Download Service Manual
Transcript
18.09.2001 / Page 2 Doc. No: 4812 712 16504 AWM 5130 8570 513 20200 Whirlpool Europe Customer Service SERVICE Technical data Dimensions Height Width Depth Door lock 85 59.5 56 cm cm cm Weight Without packing 73 kg 230 50 2.3 10 V Hz kW A 48 l 5 3 5 2.5 1.5 2.5 1.5 1 kg kg kg kg kg kg kg kg Level 1 Switching point Switching back point 60 ± 5 35 ± 5 mmWc mmWc Overflow 280 ± 20 mmWc Drum Volume 3“ - 6’’ 60“ - 90’’ 230 V 16 (4) A Heating element Kind of heating Main Connection Voltage Frequency Power consumption Fuse rating Lock time (20 ˚C) Unlock time Nominal voltage Nominal current: Contact 4 - 5 Nominal Voltage Nominal power resistance R 25 Resistance NTC : 0˚C 30˚C 40˚C 50˚C 60˚C 70˚C 95˚C Tubular heating element with NTC - sensor 230 V 2050 W 22 - 28 Ω 35.9 9.8 6.6 4.6 3.2 2.3 1.1 kΩ kΩ kΩ kΩ kΩ kΩ kΩ 60 8 0.5 - 10 220 / 240 50 ˚C l/min bar V Hz 160 170 35 6 3.4 - 4.5 V V mA VA kΩ 230 0,3 34 50 155 yes 14 ± 2 V A W Hz Ω ± 7% 170˚C l/min Capacity of dry laundry Cotton/coloured Cotton rapid Cotton short Easy care Easy care rapid Easy care short Delicate Wool Water Level Water level inside the drum (only switching level inside the drum) Level 1 25 - 39 mm Overflow 267 - 306 mm Nominal currents Contacts 11 - 12 11 - 14 11 - 16 Contact system 11 - 12 - 14 11 - 16 Damping system 4 (4) 16 (4) 1 (1) A A A spring contact sliding contact no Inlet valve Water temperature Rated flow <1 bar Pressure range Nominal voltage Frequency Starting voltage: < 6 bar 6 - 10 bar Nominal current Nominal power Nominal (20 ˚C) Drain pump (synchronous) Nominal Voltage Nominal current Nominal power Frequency Resistor (coil) Motor protection Capacity(1,25m height)