Download Rolls RPB486 User's Manual

Transcript
LIMITED WARRANTY
This product is warranted to the original consumer purchaser to be free from
defects in materials and workmanship under normal installation, use and service for a
period of one (1) year from the date of purchase as shown on the purchaser’s receipt.
The obligation of Rolls Corporation under this warranty shall be limited to
repair or replacement (at our option), during the warranty period of any part which proves
defective in material or workmanship under normal installation, use and service, provided
the product is returned to Rolls Corporation, TRANSPORTATION CHARGES PREPAID. Products returned to us or to an authorized Service Center must be accompanied
by a copy of the purchase receipt. In the absence of such purchase receipt, the warranty
period shall be one (1) year from the date of manufacture.
This warranty shall be invalid if the product is damaged as a result of defacement, misuse, abuse, neglect, accident, destruction or alteration of the serial number,
improper electrical voltages or currents, repair, alteration or maintenance by any person
or party other than our own service facility or an authorized Service Center, or any use
violative of instructions furnished by us.
This one-year warranty is in lieu of all expressed warranties, obligations or liabilities. ANY IMPLIED WARRANTIES, OBLIGATIONS, OR LIABILITIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIMITED IN
DURATION TO THE ONE YEAR DURATION OF THIS WRITTEN LIMITED WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so
RPB486
PHANTOM HEX
6 CHANNEL PHANTOM
POWER SUPPLY
the above limitation may not apply to you.
IN NO EVENT SHALL WE BE LIABLE FOR ANY SPECIAL, INCIDENTAL
OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, WHATSOEVER. Some states do not allow the
exclusion or limitation of special, incidental or consequential damages so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights which vary from state to state.
ROLLS CORPORATION
SALT LAKE CITY, UTAH
6/00
OWNERS MANUAL
INTRODUCTION
INSTALLATION
Thank you for your purchase of the ROLLS RPB486 PHANTOM HEX 6 channel
phantom power supply. This unit powers up to 6 condenser microphones with 48
volts of ultra clean phantom power. The outputs are 1/4” Tip-Ring-Sleeve balanced for easy connection to a digital multi-track recorder.
To eliminate the possibility of any DC voltages, the RPB486 features pull-down
resistors and isolation capacitors on all outputs.
Mount the RPB486 in a sturdy rack. Connect microphones to properly shielded
balanced cable, and connect the cable to the Input channels of the RPB486.
Connect the outputs of the RPB486 to the recording or mixing device.
The output impedance of the RPB486 will be the same as the impedance of your
microphone.
DESCRIPTION
The green LED for each channel lights when that channel is in use. All these
LEDs light momentarily when the RPB486 is powered up.
SCHEMATIC
2
The red PWR led indicates the unit is on.
Important notice!
The RPB486 should be powered up and connected to the
microphones before power is applied to the power amplifiers
or recording device. A noticeable thump sound will be heard if
power amps are on before the RPB486 is powered up.
REAR PANEL
XLR JACK FĐ
J1Đ
J2Đ
PHONE 1/4Đ
C1Đ 47UFĐ
2
FRONT PANEL
Đ
3Đ
XLR JACK FĐ
J1AĐ
Đ
+48VĐ
1
R3Đ
100Đ
6.8KĐ
47UFĐ
J2AĐ
C3AĐ
47UFĐ
R7Đ
100Đ
Đ
C6Đ
1N4001Đ
C1EĐ47UFĐ
J2EĐ
PHONE 1/4Đ
6.8KĐ
C2EĐ
47UFĐ
R4EĐ
R1EĐ100KĐ
6.8KĐ
R5EĐ
100KĐ
+48VĐ
Đ
IĐ
OĐ
47UFĐ
R11Đ
100Đ
D7Đ
LDLGĐ
3Đ
G
1Đ
7812Đ
U1Đ
2
Đ
MCI 407 4024Đ
AC PLUGĐ
D1Đ
XLR JACK FĐ
J1EĐ
D8Đ
LDLGĐ
C4Đ
470UFĐ
D6Đ POWERĐ
LDSRĐ
Đ
AC1Đ
+48VĐ
C3EĐ
D10Đ
LDLGĐ
C5Đ
470UFĐ
2Đ
R10Đ
100Đ
Đ
+48VĐ
1
1
Đ
19” x 1.75” x 2.5” (48 x 4.5 x 12.7)
4 lbs.
SW SPSTĐ
Đ
Size (W x H x D):
Weight:
D2Đ
1N4001Đ
47UFĐ
R2EĐ
+48VĐ
T1Đ
1
Phantom Power Voltage:
Max Phantom Power Current:
Power Supply:
6 ea. XLR female jacks (pin 2 hot)
6 ea. 1/4” TRS jacks (tip positive)
48 Volts
14 mA each channel
Linear 120VAC 50/60Hz
3
SW3Đ
Đ
SPECIFICATIONS
Connectors:
R8Đ
100Đ
R5DĐ
100KĐ
3Đ
R5BĐ
100KĐ
C3BĐ
47UFĐ
C2DĐ
47UFĐ
R4DĐ
R1DĐ100KĐ
6.8KĐ
6.8KĐ
PHONE 1/4Đ
C1BĐ47UFĐ
C2BĐ
47UFĐ
R5BĐ
R1BĐ100KĐ
6.8KĐ
6.8KĐ
J2DĐ
PHONE 1/4Đ
C1DĐ47UFĐ
Đ
J2BĐ
3Đ
R2BĐ
D9Đ
LDLGĐ
C3DĐ
D11Đ
LDLGĐ
2
XLR JACK FĐ
J1BĐ
XLR JACK FĐ
J1DĐ
R2DĐ
+48VĐ
1
6.8KĐ
+48VĐ
3Đ
R5AĐ
100KĐ
Đ
Đ
2
Đ
1
NOTE: THE FOLLOWING DESCRIPTION APPLIES TO EACH OF THE SIX
CHANNELS.
INPUT: Female balanced XLR jack - for connection to the condenser microphone.
Pin 2 is hot. This jack carries the 48 volts of phantom power to the microphone.
OUTPUT: 1/4” Tip-Ring-Sleeve balanced jack - for connection to a mixer or multitrack recorder. Note: If you are connecting this to a mixer, adjust the mixer’s gain
or trim control carefully for a suitable input level.
R9Đ
100Đ
PHONE 1/4Đ
C1AĐ47UFĐ
C2AĐ
47UFĐ
R5AĐ
R1AĐ100KĐ
6.8KĐ
R5CĐ
100KĐ
C3CĐ
D12Đ
LDLGĐ
3Đ
R2AĐ
C2CĐ
47UFĐ
R4CĐ
R1CĐ100KĐ
6.8KĐ
R2CĐ
Đ
C3Đ
47UĐ
R5Đ
100KĐ
2
1
Đ
2
120 VAC 50/60 HZ 15 VA: Power Cord. Connect to a properly grounded AC
source.
6.8KĐ
J2CĐ
PHONE 1/4Đ
C1CĐ47UFĐ
3Đ
C2Đ
47UFĐ
R4Đ
R1Đ 100KĐ
6.8KĐ
R2Đ
XLR JACK FĐ
J1CĐ
D3Đ
ZD12VĐ
ROLLS CORPORATIONĐ
5968 South 350 WestĐ
Murray, UT 84107Đ
503Đ
D5Đ
ZD12VĐ
D4Đ
ZD12VĐ
P H A NRPB486
TOM HEX RPB623Đ
Rev:Đ
Size:Đ Document Number:Đ
BaĐ
RPB623.SCHĐ
AĐ
S h e e t1Đ o f 1 Đ