Download American Standard 4662.002.075 Installation Guide
Transcript
Installation Instructions 4662.002 SINGLE CONTROL KITCHEN FILTER FAUCET Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin. Certified to comply with ANSI A112.18.1M The system and installation shall comply with applicable state and local regulations. M 9 6 5 10 7 RECOMMENDED TOOLS Regular Screwdriver Phillips Screwdriver Adjustable Wrench Channel Locks All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping. UNPACKING 1. Remove the Filter Faucet items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items. FILTER HOUSING OPTIONAL FILTER CAP F30 FILTER FILTER FAUCET ASSEMBLY UP COLLET SOAP DISH *WATER BOTTLE UP ESCUTCHEON SINGLE HOLE FILTER DECK PLATE MOUNTING KIT *Note: The water bottle has not been evaluated to the NSF/ANSI 42 and 53 standards. 1 INSTALL FAUCET CAUTION 4 Turn off water at main supply. Installation with DECK ESCUTCHEON: Apply a light bead of plumbers putty to underside of ESCUTCHEON (1) if mounting surface is uneven. Figure A. Place ESCUTCHEON (1) onto sink or mounting surface. Insert all HOSES (2) and SHANK (3) through ESCUTCHEON (1) and mounting surface. Figure A. Assemble RUBBER WASHER (5), BRASS WASHER (6) and threaded LOCKNUT (7) onto SHANK (3) from underside of sink or mounting surface. Hand tighten LOCKNUT (7). Check that rotation of HANDLE (4) from HOT to COLD is centered. Figure B. FILTER HOT Ha n d le COLD t r a ve l i s c e n t e red 1 PLUMBERS PUTTY (If required) MOUNTING SURFACE 4 3 FACTORY INSTALLED SEAL Figure B. 1 2 5 6 7 2 SECURE FILTER FAUCET TO MOUNTING SURFACE Use a screwdriver to tighten SCREWS (1) on LOCKNUT (2). Work your way around LOCKNUT (2), tightening the SCREWS (1) slightly each time until all are snug to ensure even pressure. RUBBER WASHER METAL WASHER 2 1 3 CONNECT HOT AND COLD WATER SUPPLIES Turn off hot and cold water supplies before beginning. Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies. Connection on fitting supplies are 3/8" compression. Connect left supply (Red Stripe) to Hot and right supply (Blue Stripe) to the Cold wall supply. Use adjustable wrench to tighten connections. Do not over tighten. Faucet supplies are 20-1/2" long from base of faucet. Note: If longer supply length is required, installer must purchase additional parts separately. Important: If SUPPLY HOSES (1, 2) are too long, loop as illustrated to avoid kinking. LOOP SUPPLIES IF REQUIRED 20-1/2" BLUE STRIPE RED STRIPE 2 1 SUPPLY VALVES COLD HOT M 9 6 5 10 7 2 4 FILTER HOUSING INSTALLATION Remove the COLLET ASSEMBLY (1) from the FILTER HOUSING (2). Grasp the COLLET ASSEMBLY (1) and pull it down firmly from the FILTER HOUSING (2). Figure A. Place the FILTER DECK PLATE (3) over the mounting hole. Insert the FILTER HOUSING (4) into the FILTER DECK PLATE (3). The word “FRONT” should face you when installed. Figure B. Figure A. SEAL FILTER HOUSING 1 ORIENT FILTER HOUSING 4 3 BUMP UP PULL DOWN TO REMOVE COLLET ASSEMBLY (RETRACTED AGAINST STOP) STOP UP 2 UP Figure B. COLLET ASSEMBLY REMOVED UP Note: Position the COLLET ASSEMBLY (1) with the arrows pointing "up". Push the COLLET ASSEMBLY (1) back onto the FILTER HOUSING (2). Make sure the COLLET ASSEMBLY (1) is pushed above the "Bump" on the Filter Housing. Figure C. Orient the Filter Housing ("FRONT" is identified). Hold the lower portion of the COLLET ASSEMBLY (1) while turning the upper half of the COLLET ASSEMBLY (1) with the other hand. Hand tighten only to secure the FILTER HOUSING (2). Tools are not required. Figure D. BUMP 2 1 TURN UPPER HALF TO SECURE UP UP UP COLLET ASSEMBLY UP Figure C. HOLD LOWER HALF Figure D. M 9 6 5 10 7 3 5 ATTACH FILTER LINES Push the BLUE HOSE (1) into the Blue Quick Connect Union and the WHITE HOSE (2) into the White Quick Connect Union at bottom of the FILTER HOUSING (3). HOSES (1, 2) must be fully engaged or the connection will leak. Note: How to disconnect the HOSES (1, 2) from the FILTER HOUSING (3). Push and hold the Blue or White connector in. While holding the connector in, pull out the Hose. 3 BLUE UP WHITE PUSH HOSES UP UNTIL FULLY ENGAGED INTO FILTER HOUSING UP 1 6 BLUE AND WHITE CONNECTORS (Push in to remove HOSES) 2 FILTER INSTALLATION Soak FILTER (1) in clean water for 15 minutes to saturate the FILTER (1). Insert the FILTER (1) into the top of the FILTER HOUSING (2). FIGURE A. NOTCH Turn the FILTER (1) clockwise to engage the threads and continue to turn until the notch on the FILTER (1) faces forward and is aligned with notch in the FILTER HOUSING (3) thread ring. FIGURE B. 1 Use permanent ink to mark the filter replacement date (month and day) on the INDICATOR STICKER (6). This date should be 3 months from the date of installation. FIGURE C. Push the SOAP DISH (4) or FILTER CAP (5) onto the FILTER HOUSING (3) until it snaps onto the FILTER HOUSING (3) thread ring. FIGURE B. 2 Note: The Cap or Soap Dish will not snap into place unless the Filter Cartridge is installed properly. 5 6 FIGURE A. FIGURE B. 4 CLOCKWISE MARK MONTH AND DAY FIGURE C. 1 NOTCH IN FILTER 3 FRONT NOTCH IN FILTER HOUSING THREAD RING M 9 6 5 10 7 4 7 TESTING INSTALLED FAUCET AND FILTER OPERATION Move handle into "OFF" position and remove Aerator (1). Turn on water supplies and check connections for leaks. Operate handle up and down, left and right to flush water lines thoroughly. Move the Faucet Handle in filtered water position (handle in the off, far right position). There will be a small resistance as the handle is moved into the filter position. Flush to drain for 5 minutes. Replace the aerator. The Filter Faucet installation is now complete. Please carefully read the operation instructions to ensure optimal performance. HANDLE SPOUT OFF 1 UP UP FILTER WATER SUPPLIES HOT COLD HANDLE OPERATION M 9 6 5 10 7 5 Operating Specifications HANDLE • Capacity: Streaming™ Filter has a rated service life of 250 gallons (930L) • Pressure requirement: 20 - 125 psi (0.7 - 8.6 bar) • Temperature: 35 - 100°F (2-38°C) • Flow Rate: 0.70 gpm (2.65 lpg) Water Filtering System Faucet Operating Instructions Water Delivery FILTER • The Filter Faucet provides four options for water delivery: Unfiltered cold, mixed or hot water and Filtered cold water. • Unfiltered water is delivered from the normal faucet Aerator. Filtered water is delivered from the Filter Water Nozzle, which is positioned in back of Aerator. HOT COLD • COLD, FILTERED WATER: With the Faucet handle in the closed position move the faucet handle to the right. Push the Faucet Handle past the resistance and filtered water will begin to flow from the Filter Water Nozzle. Filter Cartridge Replacement QR Code Suggested frequency of filter replacement is every 3 months. Replacement (F30) filters can be purchased online at www.americanstandard-us.com. Enter “F30” in the search bar at the top and follow the ordering instructions. OR Scan the QR code with your web enabled smart phone to load the web page to place order. Carrier charges may apply. The Filter Cartridge should be left in protective film until ready for installation. The F30 Filter Cartridge is a high performance carbon based filter developed specially by American Standard for the “streaming™ Filter Faucet”. Note: Use only F30 Filter Cartridges with the streaming™ Filter Faucet. How To Replace the OLD Filter with a NEW Filter FIGURE A. • Remove the Filter Cap or Soap Dish by lifting straight up. • Turn the Filter counter clockwise until the filter pops out of the Filter Housing. Discard the old Filter. • Remove the protective wrapping from the replacement Filter Cartridge. Important: Soak Filter in clean water for 15 minutes to saturate. • Insert the Filter into the top of the Filter Housing. • Turn the Filter clockwise to engage the threads and continue to turn until the notch on the Filter faces forward and is aligned with notch in the Filter Housing thread ring. • Use permanent ink to mark the Filter replacement date (month and day) on the Indicator Sticker. This date should be 3 months from the date of installation. Refer to Step 6 in the installation instructions for more detailed information. FIGURE B. • Push the Filter Cap onto the Filter Housing until the Filter Cap snaps onto the Filter Housing thread ring. Note: The Filter Cap will not snap into place unless the Filter Cartridge is installed properly. • Turn the faucet handle to the filtered water position and allow filtered water to flow. • Allow cold water to run through the new Filter to flush the system for 5 minutes. CLOCKWISE F30 FILTER (Remove and replace with new F30 Filter) FIGURE A. F I LT E R HOUSING FIGURE B. FILTER CAP NSF SOAP DISH System Tested and Certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine, Taste and Odor, Particulate, Class I, and against ANSI/NSF Standard 53 for the reduction of Lead. NOTCH IN FILTER Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. "Important Notice; Read the Manufacturer's Performance Data Sheet" FRONT NOTCH IN FILTER HOUSING THREAD RING M 9 6 5 10 7 6 SINGLE CONTROL KITCHEN FILTER FAUCET M962007-YYY0A HANDLE KIT MODEL NUMBERS 4662.002 030126-0070A BUTTON AND SCREW KIT M907312-YYY0A CARTRIDGE CAP REPLACE THE "YYY" WITH APPROPRIATE FINISH CODE CHROME STAINLESS STEEL 002 075 A913877-0070A CAP HOLDER M961772-0070A FILTER CLUTCH A918585-0070A CARTRIDGE SCREWS M952460-0070A STREAMING FILTER (F-30) A954410-0070A CARTRIDGE AND SEALS A912746-OO7OA MANIFOLD O-RING M922240-YYYOA SOAP DISH M953325-0070A FILTER HOUSING M907760-YYYOA FILTER CAP 066070-YYY0A AERATOR M907491-YYY0A SINGLE HOLE FILTER DECK PLATE M911261-0070A SPOUT SEAL M962008-YYYOA ESCUTCHEON KIT (INCLUDES PUTTY PLATE) A954427-0070A COLLET ASSEMBLY UP M962146-0070A MOUNTING RING KIT M922262-0070A *WATER BOTTLE UP *Note: The water bottle has not been evaluated to the NSF/ANSI 42 and 53 standards. M921540-0070A “U” CONNECTOR HOT LINE FOR HELP For toll-free information and answers to your questions, call: One Centennial Avenue, Piscataway, NJ 08855 1-800-442-1902 Weekdays 8:00 a.m. to 6:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) Weekdays 8:00 a.m. to 7:00 p.m. EST IN MEXICO 01-800-839-1200 Product names listed herein are trademarks of American Standard Inc. © AS America, Inc. 2010 M 9 6 5 10 7 7