Download Lightolier Lytecel LI User's Manual
Transcript
Lytecel LI / LC 45 Industrial Way, Wilmington, MA 01887 (978) 657-7600 • Fax (978) 658-0595 We reserve the right to change details of design, materials and finish. www.lightolier.com This product may have a mercury containing lamp. Manage in accordance with Disposal Laws. See: www.lamprecycle.org 1 3 Installation Instructions Standard or Slot Grid Ceiling Systems ACCESS PLATE Access Plate Remove Access Plate by 1. sliding Access Plate in the Access Access Plate direction of Arrow 1. To re- Plate Opening move, lift up and slide in Opening the direction of Arrow 2. Bend Fixture Tab up out of body and make ground and ballast connections. 2. Bend Fixture Tab back to Tab Access original position. Replace Plate Access Plate by reversing Opening removal instructions. END TRIM Install End Trim at beginning and end of row. 4 Fixture Screw T-bar (by others) 5 End Trim (for beginning and end of row) End Louver CONTINUOUS ROW COUPLER (LC UNITS ONLY) Remove screw as shown. Rotate Continuous Row Coupler (both sides of Fixtures) and secure Fixtures Continuous Row Coupler Fixture Tab INSTALL FIXTURES onto T-bars as shown. T-bar Fixture HOLD-DOWN CLIPS (LI UNITS ONLY) Install Hold-down HoldClips at Down Clip beginning and end of rows. together with Screw. Tighten all Screws to secure Fixtures to T-bar with Hold-down Clips. Fixtures Screw Holddown Clip Continuous Row Coupler Screw T-bar Lightolier is a Philips group brand Screw Coupler is used at end or beginning of row to secure End of Row Fixture to T-bar (by others) Hold-down Clip T-bar Fixtures End of Row Fixture Fixtures Screw 2 Ground Screw Hold-down Clip T-bar (by others) Lytecel LI / LC 45 Industrial Way, Wilmington, MA 01887 (978) 657-7600 • Fax (978) 658-0595 We reserve the right to change details of design, materials and finish. www.lightolier.com This product may have a mercury containing lamp. Manage in accordance with Disposal Laws. See: www.lamprecycle.org 6 8 FOR 1 LAMP To open Louver, Fixtures press Spring Latch in direction of Arrow. To close, insert louver into Fixture until Spring Latches automatically engage. Installation Instructions Standard or Slot Grid Ceiling Systems 7 Spring Latch FOR 2 LAMP To open Louver, place finger or small tool Fixtures thru Access Hole in Louver and press Spring Latch in direction of arrow. To close, insert louver into Fixture until Spring Latches automatically engage. Spring Latch LENS INSTALLATION (Individual, LI, unit only) Follow disgrams 8a - 8c. To remove lens reverse installation. 8a 8c 8b Lens with prismatic side down (Away from lamp) 59-31123-001 Rev.A Lightolier is a Philips group brand Printed in U.S.A.