USER GUIDE
Espace range alarm system
www.daitem.com
User guide
You have just bought
a DAITEM security system,
designed to cover all your
protection needs.
We would like to thank you
for your confidence.
IMPORTANT ADVICE
With TwinBand®‚
and TwinPower®, you will
benefit from the flexibility
of a totally wire-free system
based on dual band radio
technology
and a doubly secure power
supply.
SOME PRECAUTIONS TO FOLLOW
Your security system is simple to use. We advise you to switch it on (arm) every
time you leave your home.
Do not leave your remote control in view.
Keep a back-up remote control in a secret place.
If one of the devices in your system is lost, stolen or sabotaged, call your installer
right away.
Keep the access codes to your remote control keypads secret.
When you are at home
Do not leave entrances (doors and windows) open for no reason.
Switch your system to partial protection mode (Part Set) to protect unoccupied
rooms.
When you leave home
Close all the protected doors and windows.
Switch on (arm) your security system.
If necessary, check for any indications of faults or doors and windows left open.
When you're going to be away for a while
Check that all doors and windows are closed.
Check your security system is operating properly by actually testing it.
Switch on (arm) your system
IMPORTANT REMARK
The installer can access your system remotely in order to perform maintenance
or uploading & downloading operations via a telephone and computer according to the conditions outlined in this guide. It is up to your installer to define
with you the specific contractual conditions for accessing your system.
WE WOULD APPRECIATE YOUR SUGGESTIONS
If you have any comments about how we might improve our guides and our
products, we would be grateful if you could send them in writing to:
Daitem - Service consommateur
rue du Pré de l’Orme - F-38926 CROLLES cedex
LÉGENDE
☺ Correct programming is confirmed
by a long beep or the green LED
indicator lamp lighting up.
important points
recommendations
press once
press and hold
Incorrect programming is
indicated by 3 beeps or the red
LED indicator lamp flashing.
2
Daitem security system
CONTENTS
Your DAITEM security system . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operating your security system . . . . . . . . . . . . . . . . . . . . . . . . . . 5
The information keypads provide information
about device status and messages from the control panel . . . . . 8
Modifying your access codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Restricting access to control function . . . . . . . . . . . . . . . . . . . . 10
Regularly testing your system: Test mode . . . . . . . . . . . . . . . . . 12
Performing a real test on your security system . . . . . . . . . . . . . 13
Defining access for remote upload/download
service computer operations . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Your telephone dialler warns your designated
correspondents or keyholders . . . . . . . . . . . . . . . . . . . . . . . . . . 15
The control panel indicates alarms and warns
your correspondents or keyholders . . . . . . . . . . . . . . . . . . . . . . 18
The control panel indicates faults and warns
your correspondents or keyholders . . . . . . . . . . . . . . . . . . . . . . 19
Checking the events log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Remotely operating your security system . . . . . . . . . . . . . . . . . 21
Additional keypad functions . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Product destination:
The equipment sold by DAITEM is designed to ensure better protection and more comfortable conditions in
homes and a number of professional premises or to ensure the protection and well-being of individuals
according to the technical and environmental limits described in the documents provided by DAITEM and
recommended by retailers.
CE marking and regulations:
The products sold by DAITEM comply with the essential requirements of applicable European directives. CE
marking provides proof of the products’ compliance with these directives and with the standards defining the
technical specifications to be followed.
Communication network (unavailability):
DAITEM reminds users that its systems operate via telecommunication networks (public switched telephone,
radio, GSM networks, etc.), the availability of which cannot be 100% guaranteed.
DAITEM draws the user’s attention to the fact that should the network being used become unavailable this
may have consequences on the availability of its own systems.
Should this situation arise, independent of the will of DAITEM, neither DAITEM nor the manufacturer can be
held liable for any damaging consequences that may ensue.
Ask your retailer for the guarantee and after-sales service application conditions binding
it to the manufacturer.
3
User guide
YOUR DAITEM SECURITY SYSTEM
detect
deter
remote switched
relay outputs
receiver
motion
detectors
smoke
detector
external strobe siren
universal
transmitter
))
))
))
))
)
)
)
)
)
))
))
))
supervise
)
))
) ) )))
) )))
)))
)
multicontact
detectors
)
remote
PC service
relay
remote control units
))
) ) )))
)
))
))
)
) )))
)
) ))
radio relay
(repeater transceiver)
uploading /
downloading
software
) ) )))
control panelsiren-telephone dialler
)
)
))
)
))
)
)
remote keypads
control
and information
remote keypads
voice keypad
with
tag reader
listen-in
and speak-out
(talk-back)
module
user control
4
hardwired
control interface
remote
keypad
Daitem security system
OPERATING YOUR SECURITY SYSTEM
group 2
The control panel has up to 8* intrusion protection groups that can be operated
separately or together.
Example: control panel with 4 active
* The number of groups depends
on the control panel model.
protection groups.
group 3
group 4
group 1
Switching your system ON or OFF
• Remote control unit:
press ON or OFF
• Control keypads
or interface:
OFF: all groups switched off (disarmed)
master code
• Keypad
with tag reader:
“beep, OFF”
OFF
or
ON
"beep,
ARMED”
Partiel 2
Etat
Système
OFF
or
ON
ON: all groups switched on (armed)
tag presented within 3 sec. after pressing
Switching your system ON for PARTIAL (part set) operation
• Remote control unit:
press on Partial 1 or Partial 2
• Control keypads
or interface:
Partial 1: group 1 only armed
master code
• Keypad
with tag reader:
Partial 1
or
Partial 2
“beep, armed,
partial 1”
“beep, armed,
partial 2”
Partiel 2
Partial 1
or
Partial 2
Etat
Système
Partial 2: group 2 only armed
tag presented within 3 sec. after pressing
ARMED PRESENCE (stay) mode
The control panel has a protection mode that makes it possible to arm group 1
only and cause the system to generate a discrete response in case of intrusion:
Armed Presence mode or stay mode.
• Control keypads
or interface:
master code
presence
mode
“beep, armed,
presence
mode”
Armed Presence mode: group 1 only is armed
• Keypad
with tag reader:
Partiel 2
presence
mode
Etat
Système
tag presented within 3 sec. after pressing
There is no exit or entry time delay in presence mode.
group OFF
group armed
5
User guide
OPERATING YOUR SECURITY SYSTEM (cont.)
Switching SEVERAL GROUPS ON and OFF*
• Control keypads
or interface:
ON or OFF
codice
principale
1 : group 1
5 : group 5
2 : group 2
6 : group 6
3 : group 3
7 : group 7
4 : group 4
8 : group 8
• Keypad
with tag reader:
* The radio keypads can only control
groups 1 to 4. To control groups 5 to 8,
use a hardwired control interface
remote keypad or a control panel
keypad.
**
“beep, armed,
group ?”
Partiel 2
ON or OFF
1 : group 1
5 : group 5
2 : group 2
6 : group 6
3 : group 3
7 : group 7
4 : group 4
8 : group 8
Etat
Système
**
tag presented
within 3 sec. after pressing
Examples using a keypad:
• Arming group 3
** The number of groups depends
on the control panel model.
“beep, armed,
group 3”
3
master code
ON
Group 3 armed
• Arming group 1 + group 2
1
“beep, armed,
group 1-2”
2
master code
ON
Groups 1 + 2 armed
Examples using a keypad with tag reader:
• Switching off group 2
2
“beep, OFF,
group 2”
Partiel 2
Etat
Système
OFF
Group 2 OFF
• Switching off group 1 + group 2
1
“beep, OFF,
group 1 - 2”
2
Partiel 2
OFF
group OFF
Etat
Système
group armed
Groups 1 + 2 OFF
group unchanged
6
Daitem security system
Switching the system ON (Arming) when an ENTRANCE is OPEN or there is a FAULT
The control panel is factory configured to prevent the system from being armed when a protected entrance door fitted with a contact sensor point is open or there is a protection mechanism fault. This factory configuration can be modified by your installer.
Example: system armed with (an) entrance(s) open.
Switch the system ON
Switch the system ON
Close the entrance
“beep,
entrance 2
open”
End of exit time delay
“beep,
ON”
“beep,
ON”
The control panel
is not ON
The system can be switched on and armed if there is no anti-tamper fault or entrance open.
SWITCHING OFF YOUR SYSTEM UNDER DURESS
(feature only accessible through remote
monitoring)
This feature allows you to discretely send out a warning if you are forced to disarm your alarm system under threat.
The system behaves in exactly the same way as if you were disarming it but it sends a specific alert message to the remote
central station monitoring company via the telephone line.
0
master code
OFF
This duress option needs to be selected by your installation company and
with the agreement of the central station monitoring company.
Exit time delay:
The exit time delay is the time you have to leave the
building without triggering the alarm devices. With the
help of your installer you can determine the time delay
best suited to the way you wish to use the system.
The control panel indicates the end of the time delay
by repeating the “system armed” voice message.
Entry time delay:
The entry time delay is the time you have to disarm
(turn OFF) the system from inside the building (using a
keypad for example) without triggering the alarm system. With the help of your installer you can determine
the time delay best suited to the way you wish to use
the system.
A “protection active” voice message and/or siren
sounding can also tell you that your system is active
and will trigger unless it is disarmed.
7
User guide
THE INFORMATION KEYPADS PROVIDE INFORMATION ABOUT DEVICE
STATUS AND MESSAGES FROM THE CONTROL PANEL
3
4
Issues
Anomalies
Alarmes
3 secs.
for normal
operation
{
2
The information keypads allow you to:
• operate your system,
• check the system’s status at any time.
The voice keypads provide all control panel messages and indicate:
• the status of the protection groups,
• the status of the doors and windows which have contact sensors fitted,
• alarms,
• faults.
{
Groupes
1
5 secs.
for contact
sensor points,
faults or alarms
LED Indicator lamp and voice message indications:
System status
LED Indicator lamps lit
Group 2
Group 3
Group 4
OFF
G
G
G
G
“Beep, OFF”
Armed*
R
R
R
R
“Beep, Armed”
Partial 1
R
Partial 2
Contacts
Faults
Alarms
Voice message
Group 1
“beep, armed, partial 1”
“beep, armed, partial 2”
R
Armed group 1
R
X
X
X
“Beep, armed, group 1”
Armed group 2
X
R
X
X
“Beep, armed, group 2”
Armed group 3
X
X
R
X
“Beep, armed, group 3”
Armed group 4
X
X
X
R
“Beep, armed, group 4”
OFF group 1
G
X
X
X
“Beep, OFF, group 1”
OFF group 2
X
G
X
X
“Beep, OFF, group 2”
OFF group 3
X
X
G
X
“Beep, OFF, group 3”
OFF group 4
X
X
X
G
“Beep, OFF, group 4”
Presence (stay)
mode
O
“Beep, armed, presence mode”
R
Alarm memory
“Beep, OFF, alarm system"
Y
Fault memory
“Beep, armed, fault, system”
Y
Contact open
“Beep, armed, contact X open”
* without anti-tamper system fault or entrance open
G
green LED indicator lamp
for 3 secs.: group OFF
X
: status of groups unchanged
R
red LED indicator lamp for 5 secs.:
alarm indication
R
red LED indicator lamp
for 3 or 5 secs.: group armed
O
orange LED indicator lamp for 3 secs.:
control panel in presence mode
Y
yellow LED indicator lamp
for 5 secs.: faults or entrances open
Only the commands sent from the control and information keypad light the LED indicator lamps.
Only the commands issued from the voice keypad generate the above voice messages.
Commands issued by another control unit have no effect on the voice keypad.
8
Daitem security system
MODIFYING YOUR ACCESS CODES
Modifying your MASTER CODE
The master code provides the main user with access to all system controls.
✱
5
✱
0
✱
Current
master code
New master code
✱ ✱
Repetition
of new master code
Example (do not copy):
((((
long beep
(
1
2
3
8
✱
5
✱
0
0
8
9
✱
6
0
8
9
✱ ✱
6
For reasons of security we recommend you change your keypad access codes regularly and keep the keys
clean. To prevent any undesired calls to your remote monitoring company, do not end your master code
with a “0”.
Modifying your USER CODES
The user codes limit access to specific functions. They are designed for occasional users.
✱
2
✱
✱ ✱
{
✱
from 1 to 32*
Master code
New user code
Repetition
of new user code
Example (do not copy):
1456: user code 2
(
((((
1
2
3
8
✱
0
2
2
✱
1
4
5
✱
6
1
4
5
6
long beep
✱ ✱
When a user code is saved it is automatically authorised. The user code authorisation sequence does not need
to be entered again.
DISABLING or ENABLING your USER CODES
The following procedures enable or disable user codes without modifying their programming.
✱
2
✱ ✱
{
✱
Master code
from 1 to 32*
0 : disable
1 : enable
* The control keypad and control and information keypad have 4 user codes.
The control interface has 32 user codes depending on the control panel model.
The voice keypad with tag reader have 8 user codes.
9
User guide
RESTRICTING ACCESS TO CONTROL FUNCTIONS
RESTRICTING access with user code
The user codes can provide separate restricted access to:
• certain keypad control keys,
• certain groups.
Only the control keys or groups selected during the master programming can be accessed when a user code is entered.
To allocate a user code to (a) certain key(s) only, press:
✱
Master code
user code
from 1 to 32
...
✱
✱ ✱
{
✱
2
{
✱
repetition
of user code
control keys
authorised
Arrêt
Example:
To allocate user code 1 to Partial 1 operation only, press:
1
2
3
8
✱
2
0
✱
1
1
2
1
Marche
Partiel 1
✱
3
1
2
1
3
✱
✱ ✱
Partiel 2
Présence
Alerte
Partial 1 key
To allocate a user code to (a) certain group(s) only, press:
✱
Master code
✱
user code
repetition
of user code
from 1 to 32
1
...
8
{
✱
2
{
✱
n° of groups
authorised*
In this way the user code only allows the authorised groups to be armed or switched off (disarmed).
✱ ✱
* The number of
telephone numbers
depends on the
control panel model.
RESTRICTING access with tags
Tags may have separate access restricted to certain control keys and groups.
Only the commands and groups selected during programming are accessible when the tag is used.
• To restrict a tag to certain control key(s), press:
...
✱
3
✱ ✱
{
{
✱
3
{
✱
Master code
control key(s)
tag n° (01 to 24)
Example, to restrict tag 02 to Partial 1 control, press:
1
2
3
8
✱
3
0
✱
2
0
3
2
Arrêt
✱
✱ ✱
In this case, only the Partial 1
key is accessible using tag 02.
Marche
Partiel 1
Partiel 2
Partial 1 key
Présence
Alerte
• To restrict a tag to certain group(s), press:
✱
3
1
...
4
✱ ✱
{
{
✱
3
{
✱
Master code
groups 1 to 4
tag n° (01 to 24)
Example: to restrict tag 01 to Group 2, press
1
2
3
8
✱
3
0
1
✱
3
0
1
✱
10
2
✱ ✱
In this case, only Group 2
ARMED and OFF control is
accessible using tag 01.
Daitem security system
• To cancel tag restrictions, press:
3
✱
0
✱ ✱
✱
0
✱ ✱
{
✱
3
{
✱
master code
tag n° (01 to 24)
Example, to cancel restrictions for tag 02, press:
1
2
3
8
✱
3
0
✱
2
0
3
2
In this case, access restrictions for tag 02
are deleted.
• Combined restriction of a control key and a group
✱
3
✱ ✱
{
✱
3
{
✱
master code
group
da 1 a 4
tag n° (01 to 24)
pulsante
di comando
Example: to restrict tag 01 to group 1 ARMED/OFF control and to the Partial 1 key,
press:
1
2
3
8
✱
3
0
1
✱
3
0
1
✱
1
✱ ✱
Partial 1 control key
ENABLING and DISABLING a tag
A programmed tag is automatically enabled.
To enable or disable a tag, press:
✱
3
✱ ✱
{
✱
codice
principale
tag n° (01 to 24)
0 : disabled
1 : enabled
Examples:
• to disable tag 01, press:
1
2
3
8
✱
3
0
1
✱
0
✱ ✱
0
2
✱
1
✱ ✱
• to enable tag 02, press:
1
2
3
8
✱
3
11
In this case, only Group 1 ARMED
and OFF control and the Partial 1 key
are accessible using tag 01.
User guide
REGULARLY TESTING YOUR SYSTEM: TEST MODE
Once a year or before going away for a long period, we advise you to test your security system.
The test mode will allow you to test each system unit.
Loud siren sounding can cause hearing problems and the necessary precautions must therefore be taken when
testing device triggering.
➊ Switch the control panel to test mode
“beep, date, time,
test mode”
2
master code
➋ Test each detector
• Move in front of each motion detector installed in rooms (offices, etc.).
• Check the system’s voice message.
“beep, intrusion,
detector n°”
)))))
Before moving in front of an infrared detector, wait for 90 secs before entering the room where the detector is fitted.
• Open and then close all the
entrances protected by door and window or multicontact detectors.
• Check the system's voice message.
)))))
“beep, intrusion,
detector n°”
)))))
➌ Test each remote control unit
• Press the OFF button on each
remote control.
or
• Enter your master code and press the
OFF button on each keypad.
or
or
“beep, OFF,
remote control n°”
))))
➎ Put the control panel back to user mode
“beep, date,
time, OFF”
1
master code
12
(
Press for more than 2 secs
(
))))
Alert
Gradual siren
sounding
for 3 secs
((((
(
((((
(
((((
Press the Alert key on a remote control
for more than 2 seconds.
((((
➍ Test the alarm siren units
Gradual siren
sounding
and strobe
for 5 secs
Daitem security system
PERFORMING A REAL TEST ON YOUR SECURITY SYSTEM
You are now going to perform a real test on your security system. This test will trigger the alarm units and transmit a message to your remote central station monitoring company or individual correspondents by phone.
We recommend you warn the person(s) in charge of remotely monitoring your system beforehand.
➊ Close all the entrances and leave the protected areas
for at least 90 secs to allow any movement detectors to set.
➋ Switch ON (ARM) the system
• when it receives the ON command, the
control panel responds: "beep, armed"
"beep, armed"
➌ Wait until the end of the Exit time delay
“armed”
• the control panel announces: “armed”
➍ After 90 secs enter a protected room
(
((((
(
(
((((
(
((((
((((
• the control panel and siren are triggered,
• the telephone dialler calls the
programmed correspondents depending
on the type of event transmitted.
➎ Let the sirens sound for 30 sec.
and then switch OFF (disarm) the system.
• on receipt of the OFF command, the
sirens stop and the control panel responds:
“Beep, OFF, on 21 5 2005 at 7:30 PM,
intrusion, detector 3, group 1”.
“Beep, OFF, on 21 5 2005 at 7:30
PM, intrusion, detector 3, group 1”.
➏ Check the alarm was transmitted by phone
to your programmed correspondents*.
* When the call is to an individual alone, the system OFF command stops the call transmission to the correspondents.
13
User guide
DEFINING ACCESS FOR REMOTE
UPLOADING/DOWNLOADING OPERATIONS
In compliance with current regulations, access to system uploading or downloading requires your explicit authorisation; this
is why, by default, uploading/downloading operations are only authorised if your control panel is in Test mode (see page
13). Using the uploading/downloading software your installer can perform different operations remotely:
• remote configuration: to check or modify your system’s configuration,
• remote inhibition: to activate or inhibit one or several system devices,
• events log reading: to check the list of time and date-stamped system events that have occurred.
You can modify your installer’s uploading/downloading access rights and conditions. It is up to you to define the most suitable procedure to be adopted with your installer.
FORBIDDING access to uploading/downloading operations
✱
1
9
3
✱
0
✱
✱ ✱
0
Master code
AUTHORISING access to uploading/downloading according to the code used
and the system status
✱
Master code
1
9
3
✱
✱
✱ ✱
1 : uploading/downloading code
0 : system in test mode
2 : engineer installer code
1 : inhibited
3 : uploading/downloading
2 : 24 hour* according
and engineer installer code
to system status
14
* In 24 hour mode, access to uploading/
downloading via the engineer installer
code is not authorised if your system is
ARMED.
Daitem security system
YOUR TELEPHONE DIALLER WARNS YOUR CORRESPONDENTS
OR KEYHOLDERS
Procedure for a voice call to an individual
“beep,
system n° 11,
intrusion,
detector n°,
group n°”
“to listen
in press *”
“press 0 to
acknowledge
and terminate”
“to listen
in press *”
“thank
you”
ng
riiii iing
rii
3
2
1
4
7
8
4
9
7
0
3
2
1
6
5
8
4
9
7
0
4
6
5
8
7
9
Your
correspondent’s
telephone rings
the message
is repeated
(60 s)
the message
is repeated
(5 times max.)
6
5
8
9
0
0
3
2
1
4
7
4
6
5
8
7
9
3
2
1
3
2
1
3
2
1
6
5
6
5
8
9
0
0
the telephone dialler signal
is acknowledged
* listen in
for 60 sec.
End of call.
The telephone
dialler hangs
up
* To make it easier to listen in to the site, the control panel siren temporarily stops.
Procedure for a call to a remote central station monitoring company
call picked up by remote
monitoring company
Remote
monitoring
company
User site
ring
test
monitoring company
response frequency
frequency
transmitted
dialling
DTMF message transmitted
long beep
change to
listen-in mode
event
List of commands possible during the listen-in period
Depending on the alarm transmitted, you have access to a listen-in mode.
During this period, you can send commands using the keys on your telephone handset unit.
Type of command
Command n°
Command for all speak-out (talk-back) loud speakers
5
Command for all listen-in microphones
6
Repetition of listen-in period (1 min.)
Command to stop listen-in and terminate transmission
15
User guide
YOUR TELEPHONE DIALLER WARNS YOUR CORRESPONDENTS
OR KEYHOLDERS (cont.)
SAVING or MODIFYING your correspondents’ numbers
You can programme telephone numbers for your correspondents using the control interface.
Memories 81 to 88 are dedicated to your correspondents’ numbers.
Memory 89 is dedicated to the information number.
✱
✱
8
✱ ✱
...........
telephone n°
(20 figures max.)
Master
code
1 : 1st number
6 : 6th number
2 : 2 number
7 : 7th number
3 : 3rd number
8 : 8th number
4 : 4 number
9 : information
nd
th
*
number
5 : 5th number
The telephone numbers must
be different.
If the memory is empty,
the control panel generates a long
beep at the end of the reading.
* The number of telephone numbers
depends on the control panel model.
CHECKING and TESTING the numbers saved
You can check your correspondents’ telephone numbers separately using the control panel keypad or the control interface.
✱
✱
8
✱ ✱
Master
code
1 : 1st number
6 : 6th number
2 : 2 number
7 : 7 number
3 : 3rd number
8 : 8th number
4 : 4th number
9 : information
nd
*
th
number
5 : 5th number
TESTING the call to your correspondents
You can test your correspondents’ telephone numbers separately.
First let your correspondents know that you are going to perform a test call.
We recommend that you systematically do this every time you save a new number.
5
8
Master
code
1 : 1st number
6 : 6th number
2 : 2 number
7 : 7th number
3 : 3rd number
8 : 8th number
4 : 4 number
9 : information
nd
th
5 : 5th number
*
number
DELETING a saved NUMBER
You can delete your correspondents’ telephone numbers separately.
✱
Master
code
8
✱ ✱
1 : 1st number
6 : 6th number
2 : 2nd number
7 : 7th number
3 : 3rd number
8 : 8th number
4 : 4th number
9 : information
5 : 5th number
0
✱ ✱
*
number
16
Daitem security system
Test call procedure
“to listen
in press *”
3
2
1
4
7
8
4
9
7
0
Test call triggered
Dialling
“press 0 to
acknowledge
“beep, test call” and terminate”
4
6
5
8
7
9
Message
repeated
(1 min.)
8
4
9
3
2
1
6
5
7
0
0
8
4
9
The test message
is repeated
(20 sec.)
3
2
1
6
5
7
0
Identification
message
“thank you”
3
2
1
3
2
1
6
5
“beep,
system n° 11”
6
5
8
9
0
The telephone dialler signal
is acknowledged
End of call.
The telephone
dialler hangs up
: press on “0” on the telephone handset unit to acknowledge and terminate the telephone transmission.
Telephone dialler call cycle procedure
Your first correspondent does not answer as s/he is already on the phone or has not terminated the call cycle correctly:
• the telephone dialler calls the number saved in the next memory,
• if none of the correspondents stop the call cycle, or they are all on the phone or not answering, the complete call sequence
is carried out.
Acknowledgement
and termination
Procedure
Cycle 1:
Cycle 2:
Cycle 3:
memory 81
1st
1st
1st
1st
1st
memory 82
2nd
2nd
2nd
2nd
2nd
memory 83
3rd
3rd
3rd
3rd
3rd
memory 84
4th
4th
4th
4th
4th
memory 85
5th
5th
5th
5th
5th
memory 86
6th
6th
6th
6th
6th
memory 87
7th
7th
7th
7th
7th
memory 88
8th
8th
8th
8th
8th
+
Information call*:
memory 89
9th
For each cycle, if the
1st calls are not
acknowledged,
transmission continues
on to the following
numbers in the cycle.
As soon as one of the
cycle calls has been
acknowledged,
transmission stops.
The last cycle is
followed by the
information call.
9th
* For digital transmission to a remote monitoring central station company or voice transmission to an individual correspondent for information purposes (owner’s mobile for example). This information call does not acknowledge and terminate the
cycle.
Your installer can be warned of any problems with the system directly as well as by alarm transmissions.
17
User guide
THE CONTROL PANEL INDICATES ALARMS AND WARNS CORRESPONDENTS
• Alarms (intrusion, personal protection, technical problem,
tampering or fire) are indicated:
• when a Disarm command (switch OFF) is received,
• when the system is remotely controlled.
• Voice indication specifies:
• the date and time the alarm occurred,
• the type of alarm,
• the identity of the device generating the alarm.
Protection against intrusion
Control panel voice message
“beep, date, time, intrusion,
detector n°, group n°”
“beep, date, time,
intrusion confirmed,
detector n°, group n°”
Events
Message transmitted
Intruder on premises.
BEEP; INTRUSION; DETECTOR N°, GROUP N°
Intruder moving about on premises.
BEEP; INTRUSION CONFIRMED;
DETECTOR N°, GROUP N°
Personal Attack
24-hour
Control panel voice message
“beep, date, time, alert,
remote control n°”
Events
Alarm or silent alarm triggered by control unit.
Message transmitted
BEEP; ALARM
Technical protection
24-hour
Control panel voice message
“beep, beep, beep, beep,
technical alarm,
detector n°”
Events
Technical protection triggered by sensor
associated with the universal transmitter.
Message transmitted
BEEP; TECHNICAL ALARM; DETECTOR N°
Protection against fire
24-hour
Control panel voice message
“beep, date, time, fire
alarm, detector n°”
“beep, date, time, fire
alarm, remote control n°”
Events
Message transmitted
Fire protection triggered by a detector.
BEEP; FIRE ALARM; DETECTOR N°
Fire protection triggered by a remote
control unit.
BEEP; FIRE ALARM; REMOTE CONTROL N°
Protection against system tampering
24-hour
Control panel voice message
Events
Message transmitted
“beep, date, time, tamper,
remote control,
control panel n°”
Attempt to open or remove a control interface.
BEEP; TAMPER; REMOTE CONTROL;
CONTROL PANEL
“beep, date, time, tamper,
remote control n°”
Attempt to open or remove a keypad.
BEEP; TAMPER; REMOTE CONTROL N°
“beep, date, time, tamper,
control panel”
Attempt to remove or open the control panel.
BEEP; TAMPER; CONTROL PANEL
“beep, date, time, tamper,
siren n°, or, tamper,
relay n°”
Attempt to remove a siren
or radio repeater relay.
BEEP; TAMPER; SIREN N°
or
BEEP; TAMPER; RELAY N°
“beep, date, time, tamper,
detector n°, group n°”
Attempt to open or remove a detector.
BEEP; TAMPER; DETECTOR N°
“beep, date, time, tamper,
radio”
Radio jamming detected.
“beep, date, time, tamper,
network”
Telephone line cut detected.
The alarm memory is automatically deleted the next time the system is armed.
18
Daitem security system
THE CONTROL PANEL INDICATES FAULTS
• The control panel continuously monitors the state of
system devices:
• battery,
• anti-tamper system,
• telephone line availability,
• radio link.
• The control panel indicates faults:
• when an ARM or DISARM command is received,
• by (remotely) checking system status.
Device battery failure
Control panel voice message
Events
Message transmitted
“Beep, fault, battery,
control panel”
Control panel battery low.
BEEP; FAULT; BATTERY; CONTROL PANEL
“Beep, fault, battery,
detector n°”
Detector battery low.
BEEP; FAULT; BATTERY; DETECTOR N°
“Beep, fault, battery,
siren n°”
Siren battery low.
BEEP; FAULT; BATTERY; SIREN N°
“Beep, fault, battery,
relay n°”
Radio repeater relay battery low.
BEEP; FAULT; BATTERY; RELAY N°
Keypad or control interface battery low.
BEEP; FAULT; BATTERY; REMOTE CONTROL N°
or BEEP; FAULT; BATTERY; REMOTE
CONTROL; CONTROL PANEL
“Beep, fault, battery,
remote control n° or remote
control, control panel”
Device anti-tamper mechanism failure
Control panel voice message
“beep, fault, tamper,
control panel”
“beep, fault, tamper,
detector n°, group n°”
“beep, fault, tamper, siren
n° or tamper, relay n°”
“beep, fault, tamper,
remote control n°”
Events
Message transmitted
Control panel anti-tamper system fault.
BEEP; FAULT; TAMPER; CONTROL PANEL
Detector anti-tamper system fault.
BEEP; FAULT; TAMPER; DETECTOR N°;
GROUP N°
Siren or radio repeater relay anti-tamper system
fault.
BEEP; FAULT; TAMPER; SIREN N°
or
BEEP; FAULT; TAMPER; RELAY N°
Control unit anti-tamper system fault.
BEEP; FAULT; TAMPER; REMOTE CONTROL N°
Telephone line fault
Control panel voice message
“Beep, fault, network,
control panel”
Events
Message transmitted
Connection fault or telephone line unavailable.
Device radio link fault
Control panel voice message
Events
Message transmitted
“Beep, fault, radio link,
control panel"
Loss of control panel radio link.
BEEP; FAULT; RADIO LINK; CONTROL PANEL
“Beep, fault, radio link,
detector n°, group n°"
Loss of radio link between a detector
and the control panel.
BEEP; FAULT; RADIO LINK; DETECTOR N°,
GROUP N°
“Beep, fault, radio link,
siren n° or relay n°"
Loss of radio link between a siren
or a radio repeater relay.
BEEP; FAULT; RADIO LINK; SIREN N°
or
BEEP; FAULT; RADIO LINK; RELAY N°
“Beep, fault, radio link,
remote control n°"
Loss of radio link between a keypad
and the control panel.
BEEP; FAULT; RADIO LINK; REMOTE
CONTROL N°
19
User guide
CHECKING THE EVENTS LOG
The events log contains the last 500 date and time-stamped events occurring in the system.
The events log records the following events:
• intrusion protection status changes,
• automatic inhibition of contacts on doors and windows remaining open,
• alarms,
• faults,
• system configuration modifications.
To access the events log locally using the control panel keypad:
1 0
master code
1
to move on to next event
2
to repeat the event
0
to end
Each event recorded in the log is described as follows:
• date and time,
• event name,
• identity of devices causing event.
20
Daitem security system
REMOTELY OPERATING YOUR SECURITY SYSTEM (if telephone module board installed)
4
7
“Press * and
enter access
code”
3
2
1
6
5
8
9
0
Your control panel picks
up the call
Call your control panel
using a DTMF tone
dial telephone
device (fax,
answering
machine, etc.)
3
2
1
6
5
4
7
8
9
0
“Beeeeep,
system status:
OFF”
Your control panel confirms the code
is correct with a long beep followed
by announcing the system status.
master code
enter the switching code
(1 to 9, programmed
by your installer)
another device picks up the call
• After 20 secs. without receiving an order, your control panel stops and terminates the transmission.
• Pressing the
key on your telephone handset unit takes you back at any time to the voice menu
at the start.
3
2
1
4
7
6
5
8
9
0
➀
“Voice menu
proposed”
Action on keypad
“To check system
status press
”
 system status announced
“For Disarming
press
”
“To modify system
status press 1 ”
➁
➂
Result of action
“For system control,
press 2 ”
 control panel OFF
“For Arming
press 1 ”
 control panel armed
“For menu
press
”
 return to main menu
command sent
 (see table below)
remote control n°
“To check
press
”
To modify the call
number press 3 ”
number saved
 announced
.......
“To modify
press 1 ”
➃
new number saved
 announced
new
n° of 1st
correspondent
“For menu,
press
”
Command sent
User mode
Test mode
OFF
Armed
Armed; Partial 1
Armed; Partial 2
Armed; Presence mode
Pulse light
Light OFF
Light ON
Pulse Relay 1
OFF Relay 1
Armed Relay 1
Command n°
1
2
2
1
2
3
2
5
2
7
3
3
5
5
2
5
4
6
6
2
6
4
Command sent
Pulse Relay 2
OFF Relay 2
Armed Relay 2
Pulse Relay 3
OFF Relay 3
Armed Relay 3
Pulse Relay 4
OFF Relay 4
Armed Relay 4
OFF; Group 1
OFF; Group 2
OFF; Group 1 2
OFF; Group 3
 return to main menu
Command n°
7
7
2
7
4
8
8
2
8
4
9
9
2
9
4
1
3
1
1
3
3
1
3
5
1
3
7
21
Command sent
OFF; Group 1 3
OFF; Group 2 3
OFF; Group 1 2 3
OFF; Group 4
OFF; Group 1 4
OFF; Group 2 4
OFF; Group 1 2 4
OFF; Group 3 4
OFF; Group 1 3 4
OFF; Group 2 3 4
OFF; Group 1 2 3 4
Armed; Group 1
Armed; Group 2
Command n°
1
3
9
1
4
1
1
4
3
1
4
5
1
4
7
1
4
9
1
5
1
1
5
3
1
5
5
1
5
7
1
5
9
1
6
3
1
6
5
Command sent
Armed; Group 1 2
Armed; Group 3
Armed; Group 1 3
Armed; Group 2 3
Armed; Group 1 2 3
Armed; Group 4
Armed; Group 1 4
Armed; Group 2 4
Armed; Group 1 2 4
Armed; Group 3 4
Armed; Group 1 3 4
Armed; Group 2 3 4
Armed; Group 1 2 3 4
Command n°
1
6
1
6
9
1
7
1
1
7
3
1
7
5
1
7
7
1
7
9
1
8
1
1
8
3
1
8
5
1
8
7
1
8
9
1
9
1
7
User guide
ADDITIONAL KEYPAD FUNCTIONS
Checking system status
• Control keypads or interface:
4
or
master
code
“beep,
system status”
master
code
System status
• Keypad with tag reader:
4
tag presented within 3 sec.
after pressing
Partiel 2
or
Etat
Système
System status
Silently operating your system
• Control keypads or interface:
...
6
...
{
3
master
code
Wait
2 sec.
Key(s)
for command
to be sent
• Keypad with tag reader:
...
6
...
Partiel 2
Wait
2 sec.
tag presented within 3 sec.
after pressing
Etat
Système
{
3
Key(s)
for command
to be sent
Triggering an alarm
• Control keypads or interface:
2
2
or
Alert (personal attack)
Press for more than 2 sec.
(
((((
(
(
((((
(
((((
((((
master
code
• Keypad with tag reader:
2
2
or
Alert (personal
attack)
Partiel 2
tag presented within 3 sec.
after pressing
Etat
Système
Press for more
than 2 sec.
Loud siren sounding can cause hearing problems. The necessary precautions must therefore be taken
when performing device triggering tests.
Triggering a silent alarm (if a keypad key has been programmed)
• Control keypads or interface:
2
4
Silent alarm
or
master
code
Press for more than 2 sec.
• Keypad with tag reader:
2
4
or
Silent alarm
Partiel 2
tag presented within 3 sec.
after pressing
Etat
Système
Press for more
than 2 sec.
22
Daitem security system
Triggering a fire alarm (if a keypad key has been programmed)
• Control keypads or interface:
2
3
or
(
((((
(
((((
((((
(((
((((
(
Fire alarm
((
master
code
((((
master
code
• Keypad with tag reader:
3
2
or
Partiel 2
tag presented within 3 sec.
after pressing
Etat
Système
Fire alarm
Activating or de-activating the chime*
• Control interface:
(
(
5
0
4
master
code
Changing your system to summer time or winter time*
5
0
1
“beep,
17/3/2004,
time?”
master
code
5
0
2
master
code
* These functions can only be accessed
using the hardwired control interface
remote keypad or the control panel
keypad.
23