Download Panasonic KE30NKUA Data Sheet
Transcript
Split System Submittal Data System: KE30NKU Indoor: CS-KE36NKU Outdoor: CU-KE36NKU Wall Mounted Heat Pump Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit#: Drawing#: General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A) 230/208/1/60 16.5-18.0 35 Compressor No. Used R.L. Amps - L.R. (A) DC Twin Rotary (Inverter) 1 16.5-31.0 Outdoor Unit Fan Type Dia (in.) - No. Speeds Type Drive No. Poles (RPM) No. Motors (W) F.L. Amps (A) Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in.) Propeller 19-9/32” Auto (Hi, Me, Lo) Direct / DC Motor 8-750 1-142 17.6/16.1 Aluminum Fin and Copper Pipe Slit Plate - Inner Rifled 2-21.2 8.05 3/8” Indoor Unit Fan Type Dia (in.) No. Speeds No. Poles (RPM (Cool / Heat), High) No. Motors (W) CFM (Hi/Med/Low) Cooling CFM (Hi/Med/Low) Heating Operating Sound-Hi/Me/Lo/ dB-A (Cool) Operating Sound-Hi/Me/Lo/ dB-A (Heat) F.L. Amps Coil Type Fin Type - Pipe Type Rows - F.P.I. Face Area (sq. ft.) Tube Size (in.) Drain Connection Size (in.) Cross Flow 3-15/16” x 32” Auto and 3 steps 8-1,370 / 1,450 47 630/530/412 671/559/441 49 / 44 / 39 49 / 44 / 39 0.4 Aluminum Plate Fin & Copper Tube Slit Plate - Inner Rifled 2-19.5 4.55 3/8” 1-1/4” Refrigerant Lbs. - R410a (outdoor unit) Refrigerant Control Refrigerant Tubing Connections Line Length, Max (ft.) Line Difference, Max (ft.) Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction) Pre-charge, tubing length at shipment R410A 6.5 Electronic Expansion Valve Flare 165 50 (outdoor lower), 100 (outdoor higher) 3/8” 5/8” 100’ Dimensions (HxWxD) Indoor Unit (Crated) (in.) Indoor Unit (Uncrated) (in.) Outdoor Unit (Crated) (in.) Outdoor Unit (Uncrated) (in.) 12-7/32 x 44-7/8 x 14-31/32 11-3/16 x 41-15/16 x 9-1/16 42-3/8 x 40 x 16-3/8 35-13/16 x 37-1/32 x 13-3/8 Weight (lbs.) (Indoor) Net (Indoor) Shipping (Outdoor) Net (Outdoor) Shipping 32.0 39.7 185.2 207.2 (Indoor) Shipping Volume (cu.ft.) (Outdoor) Shipping Volume (cu.ft.) 4.59 15.88 Performance Data @ ARI Standard Conditions (230/208V) Cooling Total Capacity (BTU/H) Sensible Capacity (BTU/H) Latent Capacity (BTU/H) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (W) Outdoor Sound Rating (dB-A) 36,000 (10,900-30,600) 18,600 12,000 16 9.57 5-18 3,290 55 Heating Total Capacity (BTU/H) HSPF Amps (A) Max Amps Power Inputs (W) Outdoor Sounds Rating (dB-A) 33,000 (14,000-33,000) 9,0 4.5-16.3 15.3/16.8 3,070/3,070 55 Features Controls Remote Controller Temperature Control Timer Night Setback Unoccupied Mode High Power One Hour Timer Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon Microprocessor LCD Wireless Type, Temp. Sensor Built In IC Thermistor 24 Hour, Single Event, ON/OFF Timer Included Included Included Included Air Louver, Horizontal Air Louver, Vertical Power Failure Automatic Restart Heating/Cooling Automatic Changeover Self-Diagnosis Air Filter Manual Automatic, Sweep, Step Included Included Included Washable, Anti-Mold Options Refrigerant Line Set Fresh Air Intake Air Duct Extension Hard Wired Remote Control Indoor Frame Extension Condensate Drain Pump Non-Removable, Locking Remote-Control Bracket Available N/A N/A Available / Model Number-CZRD515U N/A Available Available Operating Range Indoor Air Intake Temp Outdoor Air Intake Temp Cooling (Max) Cooling (Min) Heating (Max) Heating (Min) 95F DB/71F WB 67F DB/57F WB 80F DB/67F WB -DB/-WB 115F DB 0F DB 75F DB/65F WB 0F DB Indoor Dimensions 2-3/4 7-23/32 4-9/16 2-3/8 7-25/32 (3/32) Wide tube dia. 5/8" (15.88) 15-1/8 9-3/32 17-23/32 3-3/4 7-7/8 1-15/32 23/32 16-11/32 a. 3- 5/ 32 6-7/32 17-5/16 di 5-3/16 16-11/32 17-21/32 19-9/16 22-3/8 Outdoor Dimensions 6-11/6 2-ID:1-1/4 holes (holes1/2 for drain) Of the 4-ID:1-1/4 holes, use 1 of 2 holes specified for drain use to install the port. Use rubber plugs to seal the remaining 3 holes. 2-3/8 16-5/32 16-5/32 14-31/32 13/32 13-3/8 (340) 11-13/32 11-13/32 1-1/32 1-1/32 1/2 14-31/32 25-31/32 8-5/8 2-15/16 2-15/16 13/32 4-1/8 2-ID:1-1/4 holes (holes for drain) Of the 4-ID:1-1/4 holes, use 1 of 2 holes specified for drain use to install the port. Use rubber plugs to seal the remaining 3 holes. 2-3/8 13-3/8 (340) 6-11/6 4-11/32 25-31/32 8-5/8 2-15/16 2-15/16 4-1/8 4-11/32 1/2 1/2 37-1/32 (940) Refrigerant tubing joint (Liquid tube) Flare connection dia.3/8" (9.52) 37-1/32 (940) Refrigerant tubing joint (Liquid tube) Flare connection dia.3/8" (9.52) Wiring outlet (knock-out holes dia.1-3/8, 1-3/32, 7/8, 1/2) Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon 2-17/32 2-17/32 2-3/8 3/4 3-3/8 2-17/32 Wiring outlet (knock-out holes dia.1-3/8, 1-3/32, 7/8, 1/2) 3-3/8 3/4 1-3/16 2-17/32 7/16 2-5/32 Wiring outlet (knock-out holes dia.1-3/8, 1-3/32, 7/8, 1/2) 21/32 31/32 4-3/4 1-3/16 19/32 6-23/32 1-27/32 2-3/8 1-15/16 2-25/32 4-3/4 4-11/3231/32 21/32 1-3/16 19/32 6-23/32 1-27/32 1-15/16 1-3/16 13-9/32 14-11/32 2-25/32 1-15/16 4-11/32 14-11/32 13-9/32 1-27/32 1-3/16 4-11/32 Wiring outlet (knock-out holes dia.1-3/8, 1-3/32, 7/8, 1/2) 2-3/8 2-5/32 2-25/32 2-3/8 2-5/32 1-15/16 3/4 2-25/32 23/32 23/32 3/4 4-11/32 1-27/32 35-13/16 (910) 35-13/16 (910) Refrigerant tubing joint (Gas tube) Flare connection dia.5/8" (15.88) Refrigerant tubing joint (Gas tube) Flare connection dia.5/8" (15.88) 1-3/16 7/16 2-5/32 1-7/8 11-13/16 3-3/8 2-5/8 2-5/8 3-3/4 1-7/8 2-3/8 5-1/2 7/16 5-27/32 Narrow tube dia. 3/8" (9.52) 2-11/16 9-1/16 (230) 1-3/32 4-9/16 11-13/16 (300) 1-27/32 25/32 1-9/32 2-3/32 5-9/16 41-15/16 (1065) dia .3 -5/ 32