Download User Manual - LTT
Transcript
5.2 Operating elements and connections This user manual describes the MPVZ-350 as a reference. The other models are similar in construction. 1 Power on/off Turns the unit on and off. The power indicator lights up when the unit is powered on. 6 LED level meter for the output signal 7 Controls ZONE 1 to 4 Volume controls for the PA zones 1 to 4. 2 Control LEVEL Master control for the total volume. 8 Controls LINE 1 to 3 Volume controls for the line inputs LINE 1 to 3. 3 Tone controls 2-way tone control for the output signal: bass and treble. 9 Button CHIME For releasing the chime. 4 Controls MIC 1 to 3 Volume controls for the microphone inputs MIC 1 to 3. 10 LED FAULT 5 Input PRIORITY MIC 3 6.3 mm jack for connecting a dynamic microphone. This input has priority: In case of an announcement via this microphone channel the level of the other signal sources is attenuated–depending on the rear control PRIORITY LEVEL–thereby increasing the intelligibility of the announcement. Lights up with activated protective circuit: • for a few seconds after switching-on unit the speaker outputs are ready for operation • during operation when the protective circuit has switched off the speakers in case of a defect 11 Power LED 22/28 00053683.DOC, Version 1.2