Download User manual
Transcript
BLCDP-4M12LT-2AI-PT-2AI-PT 4 Technical data Type Ident-No. BLCDP-4M12LT-2AI-PT-2AI-PT 6811184 Supply voltage Admissible range System power supply Voltage supply connection Operating current Nominal voltage Vi Nominal voltage Vo Max. sensor supply Isens Max. load current Io 24 VDC 18...30 VDC via separate source 2 x M12, 5-pin 750 mA 24 VDC 24 VDC 4A 4A Fieldbus transmission rate Adjustment transmission rate Fieldbus addressing range Fieldbus addressing Service interface Fieldbus connection technology Fieldbus termination 9.6 kbps…12 Mbps auto detetcion 0...99 2 decimally coded rotary switches RS232 interface 2 x M12, 5-pin, reverse keyed external Analog inputs Input type Type of input diagnostics Sensor supply Basic fault limit at 23 °C Repeatability Temperature coefficient Resolution Measuring principle Measured-value display Edition • 2011-2-23 Operating temperature Storage temperature Extended vibartion resistance - up to 20 g (at 10 to 150 Hz) Protection class housing material 7 / 22011 PT100, 200, 500, 1000 & NI100, 1000 channel diagnostics 24 VDC < 0.2 % < 0.05 % < 300 ppm/°C of full scale 16 bit Sigma Delta 16 bit signed integer 12 bit full range left justified -40...+70 °C -40...+85 °C firm mounting on base plate or machine IP69K Glass-filled nylon, nickel plated brass connectors Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com