Download Operating Instructions Type 1094 EV
Transcript
Type 1094 EV Technical Data 6.5.1. Frequency inputs / Gasoline pulses 5V The volumetric flow of the delivered gasoline is measured by the piston meter, converted into a frequency-proportional clock signal by the gasoline pump computer and switched to the frequency input of the controller (Fig. 4: ). In the controller this clock signal is processed as the actual value of the volumetric flow of the gasoline. High-level pulse:3.4 V – 26 V Low-level pulse: 0 V – +0,9 V Input resistance: > 10 kΩ Max. input current: 5 mA Jumper(1 C03 / C05 Input terminals for gasoline pulse Input to the controller GND Fig. 4: Frequency input of the controller Type 1094 EV Min. pulse duration: 400 µs Measurement rate: 1 measurement/0.75 s Resolution: 1 Hz Measuring range: 0 ... 51 l/min (1The Jumper C0 (C03 for side 1 and C05 for side 2) can be used to switch the input from “open emitter” to “open collector”. Pulse rate:Can be adjusted via manual control unit from 31 – 200 pulses/liter English 15