84 Chapter 10 Functions DEC HEX Function Information on the function 83 53 Load CFG from project Function MMC 90 5A Activate firmware load mode (for 20 s) Function MMC 91 5B Load firmware Function MMC 92 5C Load HEX file from project Function MMC 99 63 Reset firmware load mode Function MMC 111 6F Start automatic cooling adaptation 112 70 Start zone-wise automatic cooling adaptation 177 B1 Start current transfer all zones 200 C8 Switch on keylock Operating and display unit function 201 C9 Switch off keylock Operating and display unit function 440 1B8 Reset-acknowledge all alarms 441 1B9 Reset-acknowledge Alarm Output 1 442 1BA Reset-acknowledge Alarm Output 2 443 1BB Reset-acknowledge Alarm Output 3 501 1F5 Reset-acknowledge software reduction 502 1F6 Block group release Group functions 600 258 Start diagnostic function for sensor allocation Diagnostic function (code number 600) - Allocation of Sensor and Heating 601 259 Start heating current diagnostics function Diagnostic function (Code Number 601) - Start Current Measurement 602 25A End diagnostic function and delete alarms 759 2F7 Establish ex-works state and controller reset 921 399 Profibus DPEA: Read in object list 922 39A Profibus DPEA: Write object list into the EEPROM 985 3D9 Standard CPU matching 998 3E6 Delete EEPROM write errors 999 3E7 Reset control system Rev. 1.00.10 Subject to technical changes without notice For all zones, that should be adapted, set bit 0x08 in control byte for zone by interface. Code number 112 activates the cooling adaptation for the selected zones and resets bit.