Download American Standard 4662.002.075 Installation Guide

Transcript
Installation
Instructions
4662.002
SINGLE CONTROL
KITCHEN FILTER FAUCET
Thank you for selecting American-Standard...the benchmark of fine
quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these
instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M
The system and installation shall comply with applicable state and local regulations.
M 9 6 5 10 7
RECOMMENDED TOOLS
Regular Screwdriver
Phillips Screwdriver
Adjustable Wrench
Channel Locks
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping.
UNPACKING
1. Remove the Filter Faucet items from the carton. The illustration below shows all items after they have been
removed from the carton. Some items may be packaged partially assembled to other items.
FILTER
HOUSING
OPTIONAL
FILTER CAP
F30
FILTER
FILTER FAUCET
ASSEMBLY
UP
COLLET
SOAP DISH
*WATER
BOTTLE
UP
ESCUTCHEON
SINGLE HOLE
FILTER DECK PLATE
MOUNTING KIT
*Note: The water bottle has not been evaluated
to the NSF/ANSI 42 and 53 standards.
1
INSTALL FAUCET
CAUTION
4
Turn off water at
main supply.
Installation with DECK ESCUTCHEON: Apply a
light bead of plumbers putty to underside of
ESCUTCHEON (1) if mounting surface is uneven.
Figure A.
Place ESCUTCHEON (1) onto sink or mounting
surface. Insert all HOSES (2) and SHANK (3) through
ESCUTCHEON (1) and mounting surface. Figure A.
Assemble RUBBER WASHER (5), BRASS WASHER (6)
and threaded LOCKNUT (7) onto SHANK (3) from
underside of sink or mounting surface. Hand tighten
LOCKNUT (7). Check that rotation of HANDLE (4)
from HOT to COLD is centered. Figure B.
FILTER
HOT
Ha
n d le
COLD
t r a ve l i s c e n t e
red
1
PLUMBERS PUTTY
(If required)
MOUNTING
SURFACE
4
3
FACTORY
INSTALLED
SEAL
Figure B.
1
2
5
6
7
2
SECURE FILTER FAUCET TO MOUNTING SURFACE
Use a screwdriver to tighten SCREWS (1) on LOCKNUT (2).
Work your way around LOCKNUT (2), tightening the SCREWS (1)
slightly each time until all are snug to ensure even pressure.
RUBBER WASHER
METAL WASHER
2
1
3
CONNECT HOT AND COLD WATER SUPPLIES
Turn off hot and cold water supplies before beginning.
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left supply (Red Stripe) to Hot and right supply (Blue Stripe) to
the Cold wall supply. Use adjustable wrench to tighten
connections. Do not over tighten.
Faucet supplies are 20-1/2" long from base of faucet.
Note: If longer supply length is required, installer
must purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are
too long, loop as illustrated to avoid kinking.
LOOP SUPPLIES
IF REQUIRED
20-1/2"
BLUE
STRIPE
RED STRIPE
2
1
SUPPLY
VALVES
COLD
HOT
M 9 6 5 10 7
2
4
FILTER HOUSING INSTALLATION
Remove the COLLET ASSEMBLY (1) from the FILTER HOUSING (2).
Grasp the COLLET ASSEMBLY (1) and pull it down firmly from the
FILTER HOUSING (2). Figure A.
Place the FILTER DECK PLATE (3) over the mounting hole. Insert the
FILTER HOUSING (4) into the FILTER DECK PLATE (3).
The word “FRONT” should face you when installed. Figure B.
Figure A.
SEAL
FILTER
HOUSING
1
ORIENT
FILTER
HOUSING
4
3
BUMP
UP
PULL DOWN
TO REMOVE
COLLET
ASSEMBLY
(RETRACTED
AGAINST
STOP)
STOP
UP
2
UP
Figure B.
COLLET
ASSEMBLY
REMOVED
UP
Note: Position the COLLET ASSEMBLY (1) with the arrows pointing "up". Push the COLLET ASSEMBLY (1) back
onto the FILTER HOUSING (2). Make sure the COLLET ASSEMBLY (1) is pushed above the "Bump" on the Filter Housing.
Figure C.
Orient the Filter Housing ("FRONT" is identified). Hold the lower portion of the COLLET ASSEMBLY (1) while turning
the upper half of the COLLET ASSEMBLY (1) with the other hand. Hand tighten only to secure the FILTER HOUSING (2).
Tools are not required. Figure D.
BUMP
2
1
TURN UPPER
HALF TO
SECURE
UP
UP
UP
COLLET
ASSEMBLY
UP
Figure C.
HOLD LOWER
HALF
Figure D.
M 9 6 5 10 7
3
5
ATTACH FILTER LINES
Push the BLUE HOSE (1) into the Blue Quick Connect Union and the WHITE HOSE (2) into the White Quick Connect Union
at bottom of the FILTER HOUSING (3). HOSES (1, 2) must be fully engaged or the connection will leak.
Note: How to disconnect the HOSES (1, 2) from the FILTER HOUSING (3). Push and hold the Blue or White connector
in. While holding the connector in, pull out the Hose.
3
BLUE
UP
WHITE
PUSH HOSES UP UNTIL
FULLY ENGAGED
INTO FILTER HOUSING
UP
1
6
BLUE AND WHITE
CONNECTORS
(Push in to remove
HOSES)
2
FILTER INSTALLATION
Soak FILTER (1) in clean water for 15 minutes to saturate the FILTER (1). Insert the FILTER (1) into
the top of the FILTER HOUSING (2). FIGURE A.
NOTCH
Turn the FILTER (1) clockwise to engage the threads and continue to turn until the notch on the
FILTER (1) faces forward and is aligned with notch in the FILTER HOUSING (3) thread ring. FIGURE B.
1
Use permanent ink to mark the filter replacement date (month and day) on the INDICATOR
STICKER (6). This date should be 3 months from the date of installation. FIGURE C.
Push the SOAP DISH (4) or FILTER CAP (5) onto the FILTER HOUSING (3)
until it snaps onto the FILTER HOUSING (3) thread ring. FIGURE B.
2
Note: The Cap or Soap Dish will not snap into place unless the
Filter Cartridge is installed properly.
5
6
FIGURE A.
FIGURE B.
4
CLOCKWISE
MARK MONTH
AND DAY
FIGURE C.
1
NOTCH
IN FILTER
3
FRONT NOTCH
IN FILTER HOUSING
THREAD RING
M 9 6 5 10 7
4
7
TESTING INSTALLED FAUCET AND FILTER OPERATION
Move handle into "OFF" position and remove Aerator (1).
Turn on water supplies and check connections
for leaks.
Operate handle up and down, left and right to flush water lines thoroughly.
Move the Faucet Handle in filtered water position (handle in the off, far right position). There will be a small
resistance as the handle is moved into the filter position.
Flush to drain for 5 minutes.
Replace the aerator.
The Filter Faucet installation is now complete. Please carefully read the operation instructions to
ensure optimal performance.
HANDLE
SPOUT
OFF
1
UP
UP
FILTER
WATER
SUPPLIES
HOT
COLD
HANDLE
OPERATION
M 9 6 5 10 7
5
Operating Specifications
HANDLE
• Capacity: Streaming™ Filter has a rated service life of 250 gallons (930L)
• Pressure requirement: 20 - 125 psi (0.7 - 8.6 bar)
• Temperature: 35 - 100°F (2-38°C)
• Flow Rate: 0.70 gpm (2.65 lpg)
Water Filtering System
Faucet Operating Instructions
Water Delivery
FILTER
• The Filter Faucet provides four options for water delivery:
Unfiltered cold, mixed or hot water and Filtered cold water.
• Unfiltered water is delivered from the normal faucet Aerator.
Filtered water is delivered from the Filter Water Nozzle, which
is positioned in back of Aerator.
HOT
COLD
• COLD, FILTERED WATER:
With the Faucet handle in the closed position move the faucet
handle to the right. Push the Faucet Handle past the resistance
and filtered water will begin to flow from the Filter Water Nozzle.
Filter Cartridge Replacement
QR Code
Suggested frequency of filter replacement is every 3 months.
Replacement (F30) filters can be purchased online at www.americanstandard-us.com.
Enter “F30” in the search bar at the top and follow the ordering instructions.
OR
Scan the QR code with your web enabled smart phone to load the web page to place
order. Carrier charges may apply.
The Filter Cartridge should be left in protective film until ready for installation. The F30
Filter Cartridge is a high performance carbon based filter developed specially by
American Standard for the “streaming™ Filter Faucet”.
Note: Use only F30 Filter Cartridges with the streaming™ Filter Faucet.
How To Replace the OLD Filter with a NEW Filter
FIGURE A.
• Remove the Filter Cap or Soap Dish by lifting straight up.
• Turn the Filter counter clockwise until the filter pops out of the Filter
Housing. Discard the old Filter.
• Remove the protective wrapping from the replacement Filter Cartridge.
Important: Soak Filter in clean water for 15 minutes to saturate.
• Insert the Filter into the top of the Filter Housing.
• Turn the Filter clockwise to engage the threads and continue to turn until the
notch on the Filter faces forward and is aligned with notch in the Filter Housing
thread ring.
• Use permanent ink to mark the Filter replacement date (month and day) on the
Indicator Sticker. This date should be 3 months from the date of installation.
Refer to Step 6 in the installation instructions for more detailed information.
FIGURE B.
• Push the Filter Cap onto the Filter Housing until the Filter Cap snaps onto
the Filter Housing thread ring.
Note: The Filter Cap will not snap into place unless the Filter Cartridge is
installed properly.
• Turn the faucet handle to the filtered water position and allow filtered water to flow.
• Allow cold water to run through the new Filter to flush the system for 5 minutes.
CLOCKWISE
F30 FILTER
(Remove and replace
with new F30 Filter)
FIGURE A.
F I LT E R
HOUSING
FIGURE B.
FILTER CAP
NSF
SOAP
DISH
System Tested and Certified by NSF International against
ANSI/NSF Standard 42 for the reduction of Chlorine,
Taste and Odor, Particulate, Class I, and against ANSI/NSF
Standard 53 for the reduction of Lead.
NOTCH
IN FILTER
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
"Important Notice; Read the Manufacturer's Performance Data Sheet"
FRONT NOTCH
IN FILTER HOUSING
THREAD RING
M 9 6 5 10 7
6
SINGLE CONTROL
KITCHEN FILTER FAUCET
M962007-YYY0A
HANDLE KIT
MODEL NUMBERS
4662.002
030126-0070A
BUTTON AND SCREW KIT
M907312-YYY0A
CARTRIDGE CAP
REPLACE THE "YYY" WITH
APPROPRIATE FINISH CODE
CHROME
STAINLESS STEEL
002
075
A913877-0070A
CAP HOLDER
M961772-0070A
FILTER CLUTCH
A918585-0070A
CARTRIDGE SCREWS
M952460-0070A
STREAMING FILTER (F-30)
A954410-0070A
CARTRIDGE AND SEALS
A912746-OO7OA
MANIFOLD O-RING
M922240-YYYOA
SOAP DISH
M953325-0070A
FILTER HOUSING
M907760-YYYOA
FILTER CAP
066070-YYY0A
AERATOR
M907491-YYY0A
SINGLE HOLE
FILTER DECK PLATE
M911261-0070A
SPOUT SEAL
M962008-YYYOA
ESCUTCHEON KIT
(INCLUDES PUTTY PLATE)
A954427-0070A
COLLET ASSEMBLY
UP
M962146-0070A
MOUNTING RING KIT
M922262-0070A
*WATER BOTTLE
UP
*Note: The water bottle has not been evaluated
to the NSF/ANSI 42 and 53 standards.
M921540-0070A
“U” CONNECTOR
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
One Centennial Avenue, Piscataway, NJ 08855
1-800-442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2010
M 9 6 5 10 7
7