Download USER MANUAL - CAMBOARD Electronics
Transcript
im Vertrieb von CAMBOARD Electronics VOLUME-PARAMETER = output volume parameters: [VALUE] either positive or negative digits (minus sign precedes negative values). “+” increase current value, “-“ decrease current value Window WIN-CUST WINDOW, HPOS, WIN- CUST WINDOW, HPOS, customization HW , VPOS, VH HW , VPOS, VH RESULT Parameters Description: fast window customization [WINDOW] “0” for main window; “1” for PiP window [HPOS] horizontal position value [HW] horizontal width value [VPOS] vertical position value [VH] vertical height value Set dual window state PIP PIP-MODE PIP PIP-MODE RESULT Get dual window state PIP? PIP PIP-MODE Parameters Description: PIP-MODE = Dual window state: "0" or "off" for single window. "1" or "on" to for dual window. Identification commands Command Syntax Response Protocol Handshaking #CR Read device model MODEL? MODEL MACHINE_MODEL Read device serial number SN? SN SERIAL_NUMBER Read device firmware version VERSION? VERSION MAJOR .MINOR .BUILD .REVISION Read device build date BUILD-DATE? BUILD-DATE YYYY/MM/DD HH:MM:SS ~OK CRLF Read device protocol PROT-VER? version PROT-VER 3000:MAJOR .MINOR Set machine name NAME MACHINE_NAME NAME MACHINE_NAME RESULT Read machine name NAME? NAME MACHINE_NAME Reset machine name NAME-RST to factory default* NAME-RST RESULT Network settings commands Network settings commands require admin authorization Command Set IP Address Syntax NET-IP IP_ADDRESS NTIP VP-771 - The VP-771 RS-232 Communication Protocol www.camboard.de Response NET-IP IP_ADDRESS RESULT 77 Tel. 07131 [email protected] Fax 07131 911203