AEA2415AABS(x)_REV1 TPC - February 18, 2014 CELSEONy LOW PROFILE CONDENSING UNIT Model BOM Air Cooled Application Refrigerant Volts-Hz-Ph 11.50 AEA2415AABSK, -SB, -SC, -SS 32G326-39S, -49S, -59S, -69S 1/3 HP Low Temp R12 115-60-1 10.32 8.93 8.86 0.50 Ø0.38 10.00 16.00 Dimensions, inches (mm) Model AEA2415AABSK AEA2415AABSB AEA2415AABSC AEA2415AABSS L W H 16.0 (406) 11.5 (292) 8.9 (226) Line Connections Suction Liquid 1/4" Sweat 1/4" Sweat Pumpdown o 90% @90 F n/a AirFlow CFM 2.47 1/4" Valve Sweat 1/4" Valve Sweat Oil Ch. Oz. Gross weight Lbs (kg) 10 40.6 (18.4) 41.2 (18.7) 42.0 (19.0) 41.4 (18.8) 190 n/a Factory charge 20 PSIG dry air, MUST BE EVACUATED Ambient Temps Evaporator T, °F -40 -30 -25 -20 -15 -10 -5 0 5 10 PSIG *11.0" *5.5" *1.4" 0.7 2.6 4.7 6.9 9.3 11.9 14.8 BTUH 820 1100 1270 1450 1640 1850 2070 2310 2570 2840 80°F Watts Head 320 100 360 105 380 107 400 110 430 114 460 118 480 122 510 126 540 131 580 137 o Cond T 90 93 94 96 98 100 103 105 108 110 o Performance @ 60 Hz, Return gas 40 F, SubCooling 5 F Note: *= Inches of Mercury below 1 Atmosphere BTUH 590 920 1100 1290 1500 1720 1950 2190 2440 2710 90°F Watts Head 310 115 350 120 380 123 410 127 430 131 460 135 490 140 520 145 560 150 590 156 Cond T 99 102 103 105 107 109 112 114 117 119 BTUH 480 830 1020 1220 1430 1660 1890 2140 2400 2680 100°F Watts Head 290 132 350 139 380 143 410 147 440 151 470 155 500 160 530 165 560 170 590 175 Cond T 108 111 113 115 117 119 121 123 126 128 BTUH 380 730 920 1120 1330 1550 1780 2020 2280 2540 110°F Watts Head 280 150 340 157 370 161 400 166 440 171 470 176 500 182 540 188 570 194 600 201 Cond T 117 120 122 124 126 128 130 133 135 138 AEA2415AABS(x)_REV1 TPC - February 18, 2014 Parts/Specifications Unit BOM Unit MODEL 32G326-39S AEA2415AABSK Refrigerant Refrigeration RANGE Design Pressure Low Design Pressure High Volts - HZ - Ph Voltage Range Min. Circuit Ampacity Max. Fuse Size R12 -40°F to 10°F 150 300 115V ~ 60HZ 103.5 - 126.5 8.08 15 Compressor MODEL Compressor BOM Compressor LRA Compressor RLA AEA2415AAB AE334AR-944-J7JM 40 6 OverLoad Replacement Kit - O/L Relay Replacement Kit - Relay Run Capacitor Run Capacitor Rating Start Capacitor Start Capacitor Rating 8300MRTD88 K90-17 820RR12B79 K71-01 85PS110C92 270-324 MFD 110V Unit drawing DGU Electrical Diagram DGU1896-G406 DEAE-10 Condenser Shroud Fan Guard Condenser, Fan Guard Kit Power Cord 506-G434 116-002P K135-02 85106-10 Fan Motor Fan Motor RLA Fan Blade Replacement Fan Motor NUT6B09PUN301 0.58 4VEA010 9W115 Fan Motor, Blade, Guard assy GFBG-109 Unit BOM Unit MODEL Liquid Receiver 32G326-49S AEA2415AABSB 51085-1 Unit BOM Unit MODEL Liquid Receiver Liquid Valve Suction Valve 32G326-59S AEA2415AABSC 51085-1 56605 56605 Unit BOM Unit MODEL Liquid Valve Suction Valve 32G326-69S AEA2415AABSS 56605 56605