Transcript
SALES FACT SHEET Features Includes an energy efficient GE® ECM® Motor, which in most applications, enhances the SEER rating of the outdoor unit. It also slowly ramps its speed up for quiet operation and enhanced customer satisfaction. ■ Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications. ■ Nominal airflow up to 1.0" external static pressure. ■ Factory-installed high efficiency indoor coil. ■ Sturdy cabinet construction with 1.0 inch [25.4 mm] of foil faced insulation for excellent sound and insulating characteristics. ■ Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet U.L. and cUL requirements for service disconnect. ■ Dip switch settings for selectable, customized cooling airflow over a wide variety of applications. ■ On-demand dehumidification terminal that adjusts airflow to help control humidity for unsurpassed comfort in cooling mode. ■ RHKA- SERIES featuring R-22 Refrigerant RHKL- SERIES featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Indoor Coils leaks caused by factory defects . . . . . . . . . . . . . .Five (5) Years Electric Heating Element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Five (5) Years *Any Other Part . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Five (5) Years *For complete details of the limited warranty, including applicable terms & conditions, see your local installer or contact the manufacturer for a copy. Starting at: Price $ — R H K A RHEEM CLASSIFICATION K = PREMIUM REFRIGERANT A = R-22 L = R-410A H= AIR HANDLER HM A* VARIATIONS24 A/C OR HP A = STANDARD CAPACITY MULTI24 = 18,000/24,000 BTU/HR POSITION [5.27/7.03 kW] (VERTICAL 36 = 30,000/36,000 BTU/HR UPFLOW/ HORIZONTAL [6.79/10.55 kW] LEFT IS THE 48 = 42,000/48,000 BTU/HR FACTORY [12.31/14.07 kW] CONFIGURATION) 60 = 60,000 BTU/HR [17.58 kW] 17 J A CABINET SIZE VOLTAGE DESIGN VARIATION J = 208/240/1/60 17 = 17.5" [431.8 mm] (800-1200 CFM) 21 = 21" [533.4 mm] (1400-1600 CFM) 24 = 24.5" [609.6 mm] (1600-1800 CFM) A = 1ST DESIGN “CERTIFIED UNDER THE A.R.I. CERTIFICATION PROGRAM—A.R.I. STANDARDS 210/240-84” RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 PRINTED IN U.S.A. DC FORM NO. H11-523-SFS 12-05