ENG 6.6 Continuous cycle Par. d0 To activate the continuous cycle by keyboard see Chapter 3 (parameter value cc> 0). During operation in a continuous cycle, the compressor continues to operate regardless the control, for the time “cc”, to lower the temperature even below the set point. The continuous cycle is stopped after the time “cc” or when reaching the minimum specified temperature, corresponding to the minimum temperature alarm threshold (AL). If, after the end of the continuous cycle, the temperature falls below the minimum temperature threshold, the low temperature alarm signal can be ignored by suitably setting the c6 parameter: the alarm bypass delay time after continuous cycle. Par. cc c6 A5 A9 Description Continuous cycle duration Low temperature alarm delay after continuous cycle Digital input configuration 2 (DI2) … 14 = Continuous cycle activation Digital input configuration 3 (DI3) … 14 = Continuous cycle activation Def 0 2 Min 0 0 Max 15 250 U.M. hour hour 0 0 14 - 0 0 14 - dt1 dt2 dP1 dP2 d6 Description Type of defrost 0 Heater by temperature 1 Hot gas by temperature 2 Heater by time 3 Hot gas by time End defrost temperature, main evaporator End defrost temperature, auxiliary evaporator Maximum defrost duration Maximum defrost duration, auxiliary evaporator Terminal display during defrost 0 = Temperature alternated with dEF 1 = Last temperature shown before defrost 2 = dEF Def 0 Min 0 Max 3 U.M. - 4 -50 200 °C/°F 4 -50 200 °C/°F 30 30 1 1 250 250 min min 1 0 2 - Sd dt1 dt1-1 t 6.7 Door switch control ON d0=0, 1 DEF See chap. 4 OFF t d0=2, 3 ON DEF 6.8 Defrost OFF Introduction These parameters (dd1…dd8) can be used to set up to 8 defrost events linked to the system clock (RTC) Par. dd1…8 hh1…8 nn1…8 Description Defrost 1…8: day 0 Disabled 1…7 Monday…Sunday 8 From Monday to Friday 9 From Monday to Saturday 10 Saturday and Sunday 11 Daily Defrost 1…8: hour Defrost 1…8: minute Def 0 Min 0 Max 11 dP1 Fig. 6.h U.M. - Key t dt1 dP1 Sd d0 DEF 0 0 0 0 23 59 t Time End of defrost temperature Maximum defrost duration Defrost Probe Type of defrost Defrost hour min. UltraCella allows you to manage the following types of defrost, depending on parameter d0: 0. electric heater defrost by temperature (placed near the evaporator); 1. hot gas defrost by temperature. 2. electric heater defrost by time; 3. hot gas defrost by time. 1. electric heater defrost (d0 = 0, 2): operating cycle. The operating cycle refers to default values of the parameters F2 and F3. C CMP Note: Ed1 and Ed2 indicate that the defrost ended due to timeout. L The end of the defrost cycle can be by temperature, and in this case it is necessary to install the defrost probe Sd (to select between B2 and B3) or by time. In the first case the defrost ends if the probe Sd measures a value greater than the value of dt1 or dP1 time has elapsed, in the second case if the defrosting phase exceeds the maximum time dP1. At the end of the defrost the controller can enter in dripping status (present if dd> 0), in which the compressor and the fans are turned off, and subsequently in the state of post-dripping (if present Fd> 0), in which the control resumes with fans off. You can choose the display on the user terminal during defrost, using parameter d6. F S PDV T V2 M B3 E Fig. 6.i 39 UltraCella +0300083EN - rel. 1.3 - 30.06.2014