Download 10640 Discharge point / Operating Instructions

Transcript
H. Lüdi + Co. AG
Postfach
Moosäckerstrasse 86
CH- 8105 Regensdorf
Tel.
Fax.
home
e-mail
+41 44 843 30 50
+41 44 843 30 90
www.hlag.ch
[email protected]
10640 Discharge point / Operating Instructions
40
G 1/4"
Eingang
52
10
Ø1
1
6,5
20
160
Ø
30
G 1/4"
60
Ausgang
Construction
Discharge point pressure-regulating unit with inlet shut-off valve10), pressure
regulator(20) and manometer (30) for outlet pressure.
Max. supply pressure P1max. = 40bar
I.
1.
2.
3.
4.
5.
Start-up of discharge point
Close shut-off valve (10) at 9 o'clock position. Connect user with suitable
connections for corresponding gas and pressure range.
Relieve regulator by turning regulator setting knob (20) in counter-clockwise
direction.
Slowly open shut-off valve to 12 o'clock position. Pressure sets in on regulator.
Adjust initial pressure P2 to required value by turning pressure-regulating knob (20)
in clockwise direction. Pressure is indicated on the manometer (30).
Check that the system is leak-tight all the way to the user.
II.
Short-term shut-off of discharge point
Close shut-off valve (10) by turning in counter-clockwise direction to 9 o'clock
position.
III.
1.
Shut-down of discharge point
Close shut-off valve (10) by turning in counter-clockwise direction to 9 o'clock
position.
Let off initial pressure through user until indicator of manometer (30) stands at "0".
Relieve pressure regulator by turning setting knob (20) in counter-clockwise
direction as far as it will go.
2.
3.
IV.
Safety
Observe general guidelines for handling gases
Protect discharge point from mechanical or chemical damage
Never use oils or greases
Repairs must be made only with original parts by the manufacturer
04.07 / Hj
e10640 Discharge point Operating Instructions
Seite 1 / 1