51 L LL 11 10 52 54 51 11L10 52 N 54 51 11 10 +2 4-NO (APAG) Betrieb EIN OFF 5 8 externo 20mA2A min. 5V DC 20mA 8 +2 4- 11 10 Apagado 5 6 66 6 66 6 8 8 6 8 6 6 6 6 6 8 6 6 10 5 3.3 3.3 3.3 961827_00 961827_00 961827_00 6 5 5 5 6 Aviso de fallo, bornes 52, 54, 51 5 8 APAG (OFF) 961865_00 Switch 2 5 10 10 11 10 52 250V 54 Sí (ENC) AC max.max. 250V AC 51 AC AC inmax. AC in AC in250V 2A 2A 2A5 ~1x230V ±10% 10% ±250V ±max. AC ~1x230V ~1x230V 10% max. 5V 250V AC out ACininHz Klemmen AC in max. AC min. 250V 5V DC DC 5min. DC min. 5V DC AC 5 50/60 50/60 2A 50/60 Hz 2A 5Hz 24V 3.3 5 ~1x230V ±10% ~1x230V 10% 2A 20mA ± 20mA gebrückt 20mA ~1x230V ±10% 10 max. 3.3 DC min. 5V min. 5V DC250V AC max. 20mA 50/60 Hz 6 1 2 3 5 5 5 10 3.3 +2 4-51 11 11L10 10 52 52 54 51 51 52+2 544N 54 11 10 +2 4Encendido DC out 24V externo Ausganslage max. 20mA 6 ON +2 4- Aviso de funcionamiento, bornes 52, 54, 51 Extern AUS ENC (ON) 3.3 961827_00 6 8 8 5 10 961827_00 961827_00 6 10 5 DC out 5 8 66 66 6 6 5 5 Switch 3 5 DC out DC out 6 6 6 Switch 1 8 Función Aviso de funcionamiento I espagñol | 53 +2 54 | espagñol 5.4.2 Interruptor 2, OFF externo u ON externo (conmutable) Klemmen DC out Ausganslage 24V max. 20mA Conexión Estado Interruptor Switch 2 2 4+2 11 11 10 10 52 54 51 OFF FuncionaBetrieb ON ON miento EIN ON 11 10max. 250V AC 2 ON 1 2 3 ON 961865_01 3 6 11 10 2A min. Betrieb 5V DC AUS 20mA OFF ON ON2 FuncionaBetrieb miento ON AUS Betrieb EIN 961828_00 3 5.4.3 Interruptor 3, Power Limit (límite de potencia, activable) • ON Switch El Powerlimit (límite 2 11 10 del caudl volumétrico 11 10 V) 961865_01 961828_00 puede activarse en la bomba. +2 4- Visum 01 16.01.2015 ts ModulA 33 Switch ON 3 ON Datum Ersetzt durch: Massstab gezeichnet 10.12.2014 nma 3:1 3 geprüft Freigabe ts .2015 Änd.Index 01 961865 L N Ersetzt durch: TD-0028816 Zeichnungsnummer Biral AG CH-3110 Münsingen Visum Betrieb EIN Ersatz für: PDM_Nr um Betrieb AUS 961828_00 Ersatz für: Massstab gezeichnet 10.12.2014 nma 3:1 ts geprüft Freigabe TD-0028816 Ersatz für: PDM_Nr Zeichnungsnummer Änd.Index 961808_00 Visum Ersetzt durch: AC in Biral AG Massstab gezeichnet 10.12.2014 nma 961865 CH-3110 Münsingen ~1x230V ±10% geprüft Änd.Index Datum 3:1 II I Freigabe PDM_Nr ModulA 961865 Ersetzt durch: Massstab gezeichnet 13.11.2014 01 Klemme 10durch: L NVisum 11,Ersetzt Datum Ersatz für: 1:1 Freigabe Biral AG ModulA PDM_Nr TD-0026660 Ersetzt durch: Ersatz für: Zeichnungsnummer Änd.Index Massstab gezeichnet 13.11.2014 CH-3110 Münsingen Visum 11, 10 Klemme Ersetzt durch: Datum ModulA BG2 Anschlussschema mit FU für BA TD-0028423 Massstab gezeichnet 16.10.2014 ts Power Limit ENC Zeichnungsnummer Biral AG geprüft 17.10.2014 ts 1:2 Rango de ajuste 961828 CH-3110 Münsingen Freigabe 17.10.2014 ts Visum 961808 1:1 Ersatz für: 00 Änd.Index 00 ts geprüft Freigabe PDM_Nr TD-0028423 Massstab gezeichnet 16.10.2014 ts Zeichnungsnummer Änd.Index Biral AG 1:2 geprüft 17.10.2014 ts Freigabe 961828 17.10.2014 ts CH-3110 Münsingen PDM_Nr Biral AG CH-3110 Münsingen ts geprüft PDM_Nr AC in Anschlussschema ±10% Änd.Index Datum mit FU für BA~1x230V 50/60 Hz II I 961808_00 Ersatz für: Änd.Index ModulA BG2 Änd.Index 01 Visum TD-0028816 Zeichnungsnummer Biral AG CH-3110 Münsingen Änd.Index 50/60 Hz TD-0026660 Zeichnungsnummer 961808 Änd.Index 00 6 8 11 10 6 3 ON Extern EIN ON1 2 3 nd.Index 10 52 8 Switch 2 961865_01 ON 11 10 FuncionaBetrieb miento EIN OFF ON 1 2 3 ON 1 5 8 11 11 10 10 52 54 51 ON 2 2 gebrückt min. 5V DC 20mA 6 1 ON ONInterruptor SwitchON2 ON +2 2 4- max. 250V AC Ausganslage 2A 6 ON externo Extern Extern EIN AUS ON 2 6 DC out 24V 2OFF max. 20mA 1 Switch 1 6 ON 11 10 FuncionaBetrieb miento OFF KlemmenAUS Entrada digital La entrada digital puede implementarse para la conmutación remota ON/ OFF de la bomba. Mediante el interruptor 2 es posible 5 conmutar de OFF externo DC out a ON externo. 24V max. 20mA 10 Nota: Si ho hay ningún interruptor ON/OFF externo +2 fun4- 11 conectado, la bomba ciona cuando el interruptor 2 está en posición OFF y 5 DC out no se han puenteado los 24V 10 max. es 20mA bornes 11 y 10. Esta la configuración de fábrica. 5 6 OFF externo Extern AUS ON gebrückt Conexión Estado 8 Switch 00 El caudal volumétrico máximo preestablecido se encuentra al final de la curva de regulación 3 (presión proporcional). Mediante el Biral Remote es posible ajustar el límite de caudal volumétrico de 25 a 90 %. 52 espagñol | 55 6. Puesta en marcha 6.1 Generalidades Antes de poner en servicio la instalación es necesario llenarla con el medio a transportar y purgarle el aire. Además, la presión mínima de alimentación necesaria debe estar presente a la entrada de la bomba. La instalación no puede purgarse de aire con la bomba. La bomba elimina el aire por sí misma. 6.2 Control de funcionamiento Pumpe steht. Störung (Problemfälle) Tras conectar la alimentación eléctrica, la bomba debe arrancar automáticamente: laPumpe hélice Biral gira con luz verde. Pumpe steht. Störung (Problemfälle) läuft normal Drehun Muster Farbe Drehung drehend Muster normal Farbe grün La bomba funciona según los ajustes básicos (ver sección 7.9) Pumpe läuft. Störung (Problemfälle) Pumpe Extern OFF Drehung stehend Muster blitzend Farbe grün Drehun Muster Farbe Pumpe START/STOP von Taste oder App Drehung stehend Muster normal Farbe grün ModulA-...D mit BIM A2 Siganlmodul Doppelpumpe (Pumpe aktiv) Drehung drehend Muster normal Farbe grün Doppelpumpe (Pumpe passiv) Drehung stehend Muster blitzend Farbe grün Betriebskontrolle Änd.I Mod Bir 961568_00 56 | espagñol 7. Ajustes Advertencia ¡Riesgo de sufrir quemaduras! Con altas temperaturas, la bomba puede calentarse a tal punto, que sólo es posible tocar las teclas de mando. 3.2 1.6 0.8 N8 N7 N6 3 3.2 1.6 0.8 9 N8 N7 N6 7.1 Panel de mando A1Tecla de mando para configurar el tipo de regulación, ver sección 7.2 A2Teclas de mando para la configuración (altura de impulsión) con ícono luminoso (LED) indicando altura 0.4 Allgemeintoleranzen ISO 2768-mK N5 de impulsión y caudal transportado ver sección 7.3 über 6 bis 30 über 30 bis 120 über 120 bis 400 über 400 bis 1000 0.5 bis 6 LED 1 Nota de regulación elegida (etapa) ± 0.2 de la característica ± 0.3 ± 0.5 ± 0.8 ± 0.1 • 0.4 LED 2 Nota del caudal actua V (25…100%) Allgemeintoleranzen ISO 2768-mK N5 LED0.5 3 Hüber ÉLICE Biral indica el estado de la bomba ver sección 7.9 6 bis 30 über 30 bis 120 über 120 bis 400 über 400 bis 1000 bis 6 ± 0.2 ± 0.3 ± 0.5 0.8 Rauhwerte Ra 12.5 B ± 0.1 Receptáculo de conector para ±adaptador remoto Rauheitsklassen N10 6.3 3.2 1.6 0.8 0.4 Allgemeintoleranzen ISO 2768-mK N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 400 ± 0.5 7.2 TypesAllgemeintoleranzen of control ISO 2768-mK 3 3.2 1.6 0.8 0.4 9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 Ciclo del tipo de regulación Modo regulado: Presión constante (cp) Importante en las siguientes instalaciones: – sistemas de doble tubo con válvulas térmicas y • Altura de impulsión >2m 961204_00 • Circulación natural (calefacción antigua por gravedad) – con muy poca pérdida de carga – bombas de circuito primario en instalaciones con baja 961204_00 pérdida de carga – calefacción de losa radiante con válvulas de termostato – calefacciones de haces unitubulares 961204_00 Modo sin regulación. Velocidad constante (cs) El punto de trabajo puede ajustarse de manera óptima regulando la velocidad (teclas A2). 961204_00 Útil para instalaciones de caudal constante: Aire acondicio Gegenstand Stück Änd.Index Datum nado, bombas térmicas, alimentación de calderas, etc. Pos Visum 2enstand ab 2009 Material Modell/Art.Nr Bemerkung Ersetzt durch: Pos Visum gsart Zyklus Ersetzt durch: Material 2 ab 2009 Biral AG gsartCH-3110 Zyklus Münsingen Pos Biral AG Material Massstab gezeichnet 07.01.2009 ts 1:1 Modell/Art.Nr Bemerkung geprüft 20.03.2009 ts Ersatz für: Freigabe 20.03.2009 ts PDM_Nr TD-0011003 Massstab gezeichnet 07.01.2009 ts Zeichnungsnummer Änd.Index geprüft 20.03.2009 ts 1:1 961204 Freigabe PDM_Nr II I Pos Visum Material 00 20.03.2009 ts TD-0011003 Modell/Art.Nr Zeichnungsnummer Bemerkung Änd.Index Modell/Art.Nr Bem Ersetzt durch: A402 - A652 ab 2009 Ersatz für: Datum enstand über 30 bis 120 ± 0.3 de mando Modo regulado: Presión proporcional (pp) Importante en las siguientes instalaciones: – sistemas de doble tubo con válvulas térmicas y • tramos largos de cañería • válvulas con rango de trabajo amplio • mucha pérdida de carga – bombas de circuito primario con elevada pérdida de carga nstand Datum über 6 bis 30 ± 0.2 Tecla Regelungsart Zyklus BA Biral AG CH-3110 Münsingen Ersatz für: Massstab gezeichnet 07.01.2 1:1 geprüft 20.03.2 Freigabe 20.03.2 PDM_Nr TD-001 Zeichnungsnummer 961204 espagñol | 57 7.3 Altura de impulsión (A2) El valor deseado de la bomba puede ajustarse presionando la tecla o . Ejemplo: LED 3 brilla (verde) Característica 3 LED 3 y 4 brillan (verde): Característica entre 3 y 4 En caso de que los radiadores no alcancen la temperatura suficiente, configurar la característica siguiente. • 7.4 Nota del caudal actual (LED V ) • V = 25, 50, 75, 100% 7.5 Vista general de altura de impulsión, caudal de impulsión máximos ModulA… • Hmax [m] Vmax [m3 / h] ModulA 32F-12 220, ModulA-D 32F-12 220 12 17 ModulA 40-8 220, ModulA-D 40-8 220 8 18 ModulA 40-10 220, ModulA-D 40-10 220 10 21 ModulA 40-12 250, ModulA-D 40-12 250 12 24 ModulA 40-18 250, ModulA-D 40-18 250 18 28 ModulA 50-6 240, ModulA-D 50-6 240 6 25 ModulA 50-6 270 6 25 ModulA 50-8 240, ModulA-D 50-8 240 8 27 ModulA 50-12 270, ModulA-D 50-12 270 12 33 ModulA 50-18 270, ModulA-D 50-18 270 18 37 ModulA 65-8 270 8 36 ModulA 65-8 340, ModulA-D 65-8 340 8 36 ModulA 65-12 340, ModulA-D 65-12 340 12 33 ModulA 65-15 340, ModulA-D 65-15 340 15 58 ModulA 80-8 360, ModulA-D 80-8 360 8 54 ModulA 80-12 360, ModulA-D 80-12 360 12 57 ModulA 100-12 450, ModulA-D 100-12 450 12 74 58 | espagñol 7.6 Activar/desactivar detección de marcha en seco Pulsando simultáneamente la tecla (por lo menos 3 seg.) y las teclas de función se activan o desactivan en el panel de mando. 7.7 Arranque/Parada de la bomba Cambiar el modo de funcionamiento a START o STOP, presionando tecla (3 seg.). 7.8 Activate / deactivate dry running detection Presionando simultáneamente las teclas , y (por 10 s) se activa o desactiva la función de detección de marcha en seco. 1. Quitar todos los BIM presentes 2. Encender bomba 3. Asegurarse de que la bomba no se encuentre en modo Stop. 4. Asegurarse de que la bomba no tenga caudal actualmente 5. Desactivar bloqueo de teclas 6.Presionar las tres teclas por 10 s (10 s corresponden a unos 8 a 9 giros de la hélice) • Una breve interrupción al presionar puede producir que el bloqueo de teclas se active o que la bomba conmute a modo Stop. 7.Cuando la hélice gira con dos segmentos está desactivada la detección de marcha en seco; cuando la hélice gira con un segmento la detección de marcha en seco está activada. 8. Se pueden volver a conectar módulos o señales externas. . Si la bomba está funcionando realmente en seco por haberse desactivado la detección de marcha en seco, no se registrará error y puede funcionar defectuosamente. La detección de marcha en seco sólo puede desactivarse si la bomba funciona en operación libre de fallos y no se ha enchufado ningún BIM (Biral Interface Module). espagñol | 59 Pumpe steht. Störung (Problemfälle) Drehung drehend Muster normal Farbe grün 7.9 La hélice Biral Zusatzmodule muestra el estado de la bomba: ng stehend blinkend rot Pumpe läuft normal Steuer,Extern PWM, OFF Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Pumpe Drehung drehend Muster normal La bomba funciona Color Drehung stehend Drehung drehend Farbe Muster blitzend Mustergrün blitzend (modo regulación) Pumpe läuft läuften normal Farbe Pumpe normal Farbe grün grün ng drehend normal rot Drehung drehend Drehung drehend verde Muster Muster normal normal Farbe Farbe grün grün Drehung stehend Muster blitzend Drehung stehend Drehung stehend verde Farbe Muster normal Mustergrün blitzend Farbe Farbe grün grün Pumpe Extern OFF Pumpe von Taste oder App Steuer, START/STOP PWM, Hoval. Pumpe gestoppt Pumpe Extern Extern OFF OFF Pumpe Pumpe START/STOP von Taste oder App Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) Pumpe Pumpe START/STOP START/STOP von von Taste Taste oder oder App App ModulA-...D mit BIM A2 Siganlmodul Pumpe steht. Störung (Problemfälle) Doppelpumpe (Pumpe aktiv) Steuermodul BIM B2: Doppelpumpe Bomba Pumpe steht.averiada Störung (Problemfälle) (Pumpe passiv) Drehung 12.5 6.3 drehend 3.2 1.6 0.8 0.4 Farbe grün Allgemeintoleranzen ISO 2768-mK ModulA-...D mit BIM A2 Siganlmodul 0.5 bis 6 ± 0.1 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 Doppelpumpe (Pumpe aktiv) Doppelpumpe (Pumpe passiv) ... ModulA-...D mit BIM BIM A2 Siganlmodul Siganlmodul ModulA-...D Pumpe läuft.mit StörungA2 (Problemfälle) Drehung stehend Muster blitzend Farbe grün Doppelpumpe (Pumpe passiv) ... Drehung stehend Muster normal Drehung drehend verde Farbe Mustergrün blitzend Farbe grün Drehung Drehung stehend stehend Muster Muster normal normal Farbe Farbe grün grün Drehung Drehung drehend stehend Muster normal Drehung stehend Muster blitzend rojogrün Farbe Muster blinkend Farbe grün Farbe rot Steuer, PWM, Hoval. Pumpe Pumpe läuft. Störung (Problemfälle) Pumpe Pumpe steht. steht. Störung Störung (Problemfälle) (Problemfälle) Muestra Giro Datum Estado Pumpe steht. steht. Störung Störung (Problemfälle) (Problemfälle) Pumpe gira Drehung stehend Drehung stehend Bomba funciona normal Muster Muster blinkend blinkend Pumpe läuft. Störung (Problemfälle) Farbe ModulA-D ... (bomba Farbe rot rot activa) flashing still Drehung drehend Bomba, parada externa Muster normal Muster normal Farbe rot rot Farbe ModulA-D ... (bomba pasiva) inter mitente gira Bomba bajo control externo Steuer, PWM, Hoval. Pumpe Steuermodul BIM B2: Doppe Drehung drehend Muster normal normal still Bomba STOP Farbe de tecla o aplicación rot ver sección 7.7 (bomba detenida) Steuer, Steuer, PWM, PWM, Hoval. Hoval. Pumpe Pumpe Pumpe läuft. läuft. Störung Störung (Problemfälle) (Problemfälle) Pumpe Drehung drehend Steuermodul BIM B2: Doppe ... inter mitente still drehend Alarma(Aviso Drehung de funcionamitente Steuermodul BIM BIM B2: B2: Doppe Doppe Muster blitzend Steuermodul APAG)Farbe grün (Aviso de avería: ENC) ... ... normalSteuer,gira Adver- PWM, Hoval. Pumpe gestoppt tencia (Aviso de funcion.: ENC) (Aviso Drehung de avería: stehend ENC) ... ... Muster blitzend Farbe grün ... Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) Drehung drehend Muster blitzend ModulA ts Änd.Index Datum Änd.Index Impeller Datum Biral ... Material 02 - A652 ab 2009 egelungsart Zyklus Biral AG CH-3110 Münsingen Visum Visum Visum Biral Biral AG AG CH-3110 CH-3110 Münsingen Münsingen ... Ersatz für: geprüft 20.03.2009 ts Freigabe 20.03.2009 ts PDM_Nr TD-0011003 Zeichnungsnummer 961204 Änd.Index 00 Änd.Index Datum Ersetzt durch: Ersetzt durch: Biral AG Biral Impeller Impeller CH-3110 Biral Münsingen Massstab gezeichnet 07.01.2009 ts 1:1 Ersetzt durch: Biral AG CH-3110 Münsingen Modell/Art.Nr Bemerkung Ersetzt durch: Ersetzt durch: Drehung ... Muster ... ModulA ModulA Farbe ... Drehung ... Muster ... Farbe ... Pos Visum ModulA Farbe grün Zeichnungsnummer Änd.Index SWITCH Power Limit NO (desactivado) Biral AG 3 00 961568 CH-3110 Münsingen OFF 961568_00 Véase sección 5.5.3 961568_00 Visum ... ... Farbe grünDatum Änd.Index Característica de regulación ajustadaSteuermodul en 3 BIM B2: Doppelpumpe (Pumpe passiv) Biral Impeller Drehung stehend LED brilla verde Muster blitzend Änd.Index Datum Betriebskontrolle Gegenstand Datum Steuermodul Steuermodul BIM BIM B2: B2: Doppe Doppe Steuer, PWM, Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Drehung stehend Muster blitzend Farbe grün ndex Steuermodul BIM B2: Doppe Steuermodul BIM B2: Doppe Zusatzmodule Betriebskontrolle 961204_00 09.04.2013 ts geprüft 1:1externo SWITCH 2 Apagado 09.04.2013 ts Freigabe OFF 961568_00 Véase sección 5.5.2 PDM_Nr TD-0021556 al Impeller Drehung drehend Muster normal Farbe grün Steuer, PWM, PWM, Hoval. Hoval. Pumpe Pumpe Steuer, normal Farbe Mustergrün ... Farbe ... Visum Ersetzt Ersatz für: SWITCH 1 durch: Aviso de avería OFF VéaseMassstab sección 5.5.1 gezeichnet 12.02.2013 dulA Steuer, PWM, Hoval. Pumpe Zusatzmodule Zusatzmodule Drehung stehend Muster blinkend Drehung drehend Farbe Musterrot normal Farbe rot Drehung stehend stehend proporcional Drehung Muster blitzend blitzend LED brilla amarilloMuster Farbe Farbe grün grün 961568_00 Betriebskontrolle Zusatzmodule Pumpe steht. Störung (Problemfälle) Drehung stehend Doppelpumpe Doppelpumpe (Pumpe (Pumpe passiv) passiv) Betriebskontrolle Presión Drehung stehend Muster blinkend Farbe rot Pumpe steht. Störung (Problemfälle) 7.10On-site adjustment of the pump Muster blitzend Drehung ... 3 ndex Drehung stehend stehend Drehung verde Muster blitzend Muster blitzend Farbe grün grün Farbe Drehung drehend rojonormal Muster Drehung stehend Drehung ... Farbe Muster blitzend Drehung Mustergrün ...drehend Farbe Muster Farbe grün ...normal Farbe rot Drehung Drehung drehend drehend Muster Muster normal normal Farbe grün grün Farbe Doppelpumpe Doppelpumpe (Pumpe (Pumpe aktiv) aktiv) Drehung stehend Muster normal Farbe grün Steuer, PWM, Hoval. Pumpe Pumpe steht. Störung (Problemfälle) Pumpe läuft normal Muster normal en N10 N9 N8 N7 N6 N5 Zusatzmodule Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 12.02.2013 ts ModulA 1:1 Biral Impeller Biral AG CH-3110 Münsingen geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021556 Zeichnungsnummer 961568 Änd.Index 00 60 | espagñol 8. Vista general de fallos y lista de comprobación Advertencia Antes de comenzar con la solución de averías ponga la bomba fuera de servicio, desconectándola de la red en todos sus polos y asegurándola contra reencendido. Sólo a cargo de personal especializado. ¡Pueden tocarse tensiones! Riesgo de escaldadura por medio que emana Zusatzmodule Steuer, PWM, Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Riesgo de quemadura por superficies calientes Drehung drehend Drehung stehend Muster blinkend Farbe rot Muster blitzend Farbe grün Pumpe steht. Störung (Problemfälle) Steuer, läuft PWM, Hoval. Pumpe gestoppt Pumpe normal Zusatzmodule Steuer, PWM, Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Pumpe steht. Störung (Problemfälle) Drehung stehend Drehung drehend Muster blitzend Muster normal Farbe grün Drehung drehend Muster normal Farbe rot Drehung drehend Muster blitzend Farbe grün Drehung stehend Muster blinkend Farbe rot Farbe grün En caso de no haber adaptador externo, repase la lista siguiente desde arriba hacia abajo, Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) paso a Extern paso. Si hay un adaptador remoto, causa del fallo se muestra directamente la Steuer, PWM, Hoval. Pumpeen gestoppt Pumpe läuft.la Störung (Problemfälle) Pumpe OFF Drehung drehend Drehung drehend Drehung stehend Muster blitzend Muster normal Muster blitzend Remote APP. Farbe grün Farbe rot Farbe grün Resumen fallos (Pumpe passiv) Steuermodul BIM de B2: Doppelpumpe Pumpe START/STOP von Taste oder App 1 La hélice Biral no se enciende Causa Solución Drehung stehend Drehung stehend Muster blitzend Muster normal Farbe grün Farbe grün Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) sin tensión de alimentación Controle el enchufe de alimentación y los fusibles Controle el enchufe y cable de alimentación Error de comunicación de sensor (*) Qué debe hacerse 1. Controle conectores del sensor 2. Reemplace el kit de sensor: ver Manual de instrucciones Kit de sensor ModulA ... 2 La hélice Biral gira en rojo (advertencia, bomba girando) Drehung ... Muster ... Farbe ... ModulA-...D mit BIM A2 Siganlmodul ... Doppelpumpe (Pumpe aktiv) Pumpe steht. Störung Doppelpumpe (Pumpe(Problemfälle) passiv) Änd.Index Datum ModulA Biral Impeller Drehung stehend Visum Ersetzt durch: Drehung stehend Muster blitzend blinkend Farbe grün rot 1:1 geprüft ... Subtensión 4. Controle la tensión de alimentación Zeichnungsnummer 961568 Drehung stehend Reconocimiento sin adaptador remoto Muster blitzend grün con el interruptor principa. 5.Apague la Farbe bomba Visum Ersetzt CuandoÄnd.Index la héliceDatum Biral parpadea endurch: rojo, la bomba Ersatz für: funciona en el modo operativo «turbinas», enMassstab casogezeichnet Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv)ModulA contrario, Drehung se trata de otro error. 1:1 geprüft drehend Änd.Index 00 Farbe grün Freigabe 12.02.2013 ts 09.04.2013 ts 09.04.2013 ts PDM_Nr TD-0021556 Qué debe hacerse Zeichnungsnummer Änd.Index 6. Controle, si la válvula antirretorno en la instalación Biral AG 00 961568 CH-3110 Münsingen está averiada. Sustituya la válvula antirretorno si es Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) necesario. Drehung stehend Muster blitzend 7. Controle, siFarbe la grün válvula antirretorno ha sido instalada en el lugar correcto de la instalación. ... Drehung ... Muster ... Farbe ... Drehung drehend Muster normal Farbe grün ... Drehung stehend Muster blitzend Farbe grün Drehung ... Muster ... Farbe ... Steuer, PWM, Hoval. Pumpe gestoppt Biral Impeller Muster blitzend 961568_00 Drehung ... Muster ... Farbe ... Modo turbina Muster normal drehend 09.04.2013 ts Freigabe Drehung PDM_Nr Farbe TD-0021556 rot Betriebskontrolle Biral AG CH-3110 Münsingen Muster blitzend Farbe grün 3. Controle la tensión de alimentación 09.04.2013 ts Drehung stehend Muster blitzend Farbe grün Reconocimiento sin adaptador remoto 1.Controle, si la bomba ha sido puesta en modo Stop (ver Manual de instrucciones, sección 7.7) 2. En caso afirmativo, la hélice Biral comienza a Steuer, PWM, Hoval. Pumpe auf Min,girar Normaler oder Max. enBetrieb rojo(cs)(ver «Error de comunicación sensor»), ... en caso contrario, Drehung drehendse trata de otro fallo. (74) Sobretensión (*) Massstab gezeichnet 12.02.2013 ts Pumpe läuft. Störung (Problemfälle) Muster blitzend Farbe grün Drehung stehend Muster normal Farbe grün Ersatz für: Drehung drehend Muster blitzend Farbe grün Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) DrehungPrimera ... 3 La hélice Biral parpadea en rojo Drehung medida a tomar, Muster ...drehend Muster Farbe ...normal (alarma, bomba no gira) cuando no hay adaptador Farbe grün remoto. Pumpe steht. Störung (Problemfälle) Zusatzmodule Drehung drehend Muster normal Farbe grün Drehung stehend Muster blitzend Farbe grün Drehung ... Muster ... Farbe ... espagñol | 61 Resumen de fallos Pumpe steht. Störung (Problemfälle) Causa 3 La hélice Biral parpadea en rojo Pumpe steht. Störung (Problemfälle) (alarma, bomba no gira) Drehung stehend Muster blinkend Farbe rot Drehung drehend Muster normal Farbe grün Pumpe läuft. Störung (Problemfälle) Drehung stehend Muster blitzend Farbe grün Zusatzmodule Solución Reconocimiento sin adaptador remoto Steuer, PWM, Hoval. Pumpe auf Min, Apague Normaler Betrieb oder Max.con el interruptor principal y vuel8. la (cs) bomba Drehung drehend va a encender. 3 segundos después de la conexión Muster blitzend a la red seFarbe realizan 3 intentos de desbloqueo. El grün relé de fallo conecta y parpadea al hélice Biral en rojo después de 20 segundos, de otro modo, se Steuer, PWM, Hoval. Pumpe gestoppt trata de otro tipo de fallo. Motor bloqueado Drehung drehend Muster normal Farbe rot Drehung stehend Muster normal Farbe grün Drehung stehend Muster blitzend Farbe grün Qué debe hacerse 9.Desmonte el cabezal de la bomba (ver Manual de instruccionesMotor ModulA) Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) 10.Retire algún cuerpo Drehung drehend extraño que podría encontrarse. Muster blitzend 11.Controle el rotor y, si está defectuoso, sustituya el Farbe grün motor. 12.Si el rotor está en buenas condiciones, vuelva a Steuermodul BIM B2: Doppelpumpe (Pumpe passiv)el cabezal de la bomba. (ver Manual de colocar Drehung stehendModulA) instruccionesMotor Muster blitzend Farbe grün Reconocimiento sin adaptador remoto 13.Fije velocidad de giro constante Nivel 1 y deje funcionando durante al menos un minuto. ... pasa a rojo, pues se trata de 13.1. S i laDrehung hélice Muster ... Farbe ... algún fallo. 13.2. S i la hélice permanece en verde, vaya al punto siguiente. 14.Fije velocidad de giro constante Nivel 6 y deje Drehung ... funcionando durante al menos un minuto. Muster ... Farbe ... 14.1. S i, dentro del primer minuto, se muestra un error, se trata de otro fallo. 14.2. S i, después de un minuto, la hélice pasa a rojo, se trata claramente de una alarma de marcha en seco. Marcha en seco ... Drehung drehend Muster normal Farbe grün ... Drehung stehend Muster blitzend Farbe grün Änd.Index Datum Visum Ersetzt durch: Ersatz für: Hay diferentes causas posibles para una alarma gezeichnet 12.02.2013 ts deMassstab marcha en seco: 09.04.2013 ts geprüft – A1:1 ire enFreigabe el sistema (marcha en seco efectiva: la Biral Impeller 09.04.2013 ts instalación ha sido llenada o purgada) PDM_Nr no TD-0021556 Zeichnungsnummer Änd.Index – M ayor presión del lado de succión que del lado de Biral AG 00 961568 CH-3110 Münsingen presurización. – Falsa alarma debida a un valor de medición erróneo (sensor atascado, perforación del sensor en carcasa taponada, casquillo del sensor mal colocado, sensor dañado) ModulA Qué debe hacerse 15.Controle si la instalación está llena con agua. 16.Controle si hay burbujas de aire en el sistema (ruidos). 17.Presione una tecla cualquiera para acusar recibo del error. 18.Fije la función de control de velocidad constante a Nivel 6, dejando funcionar al menos por un minuto. Si es posible, en contra de la llave de paso abierta y cerrada. 19.Si la hélice vuelve a ponerse en rojo después de un minuto, se trata de una alarma de marcha en seco. 20.Partiendo de la base, de que la instalación ha sido correctamente llenada y purgada, la alarma de marcha en seco podría ser una falsa alarma, disparada por un valor de medición erróneo. 21.Sustituya el sensor, o recurra el servicio técnico Biral. Avería interna (*) – ( 10) Error de comunicación – Error de hardware –E rror de acceso a memoria –E rror de corriente de encendido – Error RTC 22. S ustituya el Electronics ModulA o solicite asistencia al servicio técnico de Biral. Controle, si la bomba funciona en modo turbina (ver Modo turbina) o es atravesada por el flujo. 62 | espagñol 9. Sensor Al realizar trabajos de mantenimiento en el sensor o al reemplazarlo debe colocarse correctamente la cubierta hermética sobre el alojamiento del sensor. Advertencia Antes de sustituir el sensor debe asegurarse que la bomba esté desconectada y sin presión la instalación. X 5Nm 961612_00 X La nariz debe estar hacia abajo. Ajuste el tornillo de sujeción de abrazaderas con 5 Nm. 5Nm II I Änd.Index Datum Visum Ersetzt durch: ModulA Montage Sensor BA Biral AG CH-3110 Münsingen Ersatz für: Massstab gezeichnet 08.04.2013 ts 1:3 geprüft Ersatz für: Massstab gezeichnet 08.04.2013 ts 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0022120 Zeichnungsnummer Änd.Index 1:3 geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0022120 Zeichnungsnummer 961612 Änd.Index 00 espagñol | 63 10. Accesorio/Variante 10.1 Biral Remote El Biral Remote permite configurar y analizar la ModulA. La comu nicación inalámbrica con la ModulA es del tipo Wifi, estando equipada ésta con una interfaz para el adaptador Biral Remote. Aplicación Biral Remote La aplicación Biral Remote puede descargarse gratuitamente de iTunes y Play-Store. Sólo funciona con el hardware «Biral Remote Adapter. Posibilidades de ajuste y datos (extracto) Info Estado Tipo de bomba Caudal · Versión de software · Número de serie · Fecha de fabricación · Hora · [m³ / h] Configuración Modo de funcio namiento: · [m] · Funcionamiento ENC · Funcionamiento Parada · Velocidad mínima · Velocidad máxima Temp. del medio Tipo de regulación Altura de impulsión · [°C] Potencia · [W] Número de revoluciones · [rpm] · Presión proporcional · Presión constante · Velocidad constante Valor deseado · Ajuste · Característica de regulación Tipo de regulación Power Limit: Alarma actual Alarma actual · Fallo de comunicación · Fallo interno · Sobretensión · Subtensión · Impulsión forzada · Marcha en seco · Bomba bloqueada Advertencia actual · Avería de sensor · Avería interna Bitácora de alarma 1 Bitácora de alarma 2 Bitácora de ·P resión proporcional · Ajuste caudales, límite advertencias 1 (pp) ·P resión constante (cp) 25% … 90% de Q_max Bitácora de ·V elocidad constante Número de bomba advertencias 2 (cs) · Definición · Número de bomba Valor deseado para identificación · pp, cp [m] de BUS · cs [%] Horas de servicio · [h] Energía eléctr. · [kWh] Bloqueo de teclado · Bloquear teclas · Teclas desbloqueadas Tiempo · Ajuste de la hora interna de la bomba Biral Remote Adapter El Biral Remote Adapter (adaptador remoto de Biral) está equipado con Wifi y realiza la comunicación inalámbrica entre un smartphoney la bomba. Remote Adapter APP 64 | espagñol 10.2 B iral Interface Module, BIM A2 módulo de señal (para bombas autoreguladas) –– Indicador de funcionamiento o de disponibilidad –– Velocidad mínima externa –– Función bombas gemelas Observación: No es posible en combinación con módulo de control Diagrama de conexiones 10, 13 Velocidad mínima externa con contacto NA 61, 64Aviso de funcionamiento o disponibilidad (conmutable) como contacto normal-abierto: cierra en aviso de funcionamiento/disponibilidad 61, 62Aviso de funcionamiento o disponibilidad (conmutable) como contacto normal-cerrado: abre en aviso de funcionamiento/disponibilidad 91, 92 Función de bombas gemelas 961561_00 91 92 13 10 61 62 64 max. 250V AC 2A min. 5V DC 20 mA 10.3 Biral Interface Module, BIM B2 módulo de control (para bombas controladas) –– Consigna externa de velocidad 0–10 V/0–20mA –– Interfaz Multitherm o PWM. –– Función bombas gemelas Änd.Index Datum Observación: No es posible en combinación con módulo de señal II I Visum ModulA Ersetzt durch: 961562_00 Ersatz für: Massstab gezeichnet 25.01.2013 ts 12.02.2013 ts Anschlusschema 81 82 71 72 91 921:1 geprüft Diagrama de conexiones Freigabe 12.02.2013 ts BIM A2 PDM_Nr TD-0021438 81, 82 Interfaz Multitherm/PWM para consigna externa de velocidad Zeichnungsnummer Änd.Index Biral AG 71, 72Entrada analógica de 0…10 V o 0…20 mA para consigna CH-3110 00 961561 Münsingen externa de velocidad 91, 92 Función de bombas gemelas 10.4 M odelo para agua de calefacción y agua potable doméstica II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 25.01.2013 ts ModulA Anschlusschema BIM B2 Biral AG CH-3110 Münsingen 1:1 geprüft 12.02.2013 ts Freigabe 12.02.2013 ts PDM_Nr TD-0021440 Zeichnungsnummer 961562 Änd.Inde 00 espagñol | 65 11. Datos técnicos Tensión de alimentación 1×230 V ±10%, 50/60 Hz, PE Protección del motor No se necesita guardamotor externo Tipo de protección IP 44 (EN 60529) Clase de bobinaje Clase de aislamiento F Clase de temperatura TF 110 (EN 60335-2-51) Temperatura del medio –10 °C a +110 °C (ModulA GREEN) Maximum operating pressure máx. 40 °C durante el transporte: –40 °C a +70 °C Presión máx. de servicio La presión de servicio máx. admisible está indicada en la placa de características PN 6: 6bar PN 10: 10bar PN 16: 16bar Ruido El nivel de presión sonora se encuentra por debajo de dB(A) Corriente de derivación El filtro de red de la bomba ocasiona, durante su funcionamiento, una corriente de derivación a masa (tierra) <3,5 mA Consumo de potencia con bomba desconectada <3W Factor de potencia cos φ ModulA dispone de un filtro de corrección de factor de potencia (PFC). Él se encarga de que el coseno de fi se sitúe siempre entre 0,98 y 0,99 manteniéndose muy próximo al valor ideal 1. CEM (Compatibilidad electromagnética) EN 55014-1:2006, EN 55014-2:1997, EN 61000-3-3:2008 y EN 61000-3-2:2006 12. Eliminación Esta bomba de circulación ModulA ha sido desarrollada con una visión de sustentabilidad. Esto atañe también a la reducción de desechos y reutilizabilidad de los materiales. Tanto este producto como sus piezas deben eliminarse sin dañar el medioambiente y conforme a las directivas locales. 66 | espagñol 13. Lista de piezas de repuesto 6 3 1 7 961872_00 4 5 8 2 Número de artículo Biral ModulA… Pos. 1 Electronics con tapa neutra Pos. 2 Motor con junta tórica ModulA 32F-12 22 0300 0150 22 0404 0150 ModulA 40-8 22 0300 1650 22 0404 0250 ModulA 40-10 22 0300 0250 22 0404 0250 ModulA 40-12 22 0300 0350 22 0404 0350 ModulA 40-18 22 0300 0450 22 0404 0350 ModulA 50-6 22 0300 0550 22 0404 0450 ModulA 50-8 22 0300 1750 22 0404 0450 ModulA 50-12 22 0300 0650 22 0404 0550 ModulA 50-18 22 0300 0750 22 0404 0750 ModulA 65-8 22 0300 0850 22 0404 0850 ModulA 65-12 22 0300 0950 22 0404 0850 ModulA 65-15 22 0300 1050 22 0404 1050 ModulA 80-8 22 0300 1150 22 0404 1150 ModulA 80-12 22 0300 1350 22 0404 1150 ModulA 100-12 22 0300 1550 22 0404 1150 1 Stück II I Pos Gegenstand Änd.Index Datum Visum Material Ersetzt durch: Pos. 3 Pos. 4 ModulA GREEN BG3, BG4 Kit deErsatzteilliste sensor Tapa sin tornillos Biral AG CH-3110 Münsingen Modell/Art.Nr Bemerkung Ersatz für: Pos. 5 Enchufe 1:3.5 (L, N, PE) Massstab gezeichnet 17.12.2014 nma geprüft Freigabe PDM_Nr TD-0028878 Zeichnungsnummer 961872 Änd.Index 00 Biral RED 22 0033 0299 22 0301 0150 Biral GREEN 22 0033 0399 Biral BLUE 22 0033 0499 05 9123 9700 espagñol | 67 Número de artículo Biral ModulA… ModulA 32F-12 Pos. 6 Juego de sellado Pos. 7 Junta tórica Pos. 8 Juego para montaje en pared 05 2544 8499 22 0069 0100 00 1503 4600 ModulA 40-8 ModulA 40-10 ModulA 40-12 00 1503 4300 ModulA 40-18 ModulA 50-6 ModulA 50-8 ModulA 50-12 00 1503 4400 ModulA 50-18 ModulA 65-8 270 ModulA 65-8 340 ModulA 65-12 00 1503 4500 ModulA 65-15 ModulA 80-8 ModulA 80-12 ModulA 100-12 00 1503 0500 00 1503 0600 68 | română Cuprins 1. Indicaţii privind siguranţa....................................................................................................70 1.1 Generalităţi....................................................................................................................70 1.2 Marcarea indicaţiilor.......................................................................................................70 1.3 Calificarea şi instruirea personalului..............................................................................70 1.4 Pericole în cazul nerespectării indicaţiilor privind siguranţa..........................................70 1.5 Lucrul în siguranţă.........................................................................................................71 1.6 Indicaţii de siguranţă pentru operator/utilizator..............................................................71 1.7 Indicaţii de siguranţă pentru lucrările de montaj, întreţinere şi control...........................71 1.8 Modificările neautorizate şi producerea pieselor de schimb..........................................71 1.9 Moduri de funcţionare nepermise..................................................................................71 2. Simboluri utilizate.................................................................................................................72 3. Informaţii generale...............................................................................................................73 3.1 Domeniul de utilizare.....................................................................................................73 3.2 Cerinţe privind fluidul vehiculat......................................................................................73 3.3 Condiţii de funcţionare...................................................................................................74 3.4 Clapetă de sens.............................................................................................................75 3.5 Protecţia împotriva îngheţului........................................................................................75 3.6 Izolare............................................................................................................................75 3.7 Direcţia de curgere........................................................................................................75 4. Montajul..................................................................................................................................76 4.1 Informaţii generale.........................................................................................................76 4.2 Spălarea circuitului de încălzire (pompa demontată).....................................................76 4.3 Montajul.........................................................................................................................76 4.4 Poziţii de montaj permise...............................................................................................77 4.5 Montarea pompei în instalaţie........................................................................................78 4.5.1 Flanșa de racordare.............................................................................................78 4.6 Montarea convertizorului de frecvenţă...........................................................................79 4.7 Montare ştecher.............................................................................................................80 5. Racordarea electrică............................................................................................................81 5.1 Tensiunea de alimentare................................................................................................81 5.2 Conectarea la sursa de alimentare................................................................................82 5.3 Schemă de conectare Etichetare borne........................................................................83 5.4 Switch ajustes................................................................................................................84 5.4.1 Comutator 1, Mod diagnosticare sau mod operare (selectabil)...........................84 5.4.2 Comutator 2, Extern OPRIT sau extern PORNIT (selectabil)..............................85 5.4.3 Comutator 3, Power Limit (activabil)....................................................................85 română | 69 6. Punerea în funcţiune.............................................................................................................86 6.1 Generalităţi............................................................................................................................86 6.2 Controlul funcţionării..............................................................................................................86 7. Setări......................................................................................................................................87 7.1 Panoul de comandă.......................................................................................................87 7.2 Regimuri de automatizare..............................................................................................87 7.3 Înălţimea de pompare (A2)............................................................................................88 7.4 Afişarea debitului actual (LED V• )................................................................................88 7.5Prezentare generală a înălţimii maxime de pompare şi a debitului...............................88 7.6 Activarea/dezactivarea tastelor de comandă.................................................................89 7.7 PORNIRE/OPRIRE pompă............................................................................................89 7.8 Activare / dezactivare detectare funcționare uscată.......................................................89 7.9 Rotorul Biral...................................................................................................................90 7.10 Setarea din fabrică a pompei.........................................................................................90 8 Prezentarea defecţiunilor și Checklist................................................................................91 9.Senzor....................................................................................................................................93 10.Accesorii/Variante................................................................................................................94 10.1 Telecomanda Biral.........................................................................................................94 10.2 Modulul de semnalizare BIM A2 (pentru pompe autoreglabile).....................................95 10.3Modulul de comandă BIM B2 (pentru pompe controlate)..............................................95 10.4Varianta pentru încălzire şi apă caldă menajeră............................................................95 11.Date tehnice..........................................................................................................................96 12.Casarea..................................................................................................................................96 13.Lista pieselor de schimb......................................................................................................97 70 | română 1. Indicaţii privind siguranţa Avertisment Este permisă instalarea şi operarea acestui produs doar de persoane care dispun de cunoştinţe şi experienţă suficiente. Persoanele care au capacităţi fizice, mentale sau senzoriale reduse, au voie să utilizeze acest produs, doar în cazul în care au fost instruite suficient de o persoană care răspunde de siguranţa acestora. Produsul nu trebuie să fie lăsat la îndemâna copiilor. Nu este permisă utilizarea produsului de către copii, de ex. ca jucărie. 1.1 Generalităţi Aceste instrucţiuni de montaj şi de exploatare conţin indicaţii de bază, pe care trebuie să le respectaţi la instalare, în timpul funcţionării şi pentru întreţinere. De aceea, ele trebuie să fie citite obligatoriu înainte de montaj şi de punerea în funcţiune de către montator, precum şi de către personalul specializat/operatorul competent. Aceste instrucţiuni trebuie să fie disponibile întotdeauna la locul de utilizare a instalaţiei. Nu trebuie respectate numai indicaţiile generale privind siguranţa incluse în această secţiune «Indicaţii privind siguranţa», ci şi indicaţiile speciale privind siguranţa incluse în celelalte secţiuni. 1.2 Marcarea indicaţiilor Indicaţiile montate direct la instalaţie, ca de exemplu –– Direcţia de curgere –– Marcaje pentru racorduri trebuie respectate obligatoriu şi păstrate în stare perfect lizibilă. 1.3 Calificarea şi instruirea personalului Personalul pentru montaj, funcţionare, întreţinere şi inspecţie trebuie să deţină calificare corespunzătoare pentru aceste lucrări. Domeniul de responsabilitate, competenţa şi supravegherea personalului trebuie stabilite în mod precis de către utilizator. 1.4 Pericole în cazul nerespectării indicaţiilor privind siguranţa Nerespectarea indicaţiilor privind siguranţa poate avea drept urmare atât periclitarea persoanelor, cât şi a mediului şi instalaţiei. Nerespectarea indicaţiilor de siguranţă poate duce la pierderea oricăror pretenţii de despăgubire. În special, nerespectarea indicaţiilor poate cauza: –– Defectarea funcţiilor importante în instalaţie –– Imposibilitatea realizării metodelor prevăzute pentru întreţinere şi reparare –– Punerea în pericol a persoanelor din cauze electrice şi mecanice română | 71 1.5 Lucrul în siguranţă Trebuie respectate indicaţiile privind siguranţa incluse în aceste instrucţiuni de montaj şi exploatare, prevederile naţionale în vigoare pentru prevenirea accidentelor, precum şi eventualele prevederi interne referitoare la lucru, funcţionare şi siguranţă. 1.6 Indicaţii de siguranţă pentru operator/utilizator Trebuie eliminate pericolele cauzate de energia electrică (pentru detalii în acest sens, consultaţi, de exemplu, prevederile NIN (CENELEC)şi ale companiei locale de furnizare a energiei electrice). 1.7 Indicaţii de siguranţă pentru lucrările de montaj, întreţinere şi control Utilizatorul trebuie să se asigure că toate lucrările de montaj, întreţinere şi inspecţie sunt efectuate de personal specializat autorizat şi calificat, care s-a informat suficient prin studierea instrucţiunilor de montaj şi exploatare. În principiu, lucrările la instalaţie trebuie efectuate numai când aceasta este în repaus şi deconectată de la tensiune. Imediat după încheierea lucrărilor, toate dispozitivele de siguranţă şi protecţie trebuie montate la loc, respectiv repuse în funcţiune. Înaintea repunerii în funcţiune, trebuie respectate punctele incluse în secţiunea «Racordarea electrică». 1.8 Modificările neautorizate şi producerea pieselor de schimb Reechiparea sau modificările la pompe sunt permise numai în urma discuţiei cu producătorul. Piesele de schimb originale şi accesoriile autorizate de producător ajută la menţinerea siguranţei. Utilizarea altor piese exonerează producătorul de orice responsabilitate asupra consecinţelor. 1.9 Moduri de funcţionare nepermise Siguranţa în funcţionare a pompelor livrate este asigurată numai în cazul utilizării corespunzătoare conform secţiunii «Domeniul de utilizare» al instrucţiunilor de montaj şi exploatare. Valorile limită specificate în datele tehnice nu trebuie depăşite în niciun caz. 72 | română 2. Simboluri utilizate Avertizare Nerespectarea acestor instrucţiuni de securitate poate duce la vătămări corporale grave. Avertizare Tensiune electrică periculoasă. Dacă nu se respectă aceste instrucţiuni de securitate, există pericolul de electrocutare ce poate cauza vătămare corporală gravă sau moarte. Avertizare Pericol de vătămări corporale sau arsuri cauzate de suprafeţele fierbinţi! Avertizare Pericol de accidentare cauzată de obiecte în cădere! Avertizare Pericol de accidentare cauzată de pierderile de abur! Nerespectarea acestor instrucţiuni de securitate poate duce la defecţiuni sau daune materiale. Aici sunt prezentate sfaturi sau indicaţii, care facilitează lucrul şi garantează o funcţionare sigură. română | 73 3. Informaţii generale Seria Biral ModulA constă dintr-o gamă completă de pompe de circulaţie cu convertizor de frecvenţă integrat, care facilitează adaptarea independentă sau controlată a debitului la necesarul real al instalaţiei respective. Astfel s-a redus consumul de energie în multe instalaţii şi a fost îmbunătăţit controlul asupra instalaţiei. În plus, au fost reduse zgomotele produse de fluxul armăturilor de reglare. 3.1 Domeniul de utilizare Pompele de circulaţie Biral din seria ModulA sunt destinate circulaţiei lichidelor în următoarele instalaţii: –– ModulA GREEN în sistemele de climatizare şi răcire Pompele pot fi utilizate, de asemenea, în următoarele sisteme: –– Pompe de căldură geotermale –– Sisteme solare Pompele se pretează pentru utilizarea în instalaţii cu debit variabil şi constant. 3.2 Cerinţe privind fluidul vehiculat Pompa este adecvată pentru vehicularea mediilor curate lichide, neexplozive şi neagresive, fără componente solide sau cu fibre lungi, care pot ataca pompa mecanic sau chimic. –– Apa încălzită: Cerinţele specificate în standardele aplicabile pentru calitatea apei din instalaţiile de încălzire. –– Glicol: Pompa poate fi utilizată pentru pomparea amestecurilor de apă-glicol. Vâscozitate maximă admisă: 50 mm²/s (cSt). Acesta corespunde unui amestec de apă-etilen-glicol cu o proporţie de glicol de cca. 50% la –10 °C. Pompa este controlată printr-o funcţie de limitare a puterii, care are rolul de a proteja împotriva suprasarcinii. Pomparea amestecurilor de glicol are influenţă asupra curbei MAX, deoarece capacitatea de pompare se reduce în funcţie de conţinutul de glicol şi de temperatura mediului respectiv. Astfel, pentru ca acţiunea glicolului să nu fie diminuată, trebuie evitate temperaturile peste valoarea temperaturii nominale specificate pentru mediul respectiv. În general, trebuie minimizată durata de funcţionare cu temperaturi ridicate ale mediilor. Instalaţia trebuie curăţată şi clătită obligatoriu, înainte de adăugarea amestecului de glicol. Pentru a evita coroziunea sau precipitarea, amestecul de glicol trebuie verificat în mod regulat şi, după caz, schimbat. Dacă amestecul de glicol trebuie diluat mai mult, trebuie să respectaţi specificaţiile producătorului de glicol. În cazul pompării unui lichid cu o densitate şi/sau cu o vâscozitate cinematică diferită de cea a apei, capacitatea de transport este redusă. 74 | română Avertizare Pompele nu trebuie utilizate pentru transportul mediilor inflamabile, ca de ex. motorină şi combustibil. Avertizare Pompele nu trebuie utilizate pentru transportul lichidelor agresive, ca de exemplu acizi sau apă de mare. 3.3 Condiţii de funcţionare –– Temperatura mediului: ModulA GREEN –10 °C până la +110 °C –– Presiune de funcţionare: Presiunea de funcţionare maxim admisă este indicată pe plăcuţa de timbru. (6 bari, 10 bari sau 16 bari) Presiunea minimă de funcţionare la ştuţul de aspiraţie al pompei (presiune de admisie) la 500 m deasupra nivelului mării: Temperatura fluidului 75°C ModulA … 95°C 110°C Presiunea de pompare (bar) ModulA 32F-12 220 0.92 1.32 1.92 ModulA 40-8 220 0.12 0.52 1.12 ModulA 40-10 220 0.12 0.52 1.12 ModulA 40-12 250 0.12 0.42 1.02 ModulA 40-18 250 0.12 0.42 1.02 ModulA 50-6 240 0.12 0.12 0.72 ModulA 50-6 270 0.12 0.12 0.72 ModulA 50-8 240 0.12 0.12 0.72 ModulA 50-12 270 0.12 0.42 1.02 ModulA 50-18 270 0.22 0.62 1.22 ModulA 65-8 270 0.22 0.62 1.22 ModulA 65-8 340 0.22 0.62 1.22 ModulA 65-12 340 0.12 0.52 1.12 ModulA 65-15 340 0.42 0.82 1.22 ModulA 80-8 360 0.52 0.92 1.52 ModulA 80-12 360 0.52 0.92 1.52 ModulA 100-12 450 0.52 0.92 1.52 Pro ± 100 m înălțime ± 0.01 bar –– Temperatură ambientală: 0°C până la 40°C română | 75 3.4 Clapetă de sens În cazul în care este montată o clapetă de sens, pompa trebuie reglată (vezi punctul 7.2) astfel încât presiunea de pompare a pompei să depăşească întotdeauna presiunea de închidere a clapetei de sens. Acest lucru trebuie avut în vedere în special la reglarea presiunii proporţionale (înălţimea de pompare redusă la scăderea debitului). 961864_00 3.5 Protecţia împotriva îngheţului În cazul pericolului de îngheţ în timpul perioadelor de repaus al instalaţiei trebuie luate măsuri pentru evitarea deteriorărilor cauzate de îngheţ. 3.6 Izolare Pompa poate fi izolată împreună cu întregul sistem. A ăsaţi liberă deschiderea L de drenaj a motorului. A Nu acoperiţi niciodată convertizorul de frecvenţă cu izolaţie sau panoul de control. 3.7 Direcţia de curgere Săgeata de pe carcasa pompei indică direcţia de curgere. 961584_00 76 | română 4. Montajul 4.1 Informaţii generale ModulA este destinat exclusiv pentru montajul la interior. Pompele trebuie montate fără tensiune electrică, pentru ca asupra carcasei pompei să nu fie transferate forţe ale conductelor. Pompa poate fi montată direct pe conductă, cu condiţia ca aceste conducte să fie configurate pentru greutatea pompei. Montaţi pompa după încheierea tuturor lucrărilor de sudare şi de lipire la instalaţie. Evitaţi pe cât posibil picăturile de apă pe motorul pompei, în special pe convertizorul de frecvenţă. Avertizare Trebuie să respectaţi prevederile locale pentru ridicarea şi transportarea greutăţilor. Greutatea pompei este vizibilă pe ambalaj. 4.2 Spălarea circuitului de încălzire (pompa demontată) Pentru a preveni întreruperi nedorite ale funcționării pompei sau nepornirea pompei după perioade lungi de repaus, vă recomandăm ca în cazul unei instalații noi sau modificate, să goliți instalația după prima încălzire, să o spălați bine după care să o reumpleți. Instalația trebuie să corespundă stadiului actual al tehnicii. (Poziționarea vasului de expansiune respectiv a circuitului de siguranță). 4.3 Montajul Montajul trebuie să aibă loc doar după finalizarea tuturor activităților de sudură sau lipire din instalație. Evitați obligatoriu ca orice strop de apă să ajungă pe motorul pompei sau în special pe partea electronică. Montați carcasa pompei în instalație fără a introduce tensiuni. Rauhwerte Ra 12.5 6.3 3.2 1.6 0.8 0.4 Rauheitsklassen N10 Allgemeintoleranzen ISO 2768-mK N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 română | 77 4.4 Poziţii de montaj permise Arborele trebuie să fie întotdeauna orizontal, niciodată vertical. 961583_00 Pompa se livrează cu caseta de borne în stânga. 1 Stück II I Pos Gegenstand Änd.Index Datum Visum Material Ersatz für: 961585_00 ModulA GREEN Modell/Art.Nr Bemerkung Ersetzt durch: Massstab gezeichnet 15.02.2013 ts 1:4 Motor waagrecht für BA geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021617 Zeichnungsnummer Biral AG CH-3110 Münsingen Änd.Index 00 961583 961586_00 II I Änd.Index Datum Visum Ersetzt durch: 1:4.4 Montageposition Biral AG CH-3110 Münsingen II I Änd.Index Datum Ersatz für: Massstab gezeichnet 15.02.2013 ts ModulA GREEN Visum geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021620 Zeichnungsnummer Änd.Index 00 961585 Ersetzt durch: Ersatz für: Massstab gezeichnet 15.02.2013 ts ModulA GREEN Montageposition Stecker 3-6-9-12 Biral AG CH-3110 Münsingen 1:4.4 geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021621 Zeichnungsnummer 961586 Änd.Index 00 Caseta de borne nu trebuie orientată în jos, întrucât apa poate pătrunde cu uşurinţă. Înaintea montajului pompei, motorul poate fi rotit la 90°. Pentru aceasta, slăbiţi cele 4 şuruburi ale carcasei şi rotiţi capul motorului în poziţia dorită a motorului. Nu deplasaţi sau deterioraţi sigiliul dintre carcasa motorului şi a pompei. După montajul şuruburilor, strângeţi-le în diagonală. 78 | română 4.5 Montarea pompei în instalaţie ➀ Închideţi robineţii de izolare şi asiguraţi-vă că nu există presiune în instalaţie înainte de a monta pompa. ➁ Instalaţi etanşările pompei în conductă. 1 2 Avertizare Pericol de accidentare cauzată de pierderile de abur! 1 961589_00 4.5.1 Flanșa de racordare Flanşele pompei prezintă orificii de fixare PN6/PN10/PN16. Pentru o înşurubare sigură a flanşelor, trebuiesc montate şaibele livrate «B». II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 15.02.2013 ts ModulA GREEN Pumpe mit Absperrschieber Bild1 1:5 DN für BA geprüft Freigabe 18.02.2013 ts 18.02.2013 ts AZeichnungsnummer PDM_Nr Biral AG CH-3110 Münsingen TD-0021624 Änd.Index 00 961589 B Elementele de siguranţă (de ex. inele cu resort) nu sunt admise. Pentru PN 10/16 trebuie utilizate garnituri şi şuruburi speciale. 961590_00 Avertizare Utilizaţi şuruburile corespunzătoare pentru respectiva presiune nominală PN. Änd.Index II I A B M 960573_00 960573_00 Datum Visum DN 50 M für BA Biral AG CH-3110 Münsingen Ø Ø PN 6 PN 10 / 16 PN 6 PN 10 / 16 M 12 M 16 Ø 14 Ø 18 M 16 M 16 – – DN 65 DN 80 DN 100 Cuplul recomandat pentru strângerea şuruburilor: –– la M 12 <40 Nm –– la M 16 <95Änd.Index Nm Datum Visum Ersetzt durch: Ersatz für: II I Montajul flanşei combi cu flanşă combi nuMassstab este permis. Änd.Index Datum Flansch PN6/10/16 II für BA I Visum 1:2 gezeichnet 10.12.2014 nma geprüft Freigabe Ersetzt durch: PDM_Nr Biral AG Ersatz für: Massstab gezeichnet 15.02.2013 ts Pumpe mit Absperrschieber Bild2 1:5 DN 32 DN 40 Ersetzt durch: ModulA GREEN 10.12.2014 nma 10.12.2014 nma Ersatz für: TD-0028815 Zeichnungsnummer CH-3110 Münsingen Flansch PN6/10/16 960573 für BA Biral AG CH-3110 Münsingen Änd.Indexgezeichnet 10.12.2014 nma Massstab 00 1:2 geprüft 10.12.2014 nma Freigabe 10.12.2014 nma PDM_Nr TD-0028815 Zeichnungsnummer 960573 Änd.Index 00 geprüft 18.02.2013 ts Freigabe 18.02.2013 ts PDM_Nr TD-0021625 Zeichnungsnummer 961590 Änd.Index 00 română | 79 4.6 Montarea convertizorului de frecvenţă 100 238 230.5 961563_00 max 2m Între convertizor şi motor trebuie utilizat doar cablul de conectare original (2 m). II I Änd.Index ModulA Datum Massbild Visum 40 Ersetzt durch: Fixarea suportului de perete. Ersatz für: Massstab gezeichnet 25.01.2013 ts 8 Bausatz für abgesetzte Montage B 8x38 geprüft 15.02.2013 ts Freigabe 15.02.2013 ts PDM_Nr TD-0021441 C 5x40 Zeichnungsnummer 961563 Änd.Index 00 91 Biral AG CH-3110 Münsingen 1:4.4 961591_00 Avertizare Suportul trebuie montat întotdeauna pe verticală. Ataşare convertizor de frecvenţă. II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 18.02.2013 ts ModulA GREEN 1:2.5 Bausatzt kpl Wandmontage geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021630 Zeichnungsnummer Biral AG CH-3110 Münsingen 961593_00 II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 18.02.2013 ts ModulA GREEN 1:2.5 Bausatzt kpl Wandmontage Biral AG CH-3110 Münsingen geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021632 Zeichnungsnummer 961593 Änd.Index 00 961591 Änd.Index 00 80 | română 4.7 Montare ştecher − Introduceţi cu atenţie ştecherul pe partea motorului ➀ −S trângeţi şuruburile M6×40 ➁ ➀ ➁ 961594_00 – I ntroduceţi cablul senzo rului ➂ –M ontaţi garnitura cablului ➃ ➂ II I Änd.Index Datum Visum ➃ Ersetzt durch: Ersatz für: Massstab gezeichnet 18.02.2013 ts ModulA GREEN Stecker für Motor 961595_00 –F ixaţi capacul ➄ cu 3 şuruburi Biral AG CH-3110 Münsingen 1:3.5 geprüft 02.04.2013 ts Freigabe 02.04.2013 ts PDM_Nr TD-0021638 Zeichnungsnummer 961594 ➄ Änd.Index 00 română | 81 5. Racordarea electrică Racordarea electrică trebuie efectuată în conformitate cu prevederile locale. Trebuie să aveţi grijă ca tensiunea şi frecvenţa indicate pe plăcuţa de timbru să corespundă cu sursa de alimentare existentă. Avertizare Înainte de a efectua orice lucrare de conectare electrică, tensiunea de alimentare trebuie oprită. Pompa trebuie conectată la un comutator de reţea cu un diametru minim al orificiului de contact de minim 3 mm pentru fiecare pol. Protecţia împotriva atingerii indirecte se poate realiza prin împământare sau egalizarea potenţialelor. Dacă pompa este conectată la o instalaţie electrică care dispune de un întrerupător automat pentru curentul de descărcare ca protecţie suplimentară, acesta trebuie să se declanşeze la apariţia curenţilor reziduali de împământare cu componente de curent continuu intermitent. Comutatoarele FI trebuie marcate cu simbolul indicat: Externer Schalter FI L N L N Sicherung (min.10A, träge) Pompa nu are nevoie de protecţie externă a motorului. Motorul are o protecţie la temperatură inclusă, protecţie la suprasarcină care apare lent şi împotriva blocării IEC 34-11: TP 211. 5.1 Tensiunea de alimentare 1×230V ±10%, 50 / 60 Hz, PE Toleranţele de tensiune sunt destinate compensării fluctuaţiilor de tensiune în reţea. 961807_00 Pompa nu este destinată să funcţioneze la alte tensiuni, în afară de cele indicate pe plăcuţa de timbru. Dacă este conectată direct la reţea, pompa nu trebuie pornită şi oprită mai frecvent de patru ori pe oră. Dacă pompa este comutată direct prin reţea, aceasta va porni cu o întârziere de 5 secunde. 82 | română 5.2 Conectarea la sursa de alimentare Pompa este asigurată local (min. 10 A, întârziere la acţionare) şi conectată la un comutator de reţea extern. Toate cablurile utilizate trebuie să fie rezistente la căldură de până la 85 °C. Acestea nu trebuie să intre în contact cu conducta, carcasa pompe sau a motorului. Toate cablurile trebuiesc conectate în conformitate cu EN 60204-1 şi EN 50174-2: 2000. Racordarea electrică trebuie efectuată conform celor indicate pe plăcuţa de timbru. Pentru înlocuirea mai uşoară în viitor, vă recomandăm să înfăşuraţi cablul într-o buclă. ModulA… Corriente nominal [A] ModulA 32F-12 220, ModulA-D 32F-12 220 0.17 – 1.50 Potencia P1 [W] 16 – 328 ModulA 40-8 220, ModulA-D 40-8 220 0.20 – 1.21 20 – 268 ModulA 40-10 220, ModulA-D 40-10 220 0.19 – 1.54 18 – 341 ModulA 40-12 250, ModulA-D 40-12 250 0.18 – 1.91 17 – 421 ModulA 40-18 250, ModulA-D 40-18 250 0.18 – 2.63 16 – 594 ModulA 50-6 240, ModulA-D 50-6 240 0.21 – 1.09 21 – 236 ModulA 50-6 270 0.21 – 1.09 21 – 236 ModulA 50-8 240, ModulA-D 50-8 240 0.21 – 1.42 22 – 315 ModulA 50-12 270, ModulA-D 50-12 270 0.21 – 2.32 20 – 516 ModulA 50-18 270, ModulA-D 50-18 270 0.21 – 3.34 22 – 742 ModulA 65-8 270 0.24 – 2.10 22 – 464 ModulA 65-8 340, ModulA-D 65-8 340 0.24 – 2.10 22 – 464 ModulA 65-12 340, ModulA-D 65-12 340 0.22 – 3.32 21 – 736 ModulA 65-15 340, ModulA-D 65-15 340 0.28 – 5.68 30 – 1254 ModulA 80-8 360, ModulA-D 80-8 360 0.29 – 3.08 29 – 704 ModulA 80-12 360, ModulA-D 80-12 360 0.32 – 5.56 32 – 1282 ModulA 100-12 450, ModulA-D 100-12 450 0.32 – 6.78 35 – 1563 FI Comutator 2 extern N N L L Siguranţă: (min. 101 A, întârziere la acţionare) 961613_02 Exemplu de conexiune tipică la reţea, 1×230 V ±10%, 50/60 Hz Legende: 1 Sicherung (min.10A, träge) 2 Externer Schalter română | 83 5.3 Schemă de conectare Etichetare borne Alimentarea cu tensiune: 1x230V +/- 10%, 50/60Hz bornelor de legătura: L, N, PE Racordare la reţea +24- 24 V DC out 11, 10OPRIRE externă sau PORNIRE externă (comutabil) 52, 54, 51Mesaj de avarie sau de funcţionare Comutator: 1 Mod diagnosticare sau mod operare (selectabil) 2 Extern OPRIT sau extern PORNIT (selectabil) 3 Power Limit (activabil) Switch DC out 24V max. 20mA 11 10 52 54 51 max. 250V AC 2A min. 5V DC 20mA II I Änd.Index Datum Visum L N AC in ~1x230V ±10% 50/60 Hz Ersetzt durch: 961566_00 +2 4- Ersatz für: Massstab gezeichnet 08.02.2013 ts ModulA 750W Anschlussschema mit FU für BA Biral AG CH-3110 Münsingen 1:2 geprüft 15.02.2013 ts Freigabe 15.02.2013 ts PDM_Nr TD-0021543 Zeichnungsnummer 961566 Änd.Index 00 84 | română 5.4 Setările contactoarelor Comutator 1 II I ON II I ModulA Mod operare Änd.Index ON 1 ON 1 II I Änd.Index Änd.Index 52 54 51 Datum Visum 52 54 51 II I Datum Datum Ersetzt Ersatz für:durch: Ersetzt durch: Paleta ONîn rotire ON Änd.Index 52 Mod operare ON2 inactiv Relaisaugänge1:1 ON2 ModulA ModulA Relaisaugänge Massstab gezeichnet 13.11.2014 Freigabe PDM_Nr TD-0028419 Freigabe PDM_Nr 5252 5454 5151 52 54 51 Änd.Index 00 52 54 51 1 2 3 961865_01 ON 01 II Datum I Änd.Index 16.01.2015 Visum ON ts Datum Änd.Index Ersetzt Visum durch: II I Ersetzt durch: Datum Visum Ersatz für: Ersetzt durch: Ersatz für: Änd.Index Datum Visum 01 16.01.2015 ts Freigabe Freigabe 51,52,54 PDM_NrTD-0028816 TD-0028419 PDM_Nr Biral AG Zeichnungsnummer Zeichnungsnummer Ersetzt durch: Ersatz für: Massstab gezeichnet 10.12.2014 nma 3:1 Switch 3 geprüft Freigabe PDM_Nr Biral AG CH-3110 Münsingen 1:1 3:11:1geprüftgeprüft Relaisaugänge Biral AG Biral AG 961827Münsingen CH-3110 Münsingen CH-3110 961865 CH-3110 Münsingen ModulA Ersatz für: Massstab gezeichnet 13.11.2014 ts Massstab gezeichnet 10.12.2014 Massstab gezeichnet 13.11.2014 nma ts ModulA ModulA Switch 3Relaisaugänge 3 51,52,54 3 II I TD-0028816 Zeichnungsnummer 961865 Änd.Index 01 geprüft Freigabe PDM_Nr TD-0028419 Zeichnungsnummer Änd.Index Änd.Index 961827 00 01 Änd.Index 00 961827_00 6 6 6 6 6 6 6 8 8 8 8 6 6 6 6 6 6 8 961827_00 961827_00 8 6 6 ts TD-0028419 Änd.IndexZeichnungsnummer +2 4 6 00 operare inactiv ts Massstab gezeichnet 13.11.2014 geprüft 1:1 geprüft 51,52,54 Änd.Index 961827 00 54 51 Ersatz für:Mod 00 Biral AG Biral AG 3 3 CH-3110 961827Münsingen 00961827 CH-3110 Münsingen ON Änd.Index 6 8 6 operare activ Paleta în repaus 961827 CH-3110 Biral AG Münsingen Biral AG Biral AG Münsingen CH-3110 Zeichnungsnummer CH-3110 Münsingen Änd.Index Datum Visum Münsingen 961827 Visum AG Münsingen Biral Ersetzt Ersetzt durch:5252 für: durch: 54 CH-3110 51 52 54 CH-3110 51 51 Ersatz II I CH-3110 Münsingen 54 961827 Datum 17.10.2014 ts 961827_00 6 00 8 Änd.Index 00 DC ou 24V max. 20 6 TD-0028423 +2 4 6 961808 geprüft CH-3110 Münsingen Freigabe PDM_Nr Ersatz für: DC ou 24V max. 20 Ersatz für: Zeichnungsnummer 1 2 3 3.3 5 Pompa dispune de un releu geprüft Paleta în rotire Visum Visum +2 4 +2 A4 ~1x230 Freigabe 17.10.2014 ts Ersatz für: PDM_Nr TD-0026660 Massstab gezeichnet 13.11.2014 Zeichnungsnummer ts Änd.Index 52 54 51 52 54 51 Ersatz für:Mod Zeichnungsnummer ModulA 8 8 6 fault mit FU für signal BA inactive Biral AG1:1 Paleta în rotire Visum 10 5 liber de potențial pentru o semnalizare externă a erorii. Releul de semnalizare poate fi comutat în modul operare cu 1:2ajutorul comutatorului 1. Ersetzt durch: Paleta roșu Biral AG 961828 CH-3110 Münsingen Mod diagnos ticare activ 5454 5151 52 Mod52operare activ 52 Massstab gezeichnet 16.10.2014 ts Anschlussschema Visum Ersetzt durch: Klemme 11, 10 DC ou 24V DC20 o max. 24V 54 51 max. 20 max. 250V AC max. 250V AC AC in AC in 2A ~1x230V ±10%2A ~1x230V ±10% min. 5V DC 50/60 min. Hz 5V DC 50/60 Hz 20mA 20mA Ersetzt Ersatz für: Ersetzt durch: für:durch: Massstab Ersatz gezeichnet 13.11.2014 ts Massstab gezeichnet 13.11.2014 ts IIIIVisum II ModulA Ersetzt durch: Ersatz für: geprüft Massstab 1:1 gezeichnet 1:1 geprüft gezeichnet 13.11.2014 13.11.2014 ts ts Massstab ModulA gezeichnet 13.11.2014 ts Massstab ModulA Relaisaugänge ModulA Relaisaugänge Freigabe geprüft MassstabFreigabe gezeichnet 13.11.2014 ts1:1 geprüft geprüft ModulA 51,52,54 51,52,54 Relaisaugänge1:1 Relaisaugänge PDM_Nr TD-0028419 PDM_Nr TD-0028419 Relaisaugänge Freigabe geprüft Freigabe Freigabe 1:1 51,52,54 Änd.Index 961865_01 Relaisaugänge Zeichnungsnummer Änd.IndexZeichnungsnummer 51,52,54 51,52,54 PDM_Nr TD-0028419 Freigabe TD-0028419 PDM_Nr TD-0028419 Biral AGPDM_Nr Biral AG Zeichnungsnummer Änd.Index 51,52,54 Zeichnungsnummer Änd.Index Zeichnungsnummer Änd.Index PDM_Nr TD-0028419 00 961827 00 51,52,54 II I Visum 5 3.3 50/6 5 de semnalizare un contact 52 N cu +254 4-51 11L10 52 54 51 L N AC in ~1x230V ±10% 50/60 Hz Datum 11 10 5 24V 3.3 max. 20mA 961828_00 11 10 Paleta ONroșu ON Mod52diagnos 52 5454 5151 52 54 51 5252 5454 5151 52 54 51 ticare 5252 5454 51 252 2 52 54 51 52 5451 51 activ Änd.Index Datum Ersetzt durch: Änd.Index Datum Änd.Index Datum 5 8 II L N+2 4- ModulA BG2 ModulA ON 52525454 5151 Visum Änd.Index 52 54 51 52 54 51 Änd.Index Datum I 52 54 51 5 10 6 6 24V max. 20mA Paleta verde II I inactive 00 52 54 51 52 54 51 52 52154 54 51 51 1 II I Status 52 54 51 Paleta verde ON 961827_00 961827_00 961827_00 8 6 88 8 6 Betrieb EIN 5 Conector 52 54 51 5252 5454 5151 5254 5451 51 52 54 51 Status 5252 10.12.2014 nma 3:154 geprüft 52 51 52 52 5454 5151 10.12.201452 nma54 51 52 54 Freigabe 51 52 54 51 52 54 51 52 52 54 51 52 52Zeichnungsnummer 54PDM_Nr 51 TD-0028816 5254 5451 51 fault signal Änd.Index 961865 N 5 6 6 Betrieb AUS Ersatz für: ON L 11 10 ON Massstab gezeichnet 10.12.2014 nma CH-3110 Münsingen N NN 6 66 6 Betrieb AUS 6 11 10 961808_00 Ersetzt durch: Comutator 1 Biral AG OFF L LL out max. 250V AC AC inmax. 250V AC DC 24VAC in 2A ~1x230V ±10%2A 10 max. 20mA ±10% ~1x230V min. 5V DC 50/60 min. Hz 5V DC 50/60 Hz 20mA 20mA 6 Switch 3 Visum 5 +2 4Switch 2 Extern EIN Datum Mod diagnosticare Änd.Index ModulA 5 OPRIT (OFF) 52+2544-51 N 54 51 11L10 52 11 10 8 Betrieb EIN 5.4.1 Comutator 1, Mod diagnosticare sau mod operareDC(selectabil) out DC out 52 54 54 51 51 52 5 3.3 3.3 3.3 66 11 10 +2 4- externă 6 6 8 11OPRIRE 10 Caractere aldine = Setare din fabrică Conector 52 54 51 5 5 5 961827_00 5 10 10 961827_00 8 66 66 6 5 5 5 5 10 3.3 88 3.3 AC max.max. 250V250V AC AC AC inmax. AC in Klemmen AC in250V 2A 2A 2A5 ~1x230V ±10% 10% ±250V ±max. AC ~1x230V ~1x230V 10% max. 250V AC gebrückt DC out max. 250V ACininHz AC in max. AC min. 250V 5V DC 5V DC 5min. min. 5VAC DC AC 5 50/60 50/60 2A Hz 2A 5Hz 10 24V 3.32A 5 ~1x230V ±10% ~1x230V50/60 20mA ±10%2A 20mA 20mA ~1x230V ±10% 10 3.3 DC min. 5V 5V min. DC min.5V20mA 5V DC max. 50/60Hz Hz DC 50/60 min. Hz 50/60 20mA 20mA 20mA 20mA 8 8 Mesaj de avarie Borne 52, 54, 51 OFF 6 6 6 6 6 8 6 8 8 6 6 6 6 6 6 5 8 Switch 2 Extern AUS OPRIT 1 2 3 5 11L 10L N 52 54 524-51 54 51 N 51 +2 +2 4- 4-11 11 10 1052+2 54 +2 4-51 11L10 10 52 52 54 51 51 +2 54 N +24-4- 11 1110 10 52 52 54 5111 PORNIRE PORNIT (ON) +2 454 Mesaj de funcţionare Borne externă DC out Ausganslage 24V 52, 54, 51 max. 20mA 961865_00 5 DC out 24V 5 5 10 10 6 ON Contactorul 3 5 8 PORNIT DC out DC out 24V24V5 DC20mA out3.3 DC out max. 20mA 10 sau max. max. 20mA DC outLimitarea DC out OPRIRE externă 24V 24V 24V 24V max. 20mA max. 20mA max. 20mA Switch 20mA PORNIRE externă max. Puterii 961827_00 961827_00 Contactorul 25 Mesaj de avarie sau de funcţionare 6 Contactorul 1 Funcţie română | 85 5.4.2 Comutator 2, Extern OPRIT sau extern PORNIT (selectabil) Klemmen DC out Ausganslage 24V max. 20mA ConectorStatus Switch 2 Switch 2 4+2 11 11 10 10 52 54 51 DC out 24V 2OFF max. 20mA ON SwitchON Switch 2 ON +2 2 4- 6 Betrieb EIN Visum 01 16.01.2015 ts ModulA 33 Switch Ersetzt durch: Massstab gezeichnet 10.12.2014 nma 3:1 3 geprüft Freigabe 16.01.2015 ts Änd.Index 01 961865 L N Ersetzt durch: TD-0028816 Zeichnungsnummer Biral AG CH-3110 Münsingen Visum Betrieb EIN Ersatz für: PDM_Nr Datum Betrieb AUS 961828_00 Ersatz für: Massstab gezeichnet 10.12.2014 nma 3:1 3 ts Freigabe Ersetzt durch: AC in Biral AG Massstab gezeichnet 10.12.2014 nma 961865 CH-3110 Münsingen ~1x230V ±10% geprüft Änd.Index 3:1 Freigabe PDM_Nr ModulA 961865 Ersetzt durch: Klemme 10durch: L NVisum 11,Ersetzt Datum 961808_00 Ersatz für: Massstab gezeichnet 13.11.2014 01 Ersatz für: 1:1 ±10% Änd.Index Datum mit FU für BA~1x230V 50/60 Hz II I Freigabe Biral AG ModulA PDM_Nr TD-0026660 Ersetzt durch: Ersatz für: Zeichnungsnummer Änd.Index Massstab gezeichnet 13.11.2014 CH-3110 Münsingen Visum 11, 10 Klemme Ersetzt durch: Datum ModulA BG2 Anschlussschema mit FU für BA TD-0028423 Massstab gezeichnet 16.10.2014 ts Power Limit ENC Zeichnungsnummer Biral AG geprüft 17.10.2014 ts 1:2 Rango de ajuste CH-3110 Münsingen Freigabe 961828 17.10.2014 ts Visum 961808 1:1 Ersatz für: 00 Änd.Index 00 ts geprüft Freigabe PDM_Nr TD-0028423 Massstab gezeichnet 16.10.2014 ts Zeichnungsnummer Änd.Index Biral AG 1:2 geprüft 17.10.2014 ts Freigabe 961828 17.10.2014 ts CH-3110 Münsingen PDM_Nr Biral AG CH-3110 Münsingen ts geprüft PDM_Nr AC in Anschlussschema I Visum Änd.Index ModulA BG2 Änd.Index 01 TD-0028816 Zeichnungsnummer Biral AG CH-3110 Münsingen Änd.Index Datum 50/60 Hz II I I geprüft PDM_Nr TD-0028816 Ersatz für: Zeichnungsnummer Änd.Index 961808_00 Visum 5 TD-0026660 Zeichnungsnummer 961808 Änd.Index 00 8 11 10 6 ON 3 ON Datum +2 46 961828_00 3 Extern EIN 3 ON 10 5 6 11 10 2A min. Betrieb 5V DC AUS 20mA 5.4.3 Comutator 3, Power Limit (activabil) • ON ON1 2 3 Limita2de putere (limitarea debitului volumului V ) Switch 11 10 11 10 961865_01 961828_00 poate fi activată în această pompă. Änd.Index 5 8 11 10 Operare Betrieb PORNIT AUS 11 10max. 250V AC OFF ON 2 ON 1 2 3 ON 961865_01 3 gebrückt min. 5V DC 20mA Operare Betrieb OPRIT EIN Switch 2 961865_01 ON 2 ON 1 max. 250V AC Ausganslage 2A 11 11 10 10 52 54 51 2 PORNIT2 ON 1 2 3 ON 1 ON 2 8 Extern PORNIT ON Extern Extern EIN AUS 1 Switch 1 6 ON Operare Betrieb Klemmen OPRIT AUS 6 ON 11 10 Operare Betrieb ON PORNIT EIN 6 OPRIT Intrare digitală Intrarea digitală poate fi utilizată pentru o comutare externă PORNIT/OPRIT a pompei. Cu ajutorul comutatorului 2 este posibil a se comuta între Extern OP-5 DC out RIT și EXTERN PORNIT. 24V max. 20mA 10 Indicație: Dacă nu este conectat un comutator +2 4- 11 PORNIT/OPRIT, pompa funcționează când comutatorul 2 se află în 5 DC out poziția OFF iar la clemele 24V max. nici 20mA 11, 10 nu este prinsă o 10 punte. Aceasta este setarea de fabrică. 5 6 Extern OPRIT Extern AUS ON gebrückt ConectorStatus 8 Switch 00 Debitul maxim presetat se află la capătul curbei 3 (presiune proporțională). Prin intermediul Biral Remote poate fi limitat debitul volumului la valori între 25...90%. 5 86 | română 6. Punerea în funcţiune 6.1 Generalităţi Înainte de punerea în funcţiune, instalaţia trebuie umplută cu lichid şi aerisită. De asemenea, la orificiul de admisie al pompei trebuie aplicată presiunea de admisie minimă. Instalaţia nu poate fi aerisită prin pompă. Pompa este cu auto-ventilare. 6.2 Controlul funcţionării Pumpe steht. Störung (Problemfälle) După pornirea tensiunii de alimentare, pompa trebuie să pornească automat: rotorul Biral se învârte şi luminează verde. Pumpe steht. Störung (Problemfälle) Pumpe läuft normal Drehung Muster b Farbe ro Drehung drehend Muster normal Farbe grün Pompa funcţionează în conformitate cu setările de bază (Vezi secţiunea 7.9) Pumpe läuft. Störung (Problemfälle) Pumpe Extern OFF Drehung stehend Muster blitzend Farbe grün Drehung Muster n Farbe ro Pumpe START/STOP von Taste oder App Drehung stehend Muster normal Farbe grün ModulA-...D mit BIM A2 Siganlmodul Doppelpumpe (Pumpe aktiv) Drehung drehend Muster normal Farbe grün Doppelpumpe (Pumpe passiv) Drehung stehend Muster blitzend Farbe grün Betriebskontrolle Änd.Ind Modu Bira 961568_00 română | 87 7. Setări Avertizare Există pericolul de arsuri! În cazul temperaturilor înalte ale lichidului, pompa poate deveni atât de fierbinte, încât se pot atinge numai tastele de 6.3 3.2 1.6 0.8 N9 N8 N7 N6 6.3 3.2 1.6 0.8 N9 N8 N7 N6 7.1 Panoul de comandă A1Tastă de comandă pentru setarea regimului de automa tizare vezi secţiunea 7.2 A2Taste de comandă pentru setare (a înălţimii de pompare) cu simboluri cu LED pentru afişarea înălţimii de pompare 0.4 Allgemeintoleranzen ISO 2768-mK N5 şi a regimului de automatizare vezi secţiunea 7.3 über 6 bis 30 über 30 bis 120 über 120 bis 400 über 400 bis 1000 0.5 bis 6 LED 1 afişarea curbei caracteristice selectate (treapta) ± 0.2 ± 0.3 ± 0.5 ± 0.8 ± 0.1 • LED 2 afişarea debitului actual V (25…100%) 0.4 LED 3 rotorul Biral indică Allgemeintoleranzen ISOstarea 2768-mKpompei vezi secţiunea 7.9 N5 Rauhwerte Ra 12.5 B 0.5 bis 6 Punct conectare pentru telecomanda über 6 bis 30de über 30 bis 120 übera 120adaptorului bis 400 über 400 bis 1000 Rauheitsklassen N10 ± 0.2 ± 0.1 ± 0.3 ± 0.5 ± 0.8 6.3 3.2 1.6 0.8 0.4 Allgemeintoleranzen ISO 2768-m N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 40 ± 0.5 7.2 Regimuri de automatizare 6.3 3.2 1.6 0.8 0.4 Allgemeintoleranzen ISO 2768-mK Tastă de comandă N9 N8 N7 N6 N5 0.5 bis 6 ± 0.1 über 6 bis 30 ± 0.2 über 30 bis 120 ± 0.3 über 120 bis 400 ± 0.5 über 400 bis 1000 ± 0.8 Regimul de funcţionare cu automatizare: Presiune proporţională (pp) Adecvat în următoarele instalaţii: – Sisteme cu două conducte cu robineţi termostataţi şi • lungimi mari ale conductelor • Robineţi cu gamă largă de funcţionare • Pierdere mare de presiune – Pompe montate pe circuitul primar cu pierdere mare de presiune Regimul de funcţionare cu automatizare: Presiune constantă (cp) Adecvat în următoarele instalaţii: 961204_00 – Sisteme cu două conducte cu robineţi termostataţi şi • înălţimea de pompare >2 m • Circulaţie naturală – cu pierderi de presiune foarte reduse 961204_00 – Pompe montate pe circuitul primar în instalaţiile cu pierderi de presiune reduse – Instalaţii de încălzire în pardoseală cu robineţi termostataţi – Instalaţii de încălzire cu o conductă genstand Datum Visum 52 ab 2009 961204_00 Regimul de funcţionare fără automatizare: Turaţie constantă (cs) Pos Gegenstand Stück Änd.Index Datum Visum Punctul de funcţionare se poate seta prin reglarea Ersetzt durch: Modell/Art.Nr Bemerkung Pos961204_00Material II I turaţiei (tastele A2). Adecvat pentru instalaţiile cu debit A402 - A652 ab 2009 Ersetzt durch: constant: instalaţii Ersatzde für: climatizare, pompe de căldură, Regelungsart Zyklus pompe pentru cazane etc. Massstab gezeichnet 07.01.2009 ts ngsart ZyklusPos egenstand Datum Ciclul regimului de automatizare Visum Biral AG 52 ab 2009 Material Ersetzt durch: CH-3110 Münsingen ngsart Zyklus 1:1 geprüft 20.03.2009 ts Freigabe 20.03.2009 ts Modell/Art.Nr Bemerkung PDM_Nr Ersatz für: TD-0011003 Zeichnungsnummer Änd.Index Massstab gezeichnet 07.01.2009 ts 961204 1:1 geprüft 00 20.03.2009 ts Freigabe 20.03.2009 ts PDM_Nr TD-0011003 Material BA Biral AG CH-3110 Münsingen Modell/Art.Nr B Ersatz für: Massstab gezeichnet 07.0 1:1 geprüft 20.0 Freigabe 20.0 PDM_Nr TD- Zeichnungsnummer 961204 88 | română 7.3 Înălţimea de pompare (A2) Valoarea nominală a pompei se poate seta prin apăsarea tastei sau . Exemplu: de ex. LED-ul 3 luminează (verde): Caracteristica 3 LED-urile 3 şi 4 luminează (verde): Caracteristica între 3 şi 4 Dacă radiatoarele nu se încălzesc suficient, setaţi următoarea caracteristică mai mare. • 7.4 Afişarea debitului actual (LED V ) • V = 25, 50, 75, 100% 7.5 P rezentare generală a înălţimii maxime de pompare şi a debitului ModulA… • Hmax [m] Vmax [m3 / h] ModulA 32F-12 220, ModulA-D 32F-12 220 12 17 ModulA 40-8 220, ModulA-D 40-8 220 8 18 ModulA 40-10 220, ModulA-D 40-10 220 10 21 ModulA 40-12 250, ModulA-D 40-12 250 12 24 ModulA 40-18 250, ModulA-D 40-18 250 18 28 ModulA 50-6 240, ModulA-D 50-6 240 6 25 ModulA 50-6 270 6 25 ModulA 50-8 240, ModulA-D 50-8 240 8 27 ModulA 50-12 270, ModulA-D 50-12 270 12 33 ModulA 50-18 270, ModulA-D 50-18 270 18 37 ModulA 65-8 270 8 36 ModulA 65-8 340, ModulA-D 65-8 340 8 36 ModulA 65-12 340, ModulA-D 65-12 340 12 33 ModulA 65-15 340, ModulA-D 65-15 340 15 58 ModulA 80-8 360, ModulA-D 80-8 360 8 54 ModulA 80-12 360, ModulA-D 80-12 360 12 57 ModulA 100-12 450, ModulA-D 100-12 450 12 74 română | 89 7.6 Activarea/dezactivarea tastelor de comandă Prin apăsarea simultană a tastei (minimum 3 sec.) şi se dezactivează sau se activează toate tastele de comandă din panoul de control. 7.7 PORNIRE/OPRIRE pompă Apăsaţi tasta (3 secunde) pentru schimbarea modului de funcţionare (PORNIT sau OPRIT). 7.8 Activare / dezactivare detectare funcționare uscată Prin apăsarea simultană a tastei, , și (10. Sek.) se activează/ dezactivează funcția de detectare a funcționării uscate. 1. Îndepărtați orice BIM 2. Porniți pompa 3. Asigurați-vă că pompa nu este în modul funcționare oprită. 4. Asigurați-vă că pompa nu este tranzitată de fluid. 5. Dezactivați blocarea tastelor. 6.Apăsați toate tastele pentru 10s (10s corespund la 8 – 9 rotații ale paletei) • O scurtă întrerupere poate duce la blocarea tastelor sau la comutarea pompei în modul funcționare oprită. 7.Dacă paleta se rotește cu două segmente detectarea funcțio nării uscate este dezactivată, dacă paleta se rotește cu un segment detectarea funcționării uscate este activată. 8. Modulele sau semnalele externe pot fi reconectate. Dacă pompa funcționează în regim uscat având dezactivată funcția de detectare a funcționării uscate, nu va semnala nici o eroare și pot avea loc defecțiuni. Funcția de detectare a funcționării uscate poate fi dezactivată doar dacă pompa funcționează fără erori și nu este conectat nici un BIM (Biral Interface Module). 90 | română Pumpe steht. Störung (Problemfälle) Pumpe läuft normal Pumpe steht. Störung (Problemfälle) Drehung drehend Muster normal Farbe grün Pumpe normal Pompa Pumpe läuft läuft funcţionează normal Pumpe Extern OFF Pumpe von Taste oder App Steuer, START/STOP PWM, Hoval. Pumpe gestoppt drehend ormal Pumpe Extern Extern OFF OFF Pumpe Pumpe START/STOP von Taste oder App Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) Pumpe Pumpe START/STOP START/STOP von von Taste Taste oder oder App App ModulA-...D mit BIM A2 Siganlmodul Pumpe steht. Störung (Problemfälle) Doppelpumpe (Pumpe aktiv) Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) Pompă Pumpe steht.defectă Störung (Problemfälle) ehung drehend ster normal 12.5 6.3 3.2 1.6 0.8 be grün N10 0.4 ModulA-...D mit BIM A2 Siganlmodul Allgemeintoleranzen ISO 2768-mK N9 N8 N7 N6 N5 0.5 bis 6 über 6 bis 30 über 30 bis 120 über 120 bis 400 Doppelpumpe ± 0.2 (Pumpe±aktiv) 0.3 ± 0.5 ± 0.1 Doppelpumpe (Pumpe passiv) ... ModulA-...D mit BIM BIM A2 A2 Siganlmodul Siganlmodul ModulA-...D mit Pumpe läuft. Störung (Problemfälle) ehung stehend ster blitzend be grün Pumpe steht. Störung (Problemfälle) Pumpe läuft. Störung (Problemfälle) Pumpe Pumpe steht. steht. Störung Störung (Problemfälle) (Problemfälle) Pumpe Störung Afişaj Stare Pumpe steht. steht. Mişcare Störung (Problemfälle) (Problemfälle) Drehung stehend stehend Drehung normal rotaţie Pompa funcţionează în mod normal Muster Muster blinkend blinkend Farbe Steuer, PWM, Hoval. Pumpe ge Pumpe läuft. Störung (Problemfälle) ModulA-D ... (Pompă Farbe rot rot activă) Steuermodul BIM B2: Doppelpu Drehung drehend Muster normal normal oprită Pompa OPRITĂ de la tastă sau APP Farbe rot vezi secţiunea 7.6 (Pompă oprită) Steuer, Steuer, PWM, PWM, Hoval. Hoval. Pumpe Pumpe ge ge Pumpe läuft. läuft. Störung Störung (Problemfälle) (Problemfälle) Pumpe Drehung Drehung stehend stehend Muster blitzend verde Muster blitzend Farbe grün grün Farbe Drehung stehend Muster normal Drehung drehend verde Farbe grün Muster blitzend Farbe grün Drehung Drehung stehend stehend Muster Muster normal normal Farbe Farbe grün grün Drehung Drehung drehend stehend Muster Muster normal blitzend Drehung stehend roşu Farbe grün Farbe grün Muster blinkend Farbe rot Doppelpumpe (Pumpe passiv) Betriebskontrolle ex Datum Visum lA l Impeller ehung drehend ster normal be grün 961568_00 Betriebskontrolle Ersetzt durch: Drehung drehend oprită Drehung drehend Muster normal normal OPRIRE externă Muster Farbe rot rot Farbe ModulA-D ... (Pompă pasivă) inter mitent rotaţie Pompa controlată extern inter mitent oprită Alarmă Freigabe ... (Mesaj de funcţionare: PORNIT) Drehung stehend ... ... blitzend (MesajMuster de avarie: PORNIT) Farbe grün ... Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) Drehung drehend Muster blitzend Biral Impeller Drehung stehend Muster blitzend Änd.Index Datum Farbe grün ts Änd.Index Datum Änd.Index Datum Biral Impeller ... Datum Pos Visum Material elungsart Zyklus Biral AG CH-3110 Münsingen Visum Visum Ersatz für: geprüft 20.03.2009 ts Freigabe 20.03.2009 ts PDM_Nr TD-0011003 Zeichnungsnummer 961204 Änd.Index Datum Änd.Index 00 Ersetzt durch: Ersetzt durch: Biral Biral AG AG CH-3110 Münsingen Münsingen CH-3110 ... Massstab gezeichnet 07.01.2009 ts 1:1 Ersetzt durch: Biral AG Biral Biral Impeller Impeller CH-3110 Münsingen Modell/Art.Nr Bemerkung Ersetzt durch: A652 ab 2009 Visum Biral AG CH-3110 Münsingen Drehung ... ModulA Muster ... ModulA Farbe ... Drehung ... Muster ... Farbe ... Gegenstand Ersetzt durch: Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) 09.04.2013 ts 961568_00 2 Comutatorul OPRIRE externă PDM_Nr TD-0021556 OPRIT Vezi secţiunea 5.5.2 Zeichnungsnummer Änd.Index Biral AG 00 961568 CH-3110 Münsingen 961568_00 Comutatorul 3 Limitarea puterii OPRITĂ 961568_00 OPRIT Vezi secţiunea 5.5.3 Visum ModulA ModulA ts ... ... Änd.Index Farbe grünDatum ehung stehend ster blitzend be grün x Steuermodul BIM B2: Doppelpu ... drehend (mesajDrehung de funcţionare: Steuermodul BIM BIM B2: B2: Doppelpu Doppelpu Muster blitzend Steuermodul OPRIT)Farbe (Mesaj de avarie: grün PORNIT) ... normalSteuer,rotaţie Avertis- PWM, Hoval. Pumpe gestoppt ment Curba caracteristică setată la 3 LED-ul luminează verde Ersatz für: 961204_00 Steuermodul Steuermodul BIM BIM B2: B2: Doppelpu Doppelpu Steuer, PWM, Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Drehung stehend stehend Drehung Muster blitzend blitzend Muster Farbe grün grün proporţională Farbe Comutatorul 1 MesajMassstab de avarie gezeichnet 12.02.2013 Betriebskontrolle Vezi secţiunea 5.5.1 OPRIT Betriebskontrolle 1:1 geprüft 09.04.2013 Steuermodul BIM B2: Doppelpu Steuermodul BIM B2: Doppelpu Zusatzmodule Presiune LED-ul luminează galben 3 Steuer, Steuer, PWM, PWM, Hoval. Hoval. Pumpe Pumpe au au flashing 7.10Setarea din fabrică a pompei Doppelpumpe (Pumpe passiv) ehung stehend ster normal be grün Steuer, PWM, Hoval. Pumpe au Steuer, PWM, Hoval. Pumpe ge Zusatzmodule Zusatzmodule Drehung stehend Drehung drehend Muster blinkend Musterrot normal Farbe Farbe rot Drehung drehend drehend Drehung verde Muster Muster normal normal Farbe Farbe grün grün Drehung stehend Drehung stehend Muster blitzend Drehung stehend verde Muster normal Farbe Mustergrün blitzend Farbe Farbe grün grün Drehung drehend roşu Drehung stehend Muster normal Drehung ... Muster blitzend Farbe Mustergrün ...drehend Drehung Farbe grün Farbe ... Muster normal Farbe rot Drehung Drehung drehend drehend Muster Muster normal normal Farbe Farbe grün grün Drehung stehend Muster blitzend Drehung ... Farbe Mustergrün ... Farbe ... Doppelpumpe (Pumpe passiv) ... Zusatzmodule Drehung drehend Drehung stehend Muster normal Drehung drehend Muster blitzend Farbe grün Muster blitzend Culoare Farbe Farbe grün grün über 400 bis 1000 ± 0.8 Doppelpumpe Doppelpumpe (Pumpe (Pumpe aktiv) aktiv) Steuer, PWM, Hoval. Pumpe au Drehung stehend Muster blinkend Farbe rot Pumpe steht. Störung (Problemfälle) Zusatzmodule 7.9 Rotorul Biral Pumpe läuft normal indică starea pompei: Steuer, PWM, OFF Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Pumpe Extern stehend nkend Zusatzmodule Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 12.02.2013 ts ModulA 1:1 Biral Impeller Biral AG CH-3110 Münsingen geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0021556 Zeichnungsnummer 961568 Änd.Index 00 română | 91 8. Prezentarea defecţiunilor și Checklist Avertizare Înaintea începerii lucrărilor de depanare, scoateţi obligatoriu pompa din funcţiune, deconectaţi toţi polii de la reţea şi asiguraţi-o împotriva repornirii. Se efectuează numai de către personalul specializat. Componente expuse sub tensiune! Zusatzmodule Pericol de arsuri cauzate de fluidul eliberat Steuer, PWM, Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Drehung drehend Muster blitzend Farbe grün Drehung stehend Muster blinkend Farbe rot Pumpe steht. Störung (Problemfälle) Zusatzmodule Pericol de arsuri cauzate de suprafeţele fierbinţi Steuer, PWM, Hoval. Pumpe gestoppt Pumpe läuft normal Drehung drehend Muster normal Farbe rot Drehung stehend Muster blitzend Drehung drehend Farbe grün Muster normal Farbe grün Pumpe steht. Störung (Problemfälle) Drehung drehend Muster blitzend Drehung stehend Pumpe läuft. Störung (Problemfälle) Steuer, PWM, Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Drehung drehend Muster blitzend Farbe grün Drehung stehend Muster blinkend Farbe rot Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) Pumpe Extern OFF Steuer, PWM, Hoval. Pumpe gestoppt Farbe grün Muster normal Dacă nu este disponibil niciMuster unblitzend Remote Adapter, parcurgeți lista de sus în jos pas cu pas. Farbe rot Farbe grün Dacă este disponibil un Remote Adapter, cauza erorii este afișată direct în aplicația Remote. Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) Pumpe START/STOP von Taste oder App Prezentarea defecțiunilor 1 Paleta Biral (LED indicator) nu ... luminează 2 Paleta ndicator) se ModulA-...DBiral mit BIM(LED A2 Siganlmodul ... rotește culoarea roșie (Atenție. Doppelpumpe (Pumpe aktiv) Pompa se rotește) Drehung stehend Muster blitzend Farbe grün Drehung drehend Drehung stehend Muster blitzend Drehung stehend Farbe grün Muster normal Farbe grün Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) Cauza Remediu Lipsă tensiune de alimentare Verificați comutatorul de rețea și siguranțele Verificați ștecherul și cablul de alimentare cu tensiune Eroare de comunicarea a senzorului (*) Ce trebuie făcut 1. Verificați mufa senzorului ... 2. Înlocuiți kitul senzorulu Vezi instrucțiuni de utilzare Kit senzor ModulA Drehung ... Muster ... Farbe ... Drehung ... Muster ... Drehung Farbe ... drehend Muster normal Farbe grün Drehung drehend Muster blitzend Farbe grün Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) Drehung stehend Muster blitzend Farbe grün Drehung ... Muster ... Farbe ... Diagnosticare fără adaptor fără fir dacă nu 3 Paleta Biral (LED indicator) pâlpâie Prima măsură, Pumpe steht. Störung (Problemfälle) Zusatzmodule ... Doppelpumpe (Pumpe 1.Verificare dacă pompa este setată pe modul culoarea roșiepassiv) (Alarmă. Pompa nu este disponibil un adaptor Steuer, PWM, Hoval. Pumpe auf Min, Normaler Betrieb (cs) oder Max. Pumpe steht. Störung (Problemfälle) Drehung stehend de operare OPRIT (consultați instrucțiunile de fără fir. se rotește) Muster blitzend Änd.Index Datum Visum Drehung drehend Drehung stehend Drehung drehend grün folosință Secțiunea 7.7) Ersetzt durch: Ersatz für: Farbe Muster blitzend Muster blinkend Muster normal Farbe grün Biral (LED indicator) începe să Farbe rot Farbe grün 2. Dacă da , paleta Massstab gezeichnet 12.02.2013 ts ModulA se rotească roșu (vezi «Eroare de comunicarea a 09.04.2013 ts geprüft 1:1 Biral Impeller senzorului»), în caz contrar eroarea este în altă 09.04.2013 ts Freigabe Steuer, PWM, Hoval. Pumpe gestoppt Pumpe läuft. Störung (Problemfälle) PDM_Nr TD-0021556 parte. Drehung stehend Muster blitzend Farbe grün Biral AG Betriebskontrolle CH-3110 Münsingen Drehung drehend Zeichnungsnummer Änd.Index 961568 Muster normal Farbe rot (74) 00 Supratensiune (*) Subtensiune Drehung stehend Muster blitzend Datum Visum 3. VerificațiÄnd.Index sursa de tensiune Farbe grün 4. VerificațiModulA sursa de tensiune 961568_00 Mod de operare Turbionare Drehung stehend Muster blitzend ... Drehung drehend Muster normal Farbe grün Ersatz für: Massstab gezeichnet 12.02.2013 ts 1:1 Farbe grün Ce trebuie făcut 6. Verificați dacă supapa de sens prezintă defecțiuni. În funcție de necesități înlocuiți supapa de sens. 7. Verificați dacă supapa de sens este montată la Drehung ... locul potrivit în ...instalație. Muster Farbe ... ... Drehung stehend Muster blitzend Farbe grün Ersetzt durch: Biralfără Impeller 09.04.2013 ts Freigabe Diagnosticare adaptor fără fir Drehung drehend PDM_Nr TD-0021556 Muster blitzend de la comutatorul principal. 5.Deconectați pompa Farbe grün Zeichnungsnummer Änd.In AG Dacă paleta Biral (LEDBiral indicator) pâlpâie roșu, 00 961568 CH-3110 Münsingen pompa se află în mod de funcționare «Turbionare», în caz contrar eroarea este în altă parte. Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) Drehung stehend Muster normal Farbe grün Drehung ... Muster ... Farbe ... Drehung ... Muster ... Farbe ... geprüft 09.04.2013 ts 92 | română Prezentarea defecțiunilor Cauza Remediu Diagnosticare fără adaptor fără fir 3 Paleta indicator) pâlpâie Motor blocatZusatzmodule Pumpe steht.Biral Störung(LED (Problemfälle) 8.Deconectați și reconectați pompa de la comutatorul culoarea roșie (Alarmă. Pompa nu Steuer, PWM, Hoval. Pumpe auf Min, principal. Normaler BetriebLa (cs) 3 oder Max. Pumpe steht. Störung (Problemfälle) secunde după reconectare au loc 3 se rotește) Drehung drehend Drehung stehend Drehung drehend încercări de deblocare. Releul de protecție devine Muster blitzend Muster blinkend Muster normal activ și paleta Biral (LED incdicator) pâlpâie roșu Farbe grün Farbe rot Farbe grün după 20 secunde, în caz contrar eroarea este în altă parte. Steuer, PWM, Hoval. Pumpe gestoppt Pumpe läuft. Störung (Problemfälle) Drehung stehend Muster blitzend Farbe grün Drehung drehend Muster normal Farbe rot Drehung stehend Muster normal Farbe grün Drehung stehend Ce trebuie făcut Muster blitzend grün 9.DemontațiFarbe capul pompei (consultați instrucțiunile de folosință Motor ModulA) 10.Dacă găsiți corpuri străine îndepărtați-le. Steuermodul BIM B2: Doppelpumpe (Pumpe aktiv) 11.Verificați elicea, iar dacă prezintă defecte înlocuiți Drehung drehend blitzend motorul. Muster Farbe grün 12.Dacă elicea este în regulă, montați capul pompei la loc. (consultați instrucțiunile de folosință Motor Steuermodul BIM B2: Doppelpumpe (Pumpe passiv) ModulA) Funcționare în regim uscat ... Drehung drehend Muster normal Farbe grün ... Drehung stehend Muster blitzend Farbe grün Änd.Index Datum Visum Ersetzt durch: Drehung stehend Muster blitzend Diagnosticare fără adaptor fără fir Farbe grün 13.Setați nivelul 1 al turatției și permiteți funcționare minim 1 minut. 13.1. D acă paleta Biral comută pe roșu eroarea e Drehungde ... altceva. cauzată Muster ... Farbe ... 13.2. D acă paleta Biral rămâne verde, treceți la punctul următor. 14.Setați nivelul 6 al turatției și permiteți funcționare minim 1 minut. Drehung ... 14.1. D acă în primul minut de funcționare apare Muster ... ... vreoFarbe eroare, înseamnă că mai există încă o defecțiune. 14.2. D acă paleta Biral comută pe roșu după 1 minut, există cu certitudine o alarmă de funcționare în regim uscat. Ersatz für: Există diferite cauze pentru o alarmă de funcționare în Massstab regm gezeichnet uscat:12.02.2013 ts 09.04.2013 ts geprüft – A1:1 er în Freigabe sistem09.04.2013 (funcționare uscată propriu-zisă – Biral Impeller ts instalația nu este plină sau aerisită) PDM_Nr TD-0021556 Zeichnungsnummer Änd.Index – Presiunea de admisie mai mare decât presiunea de Biral AG 00 961568 CH-3110 Münsingen evacuare. – Alarmă datorată unei erori de măsurare ( senzor astupat, gaura de montaj a senzorului astupată, carcasa senzorului montată greșit, senzor deteriorat) ModulA Ce trebuie făcut 15.Verificați dacă instalația are suficientă apă. 16.Verificați dacă există bule de aer în sistem (zgomote). 17.Apăsați orice tastă pentru a îndepărta eroarea. 18.Setați funcția de control nivelul 6 al turației și permiteți funcționare minim 1 minut. Dacă este posbil cu obturatorl deschis și închis. 19.Dacă paleta Biral din nou comută pe roșu după 1 minut, există cu certitudine o alarmă de funcțio nare în regim uscat. 20.Plecând de la premiza că instalația este umplută și aerisită corespunzător, se poate întâmpa ca alarma de funcționare în regim usact să fie o Ala rmă falsă generată de o valoare de măsurare greșită. 21.Înlocuiți senzorul sau contactați service-ul Biral. Defecțiune internă (*) – (10) eroare de comunicare – Eroare hardware – Eroare de accesare a memoriei – Eroare a curentului de anclanșare – Eroare RTC 22. Înlocuiți electronica ModulA sau contactați service-ul Biral pentru suport. Verificați daca pompa funcționează în regim «Turbionare» (consultați secțiunea «Turbionare») sau dacă este doar tranzitată de fluid. en română | 93 9. Senzor În timpul lucrărilor de întreţinere sau la înlocuirea senzorului, capacul de etanşare trebuie montat în mod corespunzător pe carcasa senzorului. Avertizare Înainte de a înlocui senzorul, asiguraţi-vă că pompa este oprită şi sistemul este depresurizat. X 5Nm 961612_00 X Nasul trebuie să fie îndreptat în jos. Şurubul de fixare a suportului trebuie strâns la 5 Nm. 5Nm II I Änd.Index Datum Visum Ersetzt durch: Massstab gezeichnet 08.04.2013 ts ModulA Montage Sensor BA Biral AG CH-3110 Münsingen Ersatz für: Massstab gezeichnet 08.04.2013 ts 1:3 geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0022120 Zeichnungsnummer 961612 Ersatz für: Änd.Index 00 1:3 geprüft 09.04.2013 ts Freigabe 09.04.2013 ts PDM_Nr TD-0022120 Zeichnungsnummer 961612 Änd.Index 00 94 | română 10. Accesorii/Variante 10.1 Telecomanda Biral Biral Remote facilitează configurarea şi analiza ModulA. Comunicarea fără fir se realizează printr-o conexiune Wifi cu ModulA, care este echipat cu o interfaţă pentru adaptorul pentru telecomandă. Telecomanda Biral APP Telecomanda Biral APP se poate descărca gratuit de pe iTunes şi Play-Store. Aceasta funcţionează numai cu adaptorul pentru telecomandă aferent (Hardware). Setări şi informaţii (extras) Info Tipul pompei · Versiune software · Număr de serie · Data fabricaţiei · Perioadă Stare Debitul · [m³ / h] Înălţimea de pompare · [m] Temp. agent · [°C] Turaţie · [1 / min] Tipul de automatizare · Presiune proporţională (pp) · Presiune constantă (cp) · Turaţie constantă (cs) Valoare nominală · pp, cp [m] · cs [%] Ore · [h] Energie electrică · [kWh] Configuraţie Regim de funcţionare · Pornire funcţionare · Oprire funcţionare · Turaţie minimă · Turaţie maximă Tipul de automatizare Alarmă actuală Alarmă actuală · Defecţiune comunicare · Defecţiune internă · Supratensiune · Subtensiune · Solicitare forţată · Funcţionare pe uscat · Pompă blocată · Presiune proporţională Avertizare actuală · Defecţiune senzor · Presiune constantă · Defecţiune internă · Turaţie constantă Valoare nominală · Setare · curbă caracteristică Limitarea puterii Jurnal de alarme 1 Jurnal de alarme 2 Jurnal avertizări 1 · Setare limitare debit Jurnal avertizări 2 25% … 90% din Q_max Număr pompă · Definiţie · Număr pompă pentru identificare BUS Blocare taste · Blocare taste · Deblocare taste Perioadă · Setare internă Durată de pompare Adaptorul pentru telecomandă Adaptorul pentru telecomandă este echipat cu Wifi şi este necesar pentru comunicarea fără fir între telefonul smartphone şi pompă. Remote Adapter APP română | 95 10.2 M odulul de semnalizare BIM A2 (pentru pompe autoreglabile) –– Mesaj de funcţionare/pregătire –– Turaţie minimă externă –– Funcţia pompelor duble Observaţie: Nu este posibil în combinaţie cu modulul de comandă Schemă de conectare 10, 13 Turaţie minimă externă cu contact normal deschis 61, 64Mesaj de funcţionare sau de pregătire (comutabil) drept contact normal deschis: închide la mesajul de funcţionare/ pregătire 61, 62Mesaj de funcţionare sau de pregătire (comutabil) drept contact normal închis: deschide la mesajul de funcţionare/ pregătire 91, 92 Funcţia pompelor duble 961561_00 91 92 13 10 61 62 64 max. 250V AC 2A min. 5V DC 20 mA 10.3 Modulul de comandă BIM B2 (pentru pompe controlate) –– Presetare externă a turaţiei 0–10 V/0–20 mA –– Interfaţă PWM/Multitherm. –– Funcţia pompelor duble Änd.Index Datum Observaţie: Nu este posibil în combinaţie cu modululII de I semnalizare Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 25.01.2013 ts ModulA 1:1 geprüft 12.02.2013 ts Anschlusschema Schemă de conectare Freigabe 12.02.2013 ts BIM A2 PDM_Nr TD-0021438 81, 82 Multitherm/PWM Interfaţă pentru presetarea externă a turaţiei 961562_00 Zeichnungsnummer Änd.In Biral AG 71, 72Intrare analogică 0…10 V sau 0…20 mA pentru presetar- CH-3110 81Münsingen 82 71 72 91 92 00 961561 ea externă a turaţiei 91, 92 Funcţia pompelor duble 10.4 Varianta pentru încălzire şi apă caldă menajeră II I Änd.Index Datum Visum Ersetzt durch: Ersatz für: Massstab gezeichnet 25.01.2013 ts ModulA Anschlusschema BIM B2 Biral AG CH-3110 Münsingen 1:1 geprüft 12.02.2013 ts Freigabe 12.02.2013 ts PDM_Nr TD-0021440 Zeichnungsnummer 961562 Änd.In 00 96 | română 11. Date tehnice Tensiune de alimentare 1×230 V ±10%, 50/60 Hz, PE Protecţia motorului Nu este necesară o protecţie externă a motorului Clasa de protecţie IP 44 (EN 60529) Clasa bobinei Clasa de izolare F Clasa de temperatură TF 110 (EN 60335-2-51) Temperatura fluidului –10 °C până la +110 °C (ModulA GREEN) Temperatura ambiantă max. 40 °C în timpul transportului: –40 °C până la +70 °C Presiune maximă de funcţionare Presiunea maximă de funcţionare este indicate pe plăcuţa de timbru: PN 6: 6bar PN 10: 10bar PN 16: 16bar Zgomot Nivelul zgomotului este sub 43 dB(A) Curent de scurgere Filtrul de reţea al pompei cauzează un curent de scurgere la masă (împământare) <3,5 mA în timpul funcţionării. Consum de curent cu pompa oprită <3W Factor de putere cos-phi ModulA dispune de un filtru de corecţie a factorului de putere integrat (PFC). Acesta asigură că factorul de putere este întotdeauna între 0,98 şi 0,99 şi, prin urmare, este menţinut foarte aproape de valoarea ideală 1. CEM (Compatibilitate electromagnetică) EN 55014-1:2006, EN 55014-2:1997, EN 61000-3-3:2008 şi EN 61000-3-2:2006 12. Casarea Această pompă de circulaţie modulA a fost proiectată având în vedere durabilitatea. Aceasta include prevenirea producerii de deşeuri şi reciclarea materialelor. Acest produs, precum şi piesele acestuia trebuie casate conform reglementărilor locale. română | 97 13. Lista pieselor de schimb 6 3 1 7 4 5 8 2 961872_00 Număr de articol Biral ModulA… Pos. 1 Parte electro nică plus capac neutral Pos. 2 Motor cu O-Ring ModulA 32F-12 22 0300 0150 22 0404 0150 ModulA 40-8 22 0300 1650 22 0404 0250 ModulA 40-10 22 0300 0250 22 0404 0250 ModulA 40-12 22 0300 0350 22 0404 0350 ModulA 40-18 22 0300 0450 22 0404 0350 ModulA 50-6 22 0300 0550 22 0404 0450 ModulA 50-8 22 0300 1750 22 0404 0450 ModulA 50-12 22 0300 0650 22 0404 0550 ModulA 50-18 22 0300 0750 22 0404 0750 ModulA 65-8 22 0300 0850 22 0404 0850 ModulA 65-12 22 0300 0950 22 0404 0850 ModulA 65-15 22 0300 1050 22 0404 1050 ModulA 80-8 22 0300 1150 22 0404 1150 ModulA 80-12 22 0300 1350 22 0404 1150 ModulA 100-12 22 0300 1550 22 0404 1150 1 Stück II I Pos Gegenstand Änd.Index Datum Visum Material Ersetzt durch: Pos. 3 Pos. 4 ModulA GREEN BG3, BG4 Kit senzor Ersatzteilliste Capac fără șuruburi Biral AG CH-3110 Münsingen Modell/Art.Nr Bemerkung Ersatz für: Pos. 5 Stecher 1:3.5 (L, N, PE) Massstab gezeichnet 17.12.2014 nma geprüft Freigabe PDM_Nr TD-0028878 Zeichnungsnummer 961872 Änd.Index 00 Biral RED 22 0033 0299 22 0301 0150 Biral GREEN 22 0033 0399 Biral BLUE 22 0033 0499 05 9123 9700 98 | română 6 3 1 7 961872_00 2 Număr de articol Biral ModulA… ModulA 32F-12 Pos. 6 Set de garnituri Pos. 7 O-Ring 1 Stück II I Pos Gegenstand Änd.Index Datum Visum ModulA 40-12 00 1503 4600 00 1503 4300 ModulA 50-6 ModulA 50-12 00 1503 4400 05 2544 8499 ModulA 50-18 ModulA 65-8 270 ModulA 65-8 340 ModulA 65-12 00 1503 4500 ModulA 65-15 ModulA 80-8 ModulA 80-12 ModulA 100-12 00 1503 0500 00 1503 0600 22 0069 0100 Modell/Art.Nr Bemerkung Ersetzt durch: Biral AG CH-3110 Münsingen ModulA 40-18 ModulA 50-8 Material Pos. 8 ModulA GREEN BG3, BG4 Kit pentru Ersatzteilliste montare pe perete ModulA 40-8 ModulA 40-10 4 5 8 Ersatz für: Massstab gezeichnet 17.12.2014 nma 1:3.5 geprüft Freigabe PDM_Nr TD-0028878 Zeichnungsnummer 961872 Änd.Index 00 Biral GmbH Freiherr-vom-Stein-Weg 15 D-72108 Rottenburg am Neckar T +49 7472 16 33 0 F +49 7472 16 34 0 E-Mail: [email protected] www.biral.de Biral Pompen B.V Printerweg 13 3821 AP Postbus 2650 3800 GE NL-Amersfoort T +31 33 455 94 44 E-Mail: [email protected] www.biral.nl More than pumps 08 0440.2011_03 Nr. 04/15 Biral AG Südstrasse 10 CH-3110 Münsingen T +41 31 720 90 00 F +41 31 720 94 42 E-Mail: [email protected] www.biral.ch www.biralcampus.ch