Download Panasonic KE30NKUA Data Sheet

Transcript
Split System Submittal Data
System: KE30NKU Indoor: CS-KE36NKU Outdoor: CU-KE36NKU
Wall Mounted Heat Pump
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Approval:
Date:
Construction:
Unit#:
Drawing#:
General Data
Power (V/P/Hz)
Circuit Ampacity (A)
Fuse Size, Max.(A)
230/208/1/60
16.5-18.0
35
Compressor
No. Used
R.L. Amps - L.R. (A)
DC Twin Rotary (Inverter)
1
16.5-31.0
Outdoor Unit
Fan Type
Dia (in.) - No. Speeds
Type Drive
No. Poles (RPM)
No. Motors (W)
F.L. Amps (A)
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Propeller
19-9/32” Auto (Hi, Me, Lo)
Direct / DC Motor
8-750
1-142
17.6/16.1
Aluminum Fin and Copper Pipe
Slit Plate - Inner Rifled
2-21.2
8.05
3/8”
Indoor Unit
Fan Type
Dia (in.)
No. Speeds
No. Poles (RPM (Cool / Heat), High)
No. Motors (W)
CFM (Hi/Med/Low) Cooling
CFM (Hi/Med/Low) Heating
Operating Sound-Hi/Me/Lo/ dB-A
(Cool)
Operating Sound-Hi/Me/Lo/ dB-A
(Heat)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq. ft.)
Tube Size (in.)
Drain Connection Size (in.)
Cross Flow
3-15/16” x 32”
Auto and 3 steps
8-1,370 / 1,450
47
630/530/412
671/559/441
49 / 44 / 39
49 / 44 / 39
0.4
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Rifled
2-19.5
4.55
3/8”
1-1/4”
Refrigerant
Lbs. - R410a (outdoor unit)
Refrigerant Control
Refrigerant Tubing Connections
Line Length, Max (ft.)
Line Difference, Max (ft.)
Line Size (in. O.D. Discharge)
Line Size (in. O.D. Suction)
Pre-charge, tubing length at
shipment
R410A
6.5
Electronic Expansion Valve
Flare
165
50 (outdoor lower), 100 (outdoor
higher)
3/8”
5/8”
100’
Dimensions (HxWxD)
Indoor Unit (Crated) (in.)
Indoor Unit (Uncrated) (in.)
Outdoor Unit (Crated) (in.)
Outdoor Unit (Uncrated) (in.)
12-7/32 x 44-7/8 x 14-31/32
11-3/16 x 41-15/16 x 9-1/16
42-3/8 x 40 x 16-3/8
35-13/16 x 37-1/32 x 13-3/8
Weight (lbs.)
(Indoor) Net
(Indoor) Shipping
(Outdoor) Net
(Outdoor) Shipping
32.0
39.7
185.2
207.2
(Indoor) Shipping Volume (cu.ft.)
(Outdoor) Shipping Volume (cu.ft.)
4.59
15.88
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
Total Capacity (BTU/H)
Sensible Capacity (BTU/H)
Latent Capacity (BTU/H)
SEER
Dehumidification (Pints/H)
Amps (A)
Power Inputs (W)
Outdoor Sound Rating (dB-A)
36,000 (10,900-30,600)
18,600
12,000
16
9.57
5-18
3,290
55
Heating
Total Capacity (BTU/H)
HSPF
Amps (A)
Max Amps
Power Inputs (W)
Outdoor Sounds Rating (dB-A)
33,000 (14,000-33,000)
9,0
4.5-16.3
15.3/16.8
3,070/3,070
55
Features
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Unoccupied Mode
High Power
One Hour Timer
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon
Microprocessor
LCD Wireless Type, Temp. Sensor
Built In
IC Thermistor
24 Hour, Single Event, ON/OFF
Timer
Included
Included
Included
Included
Air Louver, Horizontal
Air Louver, Vertical
Power Failure Automatic Restart
Heating/Cooling Automatic
Changeover
Self-Diagnosis
Air Filter
Manual
Automatic, Sweep, Step
Included
Included
Included
Washable, Anti-Mold
Options
Refrigerant Line Set
Fresh Air Intake
Air Duct Extension
Hard Wired Remote Control
Indoor Frame Extension
Condensate Drain Pump
Non-Removable, Locking
Remote-Control Bracket
Available
N/A
N/A
Available / Model Number-CZRD515U
N/A
Available
Available
Operating Range
Indoor Air Intake Temp
Outdoor Air Intake Temp
Cooling (Max)
Cooling (Min)
Heating (Max)
Heating (Min)
95F DB/71F WB
67F DB/57F WB
80F DB/67F WB
-DB/-WB
115F DB
0F DB
75F DB/65F WB
0F DB
Indoor Dimensions
2-3/4
7-23/32
4-9/16
2-3/8
7-25/32
(3/32)
Wide tube dia. 5/8" (15.88)
15-1/8
9-3/32
17-23/32
3-3/4
7-7/8
1-15/32
23/32
16-11/32
a.
3-
5/
32
6-7/32
17-5/16
di
5-3/16
16-11/32
17-21/32
19-9/16
22-3/8
Outdoor Dimensions
6-11/6
2-ID:1-1/4 holes (holes1/2
for drain)
Of the 4-ID:1-1/4 holes, use 1 of 2 holes
specified for drain use to install the port.
Use rubber plugs to seal the remaining 3 holes.
2-3/8
16-5/32
16-5/32
14-31/32
13/32
13-3/8 (340)
11-13/32
11-13/32
1-1/32
1-1/32
1/2
14-31/32
25-31/32
8-5/8 2-15/16 2-15/16
13/32
4-1/8
2-ID:1-1/4 holes (holes for drain)
Of the 4-ID:1-1/4 holes, use 1 of 2 holes
specified for drain use to install the port.
Use rubber plugs to seal the remaining 3 holes.
2-3/8
13-3/8 (340)
6-11/6
4-11/32
25-31/32
8-5/8 2-15/16 2-15/16
4-1/8
4-11/32
1/2
1/2
37-1/32 (940)
Refrigerant tubing joint (Liquid tube)
Flare connection dia.3/8" (9.52)
37-1/32 (940)
Refrigerant tubing joint (Liquid tube)
Flare connection dia.3/8" (9.52)
Wiring outlet
(knock-out holes
dia.1-3/8, 1-3/32, 7/8, 1/2)
Panasonic North America
Air Conditioning Division
1690 Roberts Blvd., NW, Suite 110
Kennesaw, GA 30144
us.panasonic.com/aircon
2-17/32
2-17/32
2-3/8
3/4
3-3/8
2-17/32
Wiring outlet
(knock-out holes
dia.1-3/8, 1-3/32, 7/8, 1/2)
3-3/8
3/4
1-3/16
2-17/32
7/16
2-5/32
Wiring outlet
(knock-out holes
dia.1-3/8, 1-3/32, 7/8, 1/2)
21/32
31/32
4-3/4
1-3/16
19/32
6-23/32
1-27/32
2-3/8
1-15/16
2-25/32
4-3/4 4-11/3231/32
21/32
1-3/16
19/32
6-23/32
1-27/32
1-15/16
1-3/16
13-9/32
14-11/32
2-25/32
1-15/16
4-11/32
14-11/32
13-9/32
1-27/32
1-3/16
4-11/32
Wiring outlet
(knock-out holes
dia.1-3/8, 1-3/32, 7/8, 1/2)
2-3/8
2-5/32
2-25/32
2-3/8
2-5/32
1-15/16
3/4
2-25/32
23/32
23/32
3/4
4-11/32
1-27/32
35-13/16 (910)
35-13/16 (910)
Refrigerant tubing joint (Gas tube)
Flare connection dia.5/8" (15.88)
Refrigerant tubing joint (Gas tube)
Flare connection dia.5/8" (15.88)
1-3/16
7/16
2-5/32
1-7/8
11-13/16
3-3/8
2-5/8
2-5/8
3-3/4
1-7/8
2-3/8
5-1/2
7/16
5-27/32
Narrow tube dia. 3/8" (9.52)
2-11/16
9-1/16 (230)
1-3/32
4-9/16
11-13/16 (300)
1-27/32
25/32
1-9/32
2-3/32
5-9/16
41-15/16 (1065)
dia
.3
-5/
32