Download Orbit 37772 Installation Guide
Transcript
07WTM003045 53251-01 rE.qxd 3/2/07 2:30 PM Page 17 Installation 9 CONNECT ZONES Install Header Lines • Connect 1" pipe to each valve and run it to the assigned zone. Header Line PVC or Poly Tee PVC or Poly Cross • Use fittings (elbow, cross or tee) for each lateral line. Install Lateral Lines Fittings with Threaded Outlet • Connect 3/4" lateral lines to the header line. Lateral Line • Run lateral line to each sprinkler location. • Install Tees or Elbow at each sprinkler location. Freezing Areas – Install Line Drains 1" Male Threa Replace with Manual Drain Valve Lateral and Header Lines Canister Heads: Install an automatic drain valve in the bottom inlet of all canisters. End of Sprinkler Line: Install an automatic drain valve after the last head on the end of each sloped line. Low Spots: Install a tee and automatic drain valve for low spots on sprinkler head lines. Main Line Manifold: Remove the end cap and install a ball or gate manual drain valve. Sprinkler System Layout & Installation Guide 17