Table C. Troubleshooting with Front-Panel Indicators (Continued)
Indicator Color
Not lit
Green
Amber
Flashing amber
Red
Meaning
Possible Cause
Corrective Action
Fiber Failover Mode LED ( )
The module is not in The FX Mode switch is set
to position 0.
fiber redundancy
mode.
The module is in
fiber redundancy
mode. The primary
fiber link is
operational. The
secondary fiber link
is idle.
The module is in
fiber redundancy
mode. The primary
fiber link is
operational. The
secondary fiber link
is down.
The module is in
fiber redundancy
mode. The primary
fiber link is down.
The secondary fiber
link is operational.
The module is in
fiber redundancy
mode; however, both
primary and
secondary fiber links
are down.
If fiber redundancy is not
required, no action is
required. If fiber redundancy
is required, power off the
module, set the FX Mode
switch to position 1 or 2 as
appropriate, and then power
on the module. For detailed
information, refer to the
Setting Fiber Failover Mode
section.
The FX Mode switch is set If fiber redundancy is
required, no action is
to position 1 (port A
required. If fiber redundancy
connects to the primary
is not required, power off the
fiber link) or to position 2
module, set the FX Mode
(port B connects to the
switch to position 0, and
primary fiber link).
then power on the module.
Refer to the Optic Fault LED
A problem exists with the
section or to the 100BASE-FX
secondary fiber link. The
Status LED section in this
Optic Fault LED or the
100BASE-FX Status LED for table as appropriate.
port A or port B is red.
A problem exists with the
primary fiber link. The Optic
Fault LED or the
100BASE-FX Status LED for
port A or port B is red.
Refer to the Optic Fault LED
section or to the 100BASE-FX
Status LED section in this
table as appropriate.
A problem exists with the
primary and backup fiber
links. The Optic Fault LEDs
or the 100BASE-FX Status
LEDs for ports A and B are
red.
Refer to the Optic Fault LED
section or to the 100BASE-FX
Status LED section in this
table as appropriate.
(Continued on next page)
C2624M (6/07)