Identification STANDARD TYPES ORDER NUMBER Tricolour device: Direct current / direct voltage Housing size: 96x48 mm M3-1VT5B.0001.470AD M3-1VT5B.0001.570AD M3-1VT5B.0001.670AD Options – breakdown of order code: M 3- 1 V T 5 B. 0 0 0 1. 6 7 2 A D Standard type M-line Dimension D physical unit Installation depth 139 mm, incl. plug-in terminal 3 Version A A Housing size 96x48x120 mm (WxHxD) 1 Setpoints 0 no setpoints Type if display V, A V 2 2 relay outputs 4 4 relay outputs Display colour Red-Green-Orange T Protection class 7 IP65 / plug-in Terminal Number of digits 5-digit 5 Digit height 14 mm Digital input without Supply voltage 4 115 VAC 5 230 VAC 6 10-30 VDC galv. insulated B Measuring input 1 Direct current, direct voltage 0 1 digital input (without sensor supply) I Analog output 0 without Interface RS232 3 X 1x 0-10 VDC, 0/4-20 mA Interface RS485 4 Y 2x 0-10 VDC, 0/4-20 mA Sensor supply 0 without 2 10 VDC / 20 mA (incl. digital input) 3 24 VDC / 50 mA (incl. digital input) Please state physical unit by order, e.g. m/min.