Split System Submittal Data System: KS18NB4UA Indoor: CS-KS18NB4UW Outdoor: CU-KS18NKUA Ceiling Recessed Heat Pump Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit#: Drawing#: General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A) 230/208/1/60 15 15 Compressor No. Used R.L. Amps - L.R. (A) DC Twin Rotary (Inverter) 1 8.3 ( 1.2 to 8.3 )-(17.5) Outdoor Unit Fan Type Dia (in.) - No. Speeds Type Drive No. Poles (RPM) No. Motors (W) F.L. Amps (A) Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in.) Propeller 16-17/32”-Auto (Hi and multi steps) DC Motor 8-820 1-50 0.5 Aluminum Fin and Copper Pipe Corrugated Plate - Inner Rifled 2-21.2 5.49 9/32” Indoor Unit Fan Type Diameter and Depth No. Speeds No. Poles (RPM, High) No. Motors (W) CFM (Hi/Med/Low) Operation Sound (Hi/Med/Low) (dB-A) F.L. Amps Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq. ft.) Tube Size (in.) Drain tube connection, VP20(in.) Refrigerant Lbs. - R410a (outdoor unit) Turbo 12-5/8” x 5-3/4” Auto and 3 steps 8-650 1-20 341 / 294 / 253 44 / 40 / 36 0.3 Aluminum Plate Fin & Copper Tube Slit Plate - Inner Rifled 2-18.1 2.94 9-32” (outer dia.1”) R410A 2.87 Refrigerant Control Refrigerant Tubing Connections Line Length, Max (ft.) Line Heigth Difference, Max (ft.) Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction) Pre-charge, tubing length at shipment Electronic Expansion Valve Flare 100’ 50’ 1/4” 1/2” 25’ Dimensions (HxWxD) Indoor Unit (Crated) (in.) Indoor Unit (Uncrated) (in.) Outdoor Unit (Crated) (in.) Outdoor Unit (Uncrated) (in.) 11-13/32” x 24-13/16” x 28-1/8” 11-5/32” x 22-5/8” x 22-5/8” 29-1/8” x 39-27/32” x 14-31/32” 26-3/8” x 34-21/32” x 11-7/32” Weight (lbs.) (Indoor) Net (Indoor) Shipping (Outdoor) Net (Outdoor) Shipping 35.3 41.9 90.4 99.2 (Indoor) Shipping Volume (cu.ft.) (Outdoor) Shipping Volume (cu.ft.) 4.59 9.88 Performance Data @ ARI Standard Conditions (230/208V) Cooling Total Capacity (BTU/H) Sensible Capacity (BTU/H) Latent Capacity (BTU/H) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (W) Outdoor Sound Rating (dB-A) 17,500 (4,000-17,500) 10,600 6,900 16 4.89 8.3 (1.2-8.3) 1860 (250-1860) 51 Features Controls Remote Controller Temperature Control Timer Night Setback Panel, No.of Louvers, Control Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon Microprocessor LCD Wireless Type, Temp. Sensor Built In IC Thermistor 24 Hour, Single Event, ON/OFF Timer Included (CZ-18BT1U)-4-Automatic/ Sweep/Step Power Failure Automatic Restart Self-Diagnosis Air Filter Quiet Operation Condensate Drain Pump High Power One Hour Off Timer Included Included Washable, Anti-Mold Included Included Included Included Options Refrigerant Line Set Fresh Air Intake Air Duct Extension Hard Wired Remote Control Non-Removable, Locking Remote-Control Bracket Available Knock-Out (Dia. 3-7/8”) N/A Available / Model Number-CZRD515U RCS4MHVB Operating Range Indoor Air Intake Temp Outdoor Air Intake Temp Cooling (Max) Cooling (Min) Low Ambient Control Included 95F DB/71F WB 67F DB/57F WB 115F DB 0F DB Indoor Dimensions Refrigerant tubing (gas tube) dia. 1/2" (flared) 12-7/8 Fresh air intake duct connection port (dia. 3-7/8") 22-5/8 (575) 2-3/32 6-5/16 6-11/16 22-5/8 (575) 8-15/32 6 1-3/16 (30) 4-19/32 1-25/32 3-5/8 Less than 31/32 3 2 2 13-5/32 (334) 25/32 2 1 2-3/4 5-9/16 7-23/32 Unit : inch (mm) 1-27/32 1-9/32 24-19/32 (625) 14-3/32 (358) 2-3/32 1-3/32 Outdoor Unit CU-KE18NKU A View 5 1-25/32 18 Less than 31/32 2 The length of the suspension bolts should be selected so that there is a gap of 1-3/16" or the ceiling (21/32" or more below the lower surface of the main unit), as shown in the figure at right. If the suspension bolts is too long, it will contact the ceiling panel and the unit cannot be installed. Outdoor Dimensions 15/32 5/ 16 5-11/32 ID :1 3/ :2 13-5/32 Wide tube service valve dia.1/2" (12.70) 2-17/32 Narrow tube service valve dia.1/4" (6.35) 6-17/32 4-3/8 23/32 2-5/32 26-3/8(670) 34-21/32(880) 12-7/32 11-7/32(285) 4- ID 1-3/8 11-17/32 32 23-15/16 3/32 1-13/16 5-23/32 2-13/32 Unit : inch (mm) (852-0-0010-13200-0) Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon 20 8 1-3/16 Suspension bolt hole (4 - 1/2" x 1-1/8" hole) 4-29/32 3-1/8 21/32 Power supply port 24-19/32 (625) Drain tube connection port VP20 (outer dia. 1") 7-11/16 Center of panel 7 Refrigerant tubing (liquid tube) dia. 1/4" (flared) 12-7/16 21-1/32 (534) Suspension bolt pitch 23-5/8 (600) Ceiling opening dimensions Discharge outlet 11-5/32 (283) Air intake CS-KE12NB41 & CZ-18BT1U CS-KE18NB4UW & CZ-18BT1U 1 2 3 4 5 6 7 8 3. DIMENSIONAL DATA Indoor Unit A 23-5/8 (600) Ceiling opening dimensions 21-1/32 (534) Suspension bolt pitch