Download Operating Instructions
Transcript
9.21.2 1st Offset level LEVEL 1 XX.X % The level 1 is the start level of the 1st Offset. Adjustable between 0 and 100% of the additional analogue input. Press the ¾ button to change to the next parameter 9.21.3 2nd Offset level LEVEL 2 XX.X % The level 2 is the start level of the 2nd Offset. Adjustable between 0 and 100% of the additional analogue input. Press the ¾ button to change to the next parameter 9.21.4 Intensity 1 INTENSITY 1 +XX.X % Only in combination with Level 1! This is the intensity of the 1st Offset of the required value at the zero point of the second analogue input. Setting range: -200% up to +200% of the sensor range Press the ¾ button to change to the next parameter 9.21.5 Intensity 2 INTENSITY 2 +XX.X % Only in combination with Level 2! This is the intensity of the 2ndOffset of the required value at the maximum point of the second analogue input. Setting range: -200% up to +200% of the sensor range To leave the submenu press ¾ longer than 3 seconds to change to SUBMENU Offset Press the ¾ button to change to the next parameter 52